Top UCA2 User manual

Thank you for choosing TOP VME .
UCA2
Coin Acceptor
User Guide


Contents
1.Introduction ……………………………………………………………………………………… 1
1-1.Overview ……………………………………………………………………………………………… 1
1-2.Features ……………………………………………………………………………………………… 1
2.Specification ……………………………………………………………………………………… 2
2-1. General………………………………………………………………………………………………… 2
2-2. Electronic …………………………………………………………………………………………… 2
2-3. Machine ……………………………………………………………………………………………… 2
3.Packing List ……………………………………………………………………………………… 2
4. Dimension………………………………………………………………………………………… 3
5. Installation ……………………………………………………………………………………… 4
5-1. Harness Application …………………………………………………………………………… 4
5-2. I/O Circuit …………………………………………………………………………………………… 9
5-3. Installation Notes………………………………………………………………………………… 11
6. Maintenance …………………………………………………………………………………… 13
7. Troubleshooting ……………………………………………………………………………… 14
8. RS232 Protocol ………………………………………………………………………………… 15
8-1. Enable or Disable ……………………………………………………………………………… 15
8-2. Request UCA status …………………………………………………………………………… 16

Contents
8-3. Get UCA Version ………………………………………………………………………………… 16
8-4. Accept Setting …………………………………………………………………………………… 16
8-5. Inhibit Setting ……………………………………………………………………………………… 17
8-6. Upgrade Start ……………………………………………………………………………………… 17
8-7. Upgrade Finish …………………………………………………………………………………… 17
8-8. Upgrading …………………………………………………………………………………………… 17
8-9. Upgrade Verify …………………………………………………………………………………… 18
8-10. Read Start ………………………………………………………………………………………… 18
8-11. Read Finish………………………………………………………………………………………… 18
8-12. Reading……………………………………………………………………………………………… 18

1
Coin Acceptor
1
1.Introduction
1-1.Overview
UCA2 is designed as reliable coin acceptors which are able to work steadily
in high temperature for high-security with acceptance rate up to 96% or
greater.
1-2.Features
• Low power consumption.
• Mechanical and electrical anti-string functions.
• Accepting speed up to 3 coins per second.
• CS100 Coin dispenser supports UCA2.
• Remote control: Multiple function commands are issued
• Can operate in high temperature environments.
• Can receive 8 currencies at the same time
• Online update for receiving coin types

2
UCA2
2
2.Specification
2-1. General
Acceptance Rate 96 % or greater
Accepting Speed Approx. 3 coin/sec
Interface PULSE / RS232 (TTL level)
Installation Indoor
Coin Parameters (D) : 20mm-32mm( T ) : 1.2mm- 3.2mm
2-2. Electronic
Power Source 12V DC ± 10%
Power
Consumption
Standby : 0.05A / 0.6W
Operration Current : 0.20A / 2.4W
Maximum : 0.50A / 6W
Temperature
Range
Operating Temperature : 0° C~60° C
Storage Temperature : -10° C~80° C
Humidity : 20%~70%RH
(no condensation)
2-3. Machine
Weight 350 ±10 g
Outline
Dimension 124 x 72.4 x 147.5 mm
3.Packing List
Main UCA2 Coin Acceptor
Accessories
User Guide
Harness
Screw set

3
Coin Acceptor
3
4. Dimension
Unit : mm [ inch ]

4
UCA2
4
5. Installation
5-1. Harness Application
Interface Voltage Usage Harness NO. Page
Pulse 12V DC
Power & Data
Communication WEL-RMS03 5
Power & Data
Communication
WEL-RMS02
(Purchase) 6
Extension Cable CU-R961-1
(Purchase) 7
RS232
12V DC Power WEL-RMS03 5
+5V TTL Data
Communication WEL-R7U06 8
NOTE : Software download
Please refer to the G-BOX Operation manual for a guide step by step how
to download or update using the G-Box programmer. You can obtain it from
WEL-RMS02
WEL-RMS03
Download
CS100 Harness
WEL-R7U06

5
Coin Acceptor
5
PIN NO COLOR PIN DEFINE
PIN1 RED +12V DC
PIN2 ORANGE GND
PIN3 GREEN INHIBIT+
PIN4 YELLOW METER
PIN5 BLUE CREDIT
PIN6 X X
WEL-RMS03

6
UCA2
6
WEL-RMS02
PIN NO COLOR PIN DEFINE
PIN1 YELLOW METER
PIN2 GREEN INHIBIT+
PIN5 RED +12V DC
PIN7 BLUE CREDIT
PIN8 PURPLE X
PIN9 ORANGE GND
PIN NO COLOR PIN DEFINE
PIN1 RED +12V DC
PIN2 ORANGE GND
PIN3 GREEN INHIBIT+
PIN4 YELLOW METER
PIN5 BLUE CREDIT
PIN6 PURPLE X

7
Coin Acceptor
7
CU-R961-1
PIN NO COLOR PIN DEFINE
PIN1 YELLOW INHIBIT+
PIN2 GREEN INHIBIT-
PIN5 RED +12V DC
PIN7 BLUE METER+
PIN8 PURPLE METER-
PIN9 ORANGE GND

8
UCA2
8
WEL-R7U06
PIN NO PIN DEFINE
PIN2 TXD
PIN3 RXD
PIN5 GND
PIN NO COLOR PIN DEFINE
PIN1 BLUE GND
PIN6 WHITE VCC
PIN7 BLACK RXD
PIN8 PURPLE TXD

9
Coin Acceptor
9
5-2. I/O Circuit
• Pulse Interface

10
UCA2
10
• RS232 Interface

11
Coin Acceptor
11
5-3. Installation Notes
Please follow the steps below to install the UCA2 .
1. Use four screws to fix bezel on the machine
2. Fix main base on bezel by mounting clips.
Mounting Clip
Mounting Clip

12
UCA2
12
Installation Precautions :
• UCA2 is not supposed to be aslope over 3°。
• To make sure UCA2 work smoothly, install machine farther than 3 cm from
metal items is recommended.

13
Coin Acceptor
13
6. Maintenance
To make sure UCA2 always works smoothly, please clean the internal sensors
regularly:
To clean the internal sensors:
1. Remove bezel by releasing mounting clips and pulling it out.
2. Release the clip and remove lower base cover plate and hood.
3. Use a soft, dry cloth, or towel to clean lens
Bezel
Lower Base
Cover Plate
Mounting Clips
Hood

14
UCA2
14
4. Open upper base cover plate and then use a soft, dry cloth, or towel to
clean sensor.
7. Troubleshooting
LED flashes Status Corrective Actions
Green Orange Red
sustained X X Power on -
Xsustained X Inhibit -
X flicker X I/O Test Mode -
X X 1 Fast coil set error Call TOP or agents for
technical support.
X X 2 Second coil set error
Inspect for foreign objects in
coin path and clean.
X X 3 Fish sensor error
X X 4 Drop sersor error
X X 5 Retrun sersor error
X X 6 IR sensor error
X X 7 Program error Call TOP or agents for
technical support.
X X Fast 2 A Stringing attempt
has been detected.
Inspect for foreign objects in
coin path and clean.
Drop in Sensor
IR Sensor& LED
Return Sensor

15
Coin Acceptor
15
8. RS232 Protocol
1. Transmission Specification
Transmission Method : Full Duplex Transmission
Transmission Speed : 9600 Baud Rate
Synchronizing Method : Asynchronous Method
Data Format : Start bit 1, Data bit 8, Parity bit none, Stop bit 1
2. General Message Command Format
SYNC + LNG + CMD + DATA + EXT + CS
Name Byte Contents
SYNC 1 start code , [90H] fixed
LNG 1 Data Length (Total number of bytes from SYNC to
checksum)
CMD 1 Command
DATA 0~250 Data necessary for command( omitted by CMD )
EXT 1 End code , [03H] fixed
CS 1 checksum by SUM result method without carry ( from
SYNC to EXT )
There are 2 types of messages used :
Format-1 without DATA : SYNC + LNG + CMD + EXT + CS or SYNC + LNG +
CMD + CS
Format-2 with DATA : SYNC + LNG + CMD + DATA + EXT + CS or SYNC + LNG
+ CMD + DATA + CS
8-1. Enable or Disable
VMC to UCA2
90h 05h 01h 03h 99h Enable UCA
90h 05h 02h 03h 9Ah Disable UCA
UCA2 to VMC
90h 05h 50h 03h E8h ACK
90h 05h 4Bh 03h E3h NAK

16
UCA2
16
8-2. Request UCA status
VMC to UCA2
90h 05h 11h 03h A9h Request status
UCA2 to VMC
90h 05h 11h 03h A9h Idling
90h 05h 14h 03h Ach Disable
90h 06h 16h 01h 03h B0h Sensor Problem COIL 1
90h 06h 16h 02h 03h B1h Sensor Problem COIL 2
90h 06h 16h 03h 03h B2h Sensor Problem DROP IN 2
90h 06h 16h 04h 03h B3h Sensor Problem DROP IN 1
90h 06h 16h 05h 03h B4h Sensor Problem COIL 2
90h 06h 16h 06h 03h B5h Sensor Problem COIL 2
90h 05h 17h 03h AFh Fishing
90h 05h 18h 03h B0h Program Checksum Error
90h 05h 4Bh 03h E3h NAK
8-3. Get UCA Version
VMC to UCA2
90h 05h 11h 03h A9h
UCA2 to VMC
90h 10h 03h 56h 31h 2Eh 30h 36h
2Dh 54h 48h 42h 34h 03h 00h
8-4. Accept Setting
VMC to UCA2
90h 06h 12h 01h 03h ACh Accepting channel 1
90h 06h 12h 02h 03h ADh Accepting channel 2
90h 06h 12h 08h 03h B4h Accepting channel 8
UCA2 to VMC
90h 05h 50h 03h E8h ACK
90h 05h 4Bh 03h E3h NAK
Table of contents
Other Top Cash Counter & Coin Sorter manuals
Popular Cash Counter & Coin Sorter manuals by other brands

Money Controls
Money Controls C120S Technical manual

Sanela
Sanela SLZA 40GVZ Mounting instructions

Royal Sovereign
Royal Sovereign Fast Sort FS-3D owner's manual

Ribao
Ribao CS-610S+PRO Operation manual

Azkoyen
Azkoyen Hopper U 3030 Series Technical manual

Royal Sovereign
Royal Sovereign DCB-275D owner's manual

Royal Sovereign
Royal Sovereign Fast Sort FS-4DA owner's manual

Paytec
Paytec CV3516 user guide

Ribao
Ribao CS-311S Operation manual

American Changer
American Changer AC2006 Installation, operation and service manual

CUMMINS ALLISON
CUMMINS ALLISON JetSort 1000 series Set up and operating instructions

ratiotec
ratiotec CS 150 special instruction manual