tousek GSM 400 User manual

Connection and installation manual
GSM-receiver GSM 400

- 2 - tousek / E_GSM-400_00 / 07. 05. 2018
Warning notes
• Installation, adjustment and maintenance may only be carried out by trained personnel!
• Carrying out works at the receiver is only admissible after the power supply has been turned off!
• Only turn on the power supply again after another check!
• A proper operation is only given, when these installation instructions are strictly followed.
Safety
• The device GSM 400 contains a state-of-the-art Quadband GSM module. For correct installation and use of this product,
please follow the instructions given in this manual. The use of the device GSM 400 near radio, television, telephone or
other electronic devices can lead to reception inuences and thus to functional disturbances.
• Never install the device in the vicinity of pacemakers, acoustic prostheses or general electronic medical equip-
ment as it could adversely effect the correct running of these appliances.
• GSM 400 is a radio-operated device. Since no mobile service provider can guarantee a constant connection anywhere
and at any time, this device can not be used as a personal emergency system.
• Don’t use this device in explosion hazardous areas and also in areas, where the usage of radio systems (e.g. mobile
phones,…) is forbidden.
• The Tousek radio system may only be used for devices and facilities, where no danger for persons or things arises from
a malfunction of transmitter or receiver, or where this risk is covered by other safety devices.
The remote controlling of devices and plants with an increased accident risk (e.g. crane facilities) is forbidden!
• For safe operation the local valid safety regulations for the plant have to be kept!
• The owner/user has to be informed that facilities with an increased accident risk may only be operated at direct
intervisibility.
This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior
written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.
EC-Declaration of Conformity
The company Tousek Ges.m.b.H. Automatische Torantriebe, Zetschegasse 1, A-1230 Wien
hereby declares that:
The GSM radio receiver GSM 400, GSM 420-RS 868 (GSM + 868 MHz)
conforms to the following EC directives:
2014/53/EU Radio Equipment Directive (RED)
2011/65/EU Restriction of the use of certain hazardous substances
in electrical and electronic equipment Directive (RoHS Directive)
The following European standards were applied:
ETSI EN 301 489-1 V1.8.1:2008
ETSI EN 301 489-7 V1.3.1:2005
ETSI EN 301 511 V9.0.2:2003
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + AC:2011 + A2:2013
EN 61000-6-2:2005 + AC:2005
EN 61000-6-3:2007 + A1:2011
Vienna, 04. 04. 2018

tousek / E_GSM-400_00 / 07. 05. 2018 - 3 -
70
90
60
Attention
• Check with your mobile provider whether the SIM
card can send and receive SMS.
• Note: A phone number can only be saved once.
(V) 230Va.c. power supply
(OUT 1) relay output
(P1) programming button P1
(L-GSM) GSM-LED
(L-1) programming-LED
(L-S) status-LED
(SIM) SIM-card
(A) connection GSM-antenna
Features
• 1-channel GSM-receiver (1 potential-free N.O. or N.C. Output), which can be controlled via call and SMS.
• One relay output with the operating modes ON / OFF, pulse or time controlled (from 0 to 9999 sec.) is set via SMS.
• In case of an event (eg Power ON Reset), the SMS and / or telephone calls can be sent to max. 8 telephone numbers.
• Function indications via LED.
• The possibility of inserting and cancelling up to 300 telephone numbers with gate opening functions.
If the calling number corresponds to one of the memorized numbers, the corresponding output relay gets activated.
• Suitable for DIN rail mounting.
•
Technical data
GSM-receiver GSM 400, 1-channel
power supply 230Va.c. telephone module SIM900 QBand
max. relay load 10A SIM type Standard
operating temperature -20°C to 50°C dimensions 70 x 90 x 60mm
protection class IP10 article no. 13280270
L N N.C. C N.O.
L-GSM
VOUT 1
P1 L-1
L-S
SIM
A
1. General GSM-receiver GSM 400

- 4 - tousek / E_GSM-400_00 / 07. 05. 2018
• Connect the desired impulse input of the control board to the
output terminals (OUT 1) of the GSM-receiver according to
the technical specications.
• Connect the GSM-antenna with the GSM-antenna connector
(A).
• Insert a valid SIM card (SIM).
• The SIM card must have a credit in order to
be able to use all functions.
• The PIN function must be deactivated.
• The answering machine function must be
disabled.
• ATTENTION: check the functionality of the
SIM card before inserting it into the mobile
phone.
• Connect the 230 Va.c. supply line with the supply terminals
(V). Then switch on the power supply.
• Wait approx. 30s until the connection LED (L-S) ashes
slowly and the device has found its network.
• Deactivate the redialing function of your
mobile phone.
• It is necessary to send your mobile phone
number.
• The GSM-LED (L-GSM) provides information about the
signal quality and shows possible errors.
L N N.C. C N.O.
L-GSM
VOUT 1
P1 L-1
L-S
SIM
A
2. Installation GSM-receiver GSM 400
To ensure a safe and reliable operation, the GSM 400 must only be installed only by qualified personnel.
GSM-LED display
display mode meaning
blinks rapidly module connects to the network (approx. 30s)
illuminates no GSM signal available
4x slow blinking + pause optimal GSM signal available
3x slow blinking + pause good GSM signal available
2x slow blinking + pause sufcient GSM signal available
1x slow blinking + pause insufcient GSM signal (signal is being tested once per minute)
4x fast blinking + lights in pause no SIM-card available
slow blinking the SIM-card is PIN-Code protected

tousek / E_GSM-400_00 / 07. 05. 2018 - 5 -
< 30s
P1
L-1 L-1
< 30s
P1P1
L-1 L-1
P1P1 P1 P1
L-1
3a. Save/ delete telephone numbers via telephone call Programming
The output of the GSM module can be switched by means of a telephone call. This does not incur any costs for the SIM card
of the module. For this function, the telephone number must be saved into the GSM receiver.
3. Programming GSM-receiver GSM 400
Save a telephone number
• Press the programming button (P1) once - the programming
LED (L-1) starts ashing.
• If the programming LED (L-1) lights up permanently, make
a call within 30s.
• As soon as the programming LED (L-1) ashes rapidly (the
GSM module receives this call), hang up.
Delete a telephone number
• Press the programming button (P1) twice - the programming
LED (L-1) starts to ash slowly.
• Make a call within 30 seconds from the number you want to
delete.
• As soon as the programming LED (L-1) goes off (the GSM
module receives this call), hang up.
Delete all telephone number
• Press the programming button (P1) three times and then
hold it pressed for at least 10s. The programming LED (L-1)
ashes quickly.
• As soon as the programming LED (L-1) goes off, you can
release the programming button (P1).
3b. Command and setting via SMS Programming
Important
• The default password is „12345“. It is advised to dene an own password (per SMS).
• SMS commands can be written in upper or lower case letters.
• At the receipt of a SMS which is not one of those included in table, the GSM module sends the message to the rst
telephone number in the memory (even if the password is not valid).
• Insert the international dialling code ( before the telephone number you want to memorize (e.g. +43 for Austria, +49 for
Germany).
•
The device answers to the conguration commands with a conrmation SMS („OK“) and to the control commands with
a telephone call.
Password RESET
• Unplug the power plug, press the programming button
(P1) and hold it pressed.
• Now plug the mains plug in and wait until the programming
LED (L-1) lights permanently after approx. 10s after initial
ashing.
• Now release the button (P1) and plug the mains plug OFF
and ON again!
SMS texts are used for both setting the device functions as well as for requesting information from the device. The
SMS commands with their descriptions and stored default values for each determined parameter are laid out in the
table “SMS commands”.
ca. 10s
P1P1
L-1

- 6 - tousek / E_GSM-400_00 / 07. 05. 2018
SMS commands / basic settings
command entry
1
password change: [ = 12345 ]
changes the (standard-)password into a new one.
pass:password (max. 5 digits)
passn:new password (max. 5 digits)
pass,PWD,passn,passn
e.g. password change:
12345,PWD,23854,23854
→ new password: 23854
2
Reset:
all parameters are being set to default value and the
complete tel. number list deleted.
pass:password (max. 5 digits)
pass,RESET
e.g. 12345,RESET
3
Memorize a telephone number in the telephone numbers list
(for feedbacks):
It is possible to memorize max. 8 telephone numbers for feedbacks via
SMS and/ or call.
pass:password (max. 5 digits)
x: memory position in the tel. number list (1–8)
telnr: tel. number (max. 19 digits)
An already existing number memorized at this place will be overwritten.
pass,TEL,x,telnr
e.g. 12345,TEL,3,+43699123456789
4
delete telephone number:
deletes a tel.number from the list.
pass:password (max. 5 digits)
x: memory position in the tel. number list (1–8)
pass,DEL,x
e.g. 12345,DEL,3
5
request telephone number list:
the list of actual memorised tel. numbers for response are being sent
by SMS.
pass:password (max. 5 digits)
pass,NUM?
e.g. 12345,NUM?
6
activation of SMS-message when switching on:
When switching- on the device an SMS + call gets sent to the tel.
number memorized under point 1.
pass:password (max. 5 digits)
pass,PW,ON
No SMS-message when switching on [ = ]:
no message when switching on the device.
pass:password (max. 5 digits)
pass,PW,OFF
7
check functionality of device:
operating state gets checked.
pass:password (max. 5 digits)
answer-SMS: „System OK“ + call
pass,CKE

tousek / E_GSM-400_00 / 07. 05. 2018 - 7 -
SMS commands / Befehlsgebung
command entry
8
Save telephone numbers for GATE OPEN-command:
to save telephone numbers that should enable an opening command
on output through a call (max. 300).
pass:password (max. 5 digits)
telnr:
telephone number (max. 10 per command separated by comma)
IMPORTANT: the country code (e.g. +43) , depending on automatic
exchange in country, may be necessary!
It is necessary to send your mobile phone number!
pass,
MAC,telnr,telnr,...
e.g. 12345,MAC,+436641234567,
+436767654321
if a tel. number is followed by a „U“, an by a digit yyy, it means that,
this number executes a dened amount of operations (in this exapmle: 5),
and that the number gets then deleted.
pass,
MAC,telnrUyyy
e.g. 12345,MAC,+436767654321U5
9
delete telephone numbers for GATE OPEN-command:
to delete telephone numbers, that were enabled to generate an ope-
ning command through a call.
pass:password (max. 5 digits)
telnr:
telephone number (max. 10 per command separated by comma)
pass,
DAC,telnr,telnr,...
e.g. 12345,MAC,+436641234567,
+436767654321
To delete a phone number using „DAC“, it is necessary to dial it with the same dial code/ prex
that was used to store it with the command „MAC“!
10 delete all telephone numbers for GATE OPEN-command:
pass:password (max. 5 digits) pass,
DAC,
pass,pass
e.g. 12345,DAC,12345,12345
Saving / deleting telephone numbers is also possible by means of a call (see point 3a)
SMS Commands / In-, outputs
command entry
11
activation of outputs OUT 1:
pass:password (max. 5 digits)
z: number of concerning output (=1)
telephone call
pass,OUT,ON,z
e.g. 12345,OUT,ON,1
12
deactivation of outputs OUT 1 [ = ] :
pass:password (max. 5 digits)
z: number of concerning output (=1)
telephone call
Note: in the „monostable“ operating mode, this command has no effect since
the shutdown is performed automatically (after 0.5s).
pass,OUT,OFF,z
e.g. 12345,OUT,OFF,1
13
request status of output OUT 1:
pass:password (max. 5 digits)
answer SMS: „out 1 on (off) + call
pass,OUT?
14
output relay OUT 1 set to MONOSTABIL [ = ]:
sets the switching behaviour of the output relay to monostable (active for 0,5s).
pass:password (max. 5 digits)
.
z: number of concerning output (=1)
pass,OUTRE,z,M
e.g. 12345,OUTRE,1,M
output relay OUT 1 set to BI-STABLE:
sets the switching behaviour of an output relay to bistable (ON, OFF).
pass:password (max. 5 digits)
z: number of concerning output (=1)
pass,OUTRE,z,B
e.g. 12345,OUTRE,1,B
output relay OUT 1 with TIMER:
sets a timer function for an output relay.
pass:password (max. 5 digits)
z: number of concerning output (=1)
yyyy: time in seconds (1–9999s)
pass,OUTRE,z,Tyyyy
e.g. 12345,OUTRE,1,T60

tousek PRODUCTS
• slidinggateoperators
• cantileversystems
• swinggateoperators
• garagedooroperators
• foldingdooroperators
• tracbarriers
• carparkmanagementsystem
• windowoperators
• domelightoperators
• slidingdooroperators
• electroniccontrols
• radioremotecontrols
• keyoperatedswitches
• accesscontrol
• safetydevices
• accessories
your service partner:
Tousek Ges.m.b.H.Austria
A-1230Vienna
Zetschegasse1
Tel.+43/1/6673601
Fax+43/1/6678923
Tousek GmbHGermany
D-83395Freilassing
TraunsteinerStraße12
Tel.+49/8654/7766-0
Fax+49/8654/57196
Tousek BeneluxNV
BE-3930Hamont-Achel
Buitenheide2A/1
Tel.+32/11/916160
Fax+32/11/968705
Tousek Sp. z o.o.Poland
PL43-190Mikołów(k/Katowic)
Gliwicka67
Tel.+48/32/7385365
Fax+48/32/7385366
Tousek s.r.o.CzechRepublic
CZ-13000Praha3
Jagellonská9
Tel.+420/2/22090980
Fax+420/2/22090989
Wereservetherighttochangedimensionsand/ortechnicalspecicationswith-
outpriornotice.Claims resultingfrommisprintsorerrorscannot beaccepted.
tousek
E_GSM-400_00
07. 05. 2018
Table of contents