Technical data main unit
SafeLine GL6
Power: 230 VAC, 50 Hz, max 9 W
Battery: 12 V, 0.8 Ah
Inputs: 10-30 VDC, 5 mA optically isolated
Antenna connector: SMA (female)
Size: 96 x 145 x 58 mm (H x W x D) (without antenna)
Weight: 830 g
Relay output: 1 A/30 VDC, potential free relay contact output
IP code:
IP20
Output:
12 VDC maximum output 120 mA continuous, 500 mA max 10 min
SafeLine Pro version: SL Pro 4.45 or later
Output indicator intercom: 12 VDC, max 100 mA
Line voltage: 48 VDC
USB: USB mini 2.0
Interface board: *SL6-GSM-BOARD: Dual bands 900/1800 MHz
- Micro SIM, 25 x 15 x 0,76 mm
- Supports 2G
- Requires SW 1.00 or later
*IF-BOARD-4G
- Micro SIM, 15 x 12 x 0,76 mm
- Supports 2G, 3G and 4G
- Requires SW 1.20 or later
SIM card size:
Micro SIM
Communication: GSM-module, dual-band 900/1800 MHz
Operating temperature: +5 - 40C
Air humidity: 30 - 90 % RH
Software version: SW 1.10 or later
Introduction
Technical data 2
General information 3
Overview
Introduction and overview 4
Installation
Wiring diagram & relay output 5
Intercom 6
Using the SIM card 7
Conguration
LED indication 8
SafeLine Pro 9
Operating
Operating 13
Service
Troubleshooting 14
Interference/poor sound quality 14
Certicate
Declaration of Conformity 15

3
GL6+ v.2.01 EN
Introduction
This unit was built with state-of-the-art technology and to
generally recognised safety related technical standards currently app-
licable. These installation instructions are to be followed by all people
working with the unit, in both installation and maintenance.
It is extremely important that these installation instructions are made
available at all times to the relevant technicians, engineers or servicing
and maintenance personnel. The basis prerequisite for safe handling
and trouble free operation of this system is a sound knowledge of the
basic and special safety regulations concerning conveyor technology,
and elevators in particular. The unit may only be used for its intended
purpose. Note in particular that, no unauthorised changes or additions
may be made inside the unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect to the buyer of this product
or to third parties for damage, loss, costs or work incurred as a result of
accidents, misuse of the product, incorrect installation or illegal chang-
es, repairs or additions. Claims under warranty are likewise excluded in
such cases. The technical data is the latest available. The manufacturer
accepts no liability arising from printing errors, mistakes or changes.
Declaration of conformity
Download ”The declaration of conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals, who are authorised to work on the equip-
ment, should install and con gure this product.
- This quality product is dedicated for the lift industry. It has been
designed and manufactured to be used for its speci ed purpose only.
If it is to be used for any other purpose, SafeLine must be contacted in
advance.
- It should not be modi ed or altered in any way, and should only be
installed and con gured strictly following the procedures described in
this manual.
- All applicable health and safety requirements and equipment
standards should be considered and strictly adhered to when installing
and con guring this product.
- Af ter installation and con guration this product and the operation
of the equipment should be fully tested to ensure correct operation
before the equipment is returned to normal use.
Electrical and electronic products may contain materials, parts and
units that can be dangerous for the environment and human health.
Please inform yourself about the local rules and disposal collection
system for electrical and electronic products. The correct disposal of
your old product will help to prevent negative consequences for the
environment and human health.
General
information

4
LED1LED2 LED3
GL6+ v.2.01 EN
Introduction
Introduction and
overview
The GL6 is a line emulator that simulates a
standard telephone line. It can be used together with all
SafeLine telephones or any other PSTN (Public Switched Telephone
Network) telephone. Easy to install and suitable as both temporary
or permanent installation.
Features:
• 230 VAC supply voltage.
• GSM to analogue PSTN telephone line.
• Built-in intercom functionality.
• Telephone line for up to nine SafeLine units.
• Connect any analogue telephone.
• Integrated 12V UPS for up to four SafeLine MX3/MX2/SL2 or SL1.
• Automatic battery condition check every 7 days.
• 1 input for monitoring an event with the possibility to send an
SMS alert.
• 1 programmable output.
• Can be used with a pay-as-you-go SIM card or a standard
subscription SIM card.
• Theft protection – option to randomly generate PIN code.
• Mains failure control via SMS.
• Adjustable call time between 1-99 min (0 = unlimited).
• Battery discharge protection.
More detailed information about the features can be found in the
Operating section.
Options for the reset button
Start a battery test manually Press 3 times
Cancel battery test Press once
Reset a GSM call Press once
Check GSM network signal strength Press for 3 seconds
Turn off when using battery power Press for 5 seconds
Turn on when using battery power Press once
Reset button
Intercom button
Press once to activate
an intercom call
USB-mini - conguration
via SafeLine Pro

5
Micro
SIM Card
= NC
= NO
GL6+ v.2.01 EN
Installation
or
Wiring diagram
& relay output
There are three ways to congure the
relay output (congurable in SL Pro).
1. Battery failure
Relay is active if battery test has failed.
2. System failure
Relay is active when GL6 has GSM
network coverage. Relay deactivates
when GSM network is missing for more
than 15 seconds or when mains power
has been off for more than 15 minutes.
3. Emergency light
Relay is activated when there is a
mains power failure, and switches to
battery power.
Intercom RJ12
Telephone line out RJ12
Telephone line out
Telephone line out
+ Battery
— Battery
Input intercom
Indicator intercom
Relay 1, NO/NC
0 V out
+12 V out
230 VAC L
230 VAC N
Relay output
Input 1: Lift Monitoring System
(LMS)/SMS. Programmable
input for LMS to send SMS
messages to up to 3 different
numbers.
SMAconnector
for antenna
Battery
SIM card

6
[g. 4]
123
4 5 6
78 9
0
*#
1 2 3
4 5 6
97 8
*0#
SafeLine MX3+
serial no.
hologram
sw ver.
www.safeline-group.com
GL6+ v.2.01 EN
Installation
Intercom
Method 1:
Push button once to
activate intercom.
Method 2:
Push button to
activate intercom,
must be N/O.
Optional indica-
tion of intercom.
The intercom function can be triggered in two ways:
1. Pressing the intercom button on the unit.
2. Using the intercom input (g. 4).
External indication of active intercom function can be wired between
12 VDC output and intercom indication output (g.4).
Use of intercom
When an intercom call is generated the GL6 rings up to 16 times,
waiting for a phone that is connected to the GL6 to answer. LED3
indicates when a ringing call expires, and when the call time counter
is activated. LED3 is activated as long the call is on. Maximum call
time is 5 minutes (not adjustable).
Maximum call time is 5 minutes.
After that, the call will be
disconnected. To cancel an
intercom call, press #.
SafeLine
MX3/MX2/SL2/SL1
Telephone

7
Micro
SIM Card
SIM card
GL6+ v.2.01 EN
Installation
The GL6 can only recognize the PIN code if the code is set to “1234”,
“0000”, “1111” or if it is deactivated. If set to anything else, the GL6
cannot use the SIM card.
If the PIN code is set to “1234”, “0000”or deactivated, the SIM card
can be used on any of SafeLine's GSM products.
Setting the PIN code
1. Insert the SIM card in an ordinary cell phone. In the phone's
security settings, change the PIN to “1234”. If not possible, set
the PIN code to “0000” or, if available, set the ”PIN code request”
option to “OFF”.
2. Verify the PIN code by switching your phone off and on again.
3. Make a call from your phone to verify that the SIM card is active.
4. Make a call to the GL6 after insertion to ensure there is a proper
connection.
"1111" PIN code
If the PIN is set to “1111”, the code will be randomly generated by the
SafeLine GSM unit and memorized. This is a safety measure, making
sure the SIM card will only work with the selected SafeLine GSM unit.
To change the PIN again, use the PUK code provided to you by your
mobile services provider for setting up a new PIN.
If you want to upload a new SIM card for the GSM unit with a new
“1111” PIN, you will rst need to upload a SIM card with PIN code
“1234” or “0000” to clear the old code in memory.
Using the
SIM card
Disconnect both mains and
battery plugs, before inserting
or removing the SIM card.

8
LED
1 2 3
= 100 %
= 85 %
= 70 %
= 55 %
= 30 %*
= 15 %
= 0 %
GL6+ v.2.01 EN
Conguration
LED indication
LED 2 indicates battery condition:
Light off
Battery OK.
Flashing red
Battery check in progress.
Continuous red
Battery test failure
LED 3 indicates the phone line’s status:
Slowly ashing green
GSM network OK.
Flashing green
Call connection in progress.
Flashing two times green
Connected handset is not hung up.*
Continuous green
Call connected.
Continuous yellow
In modem mode.
Flashing yellow
Incoming call.
Flashing red
Searching for GSM network.
Continuous red
No SIM card.
* Hash, ”#”, must be generated for the phone to disconnect the call.
Please ask the operator to press ”#” before hanging up.
GSM FIELD STRENGTH
If the reset button on the unit is pressed for 3 seconds the
GSM eld strength will be displayed for 5 seconds.
* Minimum signal strength
for using GSM Interface
LED 1 indicates the power supply status:
Continuous green
Mains power supply OK
Flashing red
Battery operated, no mains power supply
GSM SIGNAL
STRENGTH

9
1
2
3
4
5
6
7
8
GL6+ v.2.01 EN
Conguration
SafeLine Pro
Maximum call time for intercom is 5 minutes (not adjustable).
SafeLine Pro 4.45 or later is
required.
1. Call settings
• Max call time
Here you can choose the maximun call time between 1-99 minutes.
0 = Unlimited call time.
5 = Default value.
• RX audio level
Received Audio Level:
• Standard.
• +25% increase on the RX level of the receiver by 25%.
• +50% increase on the RX level of the receiver by 50%.
• +75% increase on the RX level of the receiver by 75%.
• +100% increase on the RX level of the receiver by 100%.
Note: Large increase may cause voice switching problems.

10
GL6+ v.2.01 EN
Conguration
SafeLine Pro 2. External input for monitoring
• Function
Here you can set the input to different functions.
• None: Input 1 is not enabled (default).
• SMS: Sends a text message when the input has reached the
set value.
• Type
Sets the input to N/O (Normally open) or N/C (Normally closed)
linked.
• Value
Sets the input activation time.
E.g. 10 min, 10 sec or 10 pulses before activating an event.
3. Relay output
Sets the output relay operating mode.
• None: the output relay is not enabled (default).
• Battery failure: the output relay is activated if the battery test has
failed.
• System failure:
• The output relay is activated when the GL6 has a GSM network.
• The output relay is deactivated when the GSM network has
been lost for more than 15 seconds, or when the power has
been off for more than 15 minutes.
• Emergency light: relay is activated when there is a main power
failure, and switches to battery power.

11
GL6+ v.2.01 EN
Conguration
SafeLine Pro
The green light next to ”SMS
Dialogue” is only active when
there is information added in
both the SMS destination and
Message eld.
Here you can enter information and specify the destination of the
text message.
• Battery failure SMS
If the battery test fails, a text message is sent.
• SMS destination: you can enter up to 3 mobile phone
numbers.
• Message: the limit for the message text is 128 characters
maximum. E.g.: "The battery test has failed at..."
• Mains failure SMS
A text message is sent if the 230 VAC supply has been lost for more
than 15 minutes.
• SMS destination: you can enter up to 3 mobile phone
numbers.
• Message: the limit for the message text is 128 characters
maximum.
• LMS input SMS
An text message is sent if the LMS input has reached the set
value.
• SMS destination: you can enter up to 3 mobile phone
numbers.
• Message: the limit for the message text is 128 characters
maximum.
4. Text message
5. Miscellaneous
Resets all input elds to their
default value. Puts SafeLine Pro in
basic mode execution, empties
phone elds etc.

12
GL6+ v.2.01 EN
Conguration
SafeLine Pro
6. Connection
Functions
• LMS input: lights green when the input is active.
• Intercom input: lights green when the intercom is activated.
• GSM net: lights green when there is enough network
coverage.
• Mains power: lights green when the input is active.
• Relay output: toggles the output relay on and off.
• Intercom output: toggles the intercom output on and off.
• Line output active: lights green when the line output is active.
Read
Reads out the conguration of the GL6.
Write
Write changes to the GL6.
• Software ver: here you can nd information about the GL6
software version.
• Hardware ver: here you can nd information about the GL6
hardware version.
• Serial number: here you can nd the serial number of the GL6.
• IMEI number (International Mobile Equipment Identity): the
IMEI is used by the GSM and UMTS mobile phones. The IMEI
is used by yhe GSM network to identify and authorize mobile
phones, and can thus stop the stolen mobile phones and make
them unusable.
7. Software / hardware information
8. File
Open a previously saved GL6 parameter le, or save the
current GL6 parameters to a le. E.g. IDD12345678.gl6.
Save the GL6 parameter le for use elsewhere, for example
if you have several GL6 with the same settings.
Test
With a computer directly to GL6.
Alarm type
• None: no test alarms activated.
• Battery failure: simulates a battery test
• Mains power failure: simulates a power failure.
• LMS message: simulates an operational alarm failure.

13
GL6+ v.2.01 EN
Operating
Operating Battery check
• Automatic battery test
Battery capacity is tested every 7 days. The test takes 15 minutes
maximum. If the battery test fails LED2 is activated. An SMS is sent
to 3 destinations maximum and with a maximum of 128 characters.
• Manual battery test
Start battery test by pressing the reset button 3 times. To cancel the
test press reset button once.
• Battery discharge protection
When the GL6 runs on battery power, the battery saver function will
turn off the GL6 when the battery level reduces to 10.7 volts. When
the mains power is reconnected the GL6 powers up again.
Mains power control
The GL6 is constantly monitoring the mains power. If power failure
occurs an SMS regarding the power loss will be sent after 15
minutes. An SMS is sent to 3 destinations maximum and with a
maximum of 128 characters.
External input 1 (SMS)
There is an input for monitoring with the possibility to send SMS
messages. The input requires 12VDC and it is possible to choose
between N/O and N/C (N/O is default). An SMS is sent to 3
destinations maximum and with a maximum of 128 characters.
GSM functions
GSM eld strength indication is active for 10 seconds when it is
activated by the reset button. If the GSM network coverage is lost,
the GL6 will automatically restart the GSM module after 10 minutes.
The GL6 provides 48 VDC line power only when it has GSM
network.
Outgoing call
Maximum call time for outgoing calls is congurable in SafeLine Pro
from 1 to 99 minutes (0 = unlimited). When a call is interrupted, the
GL6 generates. 10 busy tones, before it returns to standby mode.
GL6 used as GSM modem
GL6 can, through the USB-port, be used as a modem.
When the connected equipment is using the modem function, the
GL6 goes into “modem mode”. When an incoming call is detected,
the GL6 automatically identies if it is a voice call or a modem call.
With a vocie call, the GL6 generates a dial tone and waits for the
GL6 wired phone to answer. If it is a data call it goes into”modem
mode”. If the GL6 wired phone tries to call out during “modem
mode”, the “modem mode” immediately turns off and the GL6 goes
back to normal mode. For more information about the modem
functions, please see the SL6/GL6 GSM modem specication.
Conguration of GL6
Conguration of GL6 requires SafeLine Pro 4.45 or later.
Conguration can only be done in “standby mode”
All conguration must be done using the USB port.
Serial port is only for factory use.
SafeLine Pro 4.45 or later
is required.

14
GL6+ v.2.01 EN
Service
No LED’s are lit.
• Make sure that the supply voltage is: 230 VAC
LED 3 is continuously red.
• Make sure that the SIM card is correctly inserted.
• Check that the SIM card PIN code is deactivated or that the PIN
code is set to ”1234”, “0000” or ”1111” ("Using the SIM card"
p.7.)
• Make sure that the SIM card is activated and operational by
testing the card in a cellular phone.
The call is interrupted directly after being connected.
• Make sure the battery is properly charged. Check voltage with
the battery plug disconnected.
Call cannot be connected. Error message from telephone operator.
• To make a call, area code must always be used.
Troubleshooting
• Bear in mind that the wiring between GL6 and the lift telephone/
phone is basically a “standard” PSTN-line and can therefore
not be placed within the lift travelling cable together with high
voltage. *** (Risk of interference)***
• Always place the antenna in an upward position and at least
1,5m distance from GL6.
• Place the antenna where the highest eld intensity is obtained
according to the table on the unit ("GSM eld strength" p. 8).
• When a call is connected, try placing the antenna in different
places to nd where the best receiving/sending position is.
Interference/
poorsound quality

Your partner in lift safety
Antennvägen 10, 13548 Tyresö, Sweden
+46 (0)8-447 79 32, www.safeline-group.com
EU Declaration of Conformity
Product: Mobile network emulator
Type / model: Safeline GL6
Article no: *GL6, *GL6-4G, *GL6-FC, *GL6-FC-4G
Manufacturer: SafeLine Sweden AB
Year: 2017
We herewith declare under our sole responsibility as manufacturer that the products referred to
above complies with the following EC Directives:
Directives
Radio Equipment (RED): 2014/53/EU
RoHS 2: 2011/65/EU
Standards applied
EN 12015:2014 EMC: Emission, Electromagnetic compatibility
EN 12016:2013 EMC/Lifts: Immunity, Electromagnetic compatibility
EN 62368–1:2014/AC:2015 LVD: Information Technology Equipment
EN 50581:2012 RoHS: Technical doc. for assessment of restriction of RoHS.
For RED 2014/53/EU, the conformity assessment procedure “Module A” used as described in Annex II. Accordingly, respective
manufacturer has done the radio modules conformity assessment:
Standards applied Article of Directive 2014/53/EU
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
3.1 (a): Health and safety of the user
EN 62311:2008
EN 301 489-1 v2.1.1 + EN 301 489-52v1.1.0 Draft 3.1 (B): Electromagnetic Compatibility
EN 301 511 v12.5.1
3.2: Effective use of spectrum allocated
EN 301 908-1v11.1.1 /-2v11.1.1 /-13v11.1.1
Firmware used during assessment
GL865-Dual V3: 16.00.152 / 16.01.150 / 16.01.153
LE910-EU V2: 20.00.402
SafeLine GL6: 1.00
Tyresö, 2017-04-07
Lars Gustafsson,
Technical Manager, R&D , SafeLine Group
Module
Notified body
Address
NB nr
Test nr
1 GL865-Dual V3 2.
LE910-EU V2
Dekra Test &Cert
Dekra Test &Cert
Parque Tecnologico de Andalucia / SeveroOchoa
2, 29590 Spain
1909
1909
53051 RBN.001
52382 RCB.001

www.safeline-group.com www.safeline-group.com
SafeLine Europe
Industrieterrein 1-8 · 3290 Diest · Belgium
Support: +32 (0)4 85 89 08 95
SafeLine Deutschland GmbH
Kurzgewannstraße 3 · D-68526 Ladenburg · Germany
SafeLine Norway
Solbråveien 49 · 1383 Asker · Norway
SafeLine Denmark
Erhvervsvej 19 · 2600 Glostrup · Denmark
SafeLine Headquarters
Antennvägen 10 · 135 48 Tyresö · Sweden
Support: +46 (0)8 448 73 90
SafeLine Group UK
Unit 47 · Acorn Industrial Park · Crayford ·
Kent · DA1 4AL · United Kingdom
info@safeline-group.uk
Other manuals for GL6
1
Table of contents
Other Safeline GSM/GPRS Module manuals