SHORT WAVE HIGHEST VALUE TROUBLE AREA
Neither condition (*1) nor (*2) is met
and Short Wave Highest Val is
approximately 0 V
Since the insulation resistance is close to 0 Ω, there is
a strong possibility of interference with a metal object.
Neither condition (*1) nor (*2) is met
and Short Wave Highest Val is between 0
and 5 V
Since the insulation resistance is several hundred
kiloohms, there is a strong possibility of the presence
of fluid such as coolant.
2. How to Determine Part with Insulation Malfunction
(a) Jiggle the high-voltage wire harness to check if the resistance to body ground changes with the position of the
wire harness or force applied.
(b) Repeat rotating and stopping of the MG1, MG2 and compressor with motor. Check that the Short Wave
Highest Val does not decrease (for example if the motor stops with foreign matter forming a leak path) when
the motor stops, or that the Short Wave Highest Val does not return to normal (for example if foreign matter
moves away from the leak path) when the motor rotates.
(c) Increase the temperature of MG1and MG2. Check if the Short Wave Highest Val decreases with the
temperature increase.
INSPECTION PROCEDURE
CAUTION:
When troubleshooting P0AA6, be sure to wrap the tools with electrical tape. (It is very dangerous if high
voltage is shorted to ground through the tools.)
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with
converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug
grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other
technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage
connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection
point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with
converter assembly.
When measuring insulation resistance using a megohmmeter, set the megohmmeter to 500 V.
PROCEDURE
1. CHECK DTC OUTPUT (HV)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check if DTCs are output.
Result: