User gUideUser gUide P4/4
Features and presentations liable to changes without notice. Version C-1, 2018/12 edition.
Preamble
UnPacking
This notice includes all the advice and warnings that enables a correct set up and a safe use of the product.
TPLVision can not be responsible for the bad use of the notice. If so, TPL Vision cancels the guarantee’s effects.
Products are packed in our factory, using suitable materials for a safe transport through the usual means of transpor-
tation, in France and abroad. However, a damaged package must be reported to the carrier on delivery. Hand-written
reservations must be indicated on the delivery order. Moreover, please send a letter or an email to TPL Vision as soon
as possible (up to 24 hours after the delivery). If the transportation damage has not been stipulated on the delivery order
and reported to TPL Vision in time, the package will not be taken back nor exchanged. To open the package, do not use
any cutting blade so as to avoid damages on the product. Please use the delivered accessories, if needed (do not use
any other products or equivalents to replace the delivered accessories).
User secUrity
Do respect the power supply voltages and the connection terminals.
Do not modify or dismantle all or part of the product.
Do not connect or clean when power is on.
Do not watch the lighting source directly, and follow the advice below :
• If the workstation enables it, interpose a lter that will stop the lighting radiation under xed or adjustable
frame between the source and the operator.
• When these measures cannot be implemented, supply the operators with glasses (class 4) available for sale at
TPLVision, or with a dedicated protective mask, that will stop the lighting radiation.
• Forbid or limit the direct access to the lighting source (exposure into the radiation axis).
• Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond
therecommendations of the manufacturer, as for eye irritation is concerned.
• In any case, ensure that the chosen means properly reduce the exposition quantities (features of screens or
glasses to be chosen, according to the wavelengths that the operators are exposed to).
eqUiPment maintenance
CLEANING (when the product is switched off)
Please use a soft and dry cloth. Do not use any abrasive material.
Do not use any cleaning solvent or aggressive chemical product.
TPL Vision recommends to use isopropyl alcohol. risk class
The EN-62471 norm about lighting uxes enables the classication of led lightings in 4 distinct groups, according to their
hazardousness degree. Please nd below an indicative table, recapitulating the classes of risk for our standard products.
Colour Class Risk
White WHI, Green 525 nm, Red 630 nm 0none
UV 405 nm, Blue 470 nm, IR 850 nm 1low
UV 365 nm 2moderate
UV 385 nm 3high
In all cases, TPL Vision recommends
the use of the protection glasses
that are listed in its catalog.
For more information about photo-
biological risks, do not hesitate to
contact us.
connection
User gUide
M8 3 male points
+ 24 V
1
3
4
Ground
Strobe
STROBE MODE CONNECTION
+ 24 V
1
3
4
Ground
CONTINUOUS MODE CONNECTION
FRONT VIEW OF THE PRODUCT’S CONNECTOR
3
4black
1
brown
+ LED
blue
- LED
STROBE
Automate
P2/4 P3/4
During the set up, the light has to be switched off and
unplugged. Please use the xing holes designed for
that purpose (see scheme above).
We recommend the using of M3 screws (not supplied)
with a tightening torque from 0.5 to 1.5 Nm.
We also recommend the use of a threadlocker (not sup-
plied) to avoid any risk of loosening.
timetabledimming
strobe mode
0
20%
40%
60%
80%
100%
0%
1 2 3 4 5 6
VOLTS
Entrée Déclenchement
Sortie Éclairage
Triggering input
Light
+5V or +24V
Toward STROBE
input
From camera
/automate
+5V or +24V
From camera
/automate
0V
Toward STROBE
input
Resistance value
to be adapted
to the automaton.
Max. 4.7 kΩ
PnP-like aUtomaton oUtPUt nPn-like aUtomaton oUtPUt
Potential dimming between 1.5 and 5 Volts.
Above 5 Volts, the product reaches100%
of its lighting power. Power supply : 24V +/-10%
Strobe input : 24V or 5V TTL
1.5 ms 1 ms
fixing
dimensions
Internalø
(mm)
Externalø
(mm)
Width
(mm)
A B C
HPRING 58 112 28

Popular Camera Flash manuals by other brands

Nikon SB-N7 user manual

Nikon

Nikon SB-N7 user manual

Canon Speedlite 430EX II quick guide

Canon

Canon Speedlite 430EX II quick guide

Godox A1 user manual

Godox

Godox A1 user manual

Godox MS200 user manual

Godox

Godox MS200 user manual

Canon Speedlite 199 A instructions

Canon

Canon Speedlite 199 A instructions

Viltrox JY680L user manual

Viltrox

Viltrox JY680L user manual

Hensel Speed Max user manual

Hensel

Hensel Speed Max user manual

Godox V350N user manual

Godox

Godox V350N user manual

CULLMANN CUlight FR 36 C manual

CULLMANN

CULLMANN CUlight FR 36 C manual

SWIT Electronics S-2210D user manual

SWIT Electronics

SWIT Electronics S-2210D user manual

Metz Mecablitz 54 MZ-4i Specifications

Metz

Metz Mecablitz 54 MZ-4i Specifications

Bolt VS-570C user manual

Bolt

Bolt VS-570C user manual

Nikon SB-400 instruction manual

Nikon

Nikon SB-400 instruction manual

Canon Macro ring lite MR-14EX II Guide

Canon

Canon Macro ring lite MR-14EX II Guide

Lencarta SmartFlash 200 instructions

Lencarta

Lencarta SmartFlash 200 instructions

Godox V860IIIF user manual

Godox

Godox V860IIIF user manual

Canon Speedlite 90EX instruction manual

Canon

Canon Speedlite 90EX instruction manual

Godox Mini Pioneer 120 instruction manual

Godox

Godox Mini Pioneer 120 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.