Technology Creates Comfortable Life
TPS THERMAL CONTROLS LTD TEL +44(0)2891 473756 www.tpsthermalcontrols.com
Week adjusting →Return to Original Mode
Press “ ” for 3 seconds into week programmable mode.
▲
:
Temperature up/down or setting
▼: Temperature down or setting
Technical parameter option qualified person only
During power off, press “ ”and “ ” for 5 sec. into technical setting. It includes temperature correction, sensor option,
and low temperature protection, overheating protection, weekend option and locking setting. Then press “ ”
changeover into the relative item. Then, confirm it and turn on automatically.
Code
Option ▲or ▼
1 Temperature compensation
in internal sensor
-9 to +9
2 Sensor types 1
:
Internal Sensor
(
to control or limit the temperature
)
2
:
External Sensor
(
to control or limit the temperature
)
3
:
both Internal/ External Sensor
(
Internal sensor to control temperature,
external to limit temperature
)
of floor
Remark: Please make sure the right sensor. If choose the wrong or bad one,
LCD will display Err, the thermostat will stop working until eliminating the
failure.
3 Low temperature protection
setting.
5-15
℃
. When uo to Max. 15
℃
, press ▲. When display“- -”, cancel this
function.
4 High temperature protection
setting.
50-70
℃
. When down to Max. 50
℃
, press ▼. When display“- -”, cancel this
function.
5 Locking facility 0: During locking, power on/off unlock.
1
:
During locking, power on/off lock.
6 Weekend setting Two-day Weekend
:
12345 and 67 (Applicable for this products)