TR 1000 User manual

Hygiene Equipment
Designed for People
1
Registered at Medical Products
Agency, Sweden as a MDR Class 1
product according to MDR 2017/745.
TR reserves the right to make design
changes and/or improvements without
notice.
Always study this manual carefully before operat
ing
the Shower Chair.
The operator/user must always have access to the
Operating manual.
The Shower Chair is intended for professional use
only where the patient will be under supervision of
trained personnel.
Operating instructions and recommended
maintenance procedures are explained in the
following pages.
If you have any questions regarding the operation or
maintenance of your Shower Chair and cannot find
the answer in this manual, please contact us.
The Shower Chair is designed for years of trouble-
free operation, with proper use and maintenance.
Operating manual
Version 202
1
-
01
-
01
TR 1000
Shower Chair
Mandat
ory to read the manual before using
the equipment

Hygiene Equipment
Designed for People
2
Manufacturer
Page 3
Introduction
Page 4
Unpacking
Page 5
Initialization/Calibration
Page 6
I
ntended use
Page
7
Safety instructions
Page
8
-
General safety instructions
Page
8
-
In case of accident
Page 10
F
eatures and
controls
Page 1
1
Product description
Page 1
2
-
General product description
TR
1000
Page 1
2
-
Possible
combination
with other equipment
Page 1
3
Technical specification
Page
1
4
-
General technical specifications
Page 1
4
-
Measurements
TR
1000
in mm
Page 1
5
-
Measurements
TR 3000
in inch
Page 1
6
User instructions
Page
1
7
-
Height
& Tilt
adjustment
TR
1000
Page
1
7
-
Emergency stop
Page
18
-
Charging instructions
Page
19
-
Battery usage
Page 2
0
-
Armrests
Page 2
1
-
Castors
Page 2
2
-
Patient handling
Page 2
3
-
Patient handling
–
From wheelchair onto shower
chair
Page 2
3
-
Patient handling
–
Showering
Page 2
4
-
Patient handling
–
Toileting
Page 2
5
Labels & symbols on the lift
Page
2
6
Routine maintenance
Page
28
-
Before every use
Page
28
-
Daily
maintenance
Page
2
8
-
Monthly maintenance
Page
28
-
Annual maintenance
Page 3
9
-
Maintenance every 3 years
Page
30
-
Maintenance every 5 years
Page 3
0
Recycling
Page 3
1
Cleaning instructions
Page 3
2
Training record
Page 3
4
Maintenance record
Page 3
5
Table of contents

Hygiene Equipment
Designed for People
3
Manufacturer
TR Equipment AB
Rundelgatan 2
SE-573 35 Tranås
Sweden
Phone: +46 (0)140 38 50 60
www.trequipment.com
info@trequipment.se
Group subsidiaries:
USA
TR Group Inc. Phone: +1 (800) 7526900
www.trequipment.com
information@trequipment.com
United Kingdom:
TR Equipment Ltd Phone: +44 (0) 844 335 8386
www.trequipment.com
Germany:
TranspoRehamed GmbH Phone: +49 (0) 212-645850-0
www.transporehamed.de

Hygiene Equipment
Designed for People
4
Introduction
Dear Customer,
Thank you for choosing one of our quality products. We hope you enjoy the TR1000 Shower Chair.
This manual shall, in conjunction with staff training, ensure that the operator/user is always using
and/or operating the TR1000 correctly.
New users must be trained by qualified and experienced staff.
TR Equipment AB requires that each user has read and understands the entire operating manual
and that they can apply the instructions as specified. This applies to anyone who was not present at
the in-service training.
This instruction manual should generally be kept easily accessible for every user. Copying the whole
manual is encouraged since its sole purpose is to improve the standard of training and safety.
Please order another copy from us if the instruction manual is lost or unusable, or if it has become
illegible over time.
If you need further information, do not hesitate to contact TR Equipment AB or one of our qualified
partners.
Mandatory to read the manual before using the equipment.
Make sure you have read, understand, and applied the
information on the following pages before using the equipment.

Hygiene Equipment
Designed for People
5
Unpacking
TR1000 Shower chair is delivered on a wooden pallet surrounded by a wooden crate wrapped in
plastic.
Start unpacking the TR1000 by cut and remove the plastic. Unscrew and remove the wooden crate from the
pallet. DO NOT use any sharp tools that may scratch the Shower Chair.
Carefully lift off the wooden crate from the pallet. When lifted, do so briefly and use at least two people.
Carefully remove the TR1000 from the pallet.
See recycling instructions on page 31.
When moving the
TR1000
from the pallet, two people are required.

Hygiene Equipment
Designed for People
6
Initialization/Calibration
TR 1000 from October 1, 2014.
An initialization/calibration shall be performed on the lifting columns:
- Before first use
- Maintenance
- After replacement of lifting column/columns.
- After replacement of the tilt actuator.
Before starting the initialization/calibration process, make sure that the Emergency button are released and
not activated.
Initialization/Calibration:
- If the TR1000 is in the lowest position raise the chair by pressing the UP button on the hand control.
- Press the UP and the DOWN button on the hand control simultaneously. Keep the buttons pressed.
- After 8-10 seconds the lifting columns will start to lower the chair and the chair will be tilted
backwards. Keep the buttons pressed during the whole process.
- When the TR1000 is in the lowest position and the chair is fully tilted backwards the
initialization/calibration is finished and the TR1000 is ready to be used.

Hygiene Equipment
Designed for People
7
Intended use
TR1000 - Shower Chair
- The TR1000 is a battery-operated Shower Chair.
- The TR1000 is intended to be used indoors in all types of care facilities and private homes,
including hygiene areas.
- The TR1000 is only intended to be used for short term use <60min when in contact with breached
or compromised skin.
- The TR1000 is NOT intended to be used with patients that exceed a weight of 200kg / 440Ib.
Typical situations where the TR1000 Shower Chair is used includes:
- Transporting the patient to and from a showering area
- Showering and cleaning the patient
- Toileting
- Pedicure
- The resident must be able to sit straight up without support.
- The patient is typically a person who is unable to take care of their own personal hygiene.
- The user is any adult person who is capable of reading and understands the operating manual and
is qualified to care for dependent persons/patients.
Make sure you have read, understood, and appl
ied the information on
the following pages before using the shower chair.
Mandatory to read the Operating manual before using
the shower
chair
.

Hygiene Equipment
Designed for People
8
Safety instructions
General Safety instructions
If you have questions regarding operation or maintenance of your TR1000 Shower Chair and cannot find the
answer in this manual, please contact us!
- Before operating the TR1000, make sure that all transport packages and attachments are removed
so that nothing can be pinched between sitting frames and surfaces.
- Test all functions on the TR1000 (raising, lowering, tilting, arm rests) before use.
- The resident must be positioned comfortably in the Shower Chair, with arm rests securely down
folded, and safety belts shall be locked.
- Always physically check the water temperature before and during showering of the resident.
- The patient must be positioned comfortably on the stretcher mattress, with side rails securely locked.
- Make sure that all parts that comes in contact with the patient are intact and without sharp edges.
- Ensure that the Shower Chair can be moved, tilted, raised, or lowered safely to avoid any pinch
injuries on the resident.
- Castor brakes must be securely locked on the Shower Chair before transferring a resident and while
showering the resident.
- Operate the Shower Chair carefully when transporting patients through narrow corridors or over
irregular uneven surfaces.

Hygiene Equipment
Designed for People
9
Safety instructions
General Safety instructions
- During cleaning of the TR1000, avoid skin or eye contact with detergent, which is highly caustic. If
contact is made, rinse immediately with excess water. If irritation occurs, consult a Medical doctor.
Always read and follow detergent supplier instructions.
- The battery supplied by TR Equipment is the only one approved for the Shower Chair.
- The battery charger supplied by TR Equipment is the only one approved for the battery on the Shower
chair.
- The battery shall not be charged in wet or damp areas – Potential Shock hazard.
- It is recommended that the battery for the TR1000 Shower Chair are charged daily or whenever the
Shower Chair is not in use. The battery cannot be overcharged.
- Make sure that all castors are clean, in place and free from damages.
- Check that all screws are tightened and free from damages.
- The Shower Chair must be inspected visually for sign of wear. The Shower Chair should not be used if
defects are noted. Prompt service is required.
Mandatory to read the Operating manual before using the equipment.
Only qualified staff, who understand all operating and safety procedures
may operate the Shower Chair.
Nev
er leave the patient unattended.
NEVER use the TR1000 Shower Chair in any way that varies from the
safety precautions and operating procedures detailed in this manual. The
TR1000 Shower Chair must not be operated by anyone until the user has
read and understands the instructions in this manual.

Hygiene Equipment
Designed for People
10
Safety instructions
In case of accident
Note:
In case of a serious incident when using the TR1000 Shower Chair, this should be reported to the
manufacturer and to the local authorities where you are established.
TR Equipment AB
Rundelgatan 2
SE-573 35 Tranås
Sweden
www.trequipment.com
Phone: +46 (0)140 38 50 60
NEVER use the TR 2000/3000 shower trolley in any way that varies from
the safety precautions and operating procedures detailed in this manual.
The TR 2000/3000 shower trolley must not be operated by anyone until
the user has read and understands the instructions in this manual.
Group subsidiaries:
USA
TR Group Inc. Phone: +1 (800) 7526900
www.trequipment.com
United Kingdom:
TR Equipment Ltd Phone: +44 (0) 844 335 8386
www.trequipment.com
Germany:
TranspoRehamed GmbH Phone: +49 (0) 212-645850-0
www.transporehamed.de

Hygiene Equipment
Designed for People
11
1
Lifting columns
2
Chair seat
3
Chair backrest
4
Chair
headrest
5
Foldable armrests
6
Leg
rest
7
Bedpan incl. Lid (option)
8
Hand control
9
Battery pack
10
Front closin
g arm rests
(Option)
11
Castors with brake
12
Handgrip
13
Footrest
(Option)
14
Emergency stop
15
Safety belt
16
Chassis base
17
Snap on/off buckle
18
Chest belt (option)
Features and controls
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Hygiene Equipment
Designed for People
12
Product description
TR1000 – Shower Chair, battery operated
Height and tilt adjustable Shower Chair. As standard equipped with 4pcs Castors with brake, 2pcs Lifting
columns, 1pcs Tilt actuator, 1pcs Hand control, 1pcs Battery pack, 1pcs Battery charger, 2pcs Foldable arm
rests and 1pcs Safety belt.
TR1000 Part number: 0521000
TR1000
With front closing arm rests Part number: 0521010
Options for TR1000:
Bedpan incl. lid
Extra removable battery
Battery wall bracket
Factory mounted option:
Foldable and height adjustable footrest
Straight steering kit
Chest belt
Colored front closing armrests
Spacer kit (53mm higher)

Hygiene Equipment
Designed for People
13
Product description
Possible equipment combinations
TR
1000
Shower panel TR2810

Hygiene Equipment
Designed for People
14
TR 1000 – Shower Chair
TR 1000 – Dimensions and weights
TR 1000 - Voltage
Technical life span
Technical life span
10 years if the
product
is serviced an
d maintained
according to instructions in this manual.
Transport and storage
Ambient temperature
-
20°C
-
+70°C
-
4°F
-
+158°F
Maximum working load
200
Kg
/ 440Ibs
Control TR
1000
H
and
control
Operating range
(
S
eat)
535
–
9
3
5mm /
2
1”
–
3
7
”
Operating range (
Seat,
I
ncl. Spacer kit
)
588
–
98
8
mm /
2
3”
–
3
9
”
L
ifting stroke
4
00mm / 16”
Seat, Back rest, Armrest
Foamed PUR (Poly urethane)
Structure
Powder coated and
Z
ink plated steel and stainless
steel
Protection class
IP X
5
C
astors
T
win castors
Ø
100mm
Length
860mm / 63”
Height
(Head rest)
1350
–
1750mm / 53”
–
69”
Height
(
Head rest,
I
ncl. Spacer kit
)
1403
–
1803mm /
55”
–
71”
Width
700mm /
27,5”
W
eight
TR 1000
(
excl. options
)
7
5kg
/ 165Ibs
Supply voltage
24 VDC,
4
Ah (
L
i
t
hium
-
i
r
on
, rechargeable)
Battery charger input
100
-
240VAC, 50/60Hz
Battery charger out put
24VDC
Technical specification

Hygiene Equipment
Designed for People
15
Technical specification
TR 1000 – Shower Chair
Dimensions in mm

Hygiene Equipment
Designed for People
16
Technical specification
TR 1000 – Shower Chair
Dimensions in inch

Hygiene Equipment
Designed for People
17
User instructions
TR 1000 – Height & tilt adjustment
Always secure the resident with safety belt.
Maximum working load = 200kg / 440Ibs
Height
adjustment
UP & DOWN
Tilt adjustment
The tilt will stop in a neutral position.
The chair can be tilted forward to ease
transfer using the same button/symbol.
This shall always be done when the
chair is in the lowest position.

Hygiene Equipment
Designed for People
18
User instructions
TR1000 – Emergency stop
In case of an unexpected incident the Emergency stop can be activated.
- Push the Red button to activate the Emergency stop. The lifting columns and tilt actuator will stop
immediately.
- Turn the Red button clockwise to release the Emergency stop.

Hygiene Equipment
Designed for People
19
User instructions
TR1000 - Charging instructions:
The battery charger is intended to only be used indoors and in dry areas. The battery charger shall not be
installed in bathrooms or damp areas.
It is recommended to check battery status every morning before use (see LED indication - color & mode).
The cable connector of the battery shall always be unplugged before the battery is removed from the TR1000.
Status
LED indicator
-
colour & mode
Fully charged
Green
Continuously On
Charging
Green
Continuously short flashing
-
On (1 sec)/Off (1 sec)
High capacity
Green
Continuously
long flashing
-
On (0,5 sec)/Off (4 sec)
Low capacity
Orange
Continuously long flashing
-
On (0,5 sec)/Off (4 sec)
Under protection
OFF
Charging time
From empty to fully charged
8 Hours
The battery will not be overcharged
When you buy a TR1000 with a removable battery, our recommendation is to purchase an extra battery. The
extra removable battery shall immediately be put on charge to make the usage of the TR1000 and the
charging procedure more effective.
Batteries in storage must be put on charge to maintain the capacity of the battery.
The battery shall be charged in a dry area easy to locate.
The optional wall bracket shall be mounted in a convenient and reachable height. Always connect the battery
charger to the battery before you connect the charger to the mains.
Removable and rechargeable Lithium-Iron, battery 24V, 4Ah Wall bracket, part.no: 3232622

Hygiene Equipment
Designed for People
20
User instructions
TR1000 – Battery usage recommendations
- Before the first use, charge the battery for at least 24 hours. If you have purchased an extra
battery put that battery on charge when the first battery starts being used.
- If the TR1000 is used daily, charge the battery for at least 8 hours.
- If the TR1000 is used intermittently during a week, charge the battery 1-2 times per week, for at least
8 hours each time.
- Ideally if a battery is not in use, it should always be plugged into the charger. The battery pack cannot
be overcharged.
- If the TR1000 is only used occasionally the battery shall be put on charge after each use and for at
least 24 hours. The battery cannot be overcharged.
- If the shower chair shall be stored put the battery on charge until it will be used again or charge the
battery once per month and for at least 24 hours each time.
- Batteries in storage not being charged every month will eventually lose their ability to hold a charge.
Press the ON button for 1-2 seconds to start the battery
Press the OFF button for 3-4 seconds to turn it off.
When you disconnect the battery and battery charger from
the mains, a beep will be heard, and an Orange light will flash
for a couple of seconds.
You can only start the battery when it’s connected to the
control box connector on the TR1000.
Table of contents
Popular Wheelchair manuals by other brands

Vitea Care
Vitea Care HERO STAND UP Instructions for use

Invacare
Invacare Tracer 9000 Service manual

Invacare
Invacare Mistral Plus user manual

Invacare
Invacare Action 2 Basic Service manual

Sunrise Medical
Sunrise Medical Empulse F55 Directions for use

Sunrise Medical
Sunrise Medical Quickie IRIS owner's manual