Transmitter Solutions HIVE-DX User manual

1/8
6-1620026 rev.P4 22/02/2016
1
2
2 CHANNEL RECEIVER
3
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
NC2
COM2
NO2
NC1
COM1
NO1
12-24 V
HIVE-DX
Receiver Rolling Code, 2 channels with dry contact relay output 20A a 12 Vdc. Programming up to 800 transmitters.
Power supply 12-24 Vac/dc with automatic selection of the voltage, frequency 433.92Mhz.
To program the trasmitter to the relay 1, follow the following steps:
1. Press briey the P1 button. The display shows rad1.
2. Press the button of the transmitter you want to memorize. The display shows donE.
3. The receiver is still in programming mode and ready for a new transmitter.
4. To exit the receiver from program mode, press briey the P1 button or wait 10s of inactivity. If it quits by timeout, the display shows the
number of transmitters already memorized.
To associate the trasmitter to the relay 2, follow the following steps:
1. Press briey the P2 button. The display shows rad2.
2. Press the button of the transmitter you want to memorize. The display shows donE.
3. The receiver waits for a new transmitter.
4. To quit, press briey the P2 button or wait 10s of inactivity. If it quits by timeout, the display shows the number of transmitters already
memorized.
Note: if the transmitter is already memorized, the display shows fnd1 (associated to the 1st relay) or fnd2 (associated to the 2nd relay) and then
it exits from the process.
ATTENTION: a programmed button can not be memorized in both the relays. To change the associated relay, remove the transmitter associated
to the button from the memory and then make again the learning process.
NOTE: the programmed button of the transmitter will maintain the associated relay for all the functioning modes.
DESCRIPTION
PROGRAMMING OF THE TRANSMITTERS
To delete all the trasmitters from the relay 1, follow the following steps:
1. Press briey the P1 button.
2. When the display shows C1CLR and the OUT1 led blinks fast for 3s, release the button. The transmitters have been deleted from the relay 1.
To delete all the trasmitters from the relay 2, follow the following steps:
REMOVAL OF THE TRANSMITTERS
TERMINAL BOARDS
1-2: power supply,
12-24 Vdc-Vac
3-4: relay 1, N.O. contact.
4-5: relay 1, N.C. contact.
6-7: relay 2, N.O. contact.
7-8: relay 2, N.C. contact.
Code Rolling Code
Max transmitters 800
Power supply 12-24 Vac/dc
Consumption (12Vdc) 27mA (standby)
110mA (2 relay)
Channels 2 (NO or NC contact)
Frequency 433.92 MHz
Range (in open space) 80-100m*
Relay contact 12A at 12 Vdc
Temperature -10...55°C
*The range is inuenced by the type of transmitter,
antenna and radio interferences.
Thank you for choosing this Transmitter Solutions product.
Please read this manual carefully before installing the product.

2/8 6-1620026 rev.P4 22/02/2016
5
4
While the receiver is in standby the display shows the selected mode of functioning (mode1, mode2, mode3, mode4, mode5, mode6). During the process
of a timed command, the display blinks. During a step by step command, as in mode 5 and 6, the display does not blink.
To enter the menu, press briey the P3 button.
Press briey the P3 button to move inside the items of the menu and use the POTENTIOMETER to change the parameters.
The receiver saves the parameters when it quits the menu.
MENU DESCRIPTION
SELECTABLE
VALUES
min-max
DEFAULT UNIT
fUNCT
FUNCTION
Menu for the selection of the functioning mode:
1- Dual independent outputs.
2- Switching network.
3- Vestibule sequencing, type 1.
4- Vestibule sequencing, type 2.
5- Latched mode 1.
6- Latched mode 2.
1 - 6 1
-
Ton1
ACTIVATION TIME FOR RELAY 1 1 - 60 1s
Ton2
ACTIVATION TIME FOR RELAY 2 1 - 60 1s
TdLy
DELAY TIME BETWEEN THE ACTIVATION OF THE TWO RELAYS 1 - 60 1s
Power POWER OF THE SIGNAL
The display shows the quality of the transmission signal.
BAD - BEST - -
5.1 - FUNCTION
By accessing the item
funct
it is possible to set the functioning mode:
1
- Dual independent outputs: operates as a two channels receiver.
2
- Switching network: also known as a switching network or make/break relay, use this mode with a door operator & lock.
3
- Vestibule sequencing, type 1: to be selected if you want to sequence two doors in both directions, using just one receiver (requires two
conductors to the second door).
4
- Vestibule sequencing, type 2: to be selected if you want to sequence two doors in both directions, using two receivers and no wiring between operators.
5
- Latched mode 1: access control application. A transmitter signal programmed into the channel 1 will latch relay 1. While the relay 1 is latched, a
transmitter programmed into the channel 2 will activate the relay 2. When the channel 1 is in the off state, the receiver will ignore the channel 2 inputs.
6
- Latched mode 2: freight door application. In this mode a transmitter will active the relay 1 for an adjustable time, then latch the relay 2. The
relay 2 stays latched until another transmitter signal is received, then drops out immediately.
5.2 - ACTIVATION TIME FOR RELAY 1
By accessing the item
ton1
it is possible to select the activation time of the relay 1. Use the POTENTIOMETER to set a value between 1 and 60 s.
5.3 - ACTIVATION TIME FOR RELAY 2
By accessing the item
ton2
it is possible to select the activation time of the relay 2. Use the POTENTIOMETER to set a value between 1 and 60 s.
5.4 - DELAY TIME BETWEEN THE ACTIVATION OF THE TWO RELAYS
By accessing the item
tdLY
it is possible to select the delay time between the activation of the two relays. Use the POTENTIOMETER to set a value
between 1 and 60 s.
5.5 - POWER OF THE SIGNAL
By accessing the item
power
it is possible to verify the quality of the transmission signal of a transmitter already memorized.
When the display shows
-----
, press the button of the transmitter. The display can show:
•
bad
: the signal quality is very low. With a low signal quality it is suggested that you move the receiver to improve the signal.
•
good
: the signal quality is good.
•
best
: the signal quality is very high.
MENU
It is possible to select the code type in use on the receiver.
Follow this procedure for the selection:
1. Switch off the power supply.
2. Press and hold at the same moment all the buttons of the receiver. After 5 seconds, OUT1 and OUT2 leds blink:
• 3 times if the Rolling Code is enable. The display shows BiroL.
• 6 times if the Sawn Rolling Code is enable (Transmitter Solutions 433 MHz + KEELOQ
®
HCS300-301 compatible). The display shows sawn.
When the Sawn Rolling Code is set, a point appears on the display between the 3rd and the 4th digit.
CODE TYPE SELECTION
1. Press and hold the P2 button.
2. When the display shows C2CLr and the OUT2 led blinks fast for 3s, release the button. The transmitters have been deleted from the relay 2.
To delete a single trasmitter from the memory, follow the following steps:
1. Press the P1 or P2 button. The display shows rad1 or rad2.
2. Press the 1st key and the hidden button at the same moment of the transmitter that you want to erase.
3. When the display shows CLEAR, release the buttons. The transmitter has been deleted from the memory.

3/8
6-1620026 rev.P4 22/02/2016
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Door operator #2
Transmitter #2
PUSH
TO OPEN
Door operator #1
Transmitter #1
PUSH
TO OPEN
8
6
DISPLAY ERROR DESCRIPTION
F1ERR
It appears when there is an error during the erasing of all the transmitters already memorized in the relay 1.
F2ERR
It appears when there is an error during the erasing of all the transmitters already memorized in the relay 2.
F ERR
It appears when there is an error during the erasing of all the transmitters already memorized in both the relays.
FULL
Memory full
E RAD
It appears when there is an error during the learning of the transmitter.
EME
Memory error
E DEL
It appears when there is an error during the erasing of a single transmitter already memorized.
LoWPW
Supply voltage too low.
INI
It appears when the memory is initialized.
MODE 1 - DUAL INDEPENDENT OUTPUTS
MODE 1 - Dual indipendent outputs
Program the transmitter 1 on the relay 1. The transmitter 1 activates the relay 1 for the
TON1
time.
Program the transmitter 2 on the relay 2. The transmitter 2 activates the relay 2 for the
TON2
time.
PROGRAMMING - STEP BY STEP
1. Press briey the P1 button. The display shows rad1.
2. Press the button of the transmitter #1. The display shows done.
3. To quit, press briey the P1 button.
4. Press briey the P2 button. The display shows rad2.
5. Press the button of the transmitter #2. The display shows done.
6. To quit, press briey the P2 button.
7. To enter the menu, press briey the P3 button.
8. Set the item funCt to 1.
9. Press briey the P3 button.
10. Set the ton1 time to the desired value.
11. Press briey the P3 button.
12. Set the ton2 time to the desired value.
13. Press briey the P3 button.
14. Press briey the P3 button.
15. Press briey the P3 button.
ERROR REPORTING

4/8 6-1620026 rev.P4 22/02/2016
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Door operator
Electric Strike
Transmitter
Transmitter
12-24 Vac/Vdc
Power for Strike
PUSH
TO OPEN
PUSH
TO OPEN
9MODE 2 - SWITCHING NETWORK
MODE 2 - Switching network
You must program the transmitters on the relay 1.
The transmitters activate the relay 1 for the
TON1
time. Then, after the
TDLY
time, they activate the relay 2 for the
TON2
time.
PROGRAMMING - STEP BY STEP
1. Press briey the P1 button. The display shows rad1.
2. Press the button of the transmitter #1. The display shows done.
3. To quit, press briey the P1 button.
4. To enter the menu, press briey the P3 button.
5. Set the item funCt to 2.
6. Press briey the P3 button.
7. Set the ton1 time to the desired value.
8. Press briey the P3 button.
9. Set the ton2 time to the desired value.
10. Press briey the P3 button.
11. Set the tdLY time to the desired value.
12. Press briey the P3 button.
13. Press briey the P3 button.

5/8
6-1620026 rev.P4 22/02/2016
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Transmitter #3
Transmitter #4
Door operator #1
Door operator #2
Transmitter #2
PUSH
TO OPEN
Transmitter #1
PUSH
TO OPEN
PUSH
TO OPEN
PUSH
TO OPEN
10 MODE 3 - VESTIBULE SEQUENCING OPTION (1)
MODE 3 - Vestibule sequencing, type 1
Program the transmitters 1&4 on the relay 1.
The transmitters 1&4 activate the relay 1 for the
TON1
time. Then, after the
TDLY
time, they activate the relay 2 for the
TON2
time.
Program the transmitters 2&3 on the relay 2.
The transmitters 2&3 activate the relay 2 for the
TON2
time. Then, after the
TDLY
time, they activate the relay 1 for the
TON1
time.
PROGRAMMING - STEP BY STEP
1. Press briey the P1 button. The display shows rad1.
2. Press the button of the transmitter #1. The display shows done.
3. Press the button of the transmitter #4. The display shows done.
4. To quit, press briey the P1 button.
5. Press briey the P2 button. The display shows rad2.
6. Press the button of the transmitter #2. The display shows done.
7. Press the button of the transmitter #3. The display shows done.
8. To quit, press briey the P2 button.
9. To enter the menu, press briey the P3 button.
10. Set the item funCt to 3.
11. Press briey the P3 button.
12. Set the ton1 time to the desired value.
13. Press briey the P3 button.
14. Set the ton2 time to the desired value.
15. Press briey the P3 button.
16. Set the tdLY time to the desired value.
17. Press briey the P3 button.
18. Press briey the P3 button.

6/8 6-1620026 rev.P4 22/02/2016
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
RECEIVER #1
RECEIVER #2
Transmitter #3
Transmitter #4
Door operator #1
Door operator #2
Transmitter #2
PUSH
TO OPEN
Transmitter #1
PUSH
TO OPEN
PUSH
TO OPEN
PUSH
TO OPEN
11 MODE 4 - VESTIBULE SEQUENCING OPTION (2)
MODE 4 - Vestibule sequencing, type 2
RECEIVER 1
Program the transmitters 1&4 on the relay 1 and the transmitters 2&3 on the relay 2.
The transmitters 1&4 activate the relay 1 for the
TON1
time.
The transmitters 2&3 activate the relay 2 for the
TON2
time after the
TDLY
time.
RECEIVER 2
Program the transmitters 2&3 on the relay 1 and the transmitters 1&4 on the relay 2.
The transmitters 2&3 activate the relay 1 for the
TON1
time.
The transmitters 1&4 activate the relay 2 for the T
TON2
time after the
TDLY
time.
PROGRAMMING RECEIVER 1 - STEP BY STEP
1. Press briey the P1 button. The display shows rad1.
2. Press the button of the transmitter #1. The display shows done.
3. Press the button of the transmitter #4. The display shows done.
4. To quit, press briey the P1 button.
5. Press briey the P2 button. The display shows rad2.
6. Press the button of the transmitter #2. The display shows done.
7. Press the button of the transmitter #3. The display shows done.
8. To quit, press briey the P2 button.
9. To enter the menu, press briey the P3 button.
10. Set the item funCt to 4.
11. Press briey the P3 button.
12. Set the ton1 time to the desired value.
13. Press briey the P3 button.
14. Set the ton2 time to the desired value.
15. Press briey the P3 button.
16. Set the tdLY time to the desired value.
17. Press briey the P3 button.
18. Press briey the P3 button.
PROGRAMMING RECEIVER 2 - STEP BY STEP
1. Press briey the P1 button. The display shows rad1.
2. Press the button of the transmitter #2. The display shows done.
3. Press the button of the transmitter #3. The display shows done.
4. To quit, press briey the P1 button.
5. Press briey the P2 button. The display shows rad2.
6. Press the button of the transmitter #1. The display shows done.
7. Press the button of the transmitter #4. The display shows done.
8. To quit, press briey the P2 button.
9. To enter the menu, press briey the P3 button.
10. Set the item funCt to 4.
11. Press briey the P3 button.
12. Set the ton1 time to the desired value.
13. Press briey the P3 button.
14. Set the ton2 time to the desired value.
15. Press briey the P3 button.
16. Set the tdLY time to the desired value.
17. Press briey the P3 button.
18. Press briey the P3 button.

7/8
6-1620026 rev.P4 22/02/2016
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Time Clock
or
Access Control
12-24 Vac/Vdc
Power for Strike
Door operator
Electric Strike
Transmitter
PUSH
TO OPEN
12 MODE 5 - LATCHED MODE OPTION (1)
MODE 5 - Latched mode 1
Program Access Control (or Time Clock) on the relay 1 and the transmitters on the relay 2.
Access Control (or Time Clock) activates the relay 1 with a Step-by-Step command. To deactivate the relay 1, give another command with Access
Control (or Time Clock).
The transmitters activate the relay 2 for the
TON2
time, only with the relay 1 activated.
PROGRAMMING - STEP BY STEP
1. Press briey the P1 button. The display shows rad1.
2. Give a command with the Access Control (or Timed Clock). The display shows done.
3. To quit, press briey the P1 button.
4. Press briey the P2 button. The display shows rad2.
5. Press the button of the transmitter. The display shows done.
6. To quit, press briey the P2 button.
7. To enter the menu, press briey the P3 button.
8. Set the item funCt to 5.
9. Press briey the P3 button.
10. Press briey the P3 button.
11. Set the ton2 time to the desired value.
12. Press briey the P3 button.
13. Press briey the P3 button.
14. Press briey the P3 button.

8/8 6-1620026 rev.P4 22/02/2016
1 2 3 87654
RELAY 1 RELAY 2
P2P1 P3
POTENTIOMETER
DISPLAY
OUT1 OUT2
MEMORY
RADIO MODULE
12-24 Vac/Vdc
Power Supply
Door operator
Electric Strike
Transmitter
12-24 Vac/Vdc
Power for Strike
PUSH
TO OPEN
13
14
7380 S. Eastern Ave, Ste 124-320
Las Vegas, NV 89123
(866) 975-0101 - (866) 975-0404 Fax
www.transmittersolutions.com
NOTICE
Any changes or modication to the equipment not expressly approved by Transmitter Solutions could void the manufacturer’s warranty and the
user’s authority to operate this product.
WARRANTY
The warranty period of Transmitter Solutions receiver is twenty-four (24) months. This warranty shall begin on the date the receiver is
manufactured. During the warranty period, the product will be repaired or replaced (at the sole discretion of Transmitter Solutions) if the product
does not operate correctly due to a defective component. This warranty does not extend to (a) the receiver case, which can be damaged by
conditions outside the control of Transmitter Solutions.
WARRANTY
MODE 6 - LATCHED MODE OPTION (2)
MODE 6 - Latched mode 2
You must program the transmitters on the relay 1.
The transmitter activates the relay 1 for the
TON1
time. Then, after the
TDLY
time, it activates the relay 2.
To disable the relay 2, use again the transmitter.
PROGRAMMING - STEP BY STEP
1. Press briey the P1 button. The display shows rad1.
2. Press the button of the transmitter. The display shows done.
3. To quit, press briey the P1 button.
4. To enter the menu, press briey the P3 button.
5. Set the item funCt to 6.
6. Press briey the P3 button.
7. Set the ton1 time to the desired value.
8. Press briey the P3 button.
9. Press briey the P3 button.
10. Set the tdLY time to the desired value.
11. Press briey the P3 button.
12. Press briey the P3 button.
Table of contents
Other Transmitter Solutions Receiver manuals