Wall-mounted encoding photo eyes with Transmitter operated by solar panel and re-chargeable battery, with 180°
rotation and range of up to 35 feet.
The iGAZES035 Solar photo eye solves problems related to installing electrical cables to connect the transmitter
and receiver. It is also possible to install 2 pairs of the same model without any interference between them if they
are encoded accordingly at the time of installation.
TT EECCHHNN IICCAA LL DD AATT AA ::
- Max. range : 35 feet
- TX power supply : 1 1.2V Re -chargeable AA battery
- RX power supply : 12 -24 VAC/DC
- TX absorption : 0.30 mA Max.
- RX absorption : 25 mA Max.
- Relay contact rating : 1A max at 30 VDC
- Operating temperature : -4˚F to 131˚F
- Container : Polycarbonate
- Protection rating : NEMA 4 X(IP 54)
- Container dimensions : 1 x 3 x 1 inches
DDEESSCCRRIIPPTT IIOONN OOFF TT HHEE TT RRAA NNSSMMIITT TT EERR (( TT XX )) ::
PPoo ww eerr ssuu pp pp llyy and operation:
Thetransmitter is powered by a solar panel mounted on the cover and a 1.2 Volt re -chargeable battery that allows
it to operate in the absence of light.
SSeellee cctt iinngg tt hhee OOppee rraatt iinngg RRaannggee (( SSWW11 DDiipp SSwwiitt cchh NNoo.. 11 )) ::
The maximum distance of operation of the battery-operated photo eye is approximately 35 feet (10 meters) at normal
power (Dip Switch No. 1 OFF “factory configuration”) and approximately 65 feet (20 meters) at maximum power
(Dip Switch No. 1 ON).
SSeellee cctt iinngg OOppee rraatt iinngg CCooddee ““ AA ”” aanndd ““ BB ““ (( SSWW11 DDiipp SSwwiitt cchh NNoo.. 22 )) ::
The photo eye has two operating encoding channels "A" and "B", in this way it is possible to install 2 pairs of the
same model without any interference between them. Code "A" ( Dip Switch No. 2 OFF “factory configuration” ) or
code “B” ( Dip Switch No. 2 ON ), must be accordingly selected in the same way, at the time of installation, on
both the transmitter and receiver.
IImmppoorrtt aanntt ::
It is possible to connect a "N.C." safety device to the transmitter (for example a
safety edge mounted on the leading edge of a sliding gate):when the contact
iGAZES035
Solar Powered Photo Eyes
If no "N.C." safety device is used (eg. safety edge),
inputs 3 and 4 must always be jumpered.
CCoonnnneecctt iioonnss::
1 - Connection for red wire ( + ) Solar Panel.
2 - Connection for black wire ( - ) Solar Panel.
3 - "N.C."safety device (Jumper only if not used)
4 - "N.C."safety device (Jumper only if not used)
3545
23
ON
CN1
1 2
ON
1 2
JUMPER
opens the transmitter stops transmitting.