Delta OHM HD2013.3 User manual

Operating manual
Precipitation detector
HD2013.3
www.deltaohm.com
English
Keep for future reference.

HD2013.3 - 2 - V1.7
TABLE OF CONTENTS
1 INTRODUCTION ........................................................................................ 3
2 TECHNICAL SPECIFICATIONS ...................................................................
3 INSTALLATION ......................................................................................... 6
3.1 ELECTRICAL CONNECTIONS .......................................................................... 6
CONFIGURATION AND MEASUREMENT ..................................................... 9
5 PROPRIETARY PROTOCOL ...................................................................... 10
6 MODBUS-RTU PROTOCOL ........................................................................ 17
7 MAINTENANCE ........................................................................................ 21
8 SAFETY INSTRUCTIONS .......................................................................... 21
9 ORDERING CODES .................................................................................. 22

HD2013.3 - 3 - V1.7
1 INTRODUCTION
HD2013.3 is a precipitatio detector based o the capacitive pri ciple. The capacity
value of the se sitive eleme t cha ges accordi g to the surface dampe ed by
rai drops.
A i tegrated heater keeps the detector dry, evaporates water a d preve ts false sig-
als caused by fog or dew. The heater also activates at low temperatures, melti g the
s ow a d allowi g detecti g s ow precipitatio s by usi g a ambie t temperature
se sor.
The i strume t exter al circular dome acts as a wi dshield for the se sor, preve ti g
false i dicatio s.
A auto-calibratio algorithm compe sates for variatio s i the respo se due to the
dirt that ca accumulate o the se sitive surface.
The i strume t has a digital RS485 output with MODBUS-RTU or proprietary protocol,
a 0/4…20 mA (0…10 V on request when ordering) a alog output a d a voltage-free
co tact output. The co tact output is activated whe the se sor detects a precipita-
tio i progress.
The detector has IP68 protectio degree.
Supplied with fixi g bracket for ∅ 30…50 mm mast.
Optio al bird spikes (to be requested whe orderi g the detector) ca be mou ted.

HD2013.3 - 4 - V1.7
2TECHNICAL SPECIFICATIONS
Precipitation sensor
Type Capacitive, with i tegrated heater
Dime sio s 6.6 cm2
A gle 30°
Se sitive area 0.05 cm2 mi .
Temperature sensor NTC 10KΩ @ 25 °C
Measuring range
Precipitatio detectio ON / OFF (precipitatio i progress / o precipitatio )
Perce tage of dry se sitive surface of the se sor
Temperature -40…+60 °C
Resolution
Precipitatio detectio Co figurable 1 % (default) or 0.1 % of dry se sitive surface
of the se sor
Temperature 0.1 °C
Output RS485 ot isolated, with MODBUS-RTU or proprietary protocol
A alog 0/4…20 mA (RLmax = 500 Ω) or o request
0…10 V
(RLmi = 10 kΩ)
Voltage-free ormally ope co tact
max. 200 mA @ 30 Vdc
resistive load
Power supply 12…30 Vdc
Consumption With heati g OFF: 18 mA @24 Vdc
With heati g ON: 230 mA max @24 Vdc
The i dicated co sumptio does ot i clude the co sumptio
due to the a alog output
Connection 8-pole circular co ector
Operating conditions -40…+60 °C / 0…100 %RH
Storage temperature -40…+60 °C
Dimensions ∅ 70 x 70 mm (o ly the i strume t without mou ti g bracket)
Weight 450 g approx.
Protection degree IP 68
Housing material Tech opolymer ASA

HD2013.3 - 5 - V1.7
Fig. 2.1: dimensions (mm)
Bird spikes (option
a
l)
Bracket

HD2013.3 - 6 - V1.7
3INSTALLATION
Use the supplied accessories to mou t the i strume t. The bracket ca be fixed to a ∅
30…50 mm mast, both vertical a d horizo tal, tha ks to the double drilli g o the
bracket.
Fig. 3.1: installation on vertical mast
Place the detector far from buildi gs, trees, etc…, taki g care that the space above is
free from a y object that could obstruct the detectio of the precipitatio . Keep the
se sor clea .
3.1 ELECTRICAL CONNECTIONS
The i strume t has a 8-pole circular co ector a d uses the CP2013.2... optional ca-
bles, with 8-pole co ector o o e side a d ope wires o the other side.
Fig. 3.2: connectors pinout
HD2013.3
Bracket
Mast
Connector
Screws for fixing the
detector to the bracket
Ring for fixing the
bracket to the mast
Co ector refere ce
I strume t male
co ector (exter al view)
Cable female co ector
(exter al view)

HD2013.3 - 7 - V1.7
Connector Function Wire color
CP2013.2… cable
1 Voltage-free co tact Gree
2 Power supply positive (+Vdc) Red
3 RS485 B/+ White
4 Voltage-free co tact Blue
5 RS485 A/- Brow
6 A alog output positive Yellow
7 Power supply egative (GND) Grey
8 Serial grou d Black
To e sure a good oise immu ity, it is recomme ded to co ect the cable shield to
grou d (GND).
RS 85 connection:
By default, the i strume t has MODBUS address 1 a d commu icatio parameters
19200, 8E1. Differe t parameters ca be set usi g the proprietary protocol or the
MODBUS-RTU protocol.
Fig. 3.3: RS 85 connection
Current analog output:
By default, the curre t a alog output is 4…20 mA, with:
4 mA = se sor se sitive surface completely wet
20 mA = se sor se sitive surface completely dry
With the comma ds of the proprietary protocol it is possible to set the ra ge 0…20 mA
for the output a d reverse the directio of the output, so that whe the se sor se si-
tive surface is completely wet the output is 20 mA.
I case of measureme t error, the output goes to 22 mA.
Power supply
12…30 Vdc
Red
Grey
Brow
White
CP2013.2… cable
PLC, data logger or
RS485/USB or RS485/RS232
co verter for PC
Other se sors with
RS485 output
Termi atio Termi atio

HD2013.3 - 8 - V1.7
Fig. 3. : current analog output connection
Voltage analog output (optional):
By default, the voltage a alog output is 0…10 V, with:
0 V = se sor se sitive surface completely wet
10 V = se sor se sitive surface completely dry
With the comma ds of the proprietary protocol it is possible to set the ra ge 2…10 V
for the output a d reverse the directio of the output, so that whe the se sor se si-
tive surface is completely wet the output is 10 V.
I case of measureme t error, the output goes to 11 V.
Fig. 3.5: voltage analog output connection
Contact output:
There is a ormally ope voltage-free co tact betwee pi s 1 a d 4 of the co ector
(gree a d blue wires of the optio al CP2013.2… cable). The co tact closes whe the
se sor detects a precipitatio i progress.
Power supply 12…30 Vdc
CP2013.2… cable
Red
Grey
Yellow
Power supply 12…30 Vdc
CP2013.2… cable
Red
Grey
Yellow RLmi = 10 kΩ
RLmax = 500 Ω

HD2013.3 - 9 - V1.7
CONFIGURATION AND MEASUREMENT
The co figuratio of the i strume t a d the readi g of the measureme ts ca be do e
via the RS485 serial output, both with the proprietary protocol a d with the MODBUS-
RTU protocol.
I the first 10 seco ds after the i strume t power o , it is always active the proprie-
tary protocol. After 10 seco ds from power o , the operati g protocol is activated,
which by default is the MODBUS-RTU protocol.
It is possible to keep the proprietary protocol active eve after 10 seco ds from power o
by se di g, before the 10 seco ds expire, the comma d @ of the proprietary protocol.
The proprietary protocol ca be set as operati g protocol by mea s of the CP0 comma d.
The comma ds of the proprietary protocol a d the registers of the MODBUS-RTU pro-
tocol are described i detail i the followi g chapters.
Precipitation measurement:
To determi e if a precipitatio is i progress, the i strume t detects the perce tage of
dry se sitive surface of the se sor:
100% = se sitive surface of the se sor completely dry
0% = se sitive surface of the se sor completely wet
Whe the perce tage of dry se sitive surface of the se sor falls below a co figurable
threshold value (default 95%), the i strume t i dicates that a precipitatio is i pro-
gress. The threshold value ca be modified with the comma d CRT of the proprie-
tary protocol or by usi g the MODBUS holdi g register with address 5.
The i dicatio of precipitatio i progress ceases whe the perce tage of dry se sitive
surface of the se sor rises above the threshold plus a co figurable hysteresis value
(default 2%) a d after a co figurable delay time (default 2 mi utes).
The resolutio with which the perce tage of dry se sitive surface of the se sor is de-
tected is 1% by default. The resolutio ca be set to 0.1% with the comma d CRLR
of the proprietary protocol or by usi g the MODBUS holdi g register with address 16.
The i strume t discrimi ates betwee rai fall a d s owfall based o the measured
ambie t temperature. If the ambie t temperature is lower tha a co figurable refer-
e ce temperature (default 2 °C), the precipitatio is co sidered s owy.
The detectio se sitivity ca be adjusted with the comma d DRS of the proprietary
protocol or by usi g the MODBUS holdi g register with address 20.
Automatic calibration of the precipitation sensor:
The i strume t ca be set so as the precipitatio se sor calibratio is automatically
performed at regular i tervals; this allows compe sati g for a y drift of the se sor
due to temperature cha ges, agi g a d dirt deposited o the se sitive surface.
The correctio applied by each automatic calibratio is limited to a maximum value
(co figurable), so as to avoid erro eous calibratio s whe the detected value differs too
much from the estimated value.
By default, the automatic calibratio is e abled, with 30 mi utes i terval a d 0.1%
maximum correctio . I order to cha ge the automatic calibratio setti gs, see the
chapters o the proprietary protocol a d MODBUS-RTU protocol.

HD2013.3 - 10 - V1.7
5PROPRIETARY PROTOCOL
To use the proprietary protocol, it is ecessary to co ect the i strume t to the PC via
a RS485/USB (e.g. RS51K) or RS485/RS232 co verter a d use a sta dard serial
commu icatio program. I the serial commu icatio program, set the COM port
umber to which the i strume t is co ected a d the commu icatio parameters as
follows:
•If the MODBUS-RTU protocol is set as the operati g protocol i the i strume t
(default), set the Baud Rate 57600 a d the parameters 8N2 i the serial commu-
icatio program, the power cycle the i strume t a d se d the comma d @
withi 10 seco ds from the i strume t power o .
•If the proprietary protocol is already set as the operati g protocol i the i stru-
me t, it is possible to operate with Baud Rate 57600 a d parameters 8N2 by
se di g the comma d @ withi 10 seco ds from the i strume t power o , or
you ca let the 10 seco ds pass without se di g the comma d @ a d operate
with the commu icatio parameters set i the i strume t (default 19200, 8E1).
To cha ge the i strume t co figuratio , the serial comma d CAL USER ON must be
se t first (the i strume t replies with USER CAL MODE ON). The comma d CAL USER ON
is automatically disabled after a few mi utes of i activity. If the setti gs should be o ly
read, the comma d CAL USER ON is ot required.
Below is the list of the serial comma ds.
Instrument information:
Command Reply Description
G0 Model I strume t model
G1 &Revision| I strume t hardware revisio
G2 SN= I strume t serial umber
G3 Firm.Ver.=x.y I strume t firmware revisio
G4 Firm.Date=yyyy/mm/dd Date of firmware revisio
GC Fact.Calib.Date= yyyy/mm/dd Date of factory calibratio
Protocol:
Command Reply Description
@ &| Keeps the proprietary protocol operatio al eve after 10
seco ds from i strume t power o . It must be se t withi
10 seco ds from i strume t power o .
CP &| Sets the operati g protocol:
Proprietary if =0
MODBUS-RTU if =1
Default : MODBUS-RTU ( =1)
RP & | Reads the operati g protocol set i the i strume t.
SM &| Activates the MODBUS-RTU protocol immediately.
CMA &| Sets the i strume t address for the MODBUS-RTU pro-
tocol to .
The address should ra ge withi 1 a d 247.
Default : 1
RMA & | Reads the i strume t address for the MODBUS-RTU pro-
tocol.
Note: after se di g the CP1 comma d, the i strume t remai s with the proprietary protocol.
Se d the comma d SM to activate the MODBUS-RTU protocol immediately, or power cycle the

HD2013.3 - 11 - V1.7
i strume t.
RS 85 communication parameters:
Command Reply Description
CMB &| Sets the Baud Rate:
1200 if =0
2400 if =1
4800 if =2
9600 if =3
19200 if =4
38400 if =5
57600 if =6
115200 if =7
Default : 19200 ( =4)
RMB & | Reads Baud Rate setti g
CMP &| Sets parity a d stop bits:
8N1 if =0 [No parity, 1 stop bit]
8N2 if =1 [No parity, 2 stop bits]
8E1 if =2 [Eve parity, 1 stop bit]
8E2 if =3 [Eve parity, 2 stop bits]
8O1 if =4 [Odd parity, 1 stop bit]
8O2 if =5 [Odd parity, 2 stop bits]
The umber of data bits is fixed to 8.
Default : 8E1 ( =2)
RMP & | Reads the setti g of parity a d stop bits.
CMW &| Sets waiti g time after tra smissio with MODBUS-RTU
protocol:
Immediate receptio if =0 (violates protocol)
Waiti g 3.5 characters if =1 (respects protocol)
Default : Immediate receptio ( =0)
RMW & | Reads the setti g of waiti g time after tra smissio with
MODBUS-RTU protocol.
Precipitation detection settings:
Command Reply Description
CRLR &| Sets the resolutio with which the perce tage of dry
se sitive surface of the se sor is detected:
1% if =0
0.1% if =1
Default : 1% ( =0)
RRLR & | Reads the resolutio with which the perce tage of dry
se sitive surface of the se sor is detected.
CRT &| Sets the precipitatio detectio threshold to value,
where is the perce tage of dry se sitive surface of the
se sor below which the i strume t i dicates that a pre-
cipitatio is i progress.
If the 0.1% resolutio is set, the value must be ex-
pressed i te ths (for example, write 970 to i dicate
97.0%).
Default : 97 (=97% with 1% default resolutio )
RRT & | Reads the setti g of the precipitatio detectio thresh-
old.

HD2013.3 - 12 - V1.7
Command Reply Description
CRH &| Sets the hysteresis of the precipitatio detectio thresh-
old to value.
The value should ra ge withi 0 a d 20%.
If the 0.1% resolutio is set, the value must be ex-
pressed i te ths (for example, write 10 to i dicate
1.0%).
Default : 1 (=1% with 1% default resolutio )
RRH & | Reads the setti g of the hysteresis of the precipitatio
detectio threshold.
CST &| Sets the refere ce temperature to discrimi ate betwee
rai fall a d s owfall to value expressed i te ths of °C.
The value should ra ge withi -50 (=-5 .0 °C) a d 50
(=+5.0 °C).
Default : 20 (=+2.0 °C)
RST & | Reads the setti g of the refere ce temperature to dis-
crimi ate betwee rai fall a d s owfall.
CSH &| Sets the hysteresis of the refere ce temperature to dis-
crimi ate betwee rai fall a d s owfall to value ex-
pressed i te ths of °C.
The value should ra ge withi -5 (=-0 ,5 °C) a d 5
(=+0,5 °C).
Default : 5 (=+0,5 °C)
RSH & | Reads the setti g of the hysteresis of the refere ce tem-
perature to discrimi ate betwee rai fall a d s owfall.
CRAD &| Sets the delay i i dicati g the begi i g of a precipita-
tio , both rai y a d s owy, to seco ds (0…32767 s).
The i dicatio of precipitatio i progress is ge erated
o ly if the precipitatio lasts lo ger tha the set time.
Default: 0
RRAD & | Reads the setti g of the delay i i dicati g the begi i g
a precipitatio .
CRAB &| Sets the delay i i dicati g the e d of a precipitatio ,
both rai y a d s owy, to seco ds (0…32767 s).
The i dicatio of precipitatio i progress ceases o ly af-
ter the set time has elapsed from the e d of the precipita-
tio .
Default: 120
RRAB & | Reads the setti g of the delay i i dicati g the e d of a
precipitatio .
CTAD &| Sets the delay i i dicati g the tra sitio from rai fall to
s owfall, whe the temperature dops below the refere ce
temperature, to seco ds (0…32767 s).
Default: 0
RTAD & | Reads the setti g of the delay i i dicati g the tra sitio
from rai fall to s owfall, whe the temperature dops be-
low the refere ce temperature.

HD2013.3 - 13 - V1.7
Command Reply Description
CTAB &| Sets the delay i i dicati g the tra sitio from s owfall
to rai fall, whe the temperature rises above the refer-
e ce temperature plus the hysteresis, to seco ds
(0…32767 s).
Default: 0
RTAB & | Reads the setti g of the delay i i dicati g the tra sitio
from s owfall to rai fall, whe the temperature rises
above the refere ce temperature plus the hysteresis.
DRS &| Sets the se sitivity of the precipitatio detectio to
value (10…1000). The greater the value, the greater
the se sitivity.
Default : 100
GRS & | Reads the setti g of the se sitivity of the precipitatio
detectio .
Contact output:
Command Reply Description
CRS &| Sets the co tact output activatio mode:
Output disabled if =0
Output activated i case of rai fall if =1
Output activated i case of s owfall if =2
Note: the precipitatio is co sidered a rai fall if the
measured temperature is higher tha the refere ce
temperature, a d a s owfall if the measured tempera-
ture is lower tha the refere ce temperature.
Default : Output activated i case of rai fall ( =1)
RRS & | Reads the setti g of the co tact output activatio mode.
Analog output:
Command Reply Description
CAOE &| Adds the offset to the a alog output: 4…20 mA or 2…10 V.
CAOD &| Remove the offset from the a alog output: 0…20 mA or
0…10 V.
CAOR & | Reads the setti g of the offset for the a alog output:
Without offset if =0 (default for voltage output)
With offset if =1 (default for current output)
CASE &| Sets the followi g correspo de ce for the a alog output:
4 mA / 0 V 100% of dry se sitive surface
20 mA / 10 V 0% of dry se sitive surface
CASD &| Sets the followi g correspo de ce for the a alog output:
4 mA / 0 V 0% of dry se sitive surface
20 mA / 10 V 100% of dry se sitive surface
CASR & | Reads the setti g of the correspo de ce betwee a alog
output a d perce tage of dry se sitive surface:
4…20 mA / 0…10 V 0…100% if =0 (default)
4…20 mA / 0…10 V 100…0% if =1

HD2013.3 - 14 - V1.7
Units of measurement:
Command Reply Description
TT &| Sets the temperature u it of measureme t:
°C if =0
°F if =1
Default : °C ( =0)
HH & | Reads the setti g of the temperature u it of measure-
me t.
Reading of the measurement information:
Command Reply Description
S0 &| Disable the se di g of the measureme t i for-
matio .
S1 &| E able the se di g of the measureme t i for-
matio at regular i tervals.
To set the se di g i terval, use the comma d MT.
For the mea i g of the i formatio se t by the
i strume t, see the comma d S2.
S2 & RAIN_RAW
RAIN_LEVEL
RAIN_STATUS
RAIN_VALIDITY
PRECIPITATION_TYPE
AMB_TEMP VOLTAGE
HEATER_TEMP
MICRO_TEMP
HEATER_MODE
HEATER_PERCENTAGE|
Pri ts the list of the measureme t i formatio
se t by the i strume t:
RAIN_RAW = umber of 12-bit ADC cou ts,
proportio al to the perce tage of dry se sitive
surface of the se sor
RAIN_LEVEL = perce tage of dry se sitive surface
of the se sor
RAIN_STATUS = i dicatio of o precipitatio (0)
or precipitatio i progress (1)
RAIN_VALIDITY = validity of the precipitatio
i dicatio (0= o, 1=yes)
PRECIPITATION_TYPE = i dicatio of the type of
precipitatio (0=rai fall, 1=s owfall)
AMB_TEMP = ambie t temperature
VOLTAGE = power supply voltage
HEATER_TEMP = heater temperature
MICRO_TEMP = i ter al board temperature
HEATER_MODE = heati g operati g mode
HEATER_PERCENTAGE = perce tage of heati g
power used
MT &| Sets the i terval for se di g the measureme t i -
formatio to seco ds (1…30 s).
Default: 1
NT & | Reads the setti g of the i terval for se di g the
measureme t i formatio .

HD2013.3 - 15 - V1.7
Heating:
Command Reply Description
CHM &| Sets the heati g operati g mode:
Ma ual if =0
Always o if =1
Always off if =2
Automatic if =3
If the ma ual mode is set, the heati g power set with
the comma d CHP is used.
Default : Automatic ( =3)
RHM & | Reads the setti g of the heati g operati g mode.
CHP &| Sets the heati g power for the ma ual operati g mode
to value, as a perce tage of the maximum power
(0…100%)
Default : 50 (=50% of the maximum power)
RHP & | Reads the setti g of the heati g power for the ma ual
operati g mode.
Advanced functions:
Command Reply Description
DFLT &| Restores the factory co figuratio .
CU4 &| Calibrates the i strume t.
Se d the comma d o ly if the se sor se sitive surface
is completely dry.
CRBS &| E able/disable the precipitatio se sor automatic cali-
bratio at regular i tervals:
Disable if =0
E able if =1
Default : Automatic calibratio e abled
RRBS & | Reads the e abli g status of the precipitatio se sor au-
tomatic calibratio .
CRBT &| Sets the time i terval betwee two co secutive precipi-
tatio se sor automatic calibratio s to seco ds
(300…64800 s).
Default: 1200 (=20 mi utes)
RRBT & | Reads the setti g of the time i terval betwee two co -
secutive precipitatio se sor automatic calibratio s.
CRBMC &| Sets the maximum correctio that ca be applied by each
precipitatio se sor automatic calibratio to value ex-
pressed i te ths of %.
The value should ra ge withi 1 (=0.1%) a d 200
(=20.0%).
Default: 4 (=0.4%)
RRBMC & | Reads the maximum correctio that ca be applied by
each precipitatio se sor automatic calibratio .

HD2013.3 - 16 - V1.7
Command Reply Description
CHDT &| Sets the temperature differe ce (ΔT) that is mai tai ed
betwee the se sor heated base, i the automatic heat-
i g operati g mode, a d the e viro me t to value ex-
pressed i te ths of °C.
Note: the greater the ΔT, the greater the dryi g speed of
the se sor a d the greater the detectio of the e d of
precipitatio ; o the other ha d, the greater the possibil-
ity that a very light precipitatio is ot detected or causes
a oscillatio i i dicati g the prese ce/abse ce of pre-
cipitatio . The ΔT setti g is therefore a compromise be-
twee opposite eeds. If the differe ce ΔT is too low,
co de satio ca form o the se sor surface, which ca
be detected as precipitatio .
Default: 250 (=25.0 °C)
RHDT & | Reads the setti g of the temperature differe ce (ΔT) that
is mai tai ed betwee the se sor heated base a d the
e viro me t.
GRC & x y| Reads the umber of reboots (x) a d watchdog timeouts
(y) that occurred.

HD2013.3 - 17 - V1.7
6MODBUS-RTU PROTOCOL
By default, the i strume t has MODBUS address 1 a d commu icatio parameters
19200, 8E1. The address a d the commu icatio parameters ca be cha ged by usi g
the appropriate serial comma ds of the proprietary protocol or, alter atively, directly
with MODBUS comma ds by cha gi g the value of the Holdi g Registers described
later.
The MODBUS-RTU protocol, if set as the operati g protocol (default), is active after 10
seco ds from the i strume t power o .
I order to cha ge the i strume t co figuratio usi g the MODBUS-RTU protocol, the
value 1 must be writte first i the Coil umber with address 1.
Below is the list of registers.
Discrete inputs:
Address Description Format
0 I dicatio of o precipitatio (0) or precipitatio i progress (1). Bit
1 Validity of the precipitatio i dicatio : 0= o, 1=yes. Bit
2 I dicatio of the type of precipitatio :
0=rai fall, 1=s owfall.
Bit
Input Registers:
Address Description Format
0 I strume t model ide tificatio . 16-bit I teger
1 I strume t hardware revisio . 16-bit I teger
2,3 I strume t serial umber. (*) 16-bit I teger
4 I strume t firmware revisio . The most sig ifica t byte i dicates
the major revisio ; the less sig ifica t byte i dicates the mi or
revisio .
16-bit I teger
5 Number of reboots that occurred. 16-bit I teger
6 Number of watchdog timeouts that occurred. 16-bit I teger
7 Power supply voltage i Volt (x10). 16-bit I teger
8 I ter al board temperature (x10). 16-bit I teger
9 Number of 12-bit ADC cou ts, proportio al to the perce tage of
dry se sitive surface of the se sor.
16-bit I teger
10 Perce tage of dry se sitive surface of the se sor (x10 if the reso-
lutio is 0.1%).
16-bit I teger
11 Number of MODBUS commu icatio error. 16-bit I teger
12 Ambie t temperature (x10). 16-bit I teger
13 Heater temperature (x10). 16-bit I teger
14 Perce tage of heati g power used. 16-bit I teger
15 I dicatio of precipitatio abse t/i progress a d type of precipi-
tatio :
0= o precipitatio
1=rai fall
2=s owfall
16-bit I teger

HD2013.3 - 18 - V1.7
(*) The I strume t serial umber has 8 digits. Two co secutive registers must be accessed to
read the umber. The register with lower address co tai s the most sig ifica t 4 digits.
Coils:
Address Description Format
0 Set 1 to restore the factory co figuratio . Bit zeroi g is automatic. Bit
1 E able co figuratio cha ge:
0= o (default), 1=yes.
The cha ges to Coils a d Holding Registers will be accepted o ly
if this register is set to 1.
Bit
2 Sets waiti g time after tra smissio with MODBUS-RTU protocol:
0=immediate receptio (default);
1=waiti g 3.5 characters.
Bit
3 Set 1 to calibrate the i strume t. Bit zeroi g is automatic.
Set 1 o ly if the se sor se sitive surface is completely dry.
Bit
Holding Registers:
Address Description Format
0 RS485 Baud Rate:
0=1200;
1=2400;
2=4800;
3=9600;
4=19200 (default);
5=38400;
6=57600;
7=115200.
16-bit I teger
1 RS485 parity a d stop bits:
0=8N1;
1=8N2;
2=8E1 (default);
3=8E2;
4=8O1;
5=8O2.
[N= o parity, E=eve parity, O=odd parity]
16-bit I teger
2 I strume t address for the MODBUS-RTU protocol (1…247, de-
fault=1).
16-bit I teger
3 Heati g operati g mode:
0= Ma ual;
1= Always o ;
2= Always off;
3= Automatic (default).
If the ma ual mode is set, the heati g power set i the ext reg-
ister is used.
16-bit I teger
4 Heati g power for the ma ual operati g mode as a perce tage
of the maximum power (default=50%).
16-bit I teger
5 Precipitatio detectio threshold as a perce tage (x10 if the
resolutio is 0.1%) of dry se sitive surface of the se sor below
which the i strume t i dicates that a precipitatio is i progress
(default=97%).
16-bit I teger
6 Hysteresis (x10 if the resolutio is 0.1%) of the precipitatio de-
tectio threshold (0…20%, default=1%).
16-bit I teger

HD2013.3 - 19 - V1.7
Address Description Format
7 Precipitatio detectio i terval (1…30 s, default=1 s). 16-bit I teger
8 Refere ce temperature, expressed i te ths of the set u it of
measureme t, to discrimi ate betwee rai fall a d s owfall
(-50…+50=-5.0…+5.0 °C, default=+2.0 °C).
16-bit I teger
9 Hysteresis of the refere ce temperature, expressed i te ths of
the set u it of measureme t, to discrimi ate betwee rai fall a d
s owfall (-5…+5=-0.5…+0.5 °C, default=+0.5).
16-bit I teger
10 Delay i i dicati g the begi i g of a precipitatio , both rai y
a d s owy (0…32767 s, default 0).
The i dicatio of precipitatio i progress is ge erated o ly if the
precipitatio lasts lo ger tha the set time.
16-bit I teger
11 Delay i i dicati g the e d of a precipitatio , both rai y a d
s owy (0…32767 s, default 120 s).
The i dicatio of precipitatio i progress ceases o ly after the set
time has elapsed from the e d of the precipitatio .
16-bit I teger
12 Delay i i dicati g the tra sitio from rai fall to s owfall, whe the
temperature dops below the refere ce temperature (0…32767 s,
default 0).
16-bit I teger
13 Delay i i dicati g the tra sitio from s owfall to rai fall, whe
the temperature rises above the refere ce temperature plus the
hysteresis (0…32767 s, default 0).
16-bit I teger
14 Temperature u it of measureme t: 0=°C, 1=°F (default °C). 16-bit I teger
15 Co tact output activatio mode:
0= Output disabled;
1= Output activated i case of rai fall (default);
2= Output activated i case of s owfall.
Note: the precipitatio is co sidered a rai fall if the measured
temperature is higher tha the refere ce temperature, a d a
s owfall if the measured temperature is lower tha the refere ce
temperature.
16-bit I teger
16 Resolutio with which the perce tage of dry se sitive surface of
the se sor is detected:
0= 1% (default); 1= 0.1%.
16-bit I teger
17 E able the precipitatio se sor automatic calibratio at regular
i tervals: 0= o, 1=yes (default).
16-bit I teger
18 Time i terval betwee two co secutive precipitatio se sor au-
tomatic calibratio s (300…64800 s, default 1200=20 mi utes).
16-bit I teger
19 Maximum correctio that ca be applied by each precipitatio
se sor automatic calibratio expressed i te ths of %
(1…200=0.1…20.0%, default=4).
16-bit I teger
20 Temperature differe ce (ΔT) that is mai tai ed betwee the se sor
heated base, i the automatic heati g operati g mode, a d the e -
viro me t expressed i te ths of °C (default 250=25.0 °C).
Note: the greater the ΔT, the greater the dryi g speed of the se -
sor a d the greater the detectio of the e d of precipitatio ; o
the other ha d, the greater the possibility that a very light pre-
cipitatio is ot detected or causes a oscillatio i i dicati g the
prese ce/abse ce of precipitatio . The ΔT setti g is therefore a
compromise betwee opposite eeds. If the differe ce ΔT is too
low, co de satio ca form o the se sor surface, which ca be
detected as precipitatio .
16-bit I teger

HD2013.3 - 20 - V1.7
Address Description Format
21 Se sitivity of the precipitatio detectio (10…1000, default 100).
The greater the value, the greater the se sitivity.
16-bit I teger
Table of contents
Popular Security Sensor manuals by other brands

Niko
Niko 350-41601 Technical manual

System Sensor
System Sensor DUCTSD240 Installation and maintenance instructions

ITALIANA SENSORI
ITALIANA SENSORI ISR049 Installation, operation and maintenance manual

ABB
ABB Orion3 Extended Original instructions

howen
howen Hero-TD01-G user manual

ELREHA
ELREHA EGS 101 quick start guide