Outdoor/Indoor Window and
Sliding Door Dual Detector with
Anti-Masking and Pet Immunity
NV35MX-EI01
General Description
Thank you for choosing the NV35MX for your professional protection
needs. The NV35MX EVO version will provide you the most advanced
window and sliding door protection either in Pet Immune or Sharp mode,
while programming can be done remotely via EVO bus connection. If you
have any comments please write to us at Paradox.com/products/
feedback.This guide describes how to install and program the NV35MX.
Pet Recommended Installation (please read)
The NV35MX has been designed to be installed within the frame of
windows and doors when installed outdoors. This will ensure the best
performance against false alarms when random pets such as birds, cats
and small dogs access the window sill. Other installation methods can be
used with the NV35MX such as wall beam protection but if installed
outside of the frame its pet immunity may be compromised.
Installing the NV35MX
1. Remove the NV35MX front cover - open the Captive screw.
2. Remove the Main Unit: open the two snap-lock mechanisms on each
side of the back cover attaching the Main Unit to the back cover as
displayed below. Then remove the Main Unit.
Figure 3 – Removing the Main Unit
3. Pull the wires from the control panel through the knockout holes and
mount the back cover onto the window frame or wall using screws.
Figure 4 – Mounting the Back Cover
4. Attach the Main Unit to the back cover - ensure the locks snap closed.
Figure 5 – Attaching the Main Unit
5. Connect the wires to the terminal blocks according to the following
wiring assignment.
Table 1: Wiring Assignment
6. Replace the front cover and close the Captive screw.
Warning: Do not obscure the detector's field of view.
Programming the NV35MX
Program the detector with a keypad or BabyWare software.
Programming with a Keypad
1. Enter EVO Installer Programming Mode.
2. Enter Module Programming:
aEntersection[4003] in the Enter Section field.
b Enter the detector’s 8-digit [SERIAL NUMBER].
cEnterthe3-digit[SECTION] number you want to program.
3. Program required functions in section [001] (table 2), section [002]
(table 3) and section [003] (table 4) below.
Table 2: Section [001]
Table 3: Section [002]
Table 4: Section [003]
Figure 1 – Removing the Front Cover Figure 2 – Main Unit
Terminal Connector Recommended Wiring Assignment
Bus Label Wire Color
1 12V+ Red
2Minus(-) Black
3 Data Green
4Clock Yellow
Bit Function Status/Description
[1] LED Display Alarm ON:Enabled (default) OFF: Disabled
[3] LED Display Trouble ON:Enabled (default) OFF: Disabled
[4] LED Display Anti- Mask ON:Enabled (default) OFF: Disabled
[5] Anti- Mask ON:Enabled (default) OFF: Disabled
Bit Function Status/Description
[1] Unit Tamper ON: Enabled (default), OFF: Disabled
[2] Wall Tamper ON: Enabled (default), OFF: Disabled
[3] PET Immunity ON: Enabled (default) (PET Mode)
OFF: Disabled (SHARP Mode)
PIR Sensitivity Level