Tremblant COMO User manual

Outdoor Fireplace
COMO
INSTRUCTION MANUAL
Please read and retain this manual
Product code T5443
Made in China
Only supported in Australia
WARNING:
For Outdoor Use Only

www.tremblant.com.au
Page 2 of 18
COMO –USER GUIDE VERSION 1.0
Table of Contents
PRECAUTION .........................................................................................................................3
WARNING .............................................................................................................................5
AREA HEATER STAND AND LOCATION ....................................................................................6
PRODUCT SPECIFICATION ......................................................................................................8
GETTING STARTED .................................................................................................................9
PACKAGE CONTENTS AND ACCESSORIES ................................................................................9
ASSEMBLY PROCEDURE ....................................................................................................... 10
GAS REQUIREMENTS ...........................................................................................................13
LIGHTING INSTRUCTIONS..................................................................................................... 14
AFTER USE AND STORAGE.................................................................................................... 15
CLEANING AND MAINTENANCE ........................................................................................... 15
TROUBLESHOOTING CHECKLIST ........................................................................................... 17
WARRANTY ......................................................................................................................... 18
MAINTENANCE....................................................................................................................18

www.tremblant.com.au
Page 3 of 18
COMO –USER GUIDE VERSION 1.0
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
•Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any
other appliance.
•A LPG cylinder not connected for use shall not be stored in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
•Shut off gas to the appliance.
•Extinguish any open flame.
•If odour continues, keep away from the appliance and immediately call your gas supplier or fire
department.
PRECAUTION
PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE
OPERATION AND INSTALLATION. REPAIRS SHOULD ONLY BE DONE BY THE
MANUFACTURER OR QUALIFIED TECHNICIAN.
•Do not use this appliance indoors, as it may cause personal injury or property damage. THIS
APPLIANCE MUST ONLY BE USED OUTDOORS.
•Do not install or use this appliance indoors.
•Do not connect the heater to any gas supply until fully assembled.
•Do not place articles on or against this appliance.
•Do not spray aerosols near this appliance while it is in operation.
•This outdoor area heater is not intended to be installed on recreational vehicles and/or boats.
•Appliance should be located on a solid surface.
•A qualified technician should carry out maintenance.
•Improper installation, adjustment and alteration can cause personal injury or property damage.
•Do not attempt to alter the area heater in any manner. Any modifications may be dangerous and are
not permitted.
•Do not store or use petroleum or other flammable vapours or liquids in or near the area heater.
•The whole gas system, hose, regulator, pilot, or burner should be inspected for leaks or damage
before use and at least annually by a qualified technician.
•All leak tests should be done with a soap solution. Never use an open flame to check for leaks.
•Do not use the area heater until all connections have been leak tested.
•Turn off the gas valve if the smell of gas is detected, and immediately shut off any gas supply.

www.tremblant.com.au
Page 4 of 18
COMO –USER GUIDE VERSION 1.0
•Do not move the area heater while it is in operation.
•Do not move the area heater until the temperature has thoroughly cooled.
•The control compartment, burner and circulation air passageways of the area heater must be kept
clean.
•Frequent cleaning may be required as necessary. It is recommended to use a cover while not in use.
•Do not modify this appliance.
•All gas cylinders should be turned off when the area heater is not in use.
•Check the area heater immediately if any of the following occurs:
The area heater does not reach temperature.
The burner makes popping noises during use (a slight noise is normal when the burner is
extinguished).
The smell of gas combined with the extreme yellow tipping of the burner flames.
The burner does not ignite or continue to go out.
•The gas regulator and hose assembly must be located in the cylinder cabinet where the gas LPG
cylinder is installed.
•Any guard or other protective device removed for servicing the area heater must be replaced before
further use.
•Adults and children should avoid high-temperature surfaces to avoid personal injury or property
damage. WARNING: Accessible parts may be scorching.
•Children should be carefully supervised at all times when they are in the heater area.
•Clothing or other flammable materials should not be hung on the area heater or placed on or near the
device.
•Do not use the area heater for any form of cooking.
•Do not throw anything into the heater.
•Do not leave the area heater unattended while in operation.
•Do not use the area heater in excessively windy conditions.
•Do not use the area heater in stormy conditions, which could damage components.
•Ensure the gas supply is isolated and shut off when not used and the gas control valve is OFF.
•Follow all instructions regarding the use of LPG bottles. Please get in touch with your local gas supplier
for further advice if needed.
•WARNING: Flames from the area heater are almost invisible in direct sunlight.

www.tremblant.com.au
Page 5 of 18
COMO –USER GUIDE VERSION 1.0
WARNING
1.The area heater is intended for outdoor spaces. The installation must conform with local codes or,
in the absence of local codes, with the Australian Standard AS/NZS 5601.
2.Refer to the data label for the confirmation of gas type to be used.
3.The gas manifold supply pressure must be regulated at 2.75 kPa utilising at AGA approved regulator
(supplied with heater).
4.Never connect a non-approved gas cylinder.
5.Only use up to a 9kg LPG gas cylinder.
6.The minimum distance from non-protected combustible materials shall be 2m.
7.Change the gas cylinder in an amply ventilated area, away from any ignition source (candle,
cigarettes, other flame producing appliances).
8.Check that the regulator seal is correctly fitted and able to fulfil its function.
9.Do not obstruct the ventilation holes of the cylinder housing.
10.Close the gas supply at the valve of the gas cylinder or the regulator after use.
11.In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut
off and the appliance shall be investigated and rectified before it is used again.
12.Check the tubing or the flexible hose (periodically and each time the cylinder is changed). If it
shows signs of cracking, splitting or other deterioration it shall be exchanged for a new hose and
regulator of the same length and must be AGA certified. Read the instructions before installation and
use.
13.This appliance must be installed, and the gas cylinder stored in accordance with the Australian
regulations.
14.Do not obstruct the ventilation holes of the cylinder housing.
15.Do not move the appliance when in operation.
16.Shut off the valve at the gas cylinder or the regulator before moving the appliance.
17.The Gas hose and connections must be changed within the prescribed intervals.
18.Use only the type of gas and the type of cylinder specified by the manufacturer.
19.In case of violent wind particular attention must be taken against tilting of the appliance.
20.Keep the instructions for future reference.
21.Do not connect the gas cylinder directly to the appliance without a regulator.
22.The tubing or the flexible hose must be changed within the prescribed intervals.
23.Use only the type of gas and the type of cylinder specified in these instructions.
24.The injector is assembled by manufacturer only.

www.tremblant.com.au
Page 6 of 18
COMO –USER GUIDE VERSION 1.0
AREA HEATER STAND AND LOCATION
The area heater is for outdoor use only. Always ensure that adequate ventilation is provided. Always
maintain proper clearance to combustible materials, i.e., top 1 meters and sides 1-meter minimum.
The area heater must be placed on the firm-level ground.
Never operate the area heater in an explosive
atmosphere, like in an area where petrol or other
flammable liquids or vapours are stored.
The area heater is fitted with a ‘Overturn Shut Off
Device.’ If the area heater is tilted, does not stand
vertically, or is to fall over, it will automatically shut off
the gas supply, and the appliance will shut down.
Never operate the area heater in an explosive
atmosphere where petroleum or other flammable liquids
and gases are stored.
*Combustible materials are considered to be wood,
compressed paper, plant fibres, plastic or other materials
that are capable of being ignited and burned.
*Clothing or other flammable materials should not be
hung from the heater or placed on or near the heater.
The area above the burner may be extremely hot. Direct
contact with these metal surfaces should be avoided in
order to prevent burns or clothing ignition.
DIAGRAMMATICAL REPRESENTATION OF OUTDOOR AREAS
SAFE APPLIANCE LOCATIONS
Only use the appliance in an above-ground open-air area with natural ventilation, without stagnant
areas, where gas leakage and combustion products are rapidly dispersed by wind and natural
convection. Any enclosure in which the area heater is used shall comply with one of the following:
•An enclosure with walls on all sides, but at least one permanent opening at the ground level and
no overhead cover.
•A partial enclosure that includes an overhead cover and no more than two walls.
•A partial enclosure that includes overhead and more than two walls, the following shall apply:
oAt least 25% of the total wall area is entirely open, and
oAt least 30% of the remaining wall area is open and unrestricted.
In the case of balconies, at least 20% of the total wall area shall remain open and unrestricted.
1000mm
1000mm
1000mm

www.tremblant.com.au
Page 7 of 18
COMO –USER GUIDE VERSION 1.0
DIAGRAMMATICAL REPRESENTATION OF OUTDOOR AREAS
The following figures are diagrammatical representations of outdoor areas as described above.
Rectangular areas have been used in these figures –the same principles apply to any other shared
areas.

www.tremblant.com.au
Page 8 of 18
COMO –USER GUIDE VERSION 1.0
PRODUCT SPECIFICATION
The gas area heater is designed to work with the following gas types.
Assembled dimensions
D430mm, W430mm, H1335
Certificate Number
AGA 9126-G
Standard
AS/NZS 5263.0 and 5263.1.4
Heat Input
23MJ/h
Injector Size
LPG-1.3mm
Test point pressure
LPG-275 Kpa
Net Weight
38KG
Gas Bottle/Size
350*600(H)
LPG Gas Hose W/ Regulator
Included
Glass Stones
Included
Gas Type Supported
LPG Gas
Safety Tilt Device
Yes
ODS (Oxygen Detection Safety System)
Yes
Surface Treatment
Powder Coating
Colour
Black
Adjustable Flame
Yes
Thickness of Glass
5mm
Glass Temperature
Tempered. 180°C
Bottom Feet
Screw in legs

www.tremblant.com.au
Page 9 of 18
COMO –USER GUIDE VERSION 1.0
GETTING STARTED
Please read instructions thoroughly before using the appliance.
The gas area heater will arrive in one box containing the appliance with an installed burner, bottom
legs, glass panels, glass brackets, glass stones, hex screwdriver, doorhandle with screws and LCC27 gas
hose and regulator.
Remove the appliance from the packaging. Carefully place it on the floor, keeping it upright for easy
assembly.
Extreme care should be taken when handling the heater to ensure the gas pipes, thermocouple lead,
gas valve, or burner are not damaged or loosened.
Please note: ALL heaters have been burning and leak tested before leaving the factory. Although each
unit is cleaned, there may be an odd scorch mark around the pilot and main burner gas jets.
IMPORTANT: Remove all packing material (including any protective coatings)
and discard prior to use.
HANDLING OF THE UNIT REQUIRES TWO OR MOR PEOPLE. EXERCISE EXTREME
CARE DURING ASSEMBLY AND ISNTALLATION.
PACKAGE CONTENTS AND ACCESSORIES
(ACCESSORIES SOLD SEPARATELY)
*Tools required-adjustable spanner and phillips head screwdriver.
Appliance Fireplace
LPG Gas Regulator and
Hose
Door Handle
Glass Panels with
Bracket Attachments
and Screws
Screw in Legs
Hex Screwdriver
Glass stones. Lava rocks
(sold separately)
Cover
(sold separately)

www.tremblant.com.au
Page 10 of 18
COMO –USER GUIDE VERSION 1.0
ASSEMBLY PROCEDURE
Remove the heater body and all the parts from carton, then follow the procedures below.
STEP 1 - ATTACH CABINET HANDLE
Attach cabinet screw handle in the hole in the rear panel.
STEP 2 –ATTACH LEGS
With at least two people, carefully tilt the appliance onto its side to attach the legs. Using an adjustable
spanner, attach and tighten.
STEP 3 –ADDING GLASS STONES
Note: for this step, you may need a small step ladder or platform to give extra height, as the fuel beds
must be installed from the top of the appliance.
GLASS STONES FOR STAR OR PAN BURNER
This should be done outside. Cover the burner with either glass stones or optional lava rocks. DO NOT
tip the glass or lava rock bag onto the burner, as the bags usually contain some fine dust that could clog
the burner jets. It is better to empty the bags into a suitable container and place the glass or rock by
hand around the burner. Ensure the area around the pilot light is clear to allow air to reach.

www.tremblant.com.au
Page 11 of 18
COMO –USER GUIDE VERSION 1.0
POSITIONING OF GLASS STONES OR LAVA ROCKS ON THE BURNER –KEEP PILOT AREA CLEAR
STEP 4 –INSTALLING SURROUNDING SAFETY GLASS
Using a HEX screwdriver, fix the surrounding safety glass together with the supplied glass brackets and
screws around the sides of the burner. Then using a HEX screwdriver fix the top safety glass to the top
of appliance with the supplied glass brackets and screws. This will need to be done with two people.
IMPORTANT. Do not over tighten screws.
STEP 5 –INSTALL LPG GAS BOTTLE AND CONNECT
Follow the instructions.
Feed the gas hose through the separation plate grove, then attach the gas hose to the control section
on the right-hand side using a spanner. Connect the gas hose using the LCC27 connection to the gas
bottle and hand tighten.

www.tremblant.com.au
Page 12 of 18
COMO –USER GUIDE VERSION 1.0
STEP 4 –GAS CONNECTION
Attach the gas hose to the control section on the right-hand side using a spanner. The swivel nuts have
right-handed threads.
GAS BOTTLE AND REGULATOR AND HOSE CONNECTION
The gas hose and regulator are AGA approved and support a different fitting called an LCC27.
From April 2021, the LPG gas bottles with the new LCC27 fittings will be used and have improved safety
features, including an easy-to-use right-hand threaded external ACME connection and a back check
valve that must be engaged by having a positive connection to the appliance hose before the gas can
flow. The LCC27 appliance connection also has a thermal cut-out.
The gas hose should be checked regularly to ensure it is in good condition and it is recommended to be
replaced per standard practices.
Tighten LPG bottle connection by hand.
Check all connections for gas leaks.

www.tremblant.com.au
Page 13 of 18
COMO –USER GUIDE VERSION 1.0
WARNING
It’s extremely important that you DO NOT route the gas hose under or directly under the burner. Do
not allow the hose to touch any part of the burner or heater. The hose should be located so that it is
not subjected to undue strain or placed where it could be damaged.
The hose assembly should be located out of pathways where people may trip over it. The hose must
be protected from contact with hot or sharp surfaces both during use and while in storage. The hose
assembly should be visually inspected prior to each use of the heater. If excessive abrasion or wear is
evident, or the hose is cut, it must be replaced prior to operating the heater. The replacement hose
assembly may be obtained from the distributor.
DO NOT use any pressure regulator or hose assembly other than those supplied with the appliance.
Replacement pressure regulator and hose assembly must be those specified. Replacement parts may
be obtained from the distributor.
Clothing or other flammable materials should not be hung from the heater or placed on or near the
heater. The area above the burner may be extremely hot. Direct contact with these metal surfaces
should be avoided in order to prevent burns or clothing ignition.
The hose assembly is to be replaced prior to the appliance being used if there is evidence of damage.
(Such as excessive abrasion or wear). Any replacement hose assembly is to be specified by the
manufacturer.
GAS REQUIREMENTS
•Refer to the gas type label inside the door to confirm the gas type to be used with your appliance.
•Always use the correct and approved AGA pressure regulator and hose assembly suitable for the gas
cylinder. Contact your local gas supplier for further advice if needed. Use Only an approved 9kg gas
cylinder.
•Dented, rusted or damaged gas cylinders may be hazardous and should be checked by your gas
supplier. Never use a cylinder with a damaged valve connection.
•Never connect an unregulated gas cylinder to the heater.
•The area heater must be checked with a full cylinder.
•Make sure the safety control valve is in the ‘OFF’ position.
•Turn the gas supply from the cylinder ON.
•In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on
and recheck.
•Never do a leak test while smoking.

www.tremblant.com.au
Page 14 of 18
COMO –USER GUIDE VERSION 1.0
LEAKAGE TEST
Gas connections on the area heater are leak tested at the factory before shipment. A complete leakage
test should be performed at the installation due to possible mishandling in load or excessive pressure
being applied to the heater.
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied
with a spray bottle, brush, or rag. Ensure all gas control values are turned off. Apply a brush or spray
bottle apply the solution to the gas lines and joins. Soap bubbles will appear in case of a leak. Do not use
the area heater until the leak has been fixed.
LIGHTING INSTRUCTIONS
•Open the cabinet door and place the gas cylinder into the cabinet.
•It would help if you were hinged on the door chain when the gas bottle
is placed in the cabinet.
•Turn the control knob clockwise to the “OFF” position.
•Connect the gas hose regulator to the gas bottle. Feed the gas hose in
the groove in the separation plate.
•Turn the gas supply “ON” at the cylinder. Check with soapy water for gas leakage between the
cylinder and the regulator.
•Push down the control knob and keep pressing while turning anti-clockwise slowly to the “Ignition”
position (a click will be heard); this will light the pilot.
•If the click is not heard, repeat this process. Note that air will be in the gas hose or the rest of the
system when first connecting the area heater to the gas cylinder. Press the control valve knob for
about one minute to purge the air and allow gas into the system.
•Once the pilot burner is lit, keep the control knob pressed for five seconds, then release it.

www.tremblant.com.au
Page 15 of 18
COMO –USER GUIDE VERSION 1.0
•If the burner does not stay alight, repeat the steps above.
•Adjust the heat setting by turning the control knob to the ‘High’ or ‘Low’ position.
•To shut down the area heater, turn the gas cylinder valve or regulator switch to the ‘OFF’ position
and then turn the control valve knob on the appliance clockwise to the ‘OFF’ position.
WARNING
If the burner fails to ignite, turn the control valve knob ‘OFF’ (clockwise) and turn the gas cylinder
valve ‘OFF.’ Wait for five minutes before attempting to re-light with the ignition sequence.
AFTER USE AND STORAGE
•Turn the control knob on the appliance clockwise to the ‘OFF’ position.
•Turn the gas supply off at the cylinder.
•Do not leave the area until the flames have fully extinguished.
•Children must not be left unattended straight after use as the appliance will still be hot for some
time.
•Check the gas valve for tightness and damage. If damage is suspected, this must be changed by a
qualified technician.
•Once the area heater has cooled down, it is safe to cover for protection.
•Storage of an appliance indoors with a cylinder attached is only permitted if the size of the cylinder
complies with AS/NZS 1596: otherwise, cylinders must be stored outdoors in a well-ventilated area
out of the reach of children.
•There is no limitation on the storage of appliances indoors provided that the cylinder is removed
from the appliance.
CLEANING AND MAINTENANCE
•Ensure all cleaning is done while the area heater is turned off and fully cooled down.
•Wipe surfaces with a soft, damp cloth.
•Do not use any corrosive or combustible cleaning solutions.
•Keep the outdoor fire covered when not in use to stop rain from blocking the burner jets.
•Ensure the burner is clean and clear of combustible materials and dirt.
•Soot can build up on the glass beads or lava rocks. This could block burner jets, so remove the fuel
bed and wipe with a damp cloth to clean the soot.
•Soot can build up on the surrounding safety glass. Carefully remove the mirror from the glass
bracket with a relative Phillips screwdriver, wipe the soot with a soft, damp cloth, then carefully
replace it. Two people may be required to disassemble and reassemble the surrounding safety glass.
•Ensure the condition of the gas hose is suitable and shows no signs of cracking or general wear and
tear.

www.tremblant.com.au
Page 16 of 18
COMO –USER GUIDE VERSION 1.0
•It is advised to get the appliance checked and serviced annually by a qualified technician.
•If the burner jets get blocked by soot or other dirt, remove the fuel bed and use a pin or paper clip
to clear the blockages. Ensure the burner is switched off and the gas is disconnected.
•Follow the above maintenance steps regularly.
•More frequent cleaning may be required as necessary.
•It is imperative that the control compartment burner and circulating air passageways of this
appliance be kept clean.
IMPORTANT SAFETY RULES
•Never use the heater while it is raining, the glass will break.
•The glass will be extremely hot when operating, never try to touch it and keep children away from
the heater.
•Always ensure the heater is seated firmly, the glass may break if the heater falls.
•Never use the heater if the glass has any crack or damage.
THE GUARD IS FITTED TO THIS APPLIANCE TO REDUCE THE RISK OF FIRE OR
INJURY FROM BURNS AND NO PART OF IT SHOULD BE REMOVED.
ANY GUARD OR OTHER PROTECTIVE DEVICE REMOVED FOR SERVICING THE
APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage.
Any modifications or adjustments made to product without prior authority from the manufacturer
will void any warranty claims.
Read the installation, operating and maintenance instructions thoroughly before installing or
servicing this equipment.

www.tremblant.com.au
Page 17 of 18
COMO –USER GUIDE VERSION 1.0
TROUBLESHOOTING CHECKLIST
Pilot will not light or stay on
•Ensure the gas supply is turned on and the cylinder is not empty.
•Press the ignition button several times. Keep the main gas lever pressed for at least 10 seconds.
•If the ignition button stays stuck, lubricate with WD40 while the area heater is not lit.
•Keep trying, as air can get trapped in pipes and can take some time to purge all the air out of the
system.
•Check that glass or lava rocks or other debris are not covering the pilot.
•Check to see if any connections are loose and tighten them if required.
•Check to see if there is a leak in the gas hose. Replace if required.
•Try lighting the pilot with a match or lighter if the spark electrode is wet or damaged.
•Ensure the appliance is on level ground and completely vertical, as the ‘Overturn Shut Off Device’
may have been triggered.
Burner will not light
When the pilot is lit, there should be no reason the main burner would not light.
•If the pilot is lit, but the burner does not light, check if too much glass or lava rock is around the
pilot assembly. This could block the pilot light from igniting the main burner.
•If the pilot is lit, but the burner does not shine, there could be damage to the control valve. This
would need replacing by a qualified technician.
•If the pilot is not lit, the flame failure device has cut off the gas supply. Wait 3 minutes, then try
relighting the pilot.
•Ensure the appliance is on level ground and completely vertical, as the ‘Overturn Shut Off Device’
may have been triggered.
Main Burner suddenly goes out
•The main gas supply would automatically cut off if the pilot is extinguished for any reason (sudden
gust of wind or it started raining).
•Turn the control lever to the ‘OFF’ position and leave for three minutes before relighting the pilot.
•Once the pilot is lit, the main burner will work.
•The gas cylinder may be empty. If so, replace the cylinder with a full one.
•Ensure the appliance is on level ground, not fallen over, and utterly vertical as the ‘Overturn Shut
Off Device’ may have been engaged. The gas supply will be shut off, and the part may need to be
replaced.

www.tremblant.com.au
Page 18 of 18
COMO –USER GUIDE VERSION 1.0
WARRANTY
Tremblant area heaters come with a one-year warranty from the date of purchase. If there appears to
be material or manufacturing errors, the defects resulting from these errors shall be repaired or
replaced by Tremblant. If a defect is not fixed, Tremblant can offer reasonable compensation. The
decision to replace, repair, or otherwise provide compensation for a defect is taken at the sole
discretion of Tremblant. All warranty claims are expressly subject to the condition that the maintenance
recommendations from Tremblant have been followed correctly and that the item is used exclusively
under normal conditions. In addition, the requirement that the product is solely used in the land of
destination listed in this operation and installation manual and the product sticker also applies.
Warranty claims for defects/damages arising from inappropriate use, incorrect or injudicious use, or
normal wear and tear are excluded from this coverage. A warranty claim can only be made upon
presenting the original invoice, which must be stored carefully. Only the original buyer may submit a
warranty claim. The claim may only be forwarded to the dealer or directly from the product originally
purchased.
Tremblant must first assess a warranty claim. The warranty does not automatically include
reimbursement of the transport costs of defective products to the Tremblant location or the concerned
dealer. The same applies to return shipments of replaced or repaired products. The repair itself is
performed free of charge within the warranty period.
MAINTENANCE
Good maintenance of Tremblant area heaters will significantly benefit the quality and lifetime of the
product. We suggest using the weatherproof protective cover (sold separately) for the most optimal
protection. It will keep the area heater clean and ready to use. Be aware that the fire must cool down
entirely before placing the cover over the Tremblant area heater. If you use the Tremblant area heater
sparingly over a more extended period, we suggest storing the fire inside or in a weatherproof dry
space.
Despite the high-quality finish and the use of high-quality materials, the climate still affects the quality
of the Tremblant area heaters and accessories. You can keep the Tremblant area heater in top condition
by protecting it as much as possible against sun weathering. We suggest placing the Tremblant area
heater in an area free of direct sunlight (at least when it is not being used) to prevent discoloration. This
also applies to prevent discolouration of the protective cover. You can clean the Tremblant area heater
with a damp cloth and a regular cleaner.
The use of abrasive and aggressive cleaners must not be used. Also, avoid the use of microfiber cloths.
These reduce their cleaning capacity to the abrasive effect of the microfibers. To clean the inside of the
Tremblant area heater, you need to disassemble the roof first. Afterward, you can lift the glass panes,
providing all the necessary space to clean the area heater's interior. It is also recommended to clean any
dust near the injectors by removing lava rocks or glass stones. Only use AGA-approved hoses or
accessories.
02 9158 3232
PO Box 2413
DANGAR NSW 2303
AUSTRALIA
CONNECT OR FOLLOW US
support@tremblant.com.au
www.tremblant.com.au
Table of contents
Popular Outdoor Fireplace manuals by other brands

höfats
höfats BOWL 57 Instructions for use

Firegear
Firegear FPB-G34DBSMT-N Installation and operating instructions

CAMBRIDGE
CAMBRIDGE Pre-Packaged Olde English Paver Fireplace Kit Deluxe... instruction manual

Perel
Perel BB651 user manual

Empire
Empire ONR-30-2 Installation instructions and owner's manual

CAMBRIDGE
CAMBRIDGE Pre-Cut manual

Keystone Hardscapes
Keystone Hardscapes ASHLAND quick start guide

Firegear
Firegear FPB-19 AFEI/N operating instructions

pleasant hearth
pleasant hearth OFW106R quick start guide

Hiland
Hiland Premium Series Assembly instructions

Endless Summer
Endless Summer Chesapeake owner's manual

Hearth and Home Technologies
Hearth and Home Technologies Outdoor Lifestyles ODVILLA-36T owner's manual