INTRODUCTION:
Thank you for having chosen this professional moving head.
You will see you have acquired a powerful and versatile device.
Unpack the device. Inside the box you should find: the fixture device, a power cable, an XLR
connection cable, a safety cable and this manual. Please check carefully that there is no damage
caused by transportation. Should there be any, consult your dealer and don’t install this device.
Features:
·Lamp: Philips MSR 575 GOLD SA/2 DE
·Control channel: 16 channels
·Pan movement: 540°/ 630° optional (16bit)
·Tilt movement: 265° (16 bit)
·CMY color mixing
·Color wheel : 8 interchangeable dichroic filters plus open
·Effect wheel: beam shaper
·Shutter: variable from 1-13 flashes per second or random strobe
·Dimmer: 0~100% full range dimming
·Zoom: 13°~ 50° linear zoom
·Friendly blue LCD display
·Electronic ballast version: with enhanced light output, flick-free operation, extended life, higher
power factor and less power consumption, less weight.
·RDMX: remote DMX addressing, lamp on/off, Sound control switch by controller.

- 2- XM155 V1.0 NR
OVERVIEW
SAFETY INSTRUCTIONS
This device has left the factory in perfect condition. In order to maintain this condition and to ensure
a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this user manual.
(1) Head
(2) Lens
(3) Yoke
(4) Ventilation fan
(5) Control Board
(6) Base
(7) Carrying handle
(8) LCD-Display
(9) Mode/Esc-button
(10)Up-button
(11)Down-button
(12)Enter-button
(13)Microphone
(14)Update-socket
(15)Ventilation grille
(16)Housing screw
(17)Lamp system
(18)3-PIN DMX output socket
(19)3-PIN DMX input socket
(20)Fuse
(21)5-PIN DMX output socket
(22)5-PIN DMX input socket
(23)Power supply

- 3- XM155 V1.0 NR
If the device has been exposed to temperature changes due to environmental changes, do not switch
it on immediately. The arising condensation could damage the device. Leave the device switched off
until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that the device be earthed.
The electric connection must carry out by qualified person.
The device shall only be used with rate voltage and frequency.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case,
replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle
the power cord by the plug. Never pull out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal process and does not
necessarily mean that the device is defective, it should decrease gradually.
Please be aware that damages caused by manual modifications to the device are not subject to
warranty. Keep away from children and non-professionals.
GENERAL GUIDELINES
This device is a lighting effect for professional use on stages, in discotheques, theatres, etc.
This fixture is only allowed to be operated with the max alternating current which stated in the
technical specifications in the last page of this manual, the device was designed for indoor use only.
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure
that the device will serve you for a long time without defects. Do not shake the device.
Avoid brute force when installing or operating the device.
The device shall only be used complete with its protective shield.
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. The minimum distance between light-output from the projector and the illuminated
surface must be more than 0.5 meter.

- 4- XM155 V1.0 NR
Always fix the fixture with an appropriate safety cable if you use the quick lock cam in hanging up
the fixture, please make sure the 4 quick lock fasteners turned in the quick lock holes correctly.
Operate the device only after having familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional
operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden.
If this device will be operated in any way different to the one described in this manual, the product
may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to
short-circuit, burns, electric shock, lamp explosion, crash, etc.
INSTALLATION INSTRUCTIONS
a) Installing or replacing the lamp
Before replacing the lamp let the lamp cool down, because during operation, the lamp can reach very
high temperature.
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a
cloth to handle the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than which the device
was designed for.
For the installation, you need one Philips MSR GOLD 575 SA/2 DE
Procedure:

- 5- XM155 V1.0 NR
1) Unscrew the 4 screws A, B,C and D on the bottom of the housing, holding the plate where the
lamp is underneath.
2) Gently pull the socket holder using the knob in the middle.
3) Carefully insert the lamp into the socket. Please remember there is only one way to insert the lamp.
Gently slide the lamp and its lamp holder back into place and fasten the 4 screws.
4) On the access plate there are 3 small screws marked 1, 2 and 3.which are used to adjust the lamp
holder in the lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get
the maximum light output as shown below.
Please remember the lamp is not a hot-restrike type, you must wait for approximately 15 minutes
after having turned off the lamp before you can turn it back on again.
b) Mounting the device
The installation of the effect has to be built and constructed in a way that it can hold 10 times the
weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate
safety cable.
Never stand directly below the device when mounting, removing or servicing the fixture.
The operator has to make sure the safety relating and machine technical installations are approved by
an expert before taking the device into operation for the first time.
These installations have to be approved by a skilled person once a year.
Cautions:

- 6- XM155 V1.0 NR
The effect should be installed outside areas where persons may reach it, walk by or be seated.
Overhead mounting requires extensive experience, including amongst others calculating working
load limits, installation material being used, and periodic safety inspection of all installation material
and the device. If you lack these qualifications, do not attempt the installation yourself. Improper
installation can result in bodily injury.
Before mounting make sure that the installation area can hold a minimum point load of 10 times the
device’s weight.
Connect the fixture to the mains with the power plug.
Installation method via clamp
Please refer to the picture below:
Screw one clamp each via a M12 screw and nut onto the Omega holders.
Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of the
device. Tighten the quick-lock fasteners fully clockwise. Install the second Omega holder.
Pull the safety-rope through the holes on the bottom of the base and over the trussing system or a
safe fixation spot. Insert the end in the carabine and tighten the safety screw.

- 7- XM155 V1.0 NR
DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other
side to the male 3-pin XLR input of the moving head. You can chain multiple
Moving head together through serial linking. The cable needed should be two core, screened cable with
XLR input and output connectors. Please refer to the diagram below.
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically noisy
environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in
preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply
an XLR plug with a 120 Ωresistor connected between pins 2 and 3,which is then plugged into the
output XLR socket of the last fixture in the chain. Please see illustrations below.
Starting address 33 Starting address 17 Starting address 1
Projector DMX starting address selection
All fixtures should be given a DMX starting address when using a DMX signal, so that the correct
fixture responds to the correct control signals. This digital starting address is the channel number
from which the fixture starts to “listen” to the digital control information sent out from the DMX
controller. The allocation of this starting address is achieved by setting the correct number on the

- 8- XM155 V1.0 NR
display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures, or make different address
for each fixture individually.
If you set the same address, all the units will start to “listen” to the same control signal from the same
channel number. In other words, changing the settings of one channel will affect all the fixtures
simultaneously.
If you set a different address, each unit will start to “listen” to the channel number you have set,
based on the quantity of control channels of the unit. That means changing the settings of one
channel will affect only the selected fixture.
In the case of the moving head, which is 16 channels fixture, you should set the starting address of
the first unit to 1, the second unit to 17(16 + 1), the third unit to 33 (16+ 17), and so on.
Control Board
The Control Board offers several features: you can simply set the starting address, switch on and off the lamp, run
the pre-programmed program or make a reset.
The main menu is accessed by pressing the Mode/esc-button until the display starts flashing. Browse through the
menu by pressing the Up-button or Down-button. Press the Enter-button in order to select the desired menu. You
can change the selection by pressing the Up-button or Down-button. Confirm every selection by pressing the
Enter-button. You can leave every mode by pressing the Mode/esc-button. The functions provided are described in
the following sections.
Default settings shaded
Function Mode
Set DMX Address
Value Display
Set To Slave
Auto Program
Music Control
A001~AXXX
PAN Moving……
Slave1,Slave2,Slave3
Master / Alone
Master / Alone
DMX address setting
DMX value display
Slave setting
Auto program
Music control
Time Information
Current Time
Total Run Time
Total Lamp Time
Lamp Off Time
Clear Lamp Time
XXXX(Hours)
XXXX(Hours)
XXXX(Hours)
XXXX(Minute)
ON/OFF
Power on running time
Fixture running time
Lamp running time
Lamp off time
Clear lamp time
Temperature Info
Base Temperature
Head Temperature
XX ℃/℉
XXX℃/℉
Temperature on the display
board of the base
Temperature in the head
Information
Software Version
Ver1.0
Software version of each IC
Lamp Control
Lamp On or Off
Automatic La-On
Lamp On Via DMX
Lamp Off Via DMX
Lamp Off No DMX
Lamp On at Temp.
Lamp Off at Temp.
ON/OFF
ON/OFF
ON/OFF
ON/OFF
OFF, 0FF~19M
20~79℃,45℃/68~174℉ 113℉
80~139℃,130℃ /176~282℉, 266℉
Lamp on/off
Lamp on/off when Power
on
Lamp on via DMX
Lamp off via DMX
Lamp off if no DMX
Lamp restart at temp.
Lamp off at temp.

- 9- XM155 V1.0 NR
Status Settings
Address via DMX
No DMX Status
Pan Reverse
Tilt Reverse
Fine Resolution
Pan Degree
Feedback
Movement Speed
Mic Sensitivity
ON/OFF
Close/Hold/Auto/Music
ON/OFF
ON/OFF
ON/OFF
630/540
ON/OFF
Speed 1~ 4
0~99%
Add. via DMX
Auto run if no DMX
Pan Reverse movement
Tilt Reverse movement
Fine resolution switch
Pan Degree Select
Movement Feedback switch
Movement Mode Select
Sensitivity of Mic.
Service Setting
Service Password
Fan Voltage
Password=XXX
High/Low
Service Code“=050”
Fan Voltage Select
Fans Control
Auto Fans Speed
High Fans Speed
Low Fans Speed
Fans Speed Mode Select
Display Setting
Shutoff Time
Display shutoff time
Temperature C/F
Celsius
Fahrenheit
Temperature switch
between ℃/℉
Initial Effect
PAN……
PAN =XXX
Initial effect position
Personality
Reset Default
ON/OFF
Restore factory sett.
Reset Function
Reset All
Reset Pan&Tilt
Reset Colors
Reset Shutter
Reset Others
Reset all motors
Reset Pan/Tilt
Reset color wheel
Reset shutter and/or dimmer
Reset other motors
Test Channel
PAN ……
Test function
Manual Control
PAN
:
PAN =XXX
:
Fine adjustment of the lamp
Effect Adjust
Calibrate Values
--Password--
Color wheel
:
Password=XXX
Color wheel=XXX
:
Calbrate and adjust the
effects to standard/right
position Password“050”
User Mode
XXXXXX(Band)
User Mode A
User Mode B
User Mode C
User’s mode to change
channel numbers
Users Mode Set
Edit User Mode
PAN
:
PAN = CH01
:
Preset User modes
Select Programs
Auto Pro Part 1
Auto Pro Part 2
Auto Pro Part 3
Program 1 ~ 10 Program 1
Program 1 ~ 10 Program 2
Program 1 ~ 10 Program 3
Select programs to be run
Edit Program
Program 1
:
Program 10
Program Test
Step 01=SCxxx
Step 64=SCxxx
(“STEP XX”)
Testing program
Program in loop
Save and exit
Edit Program
Edit Scenes
Edit Scene 001
~ Edit Scene 250
Pan,Tilt,……
--Secne Time--
Pan=xxx……
TIME=xx.xs
Save and automatically
return

- 10 - XM155 V1.0 NR
Input By Outside
manual scenes edit
Rec. Controller
XX~XX
Automat.scenes rec
Function Mode
DMX address setting
With this function, you can adjust the desired DMX-address via the Control Board.
• Select “Set DMX address” via the encoder.
• Press the encoder, adjust the DMX address by turning the encoder.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order return to the main menu.
Display the DMX 512 value of each channel
With this function you can display the DMX 512 value of each channel. The display automatically shows the channel
with a value changing.
Slave setting
With this function, you can define the device as slave.
Auto Program
With this function, you can run the internal program. You can select the desired program under “Select program”.
You can set the number of steps under “Edit program”. You can edit the individual scenes under “Edit scenes”.
With this function, you can run the individual scenes either automatically, i.e. with the adjusted Step-Time.
Music control
With this function, you can run the internal program sound-controlled.
Information
Time information
Power on time
With this function, you can display the temporary running time of the device from the last power on. The display
shows “XXXX”, “XXXX” stands for the number of hours. The counter is resetted after turning the device off.
Total run time
With this function, you can display the running time of the device. The display shows “XXXX”, “XXXX” stands for
the number of hours.
Total lamp time
With this function, you can display the running time of the lamp. The display shows “XXXX”, “XXXX” stands for the
number of hours.
Lamp off time
With this function, you can display the temporary running time of the lamp from the last lamp on. The display
Shows “XXXX”, “XXXX” stands for the number of hours. The counter is resetted after turning the lamp off.
Clear lamp time
With this function you can clear the running time of the lamp. Please clear the lamp time every time you replace the
lamp.
• Select “Clear lamp time” by turning the encoder.
• Press the encoder, the display shows “ON” or “OFF”.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
Temp. Info.

- 11 - XM155 V1.0 NR
Base Temp
With this function you can display the temperature in the projector base (near LCD-display) in Celsius.
Head Temp
With this function you can display the temperature on the display board of the base (near CMY-filter) in Celsius.
Software version
With this function, you can display the software version of the device.
• Select “Software version” by turning the encoder.
• Press the encoder, the display shows “V-X.X”, “X.X” stands for the version number, e.g. “V-1.0”, “V-2.6”.
• Turn the encoder in order to read the version of every individual IC.
• Press the Mode/Esc-button in order to return to the main menu.
LAMP CONTROL
When the real temperature around the lamp is higher than the preset value, the lamp will be shut down in 5
minutes automatically.
·When the LCD display shows “Off”, it means the lamp must be turned on again manually;
·When the LCD display shows “Hot”, it means the actual temperature around the lamp is still higher than the
preset value, so even the lamp can not be striked even the menu Lamp is turned to ON, as the lamp switch is
compelled to turned off.
·When the temperature unit after the temperature value come to lowercase letter “c” or “f”, it means menu
Lamp is turned to ON, but the lamp is not full dimming up.
·When the temperature unit after the temperature value come to capital letter “C” or “F”, it menu Lamp is
turned to ON, and the lamp is full intensity.
Lamp on/off
With this function you can switch the lamp on or off via the Control Board.
• Select "Lamp on/off" by turning the encoder.
• Press the encoder, the display shows “ON” or “OFF”.
• Turn the encoder to select “ON” if you wish to strike the lamp or “OFF” in order to switch it off.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
Remark: The menu Lamp On/Off is the software command only, the lamp can be striked successfully only when the
menu Lamp is set to ON and the actual temperature is lower than the limited value.
Lamp on/off when power on
With this function you can select if the lamp will be switched on when switching the power on. Select “ON” by
turning the encoder if you wish to enable this function or “OFF” if you don’t.
Lamp on via external controller
With this function you can select if you can switch the lamp on via an external controller (DMX-channel of internal
programs, value 64-79). Select “ON” by turning the encoder if you wish to enable this function or “OFF” if you
don’t.
Lamp off via external controller
With this function you can select if you can switch the lamp off via an external controller (DMX-channel of internal
programs, value 224-239). Select “ON” by turning the encoder if you wish to enable this function or “OFF” if you
don’t.
Lamp Off if no DMX
With this function you can select to switch off the lamp off automatically if there is no DMX signal). Select “OFF” by
turning the encoder if you wish to switch off the lamp automatically at once, Select “19M” by turning the encoder if
you wish to postpone to 19 minutes switch off the lamp automatically.
Lamp on at temp.
With this function you can set the inside temperature from which the projector will restrike the lamp after automatic

- 12 - XM155 V1.0 NR
lamp shut off.
Lamp off at temp.
With this function you can set the inside temperature at which the projector will automatically switch the lamp off.
Turn the encoder to select the maximum inside temperature between 60° C and 159° C. Inside temperatures below 90°
C are not critical. 90° C and more should lead to the lamp being switched off. Please note that the outside temperature
should not exceed 45° C.
When the temperature around the lamp is higher than the preset value continuously up to 5 minutes, the
lamp will be shut off automatically.
If the lamp be shut off automatically due to over heat, it can not be striked again automatically, it must be
turned on again by manually.
PERSONALITY
Status setting
Address via DMX
With this function, you can adjust the desired DMX-address via an external controller.
• Select “Address via DMX” by turning the encoder.
• Press the encoder, the display shows “ON” or “OFF”.
• Turn the encoder to select “ON” if you wish to enable this function or “OFF” if you don’t.
• Press the encoder to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
• On the controller, set the DMX-value of channel 1 to "7".
• Set the DMX-value of channel 2 to "7"or "8". When set to "7" you can adjust the starting address between 1 and 255.
When set to "8" you can adjust the starting address between 256 and 511.
• Set the DMX-value of channel 3 to the desired starting address. If you want to set the starting address to 57, set
channel 1 to "7", channel 2 to "7" and channel 3 to "57". If you want to set the starting address to 420,set channel 1
to "7", channel 2 to "8" and channel 3 to "164" (256+164=420).
• Wait for approx. 20 seconds and the unit will carry out a reset. After that, the new starting address is set.
No DMX Status
With this function, when the drive is not DMX signal, it runs automatism, close, hold and music, the default is hold.
Pan Reverse
With this function you can reverse the Pan-movement.
Tilt Reverse
With this function you can reverse the Tilt-movement.
Fine resolution
With this function, you can fine resolution switch of pan movement or tilt movement.
Pan Degree
With this function, you can select pan degree for 630 or 540.
Feedback
With this function, you can feedback switch of pan movement or tilt movement.
Movement Speed
With this function, you can select scan mode from 1 to 4.
Mic Sensitivity
With this function, the default is 70%, you can select the desired microphone sensitivity from 0 % to 99 %.
Service setting
Service Password
With this function, you can set the service password.

- 13 - XM155 V1.0 NR
Fan Voltage
With this function, you can select fan voltage for high or low, the default is low
Attention: The model is not recommended when ambient temperature is higher than 15 Celsius degree.
Fans Control
With this function, you can set the speed of the running fans. The selections have Auto、high and low.
Display settings
Shut off time
With this function you can shut off the LCD display after 2 to 59 minutes. Turn the encoder in order to select the
desired shut off time.
Temperature C/F
With this function, Display the temperature for Celsius or Fahrenheit.
Initial effect
With this function, Display initial effect position.
Reset Default
With this function, you can select restore factory set for ON or OFF, the default is OFF.
Reset-functions
With this function you can reset the device via the Control Board. You can select the different reset functions by
turning the encoder.
Effect Adjust
Test function of each channel
With this function you can test each channel on its (correct) function.
Lamp adjustment
With this function, you can adjust the lamp more easily. All effects will be canceled, the shutter opens and the dimmer
intensity will be set to 100 %. With the individual functions, you can focus the light on a flat surface (wall) and erform
the fine lamp adjustment.
Calibrate values
With this function, you can calibrate and adjust the effect wheels to their correct positions. The password of calibrate
values is 050.
Users mode set
In this menu, user can select different channels list by different sequence:
For example, after the user enter this manual, if select Auto Program = CH 22, means in this User’s mode, the
“Dimmer” is in Channel 16.
User mode
With this function, you can create user defined channel orders.
Preset User mode
With this function, you can adjust the rest user defined channel order.

- 14 - XM155 V1.0 NR
Edit program
Select program
With this function, you can select the program for the Program Run.
Edit program
With this function, you can edit the internal programs.
Edit scenes
With this function, you can edit the scenes of the internal programs.
Auto scenes rec.
The moving head features an integrated DMX-recorder by which you can transmit the programmed scenes from your
DMX-controller to the moving head. Adjust the desired scene numbers via the encoder (from – to). When you call up the
scenes at your controller, they will automatically be transmitted to the moving head.
Excursion:
A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master unit can start 3 different Slave units,
which run 3 different programs. The Master unit sends the 3 program parts in a continuous loop.
The Slave unit receives data from the Master unit according to the group which the Slave unit was assigned to. If e.g. a
Slave unit is set to “Slave 1” in the menu “Set to Slave”, the Master unit sends “Auto Program Part 1” to the Slave unit.
If set to “Slave 2”, the Slave unit receives “Auto Program Part 2”.
To start a Auto Program please proceed as follows:
1. Slave-Setting
•Select“FunctionMode”byturning the encoder.
•PresstheEnterbuttontoconfirm.
•Select“Settoslave”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turntheencodertoselect“Slave1”,“Slave2”or“Slave3”.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Esc button in order to return to the main menu.
2. Automatic Program Run
•Select“FunctionMode”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Select“AutoProgram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turnthe encoder to select “Master” or “Alone”. The selection "Alone" means Stand Alone-mode and "Master" that the
device is defined as master.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
3. Program selection for Auto Pro Part
•Select“Editprogram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Select“Selectprograms”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turn the encoder toselect“AutoPro Part 1”, “Auto Pro Part 2” or “Auto Pro Part 3”, and thus select which Slave

- 15 - XM155 V1.0 NR
program is to be sent. Selection “Part 1” means, that the Slave unit runs the same program as the master units.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothe main menu.
4. Program selection for Edit Program
•Select“Editprogram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Select“Editprogram”byturningtheencoder.
•PresstheEnterbuttontoconfirm.
•Turntheencodertoselectthedesired program. With this function you can edit specific scenes into a specific program.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
5. Automatic Scene Recording
•Select“Editprogram”byturningthe encoder.
•PresstheEnterbuttontoconfirm.
•Select“Editscenes”byturningtheencoder.
•Turn the encoder to select the desired scene numbers. You can program a maximum number of 250 •Turn the
encoder to select the desired scene numbers. You can program a maximum number of 250 scenes.
•PresstheEnterbuttontoconfirm.
•PresstheMode/Escbuttoninordertoreturntothemainmenu.
Example:
Program 2 includes scenes: 10, 11, 12, 13
Program 4 includes scenes: 8, 9, 10
Program 6 includes scenes: 12, 13, 14, 15, 16
Auto Pro Part 1 is Program 2;
Auto Pro Part 2 is Program 3;
Auto Pro Part 3 is Program 6
The 3 Slave groups run the Auto Program in certain time segments, as shown in the following picture:

- 16 - XM155 V1.0 NR
INSTRUCTIONS ON USE:
DMX channel´s functions and their values (16 DMX channels):
Channel 1 - Color Wheel :
0-13
Open / white
14-27
Red
28-41
Blue
42-55
Green
56-69
Light yellow
70-83
Rose
84-97
UV filter
98-111
CTO filter
112-127
CTB filter
128-187
Forwards rainbow effect from fast to slow
188-195
No rotation
196-255
Backwards rainbow effect from slow to fast
Channel 2 - Cyan Color Wheel :
0-255
Cyan (0-white, 255-100% Cyan)
Channel 3 - Magenta Color Wheel :
0-255
Magenta (0-white, 255-100% magenta)
Channel 4 - Yellow Color Wheel :
0-255
Yellow (0-white, 255-100% Yellow)
Channel 5 - PAN movement 8bit :
Channel 6 - TILT movement 8bit :
Channel 7 - Speed pan/tilt movement:
0-225
max to min speed
226-235
blackout by movement
236-245
blackout by all wheel changing
246-255
no function
Channel 8 - Effect Wheel:
0-3
Open / white
4-127
Beam shaper indexing
128-189
Forwards rainbow effect from fast to slow
190-193
No rotation

- 17 - XM155 V1.0 NR
194-255
Backwards rainbow effect from slow to fast
Channel 9 – Stepless Zoom
0-255
Zoom adjustment from small to big
Channel 10 - Shutter, strobe:
0-31
Shutter closed
32-63
No function (shutter open)
64-95
Strobe effect slow to fast
96-127
No function (shutter open)
128-159
Pulse-effect in sequences
160-191
No function (shutter open)
192-223
Random strobe effect slow to fast
224-255
No function (shutter open)
Channel 11- Dimmer (intensity):
0-255
Intensity 0 to 100%
Channel 12 - Speed Of CMY And Dimmer:
0-255
Speed Max ->Min
Channel 13 - Color macros - CMY and color wheel:
0-7
OFF 128-135
Macro16
8-15
Macro1 136-143
Macro17
16-23
Macro2 144-151
Macro18
24-31
Macro3 152-159
Macro19
32-39
Macro4 160-167
Macro20
40-47
Macro5 168-175
Macro21
48-55
Macro6 176-183
Macro22
56-63
Macro7 184-191
Macro23
64-71
Macro8 192-199
Macro24
72-79
Macro9 200-207
Macro25
80-87
Macro10 208-215
Macro26
88-95
Macro11 216-223
Macro27
96-103
Macro12 224-231
Macro28
104-111
Macro13 232-239
Macro29
112-119
Macro14 240-247
Macro30
120-127
Macro15 248-255
Random CMY
Channel 14– Lamp on/off, reset, internal programs:
0-19
Color change normal

- 18 - XM155 V1.0 NR
20-39
Color change to any position
40-59
Lamp on
60-79
Lamp switch off
80-84
All motor reset
85-87
Scan motor reset
88-90
Colors motor reset
91-93
No function
94-96
Shutter & Dimmer motor reset
97-99
Other motor reset
100-119
Internal program 1 (scene1~8 of EEPROM)
120-139
Internal program 2 (scene9~16 of EEPROM)
140-159
Internal program 3 (scene17~24 of EEPROM)
160-179
Internal program 4 (scene25~32 of EEPROM)
180-199
Internal program 5 (scene33~40 of EEPROM)
200-219
Internal program 6 (scene41~48 of EEPROM)
220-239
Internal program 7 (scene49~56 of EEPROM)
240-255
Music Control (scene of Program 1)
Channel 15 – Pan fine 16bit
Channel 16– Tilt fine 16bit
ERROR MESSAGE
When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are problems
with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 12, 13, 14, 17, 18 who has the
testing sensor for positioning.
For example, when the display shows “Cyan color Er”, it means there is some error in channel 1. If there are some
errors on channel 1, channel 2, channel 5at the same time, you may see the error message “Color wheel Er”, “Cyan
color Er ”, “Pan movement Er” flash repeated for 5 times, and then the fixture will generate a reset signal, all the
stepper reset. If the fixture remain error message after performing reset more than 3 times, it will detect whether the
fixture has more than 3 errors. If the fixture has more than 3 errors (including 3 errors), all the channels can not
work properly; but if the fixture has less than 3 errors, only the channels which have errors can not work properly,
others can work as usual.
Color wheel Er
(Color wheel-error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The color wheel is not located in the default position after the reset.
Cyan Color wheel Er
(Cyan color wheel-error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The cyan color wheel is not located in the default position after the reset.
Magenta color wheel Er
(Magenta color wheel-error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main

- 19 - XM155 V1.0 NR
PCB). The magenta color wheel is not located in the default position after the reset.
Yellow color wheel Er
(Yellow color wheel-error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The Yellow color wheel is not located in the default position after the reset.
PAN-movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The PAN-movement is not located in the default position after the reset.
TILT-movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The TILT-movement is not located in the default position after the reset.
Zoom Er
(Zoom error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction
(sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Zoom
is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must
not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots
(ceiling, suspension, trussing).
1) Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
2) The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed.
Note: If the external flexible cable or cord of this device is damaged, it shall be exclusively
replaced by the manufacturer or his service agent or a similar qualified person in order to
avoid a hazard.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use
alcohol or solvents.
There are no serviceable parts inside the device except for the lamp. Please refer to the instructions under
“Installation instructions”.
Should you need any spare parts, please order genuine parts from your local dealer.
Table of contents
Other Triton Speakers manuals