www.trolla.dk 4
Cleaning the turbine
(Remove the plug from the power outlet before cleaning operations start)
If there are heavy deposits in the pump body, the lower part must be dismantled as follows:
1. Remove the 4 screws from the lower side of the suction basket.
2. Detach the suction basket from the body of the pump.
3. Clean the pump with clean water.
Warning! Do not put down the pump on the turbine nor hold it by this point either!
4. For reassembly, repeat the above operations in reverse order.
Setting the switch point
The float switch point can be set by adjusting the notches.
Check the following points before switching on:
·The float switch must be installed so that the switch point level can be reached easily with very
little effort. Make sure of this as follows: immerse the pump in a container full of water and lift
the float switch carefully by hand, then lower it. You can thereby check that the pump starts and
stops.
·Make sure that the gap between the head of the float switch and the float switch anchorage
device is not too small. If the gap is not wide enough, perfect operation is not guaranteed.
·Concerning adjustment, make sure that the float switch does not touch the floor before the pump
has stopped. Warning! Risk of running dry.
·To modify the starting level, slide the float cable into the notch provided for the purpose on the
handle.
Anomalies – Sources – Remedies
Anomalies Sources Remedies
The pump won't start - Power not switched on
- The float switch is not
connected to the circuit
- Check the mains voltage
- Lift the float
The pump won't discharge - The intake filter is clogged
- The discharge pipe is stuck - Clean the intake filter with a
water jet- Release the pipe
The pump won't stop - The float switch is blocked in
the upper part - Release the float and
reposition the pump
The flow rate is inadequate - The intake filter is clogged
- Clean the filter and its
environment
The pump stops after working
for a short time - - The water is too hot, the
heat protector stops the pump. - - Make sure the water
temperature does not exceed
35ºC!
“Electrical products must not be thrown out with domestic waste. Recycle them at the special
disposal centres provided for the purpose. Contact your local authorities or stockist for advice on
recycling”.