Trycom Technology TRP-C38 User manual

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
TRP-C38
User’s Manual
Ethernet To 8-Port RS232 Server
Printed MAR. 2007 Rev 1.0
Trycom Technology Co., Ltd
1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC
Tel: 886-2-86781191, Fax: 886-2-86781172
Web: www.trycom.com.tw
Copyright
Copyright Notice: The information in this manual is subject to change without prior notice in order to improve
reliability, design and function and dosed not represent a commitment on the part of the manufacturer. No part of this
manual may be reproduced, copied, or transmitted in any form without the prior written permission of manufacturer.
Acknowledgment Products mentioned in this manual are mentioned for identification purpose only. Products manes
appearing in this manual may or may not be registered trademarks or copyright of their respective companies.

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
2
1 Introduction…………………………………………………………………….………….…….…….3
1-1Feature…………..………………………………………………………………….…….…….…….3
1-2 Specification………………………………………………………………………..…….…………3
2 Hardware Descriptions…………………………………………………………….…….…….…… 4
2-1 Panel Layout…………………..……..……………………………………………….……..………4
2-2 Serial Connection……………………………………………………………………………..……5
2-3 Power Connection……………………..…………………………………………………………...5
2-4 Ethernet Connection……………………..………………………………………………………...5
2-5 Reset Button.......……………………………..…………………………………………………..…5
2-6 Dip Switches.....…………………………………………………………………………………..…5
2-7 DB9 Pin Configurations….…………………………………………………………….……….…6
3 Default Settings……………………………………………………………………………….……....6
4 Install TRP-C38 Hardware………………………………………………………….. …….………...7
4-1 RS485 Wiring……..…………………………………………………………………..……………..7
4-2 RS422 Wiring…………..……………………………………………………………..……………..7
4-3 RS232 ………………..………………………………………………………………..……………..7
4-4 RJ-45 Wiring………..………………………………………………………………….………....…8
5 Install “TRP-C3X Manager” Utility……………………………………………………..…………..8
6 Updating a TRP-C38 Existing Installation……………………………………………………….10
7 How to configure TRP-C38….…………………………………………………………….………..11
7-1 Using TRP-C3X Manager………………………………………..……………………………….11
7-1-1 Searching LAN for TRP-C38………………………………………………………………..…11
7-1-2 Configuring Server Properties………………………………………………………………..12
7-2 Using Console Mode………………………………………………………..…………………….18
7-2-1 Console Mode Hardware Wiring…………………………………………………..………….18
7-2-2 Console Mode Software Install……………………………………………..………………...18
7-3 Using Telnet……………………………………………………………………………….……….20
7-4 Using Web Server………………..………………………………………………………………..22
8 Virtual-Com…………………………………………………………………………………………...22
8-1 Installing Virtual COM Port………………………………………………………………………23
8-2 Configuring Virtual COM Port…………………………………………….……………………..24
8-3 Uninstalling the Virtual COM Port……………………………………………………………...27
8-4 Removing the Virtual COM port with Manager Software…..……….………………………27
8-5 Removing the Virtual COM Port using Device Manager……………………………………27
9 Application……………………………………………………………………………………………28
9-1 Direct IP Mode……………………………………………………………………………………..28
9-2 Virtual COM Mode…………….…………………………………………………………………..28
9-3 Paired Mode…..……………………………………………………………………………………29
9-4 Heart Beat…..………………………………………………………………………………………29
10 Using TRPCOM Utility For Connect RS232/422/485 Device………………………………..30
11 RS232/422 Loop Test……………………………………………………………………………...31
12 Troubleshooting……………………………………………………………………………….......32

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
3
1. Introduction
TRP-C38, a compact, 8-port serial device, is designed to instantly convert data from RS232
interfaces to a 10/100Mbps Ethernet network running at the TCP/IP protocol. By using a
standard COM port and existing network infrastructure the device allow you to link together serial
peripherals that are distant from one another from Windows, Linux and Unix without the need to
install any specific cabling or modify existing software and industry standard DIN rail design
enables fast and professional installation.
The TRP-C38 operates in “Direct IP Mode”, “Virtual COM Mode”, and “Paired Mode”. It has two
synchronous DB-9 serial ports, both equip 10/100 Mbps Ethernet RJ-45 connection. The
Ethernet port will auto-select 10BaseT or 100BaseTX. TRP-C38 also offers a Heart Beat feature
to ensure a reliable communicating connection.
1-1. Features
¾Supports RS-232 serial interface
¾In Server mode supports individual client sessions for security.
¾Virtual COM drivers for Windows NT/98/ME/2000/XP
¾Fully compatible with Ethernet and TCP/IP protocol.
¾Supports 10/100 Mbps Ethernet
¾Supported baud rate up to 230.4 Kbps.
¾Power/Link/COMA ~COMH Flow mode LED indicator.
¾Support intranet and internet system setting function.
¾Support screw terminal and standard external DC power adaptor.
¾Power input requirement from DC +10V to +48V.
1-2. Specification.
zPower Input Voltage: DC +10V to +30V
zSerial Memory: output: 16K bytes per port
Input: 8Kbyteperport
zLAN: 10/100 MbpsAuto-detecting – 10/100Base T.
zSerial Interfaces: RS-232 - TX, RX, RTS, CTS, DTR, DSR, DCD, GND
zData Rate: 110 bps to 230.4 k bps
zParity: none, even, odd, mark, space
zData Bits: 5, 6, 7 or 8
zStop Bits: 1, 1.5 or 2
zProtocol: TCP, IP,ARP, DHCP, Telnet, HTTP, UDP, ICMP
zDin-Rail mountable: Yes.
zPower supply: Screw terminal, or standard external DC adapter.
zPower consumption: 12V/500 mA.
zOperating Temperature: 0 to 65 °C.
zStorage Temperature: -20 to 65 °C.
zHumidity: 0 – 90% Non-Condensing.
zApprovals: CE, FCC.
zDimensions: 120*210*35 mm.
zWeight:638g

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
4
2. Hardware Description
The following information is provided to give the user an understanding of how to connect the
TRP-C38 to the LAN and serial device. Areview of the switch settings and the functionality of the
LED’s are also provided.
2-1. Panel layout
A-TX/RX LED: COM-A RS232 Transiting/Receiving
B-TX/RX LED: COM-B RS232 Transiting/Receiving
C-TX/RX LED: COM-C RS232 Transiting/Receiving
D-TX/RX LED: COM-D RS232 Transiting/Receiving
E-TX/RX LED: COM-E RS232 Transiting/Receiving
F-TX/RX LED: COM-F RS232 Transiting/Receiving
G-TX/RX LED: COM-G RS232 Transiting/Receiving
H-TX/RX LED: COM-H RS232 Transiting/Receiving
DC Jack: Input from +10V to +15V.
(Pleas use the 5.5*2.1*12mm DC JACK).
LINK LED:
Green – 100 Ethernet Connection.
Yellow – 10 Ethernet Connection.
PWR LED: System is ready.(Blinking)

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
5
2-2. Serial Connection
The TRP-C38 has Four DB-9 male connectors. The serial port is configured as a DTE (data
terminal equipment) device. All PC COM ports are DTE ports. A null modem cable is required to
make a connection between the COM port on a PC and the TRP-C38 serial port. A straight
through cable is required to connect the TRP-C38 serial port to a DCE device.
2-3. Power Connection
The TRP-C38 has a two pins terminal block and power jack. Power can apply on either terminal
block or the power jack. It accepts 10~48VDC/500mA power supply. When power is apply a red
light label as run will flash every one second to indicate the system is up and running.
2-4. Ethernet Connection
A straight-through Ethernet cable can be used to connect the serial server to an Ethernet hub,
switch, or wall plate. A crossover Ethernet cable can be used to make a connection directly to the
NIC (Network Interface Card) on a PC or laptop.
2-5. Reset Button
The reset button can be found between the switch and terminal block. To reset the unit manually
apply power, insert a small plastic tool, and press lightly depressing switch. Hold for 3 seconds
and release. The Link and Run light will go out and turn back on. The TRP-C38 will revert to the
last setting.
2-6. Dip Switches
A double DIP switch allows the TRP-C38 to be placed into Console/Loop back/Default/Data
Mode.
When all these switches are moved into the ON position, theTRP-C38 enters Console Mode,
allowing configuration of the TRP-C38 from a PC running a terminal program such as
Hyper-terminal. When the TRP-C38 enters Console Mode, the Console Mode screen will appear
in the Hyper-terminal program window. The serial port settings must be 8-N-1 at 9600 baud.
When the DIP switches are switched to the ON OFF position, the TRP-C38 will work at Loop
back Mode, all data is sent back immediately.
When the DIP switches are switched to the OFF ON position, the TRP-C38 will revert to its
factory version firmware no matter what newer firmware has been upgraded.

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
6
When all of the DIP switches are switched back to the OFF position, the TRP-C38 will enter Data
Mode (RS-232, RS-422 or RS-485).
2-7. DB9 Pin Configuration
Pin RS-232
1 DCD
2 RXD
3 TXD
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
9 RI
3. Default Settings
Model Number: TRP-C38
Password: Blank
DHCP: Disable
IP address: 192.168.1.1
Netmask: 255.255.255.0
Gateway : 192.168.1.254
Version & Date: Current firmware version number and date
Serial port: 2
Baud rate: 9600
Data/Stop bits: 8-1
Parity: None
Flow control: None
Protocol: TCP
Serial timeout: 0 seconds
TCP alive timeout: 0 minutes
Connection mode: Server
Delimiter HEX 1: 00
Delimiter HEX 2: 00
Force transmit: 0 ms
Serial port mode: Console
Maximum connection: 1
Remote IP address: 255.255.255.255

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
7
4. Install TRP-C38 Hardware
STEP1: Connect power source with TRP-C38, if power properly supplies the PWR LED will
blinking.
Warning: User can only choose one of 2 power source, external DC-Jack or Screw
terminal DC input. Do not use external DC-Jack and screw terminal DC input
simultaneously.
STEP2: Connect TRP-C38 with internet port (Ethernet Hub or Switch) by RJ45 LAN cable.
If the cable properly connects the “LINK” LED will light up.
Green: 100MB
Yellow: 10MB
STEP3: Connect TRP-C38 with RS232 or RS422/485 serial device.
4-1. RS232 Wiring
The RS-232 supports 8 channels plus Signal Ground and is configured as DTE like a computer.
Signals are single ended and referenced to Ground. To use handshaking, Flow Control must be
set to RTS/CTS during Configuration. Refer to the Pin out table for connections.
4-2. RJ-45 LAN Cable Wiring Diagram
PC To TRP-C38: Please use crossover Ethernet cable.
HUB To TRP-C38: Please using straight through cable

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
8
5. Install “TRP-C3X Manager” Utility
It is recommended the user install the “TRP-C3X Manager” utility software and do a search for
all TRP-C38 connected to the LAN. When this is completed a window will list the devices making
them available for configuration.
Configuring the serial server to meet your LAN and application requirement is an easy process
with the available setup menu in the “TRP-C3X Manager” software.
5-1. How to install TRP-C3X manager
The following procedure installs the “TRP-C3X Manager” software.
STEP1. Inserting TRP-Series CD, in the CD-ROM and select the TRP-C38 Directory.
Run start.exe.
STEP2. The Install Shield Wizard window automatically display and start the setup procedure.
STEP3. Click the “Next” to continue the installation.

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
9
STEP4. In the Choose Destination Location window select “Next” to install the “TRP-C3X
Manager” software in the default location. (User may select “Browse” to install into
a selected directory)
The installation progress will be shown until complete.
STEP5. Click “Finish” when the Install Shield Wizard Complete screen appears. When the
installation is complete user may access to the Manager software in the program files. If loaded in
the default location Go to Start/Programs/Trycom/TRP-C3X Manager to open.
6. Updating an Existing Installation
If an older version of the Manager software is already installed, the Modify, repair or remove the
program window will appear when the installation process is initiated. The recommended
procedure is to remove all installed components first. Once the software has been removed,
install the new software.

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
10
Highlight remove.
7. How to configure TRP-C38
There are 4 ways to access the Server Properties and program the TRP-C38
1. TRP-C3X Manager software, see 7-1.
2. Console mode, see 7-2.
3. Telnet, see 7-3.
4. Web Server, see 7-4.
7-1. Using TRP-C3X Manager Software
The “TRP-C3X Manager” software performs several functions:
A: Searching for TRP-C38 connected to the network
B: Displaying and changing the configuration of TRP-C38
C: Installing virtual COM ports on a computer
D: Displaying and configuring virtual COM ports
E: Uninstalling virtual COM ports on a computer
F: Upgrading the TRP-C38 firmware
G: Monitoring Port Status
H: Saving and Loading Configuration Files
7-1-1.Searching LAN for TRP-C38
Once TRP-C38 is connected to the LAN the TRP-C3X Manager software will search it and
display it in a window by name and IP address.
A. Select “TRP-C3X Manager” Utility in the program file menu. If the default location was

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
11
selected during the installation the program will be found under “Start/Programs/Trycom
/TRP-C3X” utility. As soon as the “TRP-C3X Manager” Utility opens it will initiate
Searching Server and after a few seconds the Serial Server List will display all
(TRP-C31/32/34) serial servers on the network.
B. To manually initiate a search for servers, on the menu side bar select Searching Server
button. The Search Setup box will appear.
It provides two options for searching for servers on the network:
• Specify the IP address of the Serial Server.
• Search all reachable servers
Enter the IPAddress assigned to the desired Serial Server or click Search all
reachable servers, click “OK”. The Searching window is shown until all active Serial
Servers on the LAN are listed in the Serial Server List window.

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
12
7-1-2.Configuring Server Properties
Highlight the serial server in the Serial Server List window and double click to open the
Server Properties window. The Server Properties window is used to configure and store the
Server configuration settings. Details for setting Properties are described in the next chapter.
After configuring as needed, click Update to store the configuration in the server and click
“Yes” to restart the server to make sure all settings are changed to conform to the desired
application.
Server Name
The server name is user configurable. It is recommended users with more than one TRP-C38
connected to the LAN assign a new name to each. When the Manager software searches for
servers on the LAN it will display the server name allowing the user to distinguish between
TRP-C38s.
Serial Number
Each TRP-C38 has a unique serial number. This is fixed and cannot be changed.
Password
Entering a password activates a security feature on the serial server. Once a password is
entered it will be required to access the menu and make changes.
DHCP
DHCP servers are a part of numerous LAN management systems. The DHCP field has two
selections, “Enable” or “Disable”. Arrow to the desired selection and select enter.
When enabled, TRP-C38 will send a DHCP request to the DHCP server, which will assign a
dynamic IP address, netmask, and gateway to the TRP-C38. If a DHCP server is not available on

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
13
the network the TRP-C38 will time out after 10 seconds and the default values will remain. When
DHCP is enabled, the IP address, Netmask and Gateway fields become inaccessible and cannot
be changed by the user.
IP Address
A static IP address can also be assigned in this section of the menu. A dynamic address
assigned by the DHCP server may change if the TRP-C38 looses the Ethernet connection or
power is removed. The host (client) communication software requests a connection to the
specific IP address of the serial server. If the DHCP reassigns a different IP address the software
will not be able to communicate with the hardware. It is recommended to use a static IP address.
A static IP address is permanent and will not change unless changed in the menu. In most cases
the network administrator establishes the static address to be used.
Netmask
The default LAN netmask is configured for a Class C address. This maybe reconfigured by the
user.
Gateway
The gateway IP address allows users to access the serial server from outside the LAN.
MAC Address
The MAC address is not adjustable. This is assigned in the factory. Every Ethernet device
manufactured has it own unique MAC address.
Version & Date
The currently loaded version of the firmware, and when it was released, are shown here.
Link Status
Link status automatically displays the type of Ethernet connection. It will either display 10 BaseT
or 100BaseTX in full duplex or half duplex. This will depend on the LAN, switches, hubs used in
the LAN topology.
Server Serial Port
This field indicates the number of the port for with serial server properties are currently being
displayed. Changing the number in this field will cause all the other fields to display the
properties for the specified port. Note, however, that before changing ports, any change to
properties must be updated (Saved) or the serial server will not retain them.
Baud Rate
The serial port baud rate on the TRP-C38 must match the serial baud rate of the connected
device unless using Virtual COM mode. In Virtual COM mode the software program will establish

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
14
serial settings.
Data/Parity/Stop
This setting will have to match the data format of the connected device unless using Virtual COM
mode. In Virtual COM mode the software program will establish serial settings.
Flow Control
The flow control setting must match the connected serial device unless using Virtual COM mode.
In Virtual COM mode the software program will establish serial settings.
Protocol
Select TCP or UDP protocol. If the application does not require a UDP connection, select TCP.
TCP guarantees reliable communication with error checking whereas UDP provides faster
transmission.
When UDP mode is chosen the Serial timeout, TCP alive timeout, Connection mode, Connection
at, Maximum connection and Remote IP address fields are replaced with the following three
fields: Destination IP address range, Port number and Source IP address range. In this mode the
server can be configured to broadcast data to and receive data from multiple IP addresses. Four
IP address range fields are provided.
Serial Timeout
Default is 0, or no timeout. Setting timeout to any value between 1 and 65535 seconds activates
it. If communications are idle for specified timeout value the serial server will reset and make
itself available for another connection.
TCP Alive Timeout
This monitors TCP activity. If TCP activity stops for the length of time specified in this field the
connection will be closed. This field can be set to any value between 0 and 255 minutes. If zero,

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
15
or no value, is entered into this field the server will not disconnect.
Connection Mode
The Connection mode field has three options, Server, Client and Client (no heartbeat). When
Client or Client (no heartbeat) is selected, the Connection at field automatically becomes active
(allowing the user to select Power up or Data arrival).
• When using the Virtual COM Port feature, select Server.
• When using a TCP or UDP Socket program, select Server.
• When using Paired Mode communication between two serial servers set up one as a Client
and the other as a Server.
• When connecting to a server that does not support Heartbeat, select Client (no heartbeat).
Delimiter HEX1 and Delimiter HEX 2
These two fields allow the user to enter two ASCII characters (in hex format) that delimit the
beginning and end of a message. When a message with both these delimiters is received at the
serial port, the data contained in the serial buffer is placed in an Ethernet packet and sent out the
Ethernet port. If only Delimiter 1 is set (Delimiter 2 is zero or blank), upon receiving Delimiter 1
the TRP-C38 will put all the data in the serial buffer in an Ethernet packet and send it out the
Ethernet port. If serial data greater than 1 kilobyte is received it will automatically be placed in an
Ethernet packet and sent out the Ethernet port.
Force Transmit
This field allows the user to set a maximum time limit between transmissions of data. The value
set in this field multiplied by 100 ms determines the Force Transmit time. When the elapsed time
reaches the time configured in this field, the TCP/IP protocol will pack the data currently in the
serial buffer into a packet and send it out the Ethernet port.
Port Status
This field indicates whether a serial port is connected to a server or by a client.
TCP/UDP Port
The TCP/UDP Port defines a communication port number. In all modes of operating, Virtual
COM, Direct IP, and Paired modes, both the TCP/UDP Client and server port settings must
match.
For example the Virtual COM defaults setting TCP/UDP Port # 4000. If the port # of the TRP-C38
is changed to 4001, the Virtual COM TCP/UDP Port will have to be changed to 4001.
Serial Port Mode
This allows configuration of the serial server for the following modes of operation:
• Console – When this mode is selected and the server is updated, a PC running a
communication program such as Hyper-terminal can communicate with the

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
16
serial server via the Console Mode serial port (Port 1 on TRP-C38), displaying
the Server Properties screen and allowing configuration of the server and its
ports.
• Upgrade – When this mode is selected and the server is updated, firmware can be uploaded
into the serial server via the Console Mode serial port or a virtual COM port
appeared to the number of the Console Mode serial port.
• Default – When this mode is selected and the server is updated, it will revert the server to
its default configuration.
• RS-232 – When this mode is selected and the server is updated, the selected serial port
will become a RS-232 serial port on the server.
• RS-422 – No support.
• RS-485 – No support.
Connection At
When the Connection Mode field is set to Client or Client (no heartbeat), this field becomes
active, allowing the TRP-C38 (acting as a client) to connect to the server either on Power up or
on DataArrival (first character arriving).
Maximum Connection
This field allows the user to configure the Serial Server to have up to eight TCP connections.
Remote IP Address
This is a security feature that is activated when the IP address of the desired client is
programmed into the remote IP Address setting of the menu. This tells the TRP-C38 to
communicate with only the listed IP address and to filter out all other requests for connection.
The TRP-C38 is setup in the menu as a TCP or UDP server to us this feature.
The default setting is 255.255.255.255. It is recommended not to change this setting until the
application has been tested and is communicating properly. At that point the address filtering
feature of the TRP-C38 can be activated.
Update/Save
Server properties must be updated separately for each serial port. Updating varies slightly
depending on which of the four configuration user interfaces are used.
Updating the Server Properties in Manager Software
From the Server Properties screen, click the Update button to store the configuration settings for

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
17
the currently selected port. The “vcomui” dialogue box will appear indicating you must restart
the device before the new settings will take effect. Click Yes.
7-2 Using Console Mode
The console mode allows access to the TRP-C38 setup menu. This is one way to reconfigure the
default settings for the application. A serial connection is made between a COM port on the PC
and the TRP-C38 serial portA with a null modem cable. In console mode, the serial port defaults
to an RS-232 interface.
The TRP-C38 serial port default settings are, baud rate 9600, 8 data bits, no parity, and 1 stop bit.
Hyper Terminal should be used for this type of setup. Hyper Terminal’s serial settings are
configured the same as the mentioned default settings of the TRP-C38 and must be set to
VT100 emulation mode. The default settings are used only if they have not been changed
7-2-1 Console Mode Hardware Wiring
7-2-2 Console Mode Software Install
STEP1. Select “Hyper Terminal” WINDOWS Utility
Start ---Accessories---Communications --- Hyper Terminal

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
18
STEP2.Select “New Connection” and Enter a name, click “OK”
.
STEP3. Enter the COM Port number that TRP-C38 connect using, click “OK”
STEP4. Press the “Space bar” the TRP-C38 firmware setting screen will show.

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
19
You can set the TRP-C38 by Console mode.
7-3.Using Telnet
Telnet can be used to configure the TRP-C38 Serial Server from any PC on the LAN. The Telnet
window displays the same configuration information shown in Console Mode and allows server
properties to be configured. See chapter 6 for details on Server Properties.
Ensure the PC and TRP-C38 are connected to the LAN, and the serial server is in RS-232,
RS-422 or RS-485 mode before you can telnet to it and access the configuration screens. From
the Desktop, click Start, and then run. The Run dialogue box will open. Type in Telnet and the IP
address of the Serial Server which to be configured, click OK.
STEP1. Select Start then Click “RUN” then key in the “Telnet IP”

ECHIPAMENTE PENTRU AUTOMATIZĂRI
Electric Film S.R.L. — Aleea Scarisoara 3, Apt.42 ▪ Cluj Napoca, Cluj ▪ 400445 ▪ www.electricfilm.eu
VÂNZĂRI ▪ 0364 710319 ▪ electricfilm.eu@gmail.com ▪ SUPORT TEHNIC ▪ 0788 250583
cele mai sensibile
20
STEP2. Click the “OK” TRP-C38 firmware setting will show as following screen. You can set
the TRP-C38 by Telnet mode.
Table of contents
Popular Server manuals by other brands

Fujitsu
Fujitsu PRIMEQUEST 2000 Series installation manual

Lenovo
Lenovo ThinkServer TD230 Informaţii privind garanţia şi suportul

Ebyte
Ebyte NB1A1 user manual

Siemens
Siemens RUGGEDCOM RS910W installation guide

Supermicro
Supermicro SuperServer SYS-421GE-TNRT user manual

Sun Microsystems
Sun Microsystems Sun Fire X4250 Safety and compliance guide