TVT NVMS User manual

NVMS Storage Server
User Manual

16-disk storage server
24-disk storage server
Notes
There may be several technically incorrect places or printing errors in this manual. The updates will
be added into the new version of this manual. The contents of this manual are subject to change
without notice.
This manual is suitable for 16/24-disk storage servers. All the pictures used in this manual are based
on the 16-disk storage server. Please refer to the real servers as the pictures may be different from
the real servers.
The storage server is mainly used with NVMS. This manual only introduces its system setup. Please
refer to the storage server chapter in the NVMS user manual for detailed use.

Contents
1Installation ...............................................................................................................................1
1.1 Interfaces and Indicators......................................................................................................1
1.2 Rear Panel Instruction .........................................................................................................1
1.3 HDD Installation .................................................................................................................2
2Default System Configuration ................................................................................................2
3Web Client Configuration.......................................................................................................3
3.1 Login ...................................................................................................................................3
3.2 Disk RAID ..........................................................................................................................3
3.3 Network Configuration........................................................................................................4
3.4 Server Port Configuration....................................................................................................5
3.5 Change Password ................................................................................................................6
3.6 Basic Information................................................................................................................6
3.7 Date & Time........................................................................................................................6
3.8 Upgrade...............................................................................................................................7
3.9 Device Reboot.....................................................................................................................7
4Q&A..........................................................................................................................................7
5Specifications ...........................................................................................................................8
Appendix Device Installation.......................................................................................................10

NVMS Storage Server User Manual
1
1Installation
1.1 Interfaces and Indicators
The icons below are for reference only. Please refer to the interfaces and indicators of the real
server.
Icon
Description
Icon
Description
Power Key
System disk running indicator; flashing
green light indicators the disk works
normally.
Reset
Error Alarm indicator (including
system/fan/power error alarm)
USB interface
Network connection indicator. Green light
indicators the network connection is
normal.
1.2 Rear Panel Instruction
The following picture of rear panel is for reference only.
16/24-disk

NVMS Storage Server User Manual
2
No.
Description
No.
Description
1
Redundant Power Connector
5
USB3.0 interface
2
Management interface
6
RJ45 interface
3
RS232 interface
7
VGA interface
4
USB2.0 interface
1.3 HDD Installation
①Press the blue button, hold the pull rod to pull out the HDD case and then install the HDD into
the case.
②Fix the HDD by tightening the screws on both side of the case.
③Push the case with the HDD into the slot.
④Fasten the pull rod.
2Default System Configuration
The default network configurations of the server are as follows:
Network Card 1-IP: 192.168.0.10 Network Card 2-IP: 192.168.0.11
Http Port: 8000
To avoid IP conflict you should configure one at a time as these storage servers have the same
default network configuration.

NVMS Storage Server User Manual
3
The default web management page: http://192.168.0.10:8000.
The default username is admin and the default password is also 123456.
The disks installed in one storage server used for RAID should be of the same brand, capacity,
rotate speed and buffer. The production batch should also try to be the same.
3Web Client Configuration
3.1 Login
The storage server is configured through web browser. It is recommended to use IE8or above,
Firefox 51or lower or Google Chrome44 or lower or Opera35 or lower (Here we take IE browser for
example).
Make sure the IP address of the computer is in the same local area network with the storage server
before accessing the storage server, or you will have to modify the IP address of the computer. For
instance, change the computer’s IP address to 192.168.0.100 and the gateway to 192.168.0.1.
Enter http://192.168.0.10:8000 in the IE address bar and then press enter to go to the login interface
as shown below.
Enter the username admin and password 123456 and then click “Login”button to go to the main
interface.
3.2 Disk RAID
Click “Disk Config”tab to go to Disk Configuration interface. Please click “Create”button to create
a disk RAID if you use the storage server for the first time.

NVMS Storage Server User Manual
4
Tips: It is recommended to create Raid5 and check hotspare disk for data security.
Click “Delete”button to pop up a confirmation dialog box. The created RAID will be deleted if you
click “Yes”button. Please be careful to delete the RAID because the record data stored in the RAID
will not be recovered once you delete the RAID.
3.3 Network Configuration
Click “Network Config”tab to go to the interface as shown below. The IP address, subnet mask and
gateway of the storage server can be set in the interface.

NVMS Storage Server User Manual
5
You will get a virtual IP address if the IP group is enabled. As to the access of the virtual IP address,
the operation system of the storage server will judge and transfer the access to eth0 or eth1
automatically.
For instance, if you disconnect the network cable of eth1 when testing “ping 192.168.0.10 –t”, you
will probably get a “Request Timeout”tip if you ping 192.168.0.10; and then you can probably ping
it successfully after a few seconds.
3.4 Server Port Configuration
Click “Port Config”tab to go to the interface as shown below.
Media Transfer Server port: the default number is 6006.

NVMS Storage Server User Manual
6
Auto Report Port: the default number is 2009.
Storage server port: the default number is 6009.
The above-mentioned ports can be modified and enabled as needed.
3.5 Change Password
For safety consideration, it’s strongly recommended to modify the default administrator’s username
and password if you access the storage server for the first time. Click “User Config”tab to go to the
interface as shown below. You can modify the username. Please set a strong password.
3.6 Basic Information
Click “System Maintenance”“Device Basic Information”to view the basic information of the
storage server (like product mode, firmware version, software version, etc).
3.7 Date & Time
It is recommended to set date and time first if you set the storage server for the first time. Click
“Date and Time”tab to go to the interface as shown below.
Select the time zone according to the region. For example, if you are in China, select GMT +08:00.
Set system date and time manually and then click “Apply”to save the settings.

NVMS Storage Server User Manual
7
3.8 Upgrade
You can upgrade the storage server when there is a new software version. Get the upgrade software
from you dealer; click System Maintenance Device Upgrade to go to the interface as shown blow.
Click “Browse”button to select the upgrade file and then click “Upgrade”button to start upgrading.
3.9 Device Reboot
Click System Maintenance Device Reboot to go to the interface as shown blow.
Click “Device Reboot”to reboot the device.
4Q&A
Q1. When the storage server is being started it shows “A discovery error has occurred, please
power cycle the system and all the enclosures attached to this system”.
A1. It indicates that the RAID card could not finish searching in 120 seconds. The system’s SAS
cable may be wrong connected. Please check the cable connection and repair the problems. Then
restart the system later.
Q2. It takes a very long time to rebuild the RAID.
A2. RAID rebuilding time depends on RAID size and the rebuilding process may take more than ten
hours. Recording and playback will not be affected when rebuilding.
Q3. How to replace the abnormal disks in the RAID?
A4. The corresponding disk status indicator will turn red in the disk RAID interface if the disk in the

NVMS Storage Server User Manual
8
RAID is abnormal. Uninstall the abnormal disk in the storage server case and then refresh the
interface; install a new disk after the disk indicator disappears. The RAID will rebuild automatically
later.
5Specifications
Model
16-Disk Storage Server
CPU
Intel Xeon Processor E3-1220V5 4C/4T3.0GHz 8M/80W
Chipset
Intel C232 chipset
OS
CentOS 7.3
Memory
8GB DDR4 ECC, up to 64GB DDR4-1866/2133MHz ECC memory
HDD
3.5 inch SATA×16 (hot-pluggable); built-in 2.5 inch SATA ×2
HDD installation
Independent HDD bracket
Capacity
Up to 128TB
RAID
Hardware RAID; support RAID 0,1,5,6
Expansion
1*PCI-E3.0x16(x8);1*PCI-E3.0x8;1*PCE-E3.0x8(x4)
Network Card
Integrated I210-AT dual gigabit network cards, load balancing and if one is
offline, the other will replace.
IPMI
ASPEED AST2400 BMC, independent IPMI interface; support iKVM
Monitor Control
Integrated display controller
Protocol
Support to get video or audio streams of IPC by TCP / UDP / RTSPprotocol
Search
Built-in index, accurate to second-level
Performance
Up to 900Mbps access and storage
Up to 800Mbps access, 800Mbps storage and 96Mbps playback
Up to 800Mbps access, 800Mbps storage and 96Mbps live view
Way of Management
WEB management, seamless access to NVMS
Capability of
Management
RAID management, record management, system log as well as alarm processing
Security
Supply TPM interface, TPM Module installation supported
Interface
1×VGA, 6×USB(4 in the real panel and 2 in the front panel), 2×RJ45, 1×IPMI,
1×RS232
Power Supply
550W 1+1reduandent power supply, 100~240V-7~3.4A/50~60Hz
Operating
Environment
Working: 10°C to 35°C; standby: –40°C~+55°C(ambient)
Relative Humidity
Working: < 90% RH(35℃)
Noise
Working: <50Dba
ESD
Each item conforms to Intel ambient temperature test standard 15KV

NVMS Storage Server User Manual
9
Model
24-Disk Storage Server
CPU
Intel Xeon Processor E3-1220V5 4C/4T 3.0GHz 8M/80W
Chipset
Intel C232 chipset
OS
CentOS 7.3
Memory
8GB DDR4 ECC, up to 64GB DDR4-1866/2133MHz ECC memory
HDD
3.5 inch SATA×24(hot-pluggable);built-in 2.5 inch SATA×2
HDD installation
Independent HDD bracket
Capacity
Up to 192TB
RAID
Hardware RAID; support RAID 0,1,5,6
Expansion
1*PCI-E3.0x16(×8);1*PCI-E3.0*8;1*PCE-E3.0*8(×4)
Network Card
Integrated I210-AT dual gigabit network cards, load balancing and if one is
offline, the other will replace.
IPMI
ASPEED AST2400 BMC, independent IPMI interface; support iKVM
Monitor Control
Integrated display controller
Protocol
Support to get video or audio streams of IPC by TCP / UDP / RTSPprotocol
Search
Built-in index, accurate to second-level
Performance
Up to 900Mbps access and storage
Up to 800Mbps access, 800Mbps storage and 96Mbps playback
Up to 800Mbps access, 800Mbps storage and 96Mbps live view
Way of Management
WEB management, seamless access to NVMS
Capability of
Management
RAID management, record management, system log as well as alarm processing
Security
Supply TPM interface, TPM Module installation supported
Interface
1×VGA、6×USB(4 in the real panel and 2 in the front panel), 2×RJ45, 1×IPMI,
1×RS232
Power Supply
800W 1+1reduandent power supply, 100~240V-10~5A /50~60Hz
Operating
Environment
Working: 10°C to 35°C; standby: –40°C~+55°C(ambient)
Relative Humidity
Working: < 90% RH(35℃)
Noise
Working: <50Dba
ESD
Each item conforms to Intel ambient temperature test standard 15KV

NVMS Storage Server User Manual
10
Appendix Device Installation
Table of contents
Popular Network Storage Server manuals by other brands

Rasilient
Rasilient ApplianceStor 61 user manual

LevelOne
LevelOne GNS-2000 Brochure & specs

Iomega
Iomega Ix2-200 - StorCenter Network Storage NAS... Specifications

Buffalo
Buffalo LinkStation 500 user manual

LaCie
LaCie 301269U - Ethernet Disk Mini Home Edition 500 GB Network Attached Storage Hard... user manual

Promise
Promise VTrak J5960 quick start guide