UAI PC-300H User manual

Before Installation, Please Read this Manual Carefully
Before Installation, Please Read this Manual CarefullyBefore Installation, Please Read this Manual Carefully
Before Installation, Please Read this Manual Carefully
Please put this manual nearby for
Please put this manual nearby for Please put this manual nearby for
Please put this manual nearby for necessary
necessarynecessary
necessary checking at any moment.
checking at any moment. checking at any moment.
checking at any moment.
PC-300H Indoor Integrated Pan/Tilt
Dome Camera User Manual

2
Safety Precautions
Safety PrecautionsSafety Precautions
Safety Precautions
In order to keep safe installation, please read the followed instructio
In order to keep safe installation, please read the followed instructioIn order to keep safe installation, please read the followed instructio
In order to keep safe installation, please read the followed instruction carefully
n carefully n carefully
n carefully
before installation
before installationbefore installation
before installation
Notice:
1、Compliancy all alarm directions on equipment and manual,
in strict accordance with the requirements
of operation in manual.
2、Do not put equipment on instability desktop, trolley or bracket to avoid damage to equipment.
3、In for to avoid damage to equipment, please power off before cleaning. Do not use any liquid
or spray cleaner; Avoiding any solid foreign bogy or liquid in equipment;
4、Do not installing equipment on instability bracket, wall or ceiling or will lead to accident;
5、When connecting cable, please follow with various electrical safety standard. The RS485 and
video signal all adopted anti thunder technology. Effectively in preventing the damage
caused by less than 500W power thunder, surges and other types of equipment pulse signal.
When RS485 and video signal transmission, please keep a sufficient distance between
RS485, video cable and high voltage equipment. At the same time, the anti-surge, anti
surge protection measure can be arranged when needed.
6、If any fault happened with equipment, do not attempt to disassemble equipment and repair by
yourself. Please connect with supplier in time for all maintenance and repair
7、。No matter be used or not be used, do not aim camera at sun or any high light object. Or will
lead to the permanent damage of camera CCD.
8、
When the malfunction with equipment, do not try to repair it. Please checking fault according to the instruction
on manual. If can’t find out any fault, please connect with us for professional repairman. All repair must be done
with authorized repairman by us.
9、This equipment can’t suffer heavy hit, can’t be used on vibration platform.
10、On engineering, the equipment should avoid prolonged exposure to humidity environment;
Avoid be used in the environment with inflammable gas or corrosive gases;
11、The input voltage is DC12V. Do not input AC22V or AC24V!

3
Product Description
Product Description Product Description
Product Description
In order to meet the growing demand of security products from all society,
We make out one series advance, reliable CCTV products. The 3.5” pan/tilt dome
camera is public applied. This product has one pleasing appearance, construction
consistency with a high cost-effectiveness!
Our integrated pan/tilt dome camera can be set preset point. With excellency
of small size, light weight, easy installation and reliable control. Can be ceiling
mount, recessed mount or wall mount with different installation brackets. The up
cover injected by high-intensity plastic, waterproof, anti-aging, anti-acid rain,
high temperature and corrosion resistance. The low dome is heating molded with
optical standard polypropylene, high transmittance, panoramic unchanged!
Product Characters
Product Characters Product Characters
Product Characters
64 pieces preset point;
High quality board camera, clear image;
Auto scan function;
High preset point precision up to +1
0
with preset point call back;
Specifications
Specifications Specifications
Specifications
Power Supply DC12V±10%
Application Environment Temperature Indoor:0
0
C~+45
0
C
Application Environment Humidity ≤95% no dewing phenomenon
Storage Environment Temperature -40
0
C~60
0
C
Communication Way RS485 Bus control
Baud Rate YINXIN.Pelco-P/9600bps, Pelco-D/2400bps
Horizontal Turning Speed 0.5
0
~40
0
/S
Horizontal Turning Scope 0
0
~350
0
Vertical Turning Speed 0.5
0
~35
0
/S
Vertical Turning Scope 0
0
~90
0
Preset Point Quantity 64 pieces
Address Code Quantity YINXIN: 64; Pelco-P:64; Pelco-D:63;
Lens 3.6mm、4mm、6mm、8mm、12mm available
Installation Way Ceiling Mount, Recessed Mount, Wall Mount selectable
Camera Sensor 1/3”SONY CCD
Camera Resolution 480TVL (Color)
540TVL(Black/white)
Min. Illumination 0.5Lux(Color)
0.13Lux(Black/white)

4
Machine Specifications
Machine Specifications Machine Specifications
Machine Specifications
Size:Ф110mm×105mm
Weight:450G
Construction and Size as followed chat:
Outside Cable Connection Way
Outside Cable Connection WayOutside Cable Connection Way
Outside Cable Connection Way
1、Outside cable connection way:
All outside cables connected to RS485 anti-thunder connector, RS485
anti-thunder connector is connected with pan/tilt dome camera through one 0.5m
8-twisted-pair link cable.
The two terminals of twisted cable have been crimped
with RJ-45 connector. Connected to anti-surge adapter and RJ-45 socket on body
of dome camera. The detailed connection way of RS485 adopter as followed Chart:
ON
A BA B
+12V
GND
JP1
D4
K 5
K3
K1
K2
K4
RS485 anti-surge adapter
K1:RJ45 socket K2:BNC plug K3:RS485 input and output terminal
K4:DC12V input port K5:12VDC input/output port JP1:RS-485 Bus marching resister
D4:Status indicator
K5 DC12V port and K4 DC12V port is connected at inside. You only need to select one
as input port according to different power input terminal.
2. RS485 Bus marching resister
To center control, in order to prevent the reflection and interference of RS485
signal and other communication signals, the communication port of farthest
equipment from control center should parallel connected with one marching resister.

5
On the JP1 of our RS485 anti-surge adapter, there is one terminal matching resistor
jumper switch, insert jumper cap into the two needles which marked ON that means
matching resistor already be accessed to RS485 Bus.
Communication Protocol and Address Code Set
Communication Protocol and Address Code Set Communication Protocol and Address Code Set
Communication Protocol and Address Code Set
1、Communication Protocol and Baud Rate:
On the mother PCB (JP1) of pan/tilt dome, there is a 8 bits dial-Switches , the
last 2 bits be used to set communication protocol. Switching as followed:

6
2、Address Setup:
Before installation, the address of dome camera needed to be set up, the
address is set by the front 6 bits on the 8 bits switch on PCB. Edited with binary
8421 code. 64 pieces addresses can be set. The “ON” ---1, “OFF” ---2. Setup
as followed:
Pelco-D Protocol; Baud Rate 2400bps

7
Yinxin protocol; Baud Rate 9600bps
Pelco-P protocol(continuous command); Baud Rate 9600bps
Pelco-P protocol( not continuous command); baud rate 9600bps

8
◆