What to do if things go wrong
SELF HELP
If the shower is not working satisfactorily, make the following checks before calling out the
contractor. Anyofthese adjustmentscould restore the performance
a) The shower
cycles from HOT
to COLD
The shower temperature is set too hot causing the thermal cut-out
(safetydevice) to operate.
Turn the temperature knob fullyclockwise to increase the water flow.
MEDIUM setting mayneed to be selected.
Slowlyincrease the water temperature byturning knob anti-clockwise
until a comfortable showering temperature has been reached.
You MUSTWAITapproximately20 secondsfor each adjustment to
affect the water temperature.
b) Water too HOT Increase water flowbyadjusting the temperature control clockwise.
Clean sprayplate holes.
Select outer or combination spraypatterns.
Switch power to MEDIUM setting.
Increase pressure of water supplye.g. fullyopen service valve or stop
cock. Checkhose is not kinked restricting the water flow.
c) Watertoo COLD Decrease water flowbyadjusting the temperature control anti-clockwise.
Select inner or outer spraypatternsonly.
Switch power to HIGH setting.
d) Spraypattern
poor Clean sprayplate and flush heater with handset removed.
Select inner / outer spraypattern.
e) Watergoes cold
while using
shower
Check power setting lights are on
Check water pressure has not fallen so far asto let pressure switch cut
out, e.g. another tap drawing water off.
Raise position of handset.
f) Broken parts Please contact our spares department on 0844 372 7750.
Fitting instructions are provided with spares.
PROFESSIONAL SERVICE
If the previous checks fail to restore the performance, you should either contact the
Technical AdvisoryService or seek the assistance ofa qualified plumber and / or electrician.
The person who installed the showeris probablythe best one to repair it and is certainly
the person to contactif you have a problem in the guarantee period.
The following additional checklist is provided for the benefit ofthe qualified serviceman.
WARNING – SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE
REMOVING THE COVER TO MAKE CHECKS.
a) Watertoo HOT Water flowrestricted byblockage in filter of solenoid valve.
Switch off water and undo plastic nut on elbow, loosen brass nut to
swing elbowawayfrom solenoid.
Remove filter in solenoid with long nosed pliers and flush clean.
b) Water too COLD Check circuit through thermal cut-out
Check circuit through microswitch on the pressure switch
Check each element circuit.
Check tightnessofelectrical connections.
c) Water discharge
from pressure
relief valve
Check for cause ofhigh pressure and remove it.
Blockage on outlet i.e. blocked sprayplate.
Replace the pressure reliefdisc (not covered byguarantee).
d) Water does not
flowwhen
button ‘A’, ‘B’
or ‘C’ is pressed
Ensure flying lead from the PCB has been connected to the front cover.
Check the circuit through the solenoid coil.
Check circuit through microswitch
Possible PCB fault, ifdefective, then replace.
Power supplynot reaching shower. 5