Ulvac SPU61A-108 User manual

i
Before using This Instrument
Upon receipt of this detector, make sure that it is the correct model you ordered and that it is not damaged
in transit.
Read this instruction manual before installing, operating, inspecting, or
maintaining the product and fully understand the safety precautions,
specifications and operating procedures regarding the product.
The copyright of this instruction manual is held by ULVAC, Inc.
You are prohibited from copying any portion of this instruction manual without
the consent of ULVAC Inc.
You are also prohibited from disclosing or transferring this instruction manual
to third parties without the express written consent of ULVAC Inc.
The contents described in this instruction manual are subject to change without
prior notice because of changes in specifications or because of product
improvements.
Safety Notations
Safety symbols are used throughout this instruction manual to call the operator's
attention to safety. The terminology used in safety symbols is classified below.
Indicate status of urgency of danger when failure to comply with DANGER
results in serious personal injury or death
The work ignoring this warning will lead to serious damage to human life or
factory facility (including this equipment) at a high probability.
Indicate status of danger when failure to comply with WARNING results in
serious worker’s injury or death.
The work ignoring this warning will cause possibility leading to serious damage
to human life or factory facility (including this equipment)
Indicate status of danger when failure to comply with WARNING results in
minor injury or moderate damage.
The work ignoring this warning will cause possibility leading to minor damage
to worker or breakage to equipment or necessary to adjust.
✔Note
Direct hazard is not existed, describe the necessity to know
from the viewpoint of worker’s safety or correct and safe operation of
equipment

ii
Safety Precautions
Before using the AC adapter for the display ISG1, read this manual and the following safety precautions.
ULVAC is not liable for any accidents or injuries caused by negligence of these safety precautions.
Check line voltage
Before turning on power, make sure that the operating voltage and supply
voltage are in agreement. If incorrect power is applied, damage or fire can
result.
Check line voltage
Use this instrument within the scope of specifications.
Damage or fire can result.
Don’t disassemble
Do not disassemble the AC adapter.
Don’t modify
Do not modify the AC adapter. If modified, its action is not guaranteed.
Also it can be a cause of fire or electric shock.
Grounding
Connect the instrument to ground to prevent electric leak.
Turn off power
If the AC adapter fails, immediately turn off the power. Otherwise, fire or
electric shock can result.
Turn off power
If the AC adapter is overheated or gives out smoke or unusual smell,
immediately turn off the power. Otherwise, fire or electric shock can result.
For safety, contact your local ULVAC representative or ULVAC, Inc.,
Japan for repair.
Operating environment
Do not use this instrument in a place where it may be splashed with water.
If it is wetted with water, failure, electric leak or fire can result.
Check connection
Before turning on power, make sure that the AC adapter is correctly
connected. Otherwise, components may be damaged.
No vibration
See to it that no vibration or impact is given to the AC adapter. If given, it
may be damaged.
Operating conditions
Use this instrument within the scope of specifications.
Caution in repacking and shipping back
Repack the AC adapter as shipped from the factory. If it is shipped bare, it
may be damaged.
Discarding
If the AC adapter and its parts are to be discarded, dispose of them
according to your local government regulations. If the analyzer tube or
parts were used in an environment that can affect the human body, dispose
of them through a disposal company.
Discarding
If this unit is discarded, follow the regulations of your local government.
If the sensor head was used in an environment that can cause danger to
human body, dispose of it through a
specialized refuse disposal agency.
Incidentally, expenses for discarding the instrument are on the user’s
account.

iii
Contents
Page
Before using This Instrument................................................................................................................i
Safety Notations....................................................................................................................................i
Safety Precautions................................................................................................................................ii
Contents .............................................................................................................................................iii
1. Specifications and Components ...........................................................................................1
1.1. Standard Specifications................................................................................................................................1
1.2. StandardAccessories....................................................................................................................................1
1.3. OptionalAccessories....................................................................................................................................1
2. Dimensional Drawing........................................................................................................... 2
3. Installation............................................................................................................................ 3
3.1. PreliminaryOperation..................................................................................................................................3
3.2. Installation.......................................................................................................................................................3
4. Troubleshooting ................................................................................................................... 4
5. Warranty...............................................................................................................................5

1
1. Specifications and Components
1.1. Standard Specifications
Model
SPU61A-108
Input voltage
90 to 264 VAC
Input current
1.45 A @ 100 VAC maximum
Efficiency
88% @ rated load
Frequency
47 to 63 Hz
Output voltage
24 VDC
Output current
2.5 A
Power requirement
60 W
Output variation
±3%
Ripple and noise (Vp-p)
240 mV
Protection
Overvoltage, short-circuit protection, overload protection
Hold up time
<10msec under the condition of typical input with full loading
Operating temperature
0
~
70
℃
Operating humidity
0
~
95%(non-condensing)
Storage temperature
-40
~
85
℃
Storage humidity
0
~
95%(non-condensing)
Reliability
MTBF 100,000 hours min. at max.load
for 25degree centigrade ambient temperature.
Applicable standard
Safety standard: UL/CSA C22.2-No.60950/TUV/IEC60950,PSE
FCC classB,EN 55022 & EN55024 classB
Power cord
(
for Japan
)
PSE
Power cord
(
for Korea
)
SZ04001-1006,SZ4001-1006
Power cord
(
for China
)
CH00717589-2001A,CH004442389-2000
Power cord ( for Germany)
N13389
Power cord ( for USA)
UL/CSA
1.2. Standard Accessories
Power cord
125 VAC, 7 A, 1.8m long, Plug type: type A
1 pc.
1.3. Optional Accessories
Power cord
(
for Korea
)
250VAC, 7 A, 2m long type K
1 pc.
Power cord
(
for China
)
250VAC, 10 A, 2m long type GB
1 pc.
Power cord ( for Germany)
250 VAC, 10A, 1.8m long type CCC7
1 pc.
Power cord( for USA)
125 VAC, 15A, 2m long type A
1 pc.