QUICK REFERENCE GUIDE
Vaisala Surge Protector
WSP152
– Superior 3-stage surge protection
– Tolerates up to 10 kA surge currents
– Both differential and common mode
protection on each channel
– Filtering against HF and RF noise
– Two power channels (±43V, 1.5A) and
two data channels (±13V, 0.16A)
– Designed for use with Vaisala USB cable
220782 for WXT/WMT products
– Adjustable mounting clamp provided for
pole masts, Ø 30 mm … 102 mm
DESCRIPTION
Vaisala Surge Protector WSP152 is a compact-size transient
overvoltage suppressor. It is designed to be used with Vaisala
WXT and WMT transmitters, to protect the host PC against
surges entering through the USB port. For example, a nearby
lightning strike may induce high-voltage surge not tolerable by
the protection of the USB cable or port itself. Thus additional
protection is needed in regions with frequent, severe
thunderstorms, especially when long line cables (>30m) are
used.
Vaisala recommends using the surge protector in installations
where USB cables are used for permanent connections. The
surge protector is always recommended when there is an
elevated risk of lightning strike. The WSP152 also provides
additional filter for blocking the HF and RF interference induced
into the cables in installations to radio transmitter masts, power
line carrier towers etc.
The WSP152 has four channels, two dedicated for power lines
and two for data lines. Each channel uses a three-stage protection
scheme as follows: first there are discharge tubes, then voltage
dependent resistors (VDR), and finally transient zener diodes.
Between each stage there are either series inductors or resistors.
Both differential and common mode protection is provided for
each channel: across the wire pair, against the operating voltage
ground, and against earth.
The WSP152 has a plastic housing with metal reinforcement.
The WSP152 can be mounted on a wall, on the edge of a table,
or to standard Ø 30 mm … 102 mm pole masts with an
adjustable mounting clamp (provided).
0803-059
Figure 1 Operation principle
CAUTION The WSP152 should be placed no further
from the PC than the Vaisala USB cable can
reach (1.8 meters). Do not extend the cable.
INSTALLATION WITH POLE MOUNTING
0803-061
Figure 2 Mounting WSP152 to Pole Mast
Figure 2 illustrates mounting of the WSP152 to a pole mast with
the adjustable mounting clamp. For installation, follow the
procedure below:
1. Fix the steel strip beneath the latch in the back of the
WSP152 unit.
2. Fix the steel strip around the pole mast. You may shorten
the strip to a suitable length.
3. Attach the steel strip ends to the fastener and fasten the
unit to the mast by tightening the fastener's screw.
4. Connect an earthing cable to the connector in the middle
of the WSP152.
5. Connect the USB cable to the M12 connector on the
right side of the WSP152, and the line cable to the left
side.
www.vaisala.com Ref. M210926EN-A
INSTALLATION WITH MOUNTING SCREWS
Mounting screws
0803-060
Figure 3 Mounting WSP152 with Mounting Screws
Figure 3 shows how the WSP152 can be mounted on a wall or
the edge of a table using mounting screws. Follow the procedure
below:
1. Open the 4 plastic screws on the unit cover, and remove
the cover.
2. Insert the mounting screws (not included) in the holes
under the two lowermost plastic screws, and secure the
unit to the desired mounting point (for example, to a wall
or the edge of a table). Select the screws according to the
material of the mounting surface.
Note: The rear plate of the transmitter has threaded M4
holes, so you should use smaller screws.
3. Carefully reattach the enclosure cover with the four
plastic screws.
4. Connect an earthing cable to the connector in the middle
of the WSP152.
5. Connect the USB cable to the M12 connector on the
right side of the WSP152, and the line cable to the left
side.
TECHNICAL DATA
Property Description / Value
Allowed input voltage
(across channel line pair and
from line to GND, terminals #3)
Power channels:
Data channels:
max. ± 43 V
max. ± 13 V
Allowed input common mode
voltage
Any line to earth: max. ± 72 V
Power lines: max. 1.5 AAllowed throughput current
Data lines: max. 0.16 A
Power lines: 0.3 ohmsThroughput resistance
(per line) Data lines: 15 ohms
Power channels: max. ± 60 VTurn-on voltage
Data channels: max. ± 16 V
Surge current To earth:
Differential:
max. 10 kA
max. 5 kA
EMC surge tolerance EN 61000-4-5 (4 kV, 2kA)
IEEE C62.45 (6kV, 3kA)
Installation and maintenance
work temperature
-40 ... +70°C (-40 ... +158°F)
Operating and storage
temperature
-52 ... +70°C (-60 ... +158° F)
Environmental protection class IP54
Dimensions (w × h × d) 130 × 94 × 58 mm
with connectors and mounting
assembly
130 × 120 × 69 mm
Weight 0.65 kg
Housing materials Polycarbonate, stainless steel
Wire dimensions Ø 0.4 - 1.7 mm (AWG 26 - 14)
Connectors M12 / 8-pin Female
M12 / 8-pin Male
WIRING LAYOUT
Figure 4 illustrates the wiring layout inside the WSP152. For
normal operation, it is not necessary to adjust the wiring. Colors
and names are shown for the standard 8-wire M12-cable of
WXT/WMT devices.
The USB cable does not provide heating power for the device,
only the operating power (max. 150mA).
Either RS-232 or RS-485 can be used (depending on WXT/
WMT configuration) with no need of wiring changes on either
side.
0804-001
Figure 4 Wiring Layout of Component Board
DIMENSIONS
16 mm2copp er wire
M12 / 8-pin female
for line cable
M12 / 8-pin male
for Vaisala USB cable
69 (2.72
)
58 (2.28)
130 (5.12)
94 (3.70)
107 (4.21)
0611-028
Figure 5 Dimensions in mm (inch)

Other Vaisala Surge Protector manuals

Vaisala WSP150 User manual

Vaisala

Vaisala WSP150 User manual

Vaisala WSP150 User manual

Vaisala

Vaisala WSP150 User manual

Popular Surge Protector manuals by other brands

Eaton PH Series installation instructions

Eaton

Eaton PH Series installation instructions

CyberPower HT1006U user manual

CyberPower

CyberPower HT1006U user manual

Ilsco SSI SpecPRO CRM 28 Series manual

Ilsco

Ilsco SSI SpecPRO CRM 28 Series manual

CPT CSF21 FB-230 installation instructions

CPT

CPT CSF21 FB-230 installation instructions

LIBERTY AV SOLUTIONS DigitaLinx DL-SP installation guide

LIBERTY AV SOLUTIONS

LIBERTY AV SOLUTIONS DigitaLinx DL-SP installation guide

Monster Power Home Theatre In-Wall PowerCenter 15 AMP owner's manual

Monster Power

Monster Power Home Theatre In-Wall PowerCenter 15 AMP owner's manual

BITS SMART STRIP LCG-3MVR user guide

BITS

BITS SMART STRIP LCG-3MVR user guide

Ilsco SSI SpecPRO SSM 36 Series manual

Ilsco

Ilsco SSI SpecPRO SSM 36 Series manual

Rockwell Automation Allen-Bradley 1609 Series installation instructions

Rockwell Automation

Rockwell Automation Allen-Bradley 1609 Series installation instructions

Weidmüller VPU IoT AC manual

Weidmüller

Weidmüller VPU IoT AC manual

Ditek DR Series installation instructions

Ditek

Ditek DR Series installation instructions

M-system MDK-LC instruction manual

M-system

M-system MDK-LC instruction manual

Ilsco SSI SpecPRO SRM 4 Series manual

Ilsco

Ilsco SSI SpecPRO SRM 4 Series manual

CyberPower HT1206TCU user manual

CyberPower

CyberPower HT1206TCU user manual

Eaton BRSURGECSA Series Installation and operating guide

Eaton

Eaton BRSURGECSA Series Installation and operating guide

CyberPower CSP604U user manual

CyberPower

CyberPower CSP604U user manual

M-system MDK-24 instruction manual

M-system

M-system MDK-24 instruction manual

Philips SPP3224WA Specifications

Philips

Philips SPP3224WA Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.