Valcom VE8006R User manual

1 947490
Issue 3
VE8006R
IP ADMIN I/O MODULE
INTRODUCTION
The VE8006R IP Admin I/O Module allows most
loop start terminal devices to be connected to a
managed IP-based LAN/WAN. The VE8006R is
made specifically for rack mounting (1U).
SPECIFICATIONS
Access Methods
PBX, FXO Port
POTS telephone set
Features
RJ-45 for network connection
4 Relays with Form A contacts
Activity LED
Network activity LEDs
2 RENS
2.5mm jack for external power
Dimensions/Weight
1 Standard 19” Rack Unit
1.75” H x 16.50” W x 5.25” D
(4.45 cm x 41.91 cm x 13.33 cm)
Weight: 5.10 lbs. (2.32 kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm
Output Impedance: 600 Ohms
Output Level: - 10dBm nominal
Relay Current: 1 AMP @ 24VDC
Nominal Power Requirements
Via rear panel barrel connector:
Voltage: 24VDC
Current: 1 AMP
Power Supply Included
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
These products are intended for use with a UL
Listed power source marked “Class 2” or “LPS”
rated 24VDC.
Precautionary Designations
WARNING: To Reduce The Risk Of Fire
Or Electric Shock. Do Not Expose This
Apparatus To Rain Or Moisture.
AVERTISSEMENT: Afin de réduire les
risques d'incendie ou de décharge
électrique, évitez d'exposer le système à
la pluie ou à l'humidité.
Apparatus shall not be exposed to
dripping or splashing and no objects
filled with liquids, such as vases, shall be
placed on the apparatus.
L’appareil ne doit pas être exposé à des
égouttements et éclaboussures et
aucun Objet Rempli de liquide, comme
vase, ne doit être placé sur l’appareil.
NOTE: The telephone system referred to in
this manual is the customer premise
equipment such as an electronic key system,
a PBX or a dedicated single line telephone
sets. The VE8006R is not intended for direct
or indirect connection to the public telephone
network. When used with a customer premise
telephone system such as a key system or
PBX system, these units are interfaced to the
system via a fully protected system central
office port, which is a fully protected interface
device. Also, the host system must be
configured to disallow central office trunk
conferencing in order to prevent indirect
connection to the public network.
A detailed Programming manual is available
at www.ValcomES.com

2 947490
CAUTION: To reduce the risk of electric shock,
Do not remove cover (or back).
No user serviceable parts inside.
Refer servicing to qualified service personnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment.
This equipment generates, uses and can
radiate radio frequency energy and if not
installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential
area may cause harmful interference in which
case the user will be required to correct the
interference at his own expense.
General Mounting Information
A) Elevated Operating Ambient - If installed in a closed
or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater
than room ambient. Therefore, consideration should be
given to installing the equipment in an environment
compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a
rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in
the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given
to the connection of the equipment to the supply circuit
and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be
used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-
mounted equipment should be maintained.
Particular attention should be given to supply
connections other than direct connections to the
branch circuit (e.g. use of power strips).
F) Equipment only suitable for mounting at heights less
than or equal to 2m (6.56’).
INSTALLATION
Mounting
Rack: The VE8006R is designed for the 19” rack
mounting (1U). Following the assembly drawing,
attach the two mounting brackets to the VE8006R
unit. Using rack screws, mount the VE8006R in
an available 1U rack slot. See Figure 1.
Figure 1. Rack Mount
IMPORTANT SAFETY INFORMATION
CONSIGNES DE SÉCURITÉ IMPORTANTES
1. Read these instructions.
Lisez ces instructions.
2. Keep these instructions.
Conservez ces instructions.
3. Heed all warnings.
Respecteztous les avertissements.
4. Follow all instructions.
Suivez toutes les instructions.
5. Do not use this apparatus near water.
Ne pas utiliser cet appareil près de l'eau.
6. Clean only with dry cloth.
Nettoyer avec un chiffon sec.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
Ne pas bloquer les ouvertures de ventilation. Installer formément aux instructions du
fabricant.
8. Do not install near any heat sources such as radiators, heat registers, stoves or other
apparatus (including amplifiers) that produce heat.
Ne pas installer à proximité de sources de chaleur telles que radiateurs, registres de
chaleur, poêles ou autres appareils (y compris les amplificateurs) produisant de la chaleur.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug
has two blades with one wider than the other. A grounding type plug has two blades and a
third grounding prong. The wide blade and the third prong are provided for your safety. If
the provided plug does not fit into your outlet consult an electrician for replacement of the
obsolete outlet.
Ne pas contourner le dispositif de sécurité de la fiche polarisée ou de mise à la terre. Une
fiche polarisée possède deux lames dont une plus large que l'autre. Une fiche de terre a
deux lames et une troisième broche de mise à la terre. La lame large et la troisième
broche sont fournies pour votre sécurité. Si la fiche fournie ne rentre pas dansvotre prise,
veuillez consulter un électricien pour le remplacement de la prise obsolète.
10.Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles and the point where they exit from the apparatus.
11.Only use attachments/accessories specified by the manufacturer.
N'utilisez que des fixations / accessoires spécifiés par le fabricant.
12. Use only with the cart, stand, tripod, bracket or table specified
by the manufacturer or sold with the apparatus. When a cart is
used, use caution when moving the cart/apparatus combination
to avoid injury from tip-over.
Utilisez uniquement avec le chariot, stand, trépied, support ou table spécifié par le
fabricant ou vendu avec l'appareil. Quand un chariot est utilisé, Soyez prudent lorsque
vous déplacez l'ensemble chariot / appareil pour éviter des blessures dues au
renversement.
13. Unplug this apparatus during lightning storms or when unused for a long period of time.
Débranchez cet appareil pendant les orages ou lorsqu'il n'est pas utilisé pendant une
longue période de temps.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way. Such as when the power supply cord or plug is
damaged, liquid has been spilled, objects have fallen into the apparatus or the
apparatus has been exposed to rain or moisture and does not operate normally or has
been dropped.
Confiez toute réparation à un personnel qualifié. Une réparation est nécessaire lorsque
l'appareil a été endommagé de quelque façon. Par exemple lorsque le cordon
d'alimentation ou la fiche est endommagé, du liquide a été renversé, si des objets sont
tombés dans l'appareil ou le appareil a été exposé à la pluie ou à l'humidité et ne
fonctionne pas normalement ou s'il est tombé.

3 947490
ADMIN I/O
.......................
.......................
STATUS
+24V DC
NETWORK
Power Connections
The rear panel barrel connector is used for
power. The preferred power supply is a Valcom
VP-1124D.
Make all required signal connections to a 66M150
punch block. Connect the block to the VE8006R
using a 25 pair, female Amphenol terminated
cable (NOT SUPPLIED) before applying power to
the unit. Plug the cable into the 25 pair jack
labeled ADMIN I/O on the back panel.
Attach the unit to the network via the RJ45
Ethernet connector. Apply power by plugging the
power supply in to the VE8006R via the barrel
connector on the rear of the VE8006R.
Network Connection
The VE8006R has one RJ45 network connector.
Use a standard Ethernet patch cable to connect
the VE8006R to an Ethernet switch.
Signal Connections
Signal connections are made via a 25 pair
Amphenol connector. (See figure 2)
Rear View
Setup
Information specific to your application will need
to be programmed into the VE8006R using a
computer. The PC used for programming should
be connected to the same subnet as the
VE8006R.
Setup will be done using the IP Solutions Setup
Tool. Download the latest version of the free
IP Solutions Setup Tool from Valcom web site
at www.valcom.com/vipsetuptool.
Status Indicator Lights
The VE8006R has 3 status indication lights on
the rear panel:
STATUS: Illuminates at regular intervals during
normal operation. On steady indicates unit is in
reset mode. NOTE: The status LED will
illuminate steady during the initial power on boot
up sequence. Once the unit has successfully
booted, the status indicator will change to an
intermittent flash (approximately 1 second on/1
second off).
The network jack provides two LED indicators:
Green LED: (Link) Indicates Ethernet connection
when illuminated.
Yellow LED: (Activity) Indicator flashes to
indicate network activity.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available,
substitute a spare unit for the suspected
defective unit.
Assistance in troubleshooting is available from
the factory. Call (877) 427-2166 and ask for
Valcom Engineered Solutions Technical Support,
or visit our website at www.ValcomES.com.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating your
company name, address, phone number, contact
person and the nature of the problem. Send the
unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
WARRANTY
Warranty information may be found on our
website at www.valcom.com/warranty.

4 947490
GROUND bl/y
+24Vdc y/or
RELAY 1 (C) y/gr
+24Vdc or/y
RELAY 1 (NO) gr/y
RELAY 2 (C) y/br
RELAY 2 (NO) br/y
RELAY 3 (C) y/sl
RELAY 3 (NO) sl/y
RELAY 4 (C) v/bl
RELAY 4 (NO) bl/v
NO CONNECTION v/or
NO CONNECTION or/v
NO CONNECTION v/gr
NO CONNECTION gr/v
NO CONNECTION v/br
NO CONNECTION br/v
NO CONNECTION v/sl
NO CONNECTION sl/v
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24
50
25
ADMIN PHONE 1 (TIP) w/bl
ADMIN PHONE 1 (RING) bl/w
ADMIN PHONE 2 (TIP) w/or
ADMIN PHONE 2 (RING) or/w
NO CONNECTION w/gr
NO CONNECTION gr/w
NO CONNECTION w/br
NO CONNECTION br/w
+12Vdc w/sl
+12Vdc w/sl
AUXILLARY INPUT 1 r/bl
AUXILLARY INPUT 1 bl/r
AUXILLARY INPUT 2 r/or
AUXILLARY INPUT 2 or/r
NO CONNECTION r/gr
NO CONNECTION gr/r
NO CONNECTION r/br
NO CONNECTION br/r
NO CONNECTION r/sl
NO CONNECTION sl/r
SWITCH 1 INPUT bk/bl
SWITCH 1 INPUT bl/bk
SWITCH 2 INPUT bk/or
SWITCH 2 INPUT or/bk
NO CONNECTION bk/gr
NO CONNECTION gr/bk
NO CONNECTION bk/br
NO CONNECTION br/bk
NO CONNECTION bk/sl
NO CONNECTION sl/bk
NO CONNECTION y/bl
Figure 2. 66M150 Punch Down Block