instabus EIB
Technical Product Information
September 2001
Binary Input N 260 5WG1 260-1AB01
4 x 230 V AC
Product and Applications Description
Siemens AG N 260, 4 pages Technical Manual
The binary input N 260 is a N-system DIN-rail mounted
device with four inputs for AC 230 V switching or keying
signals from separate external outside lines (L1, L2, L3)
with a shared reference potential (N).
Each of the inputs can be assigned various tasks
depending on the application program used, i.e. the
binary input N 260 consists of the device (hardware) and
its application programs (software).
Appropriate application programs are available for
the different tasks the binary input N 260 can handle;
e.g. sending of on/off telegrams at different edges of the
input signal either event-controlled or cyclic with
parametrisable repetition intervals.
With the ETS (EIB Tool Software) the application
program is selected, its parameters and addresses are
assigned appropriately, and downloaded to the binary
input N 260.
Applikationsprogramme
12 S4 BinCycl 240505
• 4 binary inputs
• each input allows switching on/off or toggling at
leading or trailing edge
• allows cyclic sending
• allows sending at bus voltage recurrence
• sending condition can be set
12 S2 On-off-toggle/Dim/Shu 220703
• 4 binary inputs
• allows configuration for dimmer/shutter or
on/off/sending value
• switching at leading edge or at leading and trailing
edge
• switching short/long key depression
• sending value at leading edge or at leading and
trailing edge
• duration of long key depression can be set
• used type of contacts can be set
11 S4 BinVal 240A01
• 4 binary inputs
• each input allows to send values at leading edge
and/or at leading and trailing edge
• allows cyclic sending
• allows delay
• allows interlocking
Example of Operation
instabus EIB
binary input N 260
switching /
keying signals
load circuit
AC 230/400V
L1
bus coupling unit
L2 L3 N
channel A
channel B
channel C
N
channel D
2
4
3
6
1
5
Installation Instructions
• The device may be used for permanent interior
installations in dry locations within distribution boards.
VWARNING
• The device may be built into distribution boards
(230/400 V) if VDE-certified devices are used
exclusively and must be mounted and commissioned
by an authorised electrician.
• A safety disconnection of the device must be possible.
Especially if the device is connected to different
phases.
• Free DIN rail areas must be covered with covers,
order no. 5WG1 192-8AA01.
• The prevailing safety rules must be heeded.
• The device must not be opened. A device suspected
faulty should be returned to the local Siemens office.
Automation and Drives Group
Electrical Installation Technology Siemens AG 2001 Update: http://www.siemens.de/installationstechnik
P.O.Box 10 09 53, D-93009 Regensburg Subject to change without prior notice
2.7.1.3/1
instabus EIB
Technical Product Information
September 2001
Binary Input N 260 5WG1 260-1AB01
4 x 230 V AC
Technical Specifications
Power supply
Technical Manual N 260, 4 pages Siemens AG
via bus cable
Inputs
• 4 inputs
• input signal voltage :
- rated value: AC 230 V
- frequency: 47 ... 63 Hz
- signal ''0'': 0 ... 170 V
- signal ''1'': 198 ... 264 V
• input (signal) current at ''1'':usually 1 mA (at AC 230 V)
• delay of input signal:
- at leading edge of input signal: max. 5 ms
- at trailing edge of input signal: max. 30 ms
• duration of input signal: min. 50 ms
• input characteristic: set in parameter list according to
application program
• length of input signal cable: max. 100 m unshielded
• glow lamps for illuminating push buttons:
maximum number of glow lamps that can be
connected via a bridging module 5TC5 015 to each
input:
- high luminous power (5TG7 342): max. 12 units
- medium luminous power (5TG7 332): max. 18 units
- low luminous power (5TG7 321): max. 60 units
Control elements
1 learning button:
for switching between normal operating mode and
addressing mode
Display elements
1 red LED:
for monitoring bus voltage and displaying mode,
selected with the learning button.
Connections
• signal inputs, physical:
strip insulation for 9 ... 10 mm
permissible conductor types/cross sections:
- 0,5 ... 2,5 mm² single core or flexible conductor,
8 mm ultrasonically compacted
- 0,5 ... 2,5 mm² flexible conductor with terminal pin,
crimped on gas tight
- 0,5 ... 1,5 mm² flexible conductor with connector
sleeve
- 1,0 and 1,5 mm² plain flexible conductor
VWARNING
When looping through the shared N-conductor
(connection blocks 3 and 6), take care that the maximum
connection current of 2 A (as governed by the maximum
permissible printed conductor load) is not exceeded!
• bus line, pressure contacts on data rail
Physical specifications
• housing: plastic
• N-system DIN-rail mounted device,
width: 2 SUs (1SU = 18mm)
• weight: approx. 150 g
• fire load: approx. 2250 kJ ±10 %
• installation: rapid mounting on
DIN EN 50022-35 x 7,5 rail
Electrical safety
• fouling class (according to IEC 664-1): 2
• protection (according to EN 60529): IP 20
• overvoltage class (according to IEC 664-1): III
• bus: safety extra low voltage SELV DC 24 V
• the device complies with
EN 50090-2-2 and EN 60669-2-1
Reliability
rate of failure: 612 fit at 40 °C
Electromagnetic compatibility
complies with
EN 50081-1, EN 50082-2 and EN 50090-2-2
Environmental specifications
• climatic conditions: EN 50090-2-2
• ambient temperature operating: - 5 ... + 45 °C
• ambient temperature non-op.: - 25 ... + 70 °C
• relative humidity (non-condensing): 5 % to 93 %
Certification
EIB certificate
CE norm
complies with the EMC regulations (residential and
functional buildings), and low voltage regulations
Automation and Drives Group
Update: http://www.siemens.de/installationstechnik Siemens AG 2001 Electrical Installation Technology
Subject to change without prior notice P.O.Box 10 09 53, D-93009 Regensburg
2.7.1.3/2
instabus EIB
Technical Product Information
September 2001
Binary Input N 260 5WG1 260-1AB01
4 x 230 V AC
Location and Function of the Display and
Operator Elements
A1
A2
A4
A3
A5
Figure 1: Location of the display and operator elements
A1 LED for indicating normal operating mode (LED off)
and addressing mode (LED on); upon receiving the
physical address the device automatically returns to
normal operating mode
A2 Learning button for switching between normal
operating mode and addressing mode for receiving
the physical address
A3 Type plate
A4 Screwless plug-in terminals for connecting input
circuits
A5 Label for noting the physical address
Mounting and Wiring
General description
The N-system DIN-rail device (2 SUs) can be installed to
N-system distribution boards, surface or flush mounted,
or to any DIN-rail EN 50022-35 x 7,5 available that has a
data rail installed.
The connection to the bus line is established by clicking
the device onto the DIN-rail (with a data rail installed).
Take care that the type plates of all devices on a DIN-rail
can be read in the same direction, guaranteeing the
devices are polarised correctly.
Mounting DIN-rail devices (Figure 2)
- Slide the device (B1) onto the DIN-rail (B2) and
- swivel back the device until the slide clicks into place
audibly.
Dismounting DIN-rail devices (Figure 2)
- Remove all connected wires,
- press down the slide (C3) with a screw-driver and
- swivel the device (C1) from the DIN-rail (C2).
B1
C1
C2
C3
B2
Figure 2: Mounting and dismounting a DIN-rail device
Connecting input circuits (Figure 3)
- The load circuits are connected via screwless plug-in
terminals (D1).
- Remove approx. 9 to 10 mm of insulation from the
wire (D1.1) and plug it into the terminal (D1).
Conductor cross sections:
• signal inputs, physical:
strip insulation for 9 ... 10 mm
permissible conductor types/cross sections:
- 0,5 ... 2,5 mm² single core or flexible conductor,
8 mm ultrasonically compacted
- 0,5 ... 2,5 mm² flexible conductor with terminal pin,
crimped on gas tight
- 0,5 ... 1,5 mm² flexible conductor with connector
sleeve
- 1,0 and 1,5 mm² plain flexible conductor
Disconnect input circuits (Figure 3)
- Press the terminal lock (E1.2) with a screw-driver and
- remove the wire (E1.1) from the terminal (E1).
E1.2
E1
E1.1
D1
D1.1
9 ... 10 mm
Figure 3: Connecting and disconnecting wires
Siemens AG N 260, 4 pages Technical Manual
Automation and Drives Group
Electrical Installation Technology Siemens AG 2001 Update: http://www.siemens.de/installationstechnik
P.O.Box 10 09 53, D-93009 Regensburg Subject to change without prior notice
2.7.1.3/3
instabus EIB
Technical Product Information
September 2001
Binary Input N 260 5WG1 260-1AB01
4 x 230 V AC
Dimensions Diagram
Dimensions in mm
b
90
44
55
45
b = 2 SU
1 Spacer unit (SU) = 18mm
Notes
Technical Manual N 260, 4 pages Siemens AG
Automation and Drives Group
Update: http://www.siemens.de/installationstechnik Siemens AG 2001 Electrical Installation Technology
Subject to change without prior notice P.O.Box 10 09 53, D-93009 Regensburg
2.7.1.3/4

Other Siemens I/O System manuals

Siemens SIMATIC ET 200S User manual

Siemens

Siemens SIMATIC ET 200S User manual

Siemens SIMATIC ET 200SP HA User guide

Siemens

Siemens SIMATIC ET 200SP HA User guide

Siemens SIMATIC ET 200PA SMART Administrator guide

Siemens

Siemens SIMATIC ET 200PA SMART Administrator guide

Siemens Simatic S7-1500 User manual

Siemens

Siemens Simatic S7-1500 User manual

Siemens PPM-1U32.BPR User manual

Siemens

Siemens PPM-1U32.BPR User manual

Siemens 6ES7521-1BL00-0AA0 User manual

Siemens

Siemens 6ES7521-1BL00-0AA0 User manual

Siemens Simatic S7-1500/ET 200MP User manual

Siemens

Siemens Simatic S7-1500/ET 200MP User manual

Siemens SIMATIC ET 200AL User manual

Siemens

Siemens SIMATIC ET 200AL User manual

Siemens SIMATIC ET 200AL User guide

Siemens

Siemens SIMATIC ET 200AL User guide

Siemens SIMATIC ET 200S User manual

Siemens

Siemens SIMATIC ET 200S User manual

Siemens SIMATIC ET 200SP User manual

Siemens

Siemens SIMATIC ET 200SP User manual

Siemens SIMATIC ET 200AL Technical Document

Siemens

Siemens SIMATIC ET 200AL Technical Document

Siemens SIMATIC ET 200AL User guide

Siemens

Siemens SIMATIC ET 200AL User guide

Siemens SICAM A8000 Series User manual

Siemens

Siemens SICAM A8000 Series User manual

Siemens SIMATIC ET 200S User manual

Siemens

Siemens SIMATIC ET 200S User manual

Siemens SIMATIC ET 200S User manual

Siemens

Siemens SIMATIC ET 200S User manual

Siemens SIMATIC ET 200SP Technical Document

Siemens

Siemens SIMATIC ET 200SP Technical Document

Siemens SIMATIC ET 200AL User manual

Siemens

Siemens SIMATIC ET 200AL User manual

Siemens FDCI221 User manual

Siemens

Siemens FDCI221 User manual

Siemens Simatic 6DL2804-1 Series Assembly instructions

Siemens

Siemens Simatic 6DL2804-1 Series Assembly instructions

Siemens Simatic CFU Quick start guide

Siemens

Siemens Simatic CFU Quick start guide

Siemens simatic ET 200MP User manual

Siemens

Siemens simatic ET 200MP User manual

Siemens Simatic ET200pro User manual

Siemens

Siemens Simatic ET200pro User manual

Siemens SIMATIC ET 200AL User guide

Siemens

Siemens SIMATIC ET 200AL User guide

Popular I/O System manuals by other brands

Winbond SpiFlash W25Q256FV manual

Winbond

Winbond SpiFlash W25Q256FV manual

MTT MS3738 user manual

MTT

MTT MS3738 user manual

Pilz PSSu E F BSW operating manual

Pilz

Pilz PSSu E F BSW operating manual

Measurement Computing USB-3105 user guide

Measurement Computing

Measurement Computing USB-3105 user guide

NI FieldPoint FP-AIO-600 operating instructions

NI

NI FieldPoint FP-AIO-600 operating instructions

birddog PLAY user guide

birddog

birddog PLAY user guide

INIM Electronics EM322AC quick start guide

INIM Electronics

INIM Electronics EM322AC quick start guide

AXIOMTEK AX93292 Quick installation guide

AXIOMTEK

AXIOMTEK AX93292 Quick installation guide

Burkert 8642 manual

Burkert

Burkert 8642 manual

Metz Connect IP44SG Mounting Note for the installer

Metz Connect

Metz Connect IP44SG Mounting Note for the installer

GoFlight GF-DIO manual

GoFlight

GoFlight GF-DIO manual

YASKAWA JAPMC-AN2300-E user manual

YASKAWA

YASKAWA JAPMC-AN2300-E user manual

Pioneer PRA-BD11 Service manual

Pioneer

Pioneer PRA-BD11 Service manual

Moxa Technologies ioLogik 2500 Series Quick installation guide

Moxa Technologies

Moxa Technologies ioLogik 2500 Series Quick installation guide

Bürkert 8643 operating instructions

Bürkert

Bürkert 8643 operating instructions

WAGO TEchDocs 765-4501/0100-0000 manual

WAGO

WAGO TEchDocs 765-4501/0100-0000 manual

Allen-Bradley Series B installation instructions

Allen-Bradley

Allen-Bradley Series B installation instructions

Grundfos IO 113 instructions

Grundfos

Grundfos IO 113 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.