INTRODUCTION
The VE8048/VE8048R IP Input/Output Module
allows operation of eight (8) contact closures
which are software programmable as either
Form A or form B. Eight (8) contact closure
activated inputs provide for various programmable
relay functions. The VE8048/VE8048R allows
initiation of VE6001 server events over an IP-
based LAN/WAN. Multiple VE8048/VE8048R
may be deployed on the same network. The
VE8048 is designed for wall or table placement.
The VE8048R is designed for 19” mounting (1U).
SPECIFICATIONS
Features
8 Relay Contacts - Programmable as either
Form A or Form B
8 Contact Closure Inputs
RJ-45 For Network Connection
Front Panel Activity LED
Removable Screw Terminal Connector
Provided For Input And Relay Interface
2.5mm Jack For DC Power (optional)
Power Over Ethernet (PoE) 802.3af
Compatible
No Server Required
1 to 11 Digit Dial Plans
Easy Windows Based Setup
Dimensions/Weight (VE8048)
1.75”H x 6.75" W x 9.5" D
(4.45cm H x 17.15cm W x 24.13cm D)
Weight: 1.75 lbs. (0.80 kg)
Dimensions/Weight (VE8048R)
1.75” H x 16.50" W x 9.50" D
(4.45cm H x 41.91cm W x 24.13cm D)
Weight: 7.80 lbs. (3.54 kg)
VE8048
VE8048R
Nominal Specifications
Input Impedance: 10k Ohms
Relay Current: 1 AMP @ 24VDC
Protocols: DHCP, IGMP v3, UDP, TCP,
HTTP, Telnet, FTP
Nominal Power Requirements
Via Back Panel Barrel Connector:
Voltage: 24VDC
Current: 325mA
Via 802.3af PoE Ethernet Switch:
802.3af: Class 3
Environment
Temperature: +32 to +104°F (0 to +40°C)
Humidity: 0 to 85% Non-Precipitating

2 947697
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
INSTALLATION
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses and can radiate radio
frequency energy and if not installed and used
in accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this equipment
in a residential area may cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
Precautionary Designations
Mounting
The VE8048 is designed for wall or table
mounting. The VE8048R is designed for 19” rack
mounting (1U).
Table: Provided with the VE8048 are four rubber
pads. Peel pads off their carrier backing and
place at the four corners of the bottom of the unit.
Wall: Secure mounting brackets with screws
provided to the VE8011, then secure the VE8048
to the wall. See Figure 1.
Rack: Secure mounting brackets with screws
provided to the VE8048R. See Figure 1. Place
the VE8048R into a standard 19” rack and secure
to rack with proper hardware (not included).
Figure 1.
Power Connections
The preferred method of powering a
VE8048/VE8048R is via a Power over Ethernet
(PoE) switch meeting the 802.3af specification.
If the rear panel barrel connector is used for
power, the preferred power supply is a Valcom
VIP-324.
Make all required signal connections before
applying power to the unit. If powering via 802.3af,
make sure all signal connections via the rear
panel are made then connect the
VE8048/VE8048R to the Ethernet switch.
If power is provided via the barrel connector,
make sure all signal connections are secure.
Attach the unit to the network via the front panel
RJ-45 Ethernet connector. Apply power by
plugging the power supply in to the
VE8048/VE8048R via the barrel connector on the
rear of the VE8048/VE8048R.
Network Connection
The VE8048/VE8048R has one CAT-5 RJ-45
network connector on the front panel.
Use the supplied CAT-5 patch cable to connect
the VE8048/VE8048R to an Ethernet switch. If
the Ethernet switch is 802.3af compliant the
VE8048/VE8048R will draw power from it.
Signal Connections
The VE8048/VE8048R has 16 signal connectors
on the rear panel:
8 Contact Closure Inputs
8 Relay Contacts that are programmable as
Form A or Form B

3 947697
STATUS
LINK
ACT
+24V DC
1 2 3 4 5 6 7 8
INPUTS 1 2 3 4 5 6 7 8
OUTPUTS +-
Status Indicator Lights
The VE8048/VE8048R has 3 status indication
lights on the front panel:
STATUS: Illuminates at regular intervals during
normal operation. On steady indicates unit is in
reset mode..
LINK: Indicates 100 Mbit Ethernet connection
when illuminated. No activity indicates 10 Mbit
connection.
ACT: Indicator flashes to indicate network activity.
Front View
Rear View
Setup
Information specific to your application will need to
be programmed into the VE8048/VE8048R. The
PC used for programming should be connected to
the same subnet as the VE8048/VE8048R. Setup
will be done using the IP Solutions Setup Tool.
Download the latest version of the free IP
Solutions Setup Tool from Valcom website at
www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute
a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the
factory. Call (877) 427-2166 and ask for Valcom
Engineered Solutions Technical Support, or visit
our website at www.ValcomES.com.
When requesting assistance, you should include
all available information. It is strongly suggested
that you go to the web site and follow the trouble
resolution procedure at http://voip.valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of
normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or refund
of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts
and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation,
maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the
specific Product covered by the warranty.
Disclaimer. Except for the Limited Warranty provided herein, the product is provided “as-is” without any warranty of any kind whatsoever including, without
limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road Roanoke, VA 24019-5056
Phone: (540) 563-2000 FAX: (540) 362-9800
This manual suits for next models
1
Other Valcom I/O System manuals