Veko Magnus User manual

MANUAL - VEKO LINEAR LIGHTING SYSTEM
IP65
Magnus
This manual is for usage with shown
product families on this page
in IP65 specification only.
In combination with the following
linear lighting profiles:
PWR-05500
•
PWR-05500-B
•
For further information of applicable
profiles, see section 3 of this manual.
Joris
Justin
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29
1/16

Table of contents
Mounting
Coupling
Mounting brackets
Power feed with cable gland
Power feed with Wieland connectors
Single unit (re-) placement
Sensor MD-L (re-) placement
Sensor configuration(s)
Pool
Emergency LED indicator & battery replacement
Emergency system info & disclaimers
General disclaimers
Page
3, 4
5
6
7
8
9
10
11, 12
13
14
15
16
IP65
2/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Table of contents

Mounting - suspension
1 2
3
4
1 Disconnect the mains.
2 Example of a light-line.
3 In regular conditions a 2 point suspension
is used.
Note
: a light-line consists of multiple part
segments. the middle linepart may vary in quantity.
Note:
measurement F is half of measurement E,
deviding E equally over 2 lineparts.
4 In case of:
- Cable duct
- Sports utility
- Swimming pool
Always use a suspension with at least 3 points.
IP65
Measurement
Recommended
length (mm)
Maximum
length (mm)
A
na.
4600
B
na.
3060
C
750 1150
D
2700 2700
E
2300 2600
F
1150 1300
G
ca. 1500
1700
Measurement
Recommended
length (mm)
Maximum
length (mm)
A
na.
4600
B
na.
3060
C
750 1150
D
ca. 1500
1700
3/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Mounting

Mounting
6 7
8 9 10
11 12 13
14 15
6 In case of mounting in concrete ceiling, Veko
recommends a MM04 anchor or similar with
according drill sizes.
7 In case of using a hook on a sheet piling roof
structure, Veko advises to drill the hole in the
center of the profile.
8 Example with KDW-hook, pendula and steel-
wire (left). KDW-hook, chain and S-hook (right).
9 Always close the links of both the KDW-
and S-hook.
10 Close the link of the S-hook.
11 Close the link of the KDW-hook.
12 Example of mounting with threaded end.
13 Example of mounting with caddy.
14/ 15 When the linear lighting is placed inside
the cannelure of the sheet piling, it's recommended to
use a metal strud or strip to secure the linear lighting
to the metal roof structure.
IP65
KDW-Hook
4/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Mounting

Coupling
1 2
4 5
7 8
10 11
1 Disconnect the mains before operating
the linear lighting system.
2 Example of connected profiles.
Note
: Profile
and/or brackets may vary.
3 The flatcable is provided with a curl for extra
length for an easy connection. Pull out and ex-
tend the flatcable.
-other.
8 Press profiles together.
9 Tighten Hexagon M5 screws (2x) on both
sides of the profiles.
10 Hook the coupling plate into the profiles.
11 Rotate the plate into position.
12 Tighten the slotted M6 bolts (4x).
IP65
6
9
3
12
4 Make sure the male connector is positioned
outside the profile, with the backside onto the
edge of the connection plate.
5 Align both profiles.
6 Insert the connector through the plate
and seals.
7 Make sure connectors firmly 'click' into each-
5/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Coupling

Overview of mounting brackets and couplings
Profile
Mounting
Coupling
Note:
Applicability of bracket may vary, depending on the surrounding, light-line configuration, light-line application and/ or IP-class.
IP65
6/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Bracket overview

Power feed with cable gland
1 2
7 8
10 11 12
13 15
1 Switch off the mains before operating
the linear lighting system.
2 Contents.
3 Use a slotted screwdriver to punch out the
desired hole(s) for the cable gland(s).
4 Remove the remaining piece(s).
5 Fit the cable gland(s).
6 Fasten the cable gland nut(s).
7 Route wiring through the cable gland and
fit with either male or female connector (depen-
ding on counterpart on the linear lighting system).
8 Insert the connector.
9 Connectors should firmly 'click' into eachother.
10 Tighten the M5 hexagon bolts on both sides-
- of the light-line.
11 Hook the coupling plate into the profiles.
12 Rotate the plate into position.
13 Tighten the M6 bolts (4x).
15 After reassuring all electrical connections
are correctly in place and corresponding,
switch the mains back on.
IP65
9
6543
14
Item
Qty.
Power Feed
1x
Connection plate
1x
Connector female
1x
Connector male
1x
Cable gland PG13,5
2x
7/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Power feed with Cable gland

Power feed Wieland
1 2
3
6 7
4
1 Disconnect the mains before operating
the linear lighting system.
2 Contents.
3 Connect the wiring with the flatcable connectors.
4 Connectors should firmly 'click' into eachother.
9 Connect the feed to the main grid using
the Wieland connectors.
10 After reassuring all electrical con-
nections are correctly in place and
corresponding, switch the mains back on.
IP65
5
89 10
5 Place the feed onto the light-line, aligning the
connection plates. Tighten the M5 Hexagon bolts (2x)
on both sides of the light-line.
6 Hook the coupling plate into the profiles.
7 Rotate the plate into position.
8 Tighten the M6 bolts (4x).
Item
Qty.
Power feed
1x
Coupling plate (with
4x slotted M5 bolt)
1x
8/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Power feed Wieland

Single unit (re-)placement
1 2
4 5 6
7
10
1 Disconnect the mains before operating the
linear lighting system.
Note
: Type of unit
and/or profile may vary.
2 Make sure poles and wiring are in correct
position.
3 Insert connector to the flatcable.
4 Press and mount the fallout safety clip into-
9 In case of a sports or emergency unit, place
extra
safety clips onto the unit- and profile,
5 on either side
of the unit, equally devided.
10
Caution
: Bracket may contain sharp edges.
11
Caution
: Make sure wiring doesn't get stuck
between the unit and the profile and
is placed
properly inside the linear lighting system.
- the profile.
5 Press the unit into the profile.
6 Mount the sealing and pressure plate(s)
onto the bracket.
7 Tighten the screw(s).
8 Mount the locking clips (6x), 3 on each side
of a single unit or blindplate.
IP65
11
8
9
3
9/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Single unit (re-) placement

Sensor MD-L (re-)placement
1 2 3
4 5 6
7 8
MD-L-Na
MD-L-R
1 Disconnect the mains before operating the
linear lighting system.
2 Example of sensor.
Note
: type of sensor and/or
profile may vary.
3 Make sure poles and wiring are in correct
position.
4 Insert connector to flatcable.
5 Press and mount the fallout safety clip
into the profile.
6 Fit the sensor unit into the profile
7 In case of the narrow lens, a cover
can be used to limit the reach of the
sensor beam if necessary.
- Length -
- Width -
9
-This cover can be cut to size with pliers
or scissors on the breakline to achieve the desired
reach and angle of the sensor beam.
8 Technical data.
9 Sensor reach:
MD-L-R (round lens)
MD-L-Na (narrow lens)
IP65
Technical data
Power (W)
1,5 W < 4 W (Switched off- < on)
Voltage (V)
220-240 V
Length (mm)
300 mm
Frequency (Hz)
50 ÷ 60 Hz
Circuit
6 A
Sensitivity settings
5 (standard max. sensitivity)
Twilight circuit
Adjustable in 9 steps 0-1.000 Lux
Switch-off delay relay
Relay 0-99 minutes
Environment application
-25 °C - + 35 °C
Corridor function / dynamic switch (example:
10-100 %)
In combination with DALI driver and control
gear
Programming
Readout and re-programmable by colour coding
with LED in sensor
PIR detection angle
Round 130
- 140
ENEC certification
In application at DEKRA
Warrenty
5 years
10/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Sensor (re-) placement

Sensor MD-L-*-RSA configuration
IP65
When the Veko Advanced Relay sensor is plugged into the light-line and connected to power, it will fully function
and perform as a motion
detection sensor. All Veko sensors have a standard configuration. Some of these features are manual adjustable with
a remote control (TR67).
These functions are described in the manual below. You can use this manual on site when a re-configuration is needed,
a maintenance test is
required, or the lights need to be manually overruled.
1 Switch off delay*
The duration of switch
on after detection can
be set between 1 and
max. 99 minutes.
2 Sensitivity detection*
The sensitivity of the
movement detection can
be adjusted according to
your preferences.
3 Sensitivity twilight
mode*
The sensitivity of switch-
on relative to the
available
daylight can
be adjusted.
4 Sensitivity twilight
mode
off*
Switch off twilight mode.
Note
: standard/factory
setting is: off.
5 Check the programmed
setting of:*
5.1 Time frame
light on
5.2 Detection
accuracy
5.3 Sensitivity
twilight
mode
7 Test functions
The lights will flash on
and off for 10 sec.
6 Overrule function
Overrule all current
settings and switched
all lighting on or off
for a set amount of
hours.
Hold until
light responds
Hold until light responds
1x
Fast
Blink
Fast
Blink
Fast
Blink
Fast
Blink
Fast
Blink
Fast
Blink
Fast
Blink
Fast
Blink
Slow
Blink
3x Flash
Solid
Solid
Solid
Solid
3 flashes / colour
3 flashes / colour
3 flashes / colour
3 flashes / Colour
1x
1x
1x
1x
1x
1x
1x
1x
1x
1 = 1 minute
9 = 9 minutes
21 = 21 minutes
3 digits = cancel
1= Low sensitivity
...
5= High sensitivity
1= 100 Lux
...
9= 900 Lux
Flashes blue colour X times for set duration.
Long blink for first digit and short blink for second digit.
Flashes red colour X times for set Lux level.
Flashes 3x red / blue colour when twilight mode is switched off.
Flashes green colour X times for set detection
sensitivitiy.
1 = 1 hour
...
9 = 9 hours
Return to normal
Return to normal mode
Overrule is turned off / canceled
Solid
Solid
Save
Return to normal
* Automatically returns to normal mode, if there is no activity for 20 seconds. Settings will be saved.
Save
Save
Save
Cancel
Cancel
Cancel
Hold until
light responds
Hold until
light responds
Hold until
light responds
Hold until
light
responds
Hold until
light
responds
Hold until light responds
Lighting switched ON
for x hours
Lighting switched OFF
for x hours
1x
Hold until
light responds
Blink
8 Factory settings
Set back all functions
to factory settings
11/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Sensor configuration

Sensor MD-L-*-VSS Configuration
IP65
When the Veko Advanced Relay sensor is plugged into the light line and connected to power, it will fully function
and perform as a motion
detection sensor. All Veko sensors have a standard configuration. Some of these features are manual adjustable with
a remote control (TR67).
These functions are described in the manual below. You can use this manual on site when a re-configuration is needed,
a maintenance test is
required, or the lights need to be manually overruled.
1 Sensitivity detection*
The sensitivity of the
movement detection can
be adjusted according to
your preferences.
2 Sensitivity twilight
mode*
The sensitivity of switch-
on relative to the
available daylight can
be adjusted.
3 Check the programmed
setting* of:
3.1 Detection
accuracy
3.2 Sensitivity
twilight
mode
4 Red LED Setting
The red LED flashes when
detected. This can be turn-
ed off or on.
It's recommended to turn
the red LED off, to prevent
influence on the twilight-
mode sensitivity.
Fast
Blink
Fast
Blink
Fast
Blink
Fast
Blink
Solid
Solid
3 flashes / colour
3 flashes / colour
1x
1x
1x
1x
1= Low Sensitivity
...
5= High Sensitivity
1= 100 Lux
...
9= 900 Lux
Flashes red colour X times for set Lux level.
Flashes green colour X times for set detection
sensitivity.
Save
Save
Cancel
Cancel
Hold until
light responds
Hold until
light responds
Hold until
light
responds
Hold until
light
responds
Hold until
light
responds
3 flashes / colour
Red LED detection flash is turned off or on
* Automatically returns to normal mode, if there is no activity for 20 seconds. Settings will be saved.
12/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Sensor configuration

Pool
IP65
Applicable
products
Profiles Mounting Coupling Suspension
Pool application
Not all standard components can be used in a pool environment. Due to high humidity as well as vapors of chlorine
andcleaning products, high levels of corrosion can occur. To prevent corrosion, all aluminium profiles, including
mounting brackets and coupling pieces (as shown on this page) will be finished with a anodized layer of at least
25μm (according to standard). To protect the LED's, the LED-board will be provided with an extra protective coating.
All used suspension material (as shown on this page) will be hot dip galvanized.
Important notes
After installation, inspection off all used products is necessary due to safety regulations.
This inspection should be on a regular basis and occur at least once a year.
This inspection is the sole responsibility of the end user.
Applicable standards
All Veko swimming pool products and components meet the following standards:
NEN 1010 Safety for low voltage installations;
•
NEN-EN 12193 Lights and lighting - sports lighting;
•
NEN-EN 15288-1 Safety requirements for design;
•
NEN-EN 60598-1 Lighting fixtures - Part 1: General requirements and tests;
•
NEN-EN 60598-2-22 Lighting fixtures - Part 2-22: Particular requirements for emergency lighting fixtures;
•
NPR 9200 Metal suspension structures and fasteners in swimming pools.
•
13/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Pool

Emergency LED indicator & battery replacement
1
5
4
6
7
1 Owner of the building/ luminaires (or acting
party) is obliged to keep a logbook according to
NEN-EN 1838 & NEN-EN-IEC 60598-2-22.
Note
: for specific info on emergency systems see:
section 11 of this manual.
6 Disconnect the battery from the emergency module.
7 Type and/or quantity of batteries may vary as well
as the type of mounting plate.
8 Unscrew the battery from the mounting plate and
replace. Re-tighten screws and reconnect the battery
wires with the emergency module. Replace emergency
unit as described in section 6 of this manual.
2 Before installing the emergency unit or re-
placing the battery, write the installation
date onto the battery.
3 Example of emergency unit indication LED.
4 LED status indicator - table of contents.
5 Disconnect the mains before operating
the linear lighting system.
IP65
23
Date
Logbook
NEN-EN 1838 & NEN-EN-IEC 60598-2-22
8
LED color /
flashing
Error condition
Cause
Solution
Green /
no flashing
System OK, battery fully charged
Off
Main off, EM mode, Rest mode, test in progress
Green /
slow (0,25s on, 1,25s off)
System OK, battery is charging
Green /
fast (0,25s on, 0,25s off)
System OK, recently tested (<5 days, Australia mode only)
Red /
no flashing
Battery voltage too high or too low
No battery connected
Connect battery
Wrong or bad battery connected
Replace battery
Battery pack replaced with different type
Reset driver
Red /
slow (0,25s on, 1,25s off)
Failed test due to battery
Battery end of life
Replace battery and preform duration test
Charger failure
Replace driver
Red /
fast (0,25s on, 0,25s off)
Output voltage too high or to low
Wrong LED load connected
Connect right load and preform functional test
Wrong connection
Connect right load and preform functional test
Red-Green /
fast (0,25s on, 0,25s
off)
Dali device identification
Green /
short (50ms on, 0,95s off)
Battery detection
14/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Emergency LED indicator & Battery replacement

Emergency system info & disclaimer
IP65
Emergency lighting Notes
Owner of the building / luminaires (or acting party instead) is obliged to keep a logbook according to NEN-EN 1838 &
NEN-EN-IEC 60598-2-22 of their emergency installation. The logbook should state at least:
- Installation date of luminaires;
-
Document regular inspection routines;
-
Document replacements and/or maintenance;
-
Logbook should be available for a minimum period of three years;
-
Emergency fittings are foreseen with at minimum one continues power circuit (phase) connection.
When installing
emergency luminaire(s) make sure there is a continues power supply available and connected;
-
After installation it should be avoided that there are any interruptions in this continues power supply.
In case of self-contained emergency:
-
The emergency luminaire(s) can operate between +5 °C to +25 °C with a maximum humidity of 65 % ± 5 %;
-
Before installing the emergency luminaire(s) write the installation date on the battery;
-
The luminaire(s) must be installed within a period of 3 months after production of the luminaire(s);
-
If the luminaire(s) is not connected within a period of 1 month, disconnect the battery from the luminaire;
-
After full installation of all the emergency luminaire(s) a period of 48 hours is required to fully charge the batteries,
afterwards document the functioning of all luminaire(s) for the building operator;
-
Repeated power outages will reduce the lifespan of the batteries dramatically;
-
The emergency luminaire(s) may be discharged max. 4 cycles per year plus 2 cycles during commissioning.
DALI
Each DALI emergency gear is individually addressable on its DALI bus and each gear can be commanded individually to
carry out an emergency test. So rather than testing all the emergency luminaires in one zone together each emergency
luminaire in the zone can be tested at a different time, therefore ensure the safety of the zone at all times.
If the emergency and normal drivers in a luminaire are both DALI gear, then each can be separately addressed
on the same DALI bus. This allows common wiring to be used for both normal lighting control and emergency test
control. During a failure of the permanent mains supply, the TrustSight driver acts autonomously to provide escape
lighting, regardless of the state of the DALI bus.
The TrustSight DALI version is equipped with a self-test functionality according to IEC 62034. Automatic tests will
be preformed according to the duration test (every 52 weeks) and functional test (every 7 days) programmable interval
times. DALI standard operating mode the duration test will be preformed as long as the rated duration time (3 hours).
The automatic duration test will always run until the battery is fully discharged. Full discharges are recommended for
battery maintenance.
Conditions for self-test
The TrustSight driver must be permanently connected to mains power whenever a duration test or functionality test is
executed and the battery must be charging or fully charged. When scheduling a duration or functionality test the
operation of the AC-driver is also checked. When the AC-driver is powered up, the test can be postphoned up to 3 days
(in 24/7 lighting situations). When the AC-driver is off for at least 2 hours the test will be started.
Reset to factory default
In certain cases, it may be required that the TrustSight driver be reset to factory default settings.
This can be achieved in the following way:
Apply mains power and apply 12Vdc on battery input (apply at the same time or within 2s).
1.
After 1s the LED indicator will start flashing fast RED for 2s (4 times).
2.
Remove 12Vdc on battery input while the LED is flashing.
3.
After 1s the LED indicator will light up continuously GREEN for 2s.
4.
Disconnect main power.
5.
The driver has now been reset to its factory default settings.
LED status indicator
The LED status indicator shows whether:
- The system is in charging mode;
-
Batteries are fully charged;
-
A system error had occured, see also the overview table in section 2 of this manual.
15/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Emergency system info & disclaimers

General disclaimers
IP65
Product specifications
- Ambient working range
-25 °C-+35 °C (-13 °F - 95 ° F)
- Storage
-25 °C-+35 °C (-13 °F - 95 ° F)
- Rated voltage range
220 V~-240 V~ 50/60 Hz
- Relative humidity
10 %-85 % RH - not condensing
- Cable specification
7&3 pin suitable for solid wiring (Ø1.5-2.5 mm2)
Important
- Caution, risk of electric shock!
- Hot plug-in is not an option and may cause damage to the luminaire.
- Disconnect the mains before installing or modifying this product.
- Installation and commissioning of the luminaire must be performed by a qualified electrician in accordance with
all national and/or local regulations.
- Install all individual light lines before connecting to the grid.
- NEVER install this product without reading this installation guide.
- NEVER stare into this product when switched on.
- NEVER modify or alter this product, this will result in loss of warranty.
- Read the product labels carefully for all product details.
- This product is not suitable for signal functions, in case of emergency function see next paragraph.
- This product is not suitable for outdoor use.
- This product is not suitable for off-grid power solutions.
- On this product no condensation allowed during storage, operation and application.
- When operating the electrical connections and connecting to the mains or grid always work according to standard
NEN 1010 and NEN 3140.
Note
- A Veko linear lighting system is considered as a single luminaire (a 'closed' system) and not an electrical installation
at itself.
- The light source of this product is custom made and shall only be replaced by the manufacturer or his service agent.
- At end of life, the whole product needs to be replaced.
- This product is not intended for household usage.
- Take care with the usage of power cables and prevent damage to the cables when installing them.
- Avoid touching the product if active, it might cause harm due to heat
- When the product is unpacked, take care of placement. Do not let the product rest on top of the optics,
damage to optics will result in light output loss.
- The manufacturer is not liable for damages resulting from improper of faulty installation or operation from
unauthorized modifications to the luminaire.
- Specifications are subject to change without notice! If you have questions please contact the manufacturer.
- Take appropriate precautions: wear gloves.
When adjusting the length of the light lines between the walls, an expansion coefficient of 24x10 -6 (2.4 mm per 100 m
per °C) should be taken into account.
- Keep at least one copy of this document as future reference material.
Cleaning
- ALWAYS switch off the power to the product before cleaning.
- This product can be cleaned with a damp cloth.
- Choose cleaning materials which are suitable for plastic.
- Do not use coarse or rough cleaning tools on this product.
- Do not use bleach or solvents on this product.
- Do not use any type of high pressure equipment to clean this product.
- Do not submerge this product.
16/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / General disclaimers
This manual suits for next models
2