Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 ighway 74 South Peachtree City, GA 30269 770.468.4800 FAX 770 468.4801 ADV990356
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049
Distance From Fixture Along Wall
I1' 2' 3' 4' 5' 6'
57 48 32 18 952
56 47 33 21 12 63
41 36 28 19 12 74
29 26 21 15 11 84
19 18 15 12 864
14 13 11 9754
10 987543
7765433
5544332
4433322
DD
1
2
3
4
5
6
7
8
9
10
Single Fixture 4' From Wall
Spacing Between Fixtures
I–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––II–––––– 7' ––––––I
76 68 76 67 51 67 62 37 62 59 26 59
80 73 80 68 55 68 62 42 62 59 32 59
67 63 67 56 49 56 49 38 49 46 31 46
51 50 51 43 40 43 37 32 37 34 26 34
38 38 38 32 31 32 28 26 28 25 21 25
29 29 29 24 24 24 21 20 21 19 17 19
22 22 22 18 19 18 16 16 16 14 13 14
17 17 17 14 14 14 13 12 13 11 11 11
13 13 13 11 11 11 10 10 10 989
10 10 10 99 9 88 8 7 7 7
DD
1
2
3
4
5
6
7
8
9
10
Multiple Fixtures 4' Distance From Wall
P H O T O M E T I C S
Distance From Fixture Along Wall
I1' 2' 3' 4' 5' 6'
120 100 63 33 17 84
88 77 54 33 18 10 5
56 52 39 27 17 10 6
33 31 26 19 13 96
21 20 17 13 10 75
14 13 11 9764
9987644
6665443
4444332
3333322
L3232E
DD
1
2
3
4
5
6
7
8
9
10
Single Fixture 3' From Wall
Spacing Between Fixtures
I–––––– 3' ––––––II–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––I
189 186 189 153 133 153 136 95 136 127 66 127
160 160 160 126 118 126 109 88 109 99 68 99
115 118 115 93 91 93 77 70 77 68 55 68
77 80 77 63 63 63 52 51 52 45 41 45
52 54 52 43 44 43 36 36 36 31 30 31
37 38 37 31 31 31 26 26 26 23 22 23
26 27 26 22 23 22 19 19 19 17 17 17
19 19 19 16 17 16 14 15 14 13 13 13
14 15 14 13 13 13 11 11 11 10 10 10
11 11 11 10 10 10 999 8 88
DD
1
2
3
4
5
6
7
8
9
10
Multiple Fixtures 3' Distance From Wall
Test No. 20052
L3232E-LV 3232SC
Specular Louver
Lamp=(2) 32W TTT
Lumens=2,400
45° Aiming Angle
Distance From Fixture Along Wall
I1' 2' 3' 4' 5' 6'
69 62 46 30 18 10 6
61 55 43 29 19 12 7
45 42 34 25 18 12 8
31 30 26 20 15 11 7
21 21 18 15 12 97
15 14 13 11 975
10 10 98764
8776544
6555443
4444332
DD
1
2
3
4
5
6
7
8
9
10
Single Fixture 4' From Wall
Spacing Between Fixtures
I–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––II–––––– 7' ––––––I
106 105 106 91 81 91 82 62 82 76 47 76
102 100 102 85 78 85 76 62 76 70 49 70
84 84 84 70 68 70 60 54 60 55 44 55
65 66 65 55 54 55 47 45 47 42 37 42
48 50 48 41 41 41 35 35 35 31 29 31
36 37 36 31 31 31 27 27 27 24 23 24
27 28 27 23 24 23 20 21 20 18 18 18
21 21 21 18 19 18 16 16 16 14 14 14
16 16 16 14 14 14 13 13 13 11 11 11
12 13 12 11 11 11 10 10 10 999
DD
1
2
3
4
5
6
7
8
9
10
Multiple Fixtures 4' Distance From Wall
Distance From Fixture Along Wall
I1' 2' 3' 4' 5' 6'
120 96 56 27 13 63
92 77 50 29 15 84
57 51 37 24 15 85
35 32 25 18 12 74
22 20 17 13 964
14 14 12 9754
9987544
6665433
4444332
3333221
DD
1
2
3
4
5
6
7
8
9
10
Single Fixture 3' From Wall
Spacing Between Fixtures
I–––––– 3' ––––––II–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––I
178 168 178 147 118 147 133 83 133 127 56 127
155 149 155 123 109 123 108 80 108 100 60 100
109 110 109 88 83 88 74 63 74 67 49 67
74 76 74 61 59 61 50 47 50 44 37 44
51 52 51 42 42 42 35 34 35 30 29 30
36 37 36 30 30 30 26 25 26 22 21 22
26 26 26 22 22 22 18 18 18 16 16 16
19 19 19 16 16 16 14 14 14 12 12 12
14 14 14 12 12 12 10 11 10 999
10 11 10 9 99 88 8 777
DD
1
2
3
4
5
6
7
8
9
10
Multiple Fixtures 3' Distance From Wall
Test No. 20054
L3232E-LV 3232P
White Louver
Lamp=(2) 32W TTT
Lumens=2,400
45° Aiming Angle
Distance From Fixture Along Wall
I1' 2' 3' 4' 5' 6'
67 59 42 26 14 85
65 56 41 27 17 96
46 42 33 23 16 10 6
32 31 25 19 13 10 6
22 21 18 14 11 86
15 15 13 11 865
11 11 98754
8876543
6655433
4444332
DD
1
2
3
4
5
6
7
8
9
10
Single Fixture 4' From Wall
Spacing Between Fixtures
I–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––II–––––– 7' ––––––I
98 92 98 84 70 84 77 53 77 73 40 73
100 93 100 84 72 84 76 56 76 71 44 71
81 78 81 67 63 67 59 50 59 54 40 54
62 62 62 52 50 52 45 41 45 40 33 40
46 47 46 39 38 39 34 32 34 30 27 30
35 35 35 30 29 30 26 25 26 23 21 23
26 27 26 22 23 22 20 20 20 18 17 18
20 21 20 18 18 18 15 15 15 14 13 14
16 16 16 14 14 14 12 12 12 11 11 11
12 13 12 11 11 11 10 10 10 999
DD
1
2
3
4
5
6
7
8
9
10
Multiple Fixtures 4' Distance From Wall
Distance From Fixture Along Wall
I1' 2' 3' 4' 5' 6'
103 78 42 19 831
81 65 40 22 10 52
51 43 30 19 11 53
31 27 21 14 953
19 17 14 10 753
12 11 97543
8875432
5554322
4433222
3322221
DD
1
2
3
4
5
6
7
8
9
10
Single Fixture 3' From Wall
Spacing Between Fixtures
I–––––– 3' ––––––II–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––I
141 127 141 118 86 118 109 58 109 105 37 105
128 119 128 102 85 102 91 61 91 86 44 86
91 89 91 73 66 73 61 49 61 56 38 56
62 62 62 50 47 50 42 37 42 37 29 37
42 43 42 34 34 34 29 27 29 25 22 25
30 30 30 24 24 24 21 20 21 18 16 18
21 21 21 17 18 17 15 15 15 13 12 13
15 15 15 13 13 13 11 11 11 99 9
11 11 11 10 10 10 88 8 77 7
898 777 66 6 666
DD
1
2
3
4
5
6
7
8
9
10
Multiple Fixtures 3' Distance From Wall
Test No. 20053
L3232E-LV 3232MB
Black Louver
Lamp=(2) 32W TTT
Lumens=2,400
45° Aiming Angle
Notes:
• Illuminance values for multiple fixtures are based upon the center two units of a four
unit array. Footcandle values are centerline of fixtures and centered between fixtures.
1 footcandle = 10.76 lux. 1 foot(') = 304.8mm.
• Footcandle Multipliers for 50W (4,000 lumens) = 1.27, for 55W (4,800 lumens) = 1.52
• Illuminance values are cosine corrected initial values with no contribution from inter
reflections from other room surfaces. Total illumination may increase from
contributions from other surfaces.
• Changing fixture spacing will affect illuminance level.
Existing Spacing
New Spacing x Average Table Fc Level