Installation
7. Once the BCM is installed, put batteries in the ther-
mostat
8. Next, the receiver and thermostat will need pairing
A) Hold the top button down on the receiver
until the top LED is ashing quickly
B) Hold down the dial on the thermostat until a
the code shows on the screen
C) Rotate the dial on the thermostat so the code
ashes
D) Wait for the signal icon to appear in the top
right corner of the thermostat screen
(This can take up to ve minutes in some cases)
Once paired, the upper LED on the receiver should be
slowly ashing, and the lower LED should be on and
not ashing
8. Wall mount the thermostat in a suitable place using
the clip on bracket provided.
(Ensure the thermostat is within the signal range using the
signal indicator bars on the screen)
Troubleshooting
The Thermostat will not work unless the BCM is fully
installed and working.
The Thermostat will not work unless the link wire is
installed (as specied in step 2)
If the Thermostat and Receiver will not pair after mul-
tiple tries, follow the instructions on the user manual
to perform a factory reset on the devices.
For usage details, please consult the user manual
Features and Technical Data
Installation
2. Remove any existing thermostats and add a link
wire into the room stat connections on the boiler
3. Remove the cover on the receiver and x it in a
suitable location using an existing or new backbox
4. Wire in the receiver to the BCM backplate as shown
below
(Make sure to also wire in any wires detailed in the BCM instal-
lation guide such as the boiler connection)
Features
7 day programmable heating schedules
Wireless distance: 120M in an open space
Surface mounted Thermostat and Receiver
Holiday Mode
Frost Protection
Technical Data
Set Point Range 5—35°C
Ambient Temperature Reading 0-50°C
Relative Humidity 85°C
Backlight White
Accuracy ±0.5°C
IP Rating IP30
Thermostat Power Source 2x AAA
Receiver Power Source 230V AC
RF Frequency 868/433 Mhz
5. Replace the cover on the receiver and continue
with the BCM installation
6. During the BCM online installation, ensure
“VSThermostat” is ticked on connected devices