manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vericon Systems
  6. •
  7. Thermostat
  8. •
  9. Vericon Systems WTA User manual

Vericon Systems WTA User manual

Wireless Thermostat
Digital Room Thermostat for the BCM:Connect
Pack Contains: 1x Wireless Thermostat, 1x Receiver
Safety and Guidelines
The BCM:Connect (BCM) and Wireless Thermostat
should only be installed by a competent person.
ALWAYS ISOLATE THE MAINS
SUPPLY BEFORE INSTALLING
OR WORKING ON ANY
COMPONENTS THAT REQUIRE
A 230V AC SUPPLY
!
The Wireless Thermostat is intended for internal use
only and requires a BCM to operate.
The Wireless Thermostat has a range of 120m in an
open space from the receiver.
The Receiver should be installed next to the BCM.
The Wireless Thermostat is designed to work with the
BCM:Connect
For more information on the BCM:Connect visit;
www.vericonsystems.com/bcmconnect
Compatibility
Device Information
Wireless Thermostat
Model: WTA
Wireless Thermostat Power: 2x AAA Batteries
Receiver Boiler Connection: 0-24V DC
Receiver Supply Connection: 230V AC
Vericon Systems
Unit 5, Churchill Industrial Estate,
Churchill Road, Cheltenham,
GL53 7EG
www.vericonsystems.com
Support: support@vericonsystems.com
Installation
The thermostat is to be installed during the installation
of the BCM:Connect.
If your BCM:Connect is already installed, re-scan the QR code and follow
the online portal through to reinstall the device with the Thermostat ena-
bled
1. Ensure the mains supply is isolated
ALWAYS ISOLATE THE MAINS
SUPPLY BEFORE INSTALLING
OR WORKING ON ANY
COMPONENTS THAT REQUIRE
A 230V AC SUPPLY
!
Made in China
Installation
7. Once the BCM is installed, put batteries in the ther-
mostat
8. Next, the receiver and thermostat will need pairing
A) Hold the top button down on the receiver
until the top LED is ashing quickly
B) Hold down the dial on the thermostat until a
the code shows on the screen
C) Rotate the dial on the thermostat so the code
ashes
D) Wait for the signal icon to appear in the top
right corner of the thermostat screen
(This can take up to ve minutes in some cases)
Once paired, the upper LED on the receiver should be
slowly ashing, and the lower LED should be on and
not ashing
8. Wall mount the thermostat in a suitable place using
the clip on bracket provided.
(Ensure the thermostat is within the signal range using the
signal indicator bars on the screen)
Troubleshooting
The Thermostat will not work unless the BCM is fully
installed and working.
The Thermostat will not work unless the link wire is
installed (as specied in step 2)
If the Thermostat and Receiver will not pair after mul-
tiple tries, follow the instructions on the user manual
to perform a factory reset on the devices.
For usage details, please consult the user manual
Features and Technical Data
Installation
2. Remove any existing thermostats and add a link
wire into the room stat connections on the boiler
3. Remove the cover on the receiver and x it in a
suitable location using an existing or new backbox
4. Wire in the receiver to the BCM backplate as shown
below
(Make sure to also wire in any wires detailed in the BCM instal-
lation guide such as the boiler connection)
Features
7 day programmable heating schedules
Wireless distance: 120M in an open space
Surface mounted Thermostat and Receiver
Holiday Mode
Frost Protection
Technical Data
Set Point Range 5—35°C
Ambient Temperature Reading 0-50°C
Relative Humidity 85°C
Backlight White
Accuracy ±0.5°C
IP Rating IP30
Thermostat Power Source 2x AAA
Receiver Power Source 230V AC
RF Frequency 868/433 Mhz
5. Replace the cover on the receiver and continue
with the BCM installation
6. During the BCM online installation, ensure
“VSThermostat” is ticked on connected devices
Display and Buttons
Mode Select
Press the M button to change modes.
There are three modes:
- Programmed Mode
- Manual Mode
- Holiday Mode
Wireless Thermostat
Digital Room Thermostat for the BCM:Connect
User Manual
Clock
Weekday
Number
Manual Mode
Current Programming
Period
Signal
Indicator
Heang on
Icon
Setting the Clock and Weekday
Press and hold the M button for 3 seconds.
Set the minute, hour and weekday number by rotating
the dial and pressing M to set the value and moving to
the next value
By clicking the dial button, it will return to the home
screen.
Programming the Thermostat
There are 4 programmable points per day, these can
be set to turn the heating on and o up to twice per
day.
To setup the programmed mode:
- Press and hold the P button for 3 seconds
- Set the time for the 1st setting, in 15 minute intervals,
and press P
- Set the temperature and press P
Repeat for each of the intervals and for each day of
the week.
About the Wireless Thermostat
Features
7 day programmable heating schedules
Wireless distance: 120M in an open space
Surface mounted Thermostat and Receiver
Holiday Mode
Frost Protection
Product Details
Colour White
Backlight White
Accuracy ±0.5°C
IP Rating IP30
Thermostat Power Source 2x AAA
Receiver Power Source 230V AC
RF Frequency 868/433 Mhz
Factory Reset Product Diagrams
Pairing
Hold the top button down on the receiver until the
top LED is ashing quickly
Hold down the dial on the thermostat until a the code
shows on the screen
Rotate the dial on the thermostat so the code ashes
Wait for the signal icon to appear in the top right
corner of the thermostat screen
(This can take up to ve minutes in some cases)
Once paired, the upper LED on the receiver should be
slowly ashing, and the lower LED should be on and
not ashing
Receiver
To factory reset the receiver, hold down both buttons
together until both the lights turn on and don’t ash
The receiver will now reset itself
Thermostat
To factory reset the thermostat, press the dial button
to turn the thermostat o
Then hold the dial button down for 6s to enter the
parameter setting menu
Navigate to menu 17 by pressing the dial button until
17 is displayed in the top left corner
Turn the dial to set menu 17 to 1
Then hold the dial button down for 5s until the ther-
mostat restarts
Lost Connection
If there is a problem connecting to the BCM, the up-
per LED will ash fast until the connection is restored
Parameter Setting
To enter parameter settings, press the dial button to
turn the thermostat screen o and hold the dial but-
ton for 6 seconds.
Adjust the value using the dial, and move to the next
setting by clicking the dial.
Description Default
Value
Menu
Temperature calibration for internal
sensor
0°C
01
Set point max. 35°C
02
Set point min. 5°C03
Frost Protection Temp 5°C05
Dead Zone 0°C
09
Display (0=Room Temp, 1=SET Temp) 0
10
Child Lock (0=O, 1=On) 0
11
Factory Reset (See section overleaf) 017
54 Set point of domestic hot water 45°C
Max set point of boiler water 80°C56

Popular Thermostat manuals by other brands

EPH Controls CDT2-24 operating instructions

EPH Controls

EPH Controls CDT2-24 operating instructions

Honeywell RTH111 series Quick installation guide

Honeywell

Honeywell RTH111 series Quick installation guide

TOTALINE BASIC 1H operating manual

TOTALINE

TOTALINE BASIC 1H operating manual

Propagate PRO PPHTC-1 instruction manual

Propagate

Propagate PRO PPHTC-1 instruction manual

Danfossss TP9000 Installation instructions user instructions

Danfossss

Danfossss TP9000 Installation instructions user instructions

Heatmiser neoUltra manual

Heatmiser

Heatmiser neoUltra manual

LUX TX500E Installation and operating instructions

LUX

LUX TX500E Installation and operating instructions

Danfoss Type CFR user guide

Danfoss

Danfoss Type CFR user guide

Honeywell Home THR860S user manual

Honeywell Home

Honeywell Home THR860S user manual

Stelpro BA Series Installation

Stelpro

Stelpro BA Series Installation

meitav-tec ETNC24-FC-BAC-PIR-01 Owner's manual & technician settings

meitav-tec

meitav-tec ETNC24-FC-BAC-PIR-01 Owner's manual & technician settings

MICRO-AIR EasyTouch RV Installation, Quick Start Guide and Operation Manual

MICRO-AIR

MICRO-AIR EasyTouch RV Installation, Quick Start Guide and Operation Manual

nest Thermostat E installation guide

nest

nest Thermostat E installation guide

easyTherm highcomfort YP3.09997 Installation instructions and using

easyTherm

easyTherm highcomfort YP3.09997 Installation instructions and using

Ferroli TE FC 3V Installation and user manual

Ferroli

Ferroli TE FC 3V Installation and user manual

Heatmiser Slimline-RF manual

Heatmiser

Heatmiser Slimline-RF manual

Honeywell LYRIC T4R Quick start installation guide

Honeywell

Honeywell LYRIC T4R Quick start installation guide

Alpha IP RTA 61001-N1 instruction manual

Alpha IP

Alpha IP RTA 61001-N1 instruction manual

manuals.online logo
manuals.online logoBrands