manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. VERIS INDUSTRIES, INC.
  6. •
  7. Relay
  8. •
  9. VERIS INDUSTRIES, INC. V100DC User manual

VERIS INDUSTRIES, INC. V100DC User manual

Other VERIS INDUSTRIES, INC. Relay manuals

VERIS INDUSTRIES, INC. V101 User manual

VERIS INDUSTRIES, INC.

VERIS INDUSTRIES, INC. V101 User manual

VERIS INDUSTRIES, INC. V102 User manual

VERIS INDUSTRIES, INC.

VERIS INDUSTRIES, INC. V102 User manual

VERIS INDUSTRIES, INC. V222 User manual

VERIS INDUSTRIES, INC.

VERIS INDUSTRIES, INC. V222 User manual

Popular Relay manuals by other brands

Woodward BU1-DC2 manual

Woodward

Woodward BU1-DC2 manual

ABB SSR32 product manual

ABB

ABB SSR32 product manual

Siemens SIRIUS 3UG4633 operating instructions

Siemens

Siemens SIRIUS 3UG4633 operating instructions

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Siemens

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Shelly Pro Series user manual

Shelly

Shelly Pro Series user manual

GE MVAX 11 Technical manual

GE

GE MVAX 11 Technical manual

ABB RELION REF615R manual

ABB

ABB RELION REF615R manual

Kemo Electronic B197 quick guide

Kemo Electronic

Kemo Electronic B197 quick guide

Seg MRM3 manual

Seg

Seg MRM3 manual

Basler BE1-700C manual

Basler

Basler BE1-700C manual

CD Automation REVEX 2PH 280A user manual

CD Automation

CD Automation REVEX 2PH 280A user manual

ABB SPAJ 142 C User manual and technical description

ABB

ABB SPAJ 142 C User manual and technical description

Ruelco 1S04 Operation manual

Ruelco

Ruelco 1S04 Operation manual

Basler V3E Z1P B2C1F instruction manual

Basler

Basler V3E Z1P B2C1F instruction manual

GE DGP instruction manual

GE

GE DGP instruction manual

Kyongbo Electronics GDR-D01 user manual

Kyongbo Electronics

Kyongbo Electronics GDR-D01 user manual

Eaton easyE4 series Application note

Eaton

Eaton easyE4 series Application note

Siemens BD2-AK03X/FS Series installation instructions

Siemens

Siemens BD2-AK03X/FS Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Z203521-0B PAGE 1 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / suppor[email protected] 03121
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
TM
REL AYS INSTALLATION GUIDE
10A SPDT Enclosed Relay
10-30 VDC Coil
Installer’s Specifications
Operating Temperature -34°C to 60°C (-29° to 140°F)
Operating Humidity 10-90% non condensing
Expected Relay Life Electrical (at rated current): 100,000 cycles
Mechanical (unpowered): 10,000,000 cycles
Relay Status LED ON=energized
Wire Specications:
Lead Length 14” (356mm) min.
Gauge UL1015; Coil: 18 AWG; Contacts: 16 AWG
Insulation Class 600 VAC RMS
Agency Approvals UL508 enclosed device listing
V100DC V100DC
DIMENSIONS
NOTICE
• This product is not intended for life or safety applications.
• Do not install this product in hazardous or classified locations.
• The installer is responsible for conformance to all applicable codes.
• Mount this product inside a suitable fire and electrical enclosure.
INSTALLATION
Disconnect and lock out all power sources before beginning the
installation.
1. Using the threaded nipple, connect the relay to the desired enclosure through a
knock out hole.
2. Secure with the conduit nut provided.
3. Connect Coil:
• Choose the coil common lead (white with yellow stripe) and connect it to
the (-) source termination point.
• Choose the low voltage (10-30 VAC/DC, white with blue stripe) lead, and
connect it to the (+) source termination point.*
4. Connect Relay Contacts:
• Choose the relay common wire (yellow) and connect to switched load.
• Choose the relay N.O. (orange) and/or* N.C. (blue) lead and connect to
switched load.
5. Secure the enclosure and reconnect power.
* Isolate or insulate all non-terminated wires according to local electrical code requirements, i.e.
wire nut.
1.6"
(41 mm)
1.7"
(43 mm)
1/2" NPT Nipple
1.8"
(46 mm)
2.9"
(74 mm)
2.8"
(71 mm)
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.
• This equipment must only be installed and serviced by qualied electrical personnel.
• Read, understand and follow the instructions before installing this product.
• Turn o all power supplying equipment before working on or inside the equipment.
• Use a properly rated voltage sensing device to conrm power is o.
DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION
Failure to follow these instructions will result in death or serious injury.
DANGER
Z203521-0B PAGE 2 ©2012 Veris Industries USA 800.354.8556 or +1.503.598.4564 / suppor[email protected] 03121
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
TM
V100DC INSTALLATION GUIDE
N.C.
Common
10-30VDC
LOW
wht/blue
COMM
wht/yellow
Common
N.O.
CONTACT OUTPUTCONTROL SYSTEM INPUT
White
YELLOW
White
ORANGE
b
l
ue
b
l
ue
y
e
ll
o
w
y
e
ll
o
w
WIRING EXAMPLE
Nipple mount directly to a panel
Nipple mount to any 2x or 4x electrical box
To Load
To Controls
COIL
CONTACTS
To Load
To Controls
Wire
Nut
C
O
I
L
CONTACTS
WIRING COLOR CODES
CONTACT AND COIL SPECIFICATIONS
Pull in Voltage DC
10-30V..................................... 9
Drop Out Voltage DC
10-30V..................................... 3
Voltage Coil Current
DC
10V.......................................... 14mA
12V.......................................... 14mA
24V.......................................... 16mA
30V.......................................... 18mA
TYPICAL COIL PERFORMANCE
CONTACT RATINGS
Resistive.............. 10A@277VAC, 28VDC
Motor.................... 120VAC, 1/3HP N.O. & 1/6HP N.C.
240VAC, 1/3HP N.O. & 1/6HP N.C.
277VAC, 1/4HP N.O. & 1/8HP N.C.
Pilot Duty............. 277VAC, (1.7A), 480VA N.O.
Ballast.................. 277VAC, 1.7A
Tungsten...............120VAC, TV3 N.O. TV2 N.C.
Gold Flash............. Yes