manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vernier
  6. •
  7. Adapter
  8. •
  9. Vernier EasyLink EZ-LINK User manual

Vernier EasyLink EZ-LINK User manual

4 1
Warranty
Vernier warrants this product to be free from defects in materials and
workmanship for a period of five years from the date of shipment to the
customer. This warranty does not cover damage to the product caused by abuse
or improper use. This warranty covers educational institutions only.
Vernier Science Education
13979 SW Millikan Way • Beaverton, OR 97005-2886
Toll Free (888) 837-6437 • (503) 277-2299 • Fax (503) 277-2440
[email protected] • www.vernier.com
Rev. 03/01/23
Vernier Easy Link, Vernier EasyData, DataQuest, Logger Pro, Vernier Graphical Analysis, and other marks shown are
our trademarks or registered trademarks in the United States.
TI-Nspire, TI Connect, and TI-SmartView are trademarks of Texas Instruments.
All other marks not owned by us that appear herein are the property of their respective owners, who may or may not be
affiliated with, connected to, or sponsored by us.
Printed on recycled paper
Vernier EasyLink®
(Order Code EZ-LINK)
Vernier EasyLink is a single channel interface that plugs into the USB port of any
TI-Nspire™ handheld or TI-84 Plus graphing calculator. Its flexibility and ease of
use make it perfect for a variety of activities in science and math. EasyLink
supports over 60 analog sensors, including Gas Pressure, pH, and Dual-Range
Force.
Using the Vernier EasyLink with TI-84 Plus (any model)
Follow this general procedure when using Vernier EasyLink with the TI-84 Plus
family of calculators.
1. Confirm that the Vernier EasyData® application is installed on the calculator. Do
that by pressing the button and scrolling through the alphabetical list of
applications. When you know that EasyData is there, press [QUIT] to
return to the home screen. If EasyData is not installed, see below.
2. Connect one of the compatible sensors (listed in the chart) to Vernier EasyLink.
3. Connect Vernier EasyLink to the USB port on the calculator. The calculator will
automatically launch EasyData and detect the sensor.
4. You are now ready to collect data.
For more information about EasyData, visit our website at
www.vernier.com/easydata
Obtaining EasyData
If EasyData is not installed on your TI-84 Plus graphing calculator, you will need to
install it. EasyData can be downloaded free from our website
(www.vernier.com/easydata). Download the application to your computer and then
use a USB computer cable and TI Connect™ or TI Connect CE software to send the
application from the computer to the calculator.
Using Vernier EasyLink with TI-Nspire and TI-Nspire
CAS Handhelds (any model)
1. Confirm that you are running TI-Nspire software version 3.0 or newer.
2. Connect one of the compatible sensors (listed in the chart) to Vernier EasyLink.
3. Turn on the handheld and connect Vernier EasyLink to the USB port on the
handheld. The handheld will launch the DataQuest™application automatically.
The DataQuest app is part of the TI-Nspire operating system version 3.0 or newer. See
your TI-Nspire documentation for additional information on collecting sensor data
using TI-Nspire.
2 3
Sensor
Order
Code
Sensor
Order
Code
30-Volt Voltage Probe
30V-BTA
Instrumentation Amplifier
INA-BTA
25-g Accelerometer
ACC-BTA
Low-g Accelerometer
LGA-BTA
Anemometer
ANM-BTA
Light Sensor
LS-BTA
Ammonium Ion-Selective Electrode
NH4-BTA
Magnetic Field Sensor
MG-BTA
Barometer
BAR-BTA
Melt Station
MELT-BTA
Blood Pressure Sensor*
BP-BTA
Nitrate Ion-Selective Electrode
NO3-BTA
Calcium Ion-Selective Electrode
CA-BTA
O2 Gas Sensor
O2-BTA
Charge Sensor
CRG-BTA
ORP Sensor
ORP-BTA
Chloride Ion-Selective Electrode
CL-BTA
PAR Sensor
PAR-BTA
CO2 Gas Sensor◊
CO2-BTA
pH Sensor
PH-BTA
Colorimeter
COL-BTA
Potassium Ion-Selective
Electrode
K-BTA
Conductivity Probe
CON-BTA
Pyranometer
PYR-BTA
Constant Current System
CCS-BTA
Relative Humidity Sensor
RH-BTA
Current Probe
DCP-BTA
Respiration Monitor Belt
(requires GPS-BTA)
RMB
Dual-Range Force Sensor
DFS-BTA
Salinity Sensor
SAL-BTA
Differential Voltage Probe
DVP-BTA
Soil Moisture Sensor
SMS-BTA
EKG Sensor
EKG-BTA
Sound Level Sensor
SLS-BTA
Electrode Amplifier
EA-BTA
Spirometer
SPR-BTA
Exercise Heart Rate Monitor
EHR-BTA
Stainless Steel Temperature
Sensor
TMP-BTA
Extra Long Temperature Probe
TPL-BTA
Surface Temperature Probe
STS-BTA
Flow Rate Sensor
FLO-BTA
Thermocouple
TCA-BTA
Force Plate
FP-BTA
Tris-Compatible Flat pH Sensor
FPH-BTA
Gas Pressure Sensor
GPS-BTA
Turbidity Sensor
TRB-BTA
Goniometer
GNM-BTA
UVA Sensor
UVA-BTA
Hand Dynamometer
HD-BTA
UVB Sensor
UVB-BTA
Hand-Grip Heart Rate Monitor
HGH-BTA
Voltage Probe
VP-BTA
High Current Sensor
HCS-BTA
Wide-Range Temperature
Probe
WRT-BTA
Sensor
Order
Code
Sensor
Order
Code
30-Volt Voltage Probe
30V-BTA
Instrumentation Amplifier
INA-BTA
25-g Accelerometer
ACC-BTA
Low-g Accelerometer
LGA-BTA
Anemometer
ANM-BTA
Light Sensor
LS-BTA
Ammonium Ion-Selective Electrode
NH4-BTA
Magnetic Field Sensor
MG-BTA
Barometer
BAR-BTA
Melt Station
MELT-BTA
Compatible Analog Sensors
For the most up-to-date list of compatible sensors, go to www.vernier.com/ez-link
Go to www.vernier.com/sensors for more information on any of these sensors.
This interface is equipped with circuitry that supports auto-ID. When used with the
TI-84 Plus or TI-Nspire calculators or TI-SmartView™ CE, TI-Nspire, Logger Pro®,
or Vernier Graphical Analysis®software on a computer°, the data-collection software
identifies the interface and sensor and uses pre-defined parameters to configure an
experiment appropriate for the sensor. This simplifies the experimental set up.
Power Considerations
Vernier EasyLink draws its power and the power for the sensor from the calculator
battery. Both of these power draws will affect the time between charges for
rechargeable batteries or battery lifetime for AAA batteries. Of course, your
specific results will be determined by the amount of use and the type of sensor.
Specifications
12-bit resolution
Maximum sample rate: 200 samples per second
Note: Vernier products are designed for educational use. Our products are not
designed nor recommended for any industrial, medical, or commercial process such
as life support, patient diagnosis, control of a manufacturing process, or industrial
testing of any kind.
Troubleshooting Tips
LED remains red
When the software communicates with Vernier EasyLink, the LED on the Vernier
EasyLink shows the status of the communications. Initially as they communicate, the
LED is red, and then it turns to green when the communications have been
established. If the status remains red, contact Vernier for additional help.
Vernier EasyLink not identified/LED remains off
If the LED is off while the data-collection software is running and your Vernier
EasyLink is attached but not identified, select New from the File menu in the
software. If this fails to resolve the problem, recharging the battery or inserting a
fresh set of AAA batteries will probably solve the problem. If the problem persists,
contact Vernier for additional support.
EasyData does not auto-launch
For TI-84 Plus, verify the Easy Data app is installed. For TI-Nspire, verify the
operating system is 3.0 or newer. If so, check to be sure the calculator’s batteries
are fresh or fully charged. If the data collection app does not auto-launch, leave
Vernier EasyLink attached to the calculator and start the app manually.
*This sensor is not supported in EasyData.
◊This sensor can quickly drain the calculator batteries.
° With the appropriate adapter (order code MINI-USB), Vernier EasyLink can also connect to the USB port of
a computer or LabQuest.

Popular Adapter manuals by other brands

Sony MSAC-M2 operating instructions

Sony

Sony MSAC-M2 operating instructions

Grandstream Networks HT Series Quick user guide

Grandstream Networks

Grandstream Networks HT Series Quick user guide

Geuther 4705AD manual

Geuther

Geuther 4705AD manual

Pilz PSS Series Hardware manual

Pilz

Pilz PSS Series Hardware manual

Conceptronic CHD2SUSB3 Multi Language Quick Guide

Conceptronic

Conceptronic CHD2SUSB3 Multi Language Quick Guide

Revo Mondo DAB operating guide

Revo

Revo Mondo DAB operating guide

Adaptec AHA-3940U installation guide

Adaptec

Adaptec AHA-3940U installation guide

MCC i2cStick user guide

MCC

MCC i2cStick user guide

Festo HGDS Series Assembly instructions

Festo

Festo HGDS Series Assembly instructions

Belden HIRSCHMANN ACA21-USB (EEC) Start-up instructions

Belden

Belden HIRSCHMANN ACA21-USB (EEC) Start-up instructions

Amiga 1000 Kickstart Adapter quick guide

Amiga

Amiga 1000 Kickstart Adapter quick guide

OWC THUNDERBOLT 3 user guide

OWC

OWC THUNDERBOLT 3 user guide

Siemens AEW310.2 manual

Siemens

Siemens AEW310.2 manual

Philips SNU5600/00 quick start guide

Philips

Philips SNU5600/00 quick start guide

Epson ELPAP07 Installing

Epson

Epson ELPAP07 Installing

Giacomini GE552Y050 user guide

Giacomini

Giacomini GE552Y050 user guide

PowerPac PP8733 instruction manual

PowerPac

PowerPac PP8733 instruction manual

Abocom WBD512 Installation

Abocom

Abocom WBD512 Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.