User's Guide of Digital Mini Multimeters DT-16/DT-18
DCV-400mV or ACV-4V, and the "AUTO" characters on the LCD
disappears. If measuring the higher voltage at this point, please
toggle function rotary switch or shut down the instrument, and re-
set the DCV/ACV as automatic range and test.
6.5 RANGE Button
Boot by default auto range, press the button to switch to
manDTl range. Under manDTl range, jump up a le when press this
button one time. When jumping to the most upscale and continuing
to press this button, the button will go to the low-grade, and followed
by this cycle. If press this button over 2 seconds, and the switch will
go back to the automatic range state.
6.6 MAXH Button
The A/D conversion will continue to work if press this button, and
the display value will always update and remain the maximum
value.
6.7 Auto power off
For DT-16, during the measurement, the instrument will be in
“Automatic Shutdown” (hibernation) to conserve power, if the
function keys and dial switch have no action within 15 minutes. And
press HOLD button to switch on the instrument then the auto power
off function will be cancelled. Under auto power off state, press
function keys or turn the dial switch, and the instrument will switch
on automatically.
Cautions: Under the sleeping mode, press the HOLD button
to wake the instrument, and the auto power off function will be
cancelled.
For DT-18, during the measurement, the instrument will be in
“Automatic Shutdown” (hibernation) to conserve power, if the
function keys and dial switch have no action within 30 minutes. And
press SELECT button to switch on the instrument then the auto