Diode Test
Overload
Protection
Test Current
(Typical)
Open Circuit
Voltage Range
600V RMS 0.25mA <1.6V DC 2.0V DC
Continuity Test
Overload Protection Open Circuit Voltage
600V RMS Appx. 0.44V
WARRANTY
This product is warranted to be free from defects in materials and workmanship for a
period of two years from the date of purchase. During this warranty period, Klein Tools
has the option to repair or replace or refund the purchase price of any unit which fails to
conform to this warranty under normal use and service. This warranty does not cover dam-
age which occurs in shipment or failure which results from alteration, tampering, accident,
misuse, abuse, neglect, or improper maintenance. Batteries and damage resulting from
failed batteries are not covered by warranty. A purchase receipt or other proof of original
purchase date will be required before warranty repairs will be rendered.
Any implied warranties, including but not limited to implied warranties of merchantability
and fitness for a particular purpose, are limited to the express warranty. Klein Tools shall
not be liable for loss of use of the instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for such damage, expenses or
economic loss.
Some states or countries laws vary, so the above limitations or exclusions may not apply
to you. This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state. If your Klein product requires repair or for information on
how to exercise your rights under the terms of this warranty, please contact Klein Tools at
1-877-775-5346.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time. Do not
expose to high temperatures or humidity. After a period of storage in extreme conditions
exceeding the limits mentioned in the Specifications section, allow the instrument to return
to normal operating conditions before using it.
DISPOSAL /RECYCLE
Caution: This symbol indicates that equipment and its accessories shall
be subject to a separate collection and correct disposal.
DC Current Measurement
Range Resolution Accuracy
400µA ~ 400mA 0.1µA ˜0.1mA ± (1.0% + 5 digits)
4A ~ 10A 1mA ˜10mA ± (1.5% + 5 digits)
Overload Protection:
• uAmA Input: 400mA (F 440mA /1000V fuse)
• A Input: 10A (F 11A / 1000V fuse)
AC Current Measurement Accuracy
Range Resolution 40Hz ~400Hz 400Hz ~ 10kHz
400
µ
A ~ 400mA 0.1
µ
A ˜0.1mA ± (1.2% + 5 digits) ± (2.0% + 5 digits)
4A ~ 10A 1mA ˜10mA ± (1.8% + 5 digits) ± (2.5% + 10 digits)
Overload Protection:
• uAmA Input: 400mA (F 440mA /1000V fuse)
• A Input: 10A (F 11A / 1000V fuse)
Frequency: 40Hz to 10kHz
Response: True RMS
Resistance Measurement
Range Resolution Accuracy
400Ω~ 4MΩ0.1Ω˜0.001MΩ± (1.0% + 5 digits)
40MΩ0.01MΩ± (1.5% + 10 digits)
Overload Protection: 600V RMS
Capacitance Measurement
Range Resolution Accuracy
40nF 0.01nF ± (3.5% + 6 digits)
400nF ~ 4000µF 0.1nF ˜1µF
Overload Protection: 600V RMS
Frequency Measurement
Range Resolution Accuracy
9.999Hz ~ 999.9kHz 0.001Hz ˜0.1kHz ± (0.1% + 3 digits)
Overload Protection: 600V RMS
Sensitivity: 0.7V RMS
Duty Cycle Measurement
Range Resolution Accuracy
0.1 ~ 99.9% 0.1% ± (0.2% per kHz + 0.1% + 5 digits)
Overload Protection: 600V RMS
Frequency Range: 0.5Hz to 100kHz, pulsewidth >2µsec
Temperature Measurement
Range Resolution Accuracy
-58 ~ 1832°F 0.1 ~ 1°F ± (3.0% + 5.4°F)
-50 ~ 1000°C 0.1 ~ 1°C ± (3.0% + 3.0°C)
Overload Protection: 600V RMS
Thermocouple Accuracy: Not specified