Videcon ANTIVANDAL 10x IP SPEED DOME CAMERA User manual

INSTRUCTION MANUAL Ver 2.1
ANTIVANDAL 10x IP SPEED DOME CAMERA |MPEG4 with Motion Tracking
Firmware Ver. 1.2.1a

ANTI
-VANDAL 10x SPEED DOME CAMERA 2/96
This lightning flash with arrowhead symbol is intended to alert the user to the
presence of un-insulated "dangerous voltage" within the product's enclosure that
may be of sufficient magnitude to constitute a risk of electric shock to persons.
This exclamation point symbol is intended to alert the user to the presence of
important operating and maintenance (servicing) instructions in the literature
accompanying the appliance.

ANTI
-VANDAL 10x SPEED DOME CAMERA 3/96
Important Safeguard
1. Read Instructions
Read all of the safety and operating instructions before using the product.
2. Retain Instructions
Save these instructions for future reference.
3. Attachments / Accessories
Do not use attachments or accessories unless recommended by the appliance manufacturer as they may
cause hazards, damage product and void warranty.
4. Water and Moisture
Do not use this product near water or moisture.
5. Installation
Do not place or mount this product in or on an unstable or improperly supported location. Improperly
installed product may fall, causing serious injury to a child or adult, and damage to the product. Use only
with a mounting device recommended by the manufacturer, or sold with the product. To insure proper
mounting, follow the manufacturer's instructions and use only mounting accessories recommended by
manufacturer.
6. Power source
This product should be operated only from the type of power source indicated on the marking label.
Precautions
Operating
Before using, make sure power supply and others are properly connected.
While operating, if any abnormal condition or malfunction is observed, stop using the camera
immediately and then contact your Special dealer.
Handling
Do not disassemble or tamper with parts inside the camera.
Do not drop or subject the camera to shock and vibration as this can damage camera.
Care must be taken when you clean the clear dome cover. Especially, scratch and dust will ruin your
quality of camera.
Installation and Storage
Do not install the camera in areas of extreme temperature, which exceed the allowable range.
Avoid installing in humid or dusty places.
Avoid installing in places where radiation is present.
Avoid installing in places where there are strong magnetic fields and electric signals.
Avoid installing in places where the camera would be subject to strong vibrations.
Never expose the camera to rain and water.
NOTICE

ANTI
-VANDAL 10x SPEED DOME CAMERA 4/96
○
1Introduction
Features 6
About Network Function 8
Product & Accessories 9
Parts Name & Functions 10
○
2Installation
DIP Switch Setup 12
Installation using Surface mount on the Ceiling 14
Installation using Flush Mount Ring Bracket 15
Installation using Ceiling Mount Bracket 16
Installation using Wall Mount Bracket 17
Cabling 18
○
3Operation
Checking Before Operation 20
Preset and Pattern Function Pre-Check 20
Start OSD Menu 21
Reserved Preset 21
Preset 22
VST 22
Pattern 23
Group 24
Schedule 25
Other Functions 26
OSD Display of Main Screen 27
○
4How to use OSD Menu
General Rules of Menu Operation 28
Main Menu 28
Display Setup 29
Privacy Zone Mask Setup 30
Motion Setup 31
Function Setup 33
Preset Setup 34
VST Setup 36
Pattern Setup 37
Group Setup 38
Schedule Setup 40
Camera Setup 41
System Setup 43
System Initialize 44
C
ONTENTS

ANTI
-VANDAL 10x SPEED DOME CAMERA 5/96
○
5Network Setup
DDNS Registration 45
Quick Start of Network Connection 46
Initial Setup via a Crossover Cable 48
Guide to Network Setup 51
Case A : Dynamic IP or PPPoE + Personal Router 52
Case B : Static(Fixed) IP + Personal Router 54
Case C : Static(Fixed) IP 56
Case D : Dynamic IP + DSL/Cable Modem 58
Case E : PPPoE + DSL Modem 59
Port Forwarding 60
Starting IP Speed Dome 61
○
6Web Viewer
Web Viewer Screen 62
How does Motion Tracking work? 66
Create, Save, Load Map 68
Preset 69
Group 70
Viewer Interface 71
○
7Admin Tool
Video Tool 72
Control Tool 74
Motion Detection Tool 75
Motion Tracking Tool 76
TCP/IP Tool 78
DDNS Tool 79
SMTP Tool 80
Date & Time Tool 81
Users Tool 82
Firmware Update Tool 83
Default Set Tool 84
Rebooting Tool 84
○
8Appendix
A : Current TCP/IP Setting 85
B : Changing your computer’s IP address and subnet mask 86
C : Port Forwarding 87
○
9FAQ 91
○
10 Specifications 95
Specifications 95
Dimension 96
C
ONTENTS

ANTI
-VANDAL 10x SPEED DOME CAMERA 6/96
Features
Network Video Interface
High frame are using hardware MPEG4 compression.
High frame rate with superior Video Quality
High speed : 30 fps at 720 x 480, 25 fps at 720 x 576
Web Browser based Viewer & i-Pro Multi Viewer supported.
Remote control for Pan/Tilt & Sensor I/O.
Bidirectional Audio support
Support with DDNS Service (www.net4c.net) for Dynamic IP
Hardware based Motion Detection function
Hardware based Intelligent Motion Tracking Algorithm (PMI-M200 Only)
Auto Map Generation (PMI-M200 Only)
Virtual Joystick is inspired by real Joystick (PMI-M200 Only)
Camera Specifications
CCD Sensor : 1/4" Interline Transfer CCD
Zoom Magnification : 10 Optical Zoom, 10 Digital Zoom (Max 100 Zoom)
Day & Night Function
Various Focus Mode: Auto-Focus / Manual Focus / Semi-Auto Focus.
Independent & Simultaneous Camera Characteristic Setup in Preset operation
Powerful Pan/Tilt Functions
Max. 360/sec high speed Pan/Tilt Motion
Using Vector Drive Technology, Pan/Tilt motions are accomplished in a shortest path. As a result,
time to target view is reduced dramatically and the video on the monitor is very natural to watch.
For jog operation using a controller, since ultra slow speed 0.05/sec can be reached, it is very easy
to locate camera to desired target view. Additionally it is easy to move camera to a desired position
with zoom-proportional pan/tilt movement.
PTZ(Pan/Tilt/Zoom) Control
With RS-485 communication, max. 255 of cameras can be controlled at the same time.
Pelco-D or Pelco-P protocol can be selected as a control protocol in the current version of firmware.
I
NTRODUCTION
1

ANTI
-VANDAL 10x SPEED DOME CAMERA 7/96
Preset, Pattern,VST, Group, Privacy Mask, Schedule and More…
MAX. 127 Presets are assignable and characteristics of each preset can be set up independently,
such as White Balance, Auto Exposure, Label and so on.
Max. 8 set of VST action can be stored. This enables to move camera repetitively between two
preset positions with designated speed.
Max. 4 of Patterns can be recorded and played back. This enables to move camera to follow any
trajectory operated by joystick as closely as possible.
Max. 8 set of Group action can be stored. This enables to move camera repetitively with
combination of Preset or Pattern or VST. A Group is composed of max. 20 entities of
Preset/Pattern/VSTs.
Privacy Masks are assignable, not to intrude on other’s privacy. (4 Privacy Zones)
7 rules of Schedule can be assigned by day and time. Appropriate actions (such as Home, Preset,
Group, Pattern, VST) can be defined for each rule. Also, it is possible to make rule by Weekday and
weekend to simplify the rule.
OSD(On Screen Display) Menu
OSD menu is provided to display the status of camera and to configure the functions interactively.
The information such as Camera ID, Pan/Tilt/Zoom/Direction, Alarm Input & Output, date/time,
current temperature and Preset can be displayed on screen.
Each display item can be turned on or off independently.
Alarm I/O Functions
2 alarm sensor Inputs and 1 relay output are available.
To reject external electric noise and shock perfectly, alarm sensor Input is decoupled with photo
coupler.
The signal range of sensor input is from DC 5.0 to 12.0 volts to adopt various applications.
If an external sensor is activated, camera can be set to move to the corresponding Preset position.
Relay output can be assigned to work with a certain preset.
Reserved Presets for Special Purpose
Most camera characteristics can be set up easily and directly with reserved preset, not entering
into OSD menu. For more information, refer to “Reserved Preset” in this manual and “Direct Key
Command” Manual.
I
NTRODUCTION
1

ANTI
-VANDAL 10x SPEED DOME CAMERA 8/96
About Network Function
This product is only compatible with current versions of the Microsoft Windows OS.
This product operates with Microsoft’s Internet Explorer only.
You must have ActiveX controls enabled on your browser, found in the Options menu.
Some pop-up blockers may block legitimate configuration screens, please disable these
blockers when configuring the IP Speed Dome.
Some hardware manufacturers include a cable/DSL modem, router/firewall, and Ethernet
switch in one device.
If you have no available ports on your router (with integrated switch) you can purchase a
10/100 Ethernet switch to “expand” your Local Area Network
The crossover cable is not wired as a typical straight-through network cable. This cable (or
any crossover) should be used for initial setup of the IP Speed Dome via a PC/laptop.
Please temporarily disconnect any proxy servers associated with Internet Explorer while
configuring the IP Speed Dome.
Modification and Development
The Linux-based operating system and flash memory file system enable advanced users and
application developers to customize the IP Speed Dome. An SDK developer kit is available for
users to interface ActiveX controls and other applications.
Attempts to modify the IP Speed Dome will void all warranties and will not be supported by
manufacturer or its seller. Further development tools and documentation for assistance may be
accessible in future releases. We strongly recommend that inexperienced users DO NOT modify
the firmware of IP Speed Dome.
The manufacturer or its seller will not be held accountable in a user's attempt to modify the IP
Speed Dome that renders the unit inoperable or otherwise.
This document is for Network firmware version 1.2.1a
1
I
NTRODUCTION

ANTI
-VANDAL 10x SPEED DOME CAMERA 9/96
Product & Accessories
Product & Accessories
Main Body Surface Mount Bracket
Screws & Terminal Block Crossover Cable
Options
Ceiling Mount Bracket Wall Mount Bracket
Flush Mount Ring Bracket
I
NT
RODUCTION
1

ANTI
-VANDAL 10x SPEED DOME CAMERA 10/96
Parts Name & Functions
Main Unit / Surface Mount Bracket Back of Main Unit
Dome Cover Do not detach protection vinyl from dome cover before finishing all
installation process to protect dome cover from scratches or dust.
Surface Mount Bracket This is used to install the camera directly on the ceiling. After
separating this cover first and then attach this directly to ceiling.
Camera must be assembled at the last stage.
Do not use this bracket when installing camera on the wall with wall
mount bracket or on the ceiling with ceiling mount bracket.
Lockup Screw Fixes main unit to surface mount bracket.
Cabling Terminal Block During installation, Power, Video, Communication, Alarm Input cables
are connected on to this cabling terminal block.
DIP Switch Adjusts camera ID and protocols.
Ethernet Connector This RJ-45 connector is for network connection and designed to operate
on 10 or 100 Mbps.
Reset Switch Return all settings to their factory defaults. Care must be taken since
you will lose all data made previously.
ACTIVE LED When in use, this Yellow indicator should always be flashing or
flickering. During reboots or power cycling, it may take several
seconds for the unit to initialize and illuminate the indicator.
I
NTRODUCTION
1

ANTI
-VANDAL 10x SPEED DOME CAMERA 11/96
LINK LED This green indicator should be flashing or glowing during normal
operation. During a reboot or power cycling, it may take up to 50
seconds to initialize, negotiate your network speed, and begin
operation at 10 or 100Mbps. If this light is not lit after 50 seconds of
operation, check the network cable to ensure a proper connection.
When a proper connection is met, the green indicator should
immediately glow.
1
I
NTRODUCTION

ANTI
-VANDAL 10x SPEED DOME CAMERA 12/96
DIP Switch Setup
Before you install the camera, you should set the DIP switches to configure the camera ID, communication
protocol.
Camera ID Setup
1 2 3 4 5 6
ON
ON
7 8
ID number of camera is set using binary number. The example is
shown bellow.
Pin 12345678
ID Value 1 2 4 8 16 32 64 128
ex) ID=5 on off on off off off off off
ex) ID=10 off on off on off off off off
The range of ID is 1~255. Do not use 0 as camera ID. Factory
default of Camera ID is 1.
If you want to control a certain camera, you must match the camera
ID with Cam ID setting of DVR or Controller.
I
NSTALLATION
2

ANTI
-VANDAL 10x SPEED DOME CAMERA 13/96
Communication Protocol Setup
1 2 3 4
ON
ON
Reserved for Supplier
RS-485 Termination Resistor
Select the appropriate Protocol with DIP switch combination.
Switch State
P0
(Pin 1)
P1
(Pin 2)
Protocol
OFF OFF PELCO-D, 2400 bps
ON OFF PELCO-D, 9600 bps
OFF ON PELCO-P, 4800 bps
ON ON PELCO-P, 9600 bps
If you want to control using DVR or P/T controller, their protocol must
be identical to camera. Otherwise, you can not control the camera.
If you changed camera protocol by changing DIP S/W, the change
will be effective after you reboot the camera.
Factory default of protocol is “Pelco-D, 2400 bps”.
Since Pin 3 is only for supplier, DO NOT CHANGE THESE ITS
ORIGINAL STATE.If you change one of these, proper operation can
not be achieved.
Pin 3 PAL / NTSC system selection of Camera. DO NOT
CHANGE THIS PIN.
I
NSTALLATION
2
Pin 4 is used for ON/OFF of RS-485 Termination. Normally, it must be
OFF state. Especially when you have trouble with long Daisy chain
style connection, turn ON this termination switch of last camera.
Pin 4 RS-485 Termination Resistor (On/Off)

ANTI
-VANDAL 10x SPEED DOME CAMERA 14/96
Installation using Surface mount on the Ceiling
①To pass cables to upside of ceiling, please, make
about φ60mm hole on the ceiling panel.
②Screw surface mount bracket to ceiling with 4
screws.
③Wire cables to terminal block and connect the
terminal blocks to main unit.
④Screw main unit to surface mount bracket with 4
lock-up screws.
⑤Detach protection vinyl from dome cover.
I
NSTALLATION
2

ANTI
-VANDAL 10x SPEED DOME CAMERA 15/96
Installation using Flush Mount Ring Bracket
①To pass cables to upside of ceiling, please, make
about φ170mm hole on the ceiling panel.
②Screw surface mount bracket to ceiling with 4
screws.
③Wire cables to terminal block and connect the
terminal blocks to main unit. Screw main unit to
surface mount bracket with 4 lock-up screws.
④Detach protection vinyl from dome cover.
I
NSTALLATION
2

ANTI
-VANDAL 10x SPEED DOME CAMERA 16/96
Installation using Ceiling Mount Bracket
①Screw ceiling mount bracket to ceiling with 3
screws.
②Wire cables to terminals and connect the
terminals to main unit. Do not use surface mount
bracket!
③Screw main unit to ceiling mount bracket with 4
screws.
④Detach protection vinyl from dome cover.
I
NSTALLATION
2

ANTI
-VANDAL 10x SPEED DOME CAMERA 17/96
Installation using Wall Mount Bracket
①Screw wall mount bracket to ceiling with 3
screws.
②Wire cables to terminals and connect the
terminals to main unit. Do not use surface mount
bracket!
③Screw main unit to wall mount bracket with 4
screws.
④Detach protection vinyl from dome cove.
I
NSTALLATION
2

ANTI
-VANDAL 10x SPEED DOME CAMERA 18/96
Cabling
Power Connection
Please, check the voltage and current capacity of rated power carefully. Rated power is indicated in the
back of main unit.
Rated Power Input Voltage Range Current Consumption
DC 12V DC 11V ~ 18V 0.8 A
RS-485 Communication
For PTZ control, connect this line to keyboard and DVR. To control multiple cameras at the same time,
RS-485 communication lines of them is connected in parallel as shown below.
Video Connection
Connect with BNC coaxial cable.
I
NSTALLATION
2

ANTI
-VANDAL 10x SPEED DOME CAMERA 19/96
Ethernet Connection
Connect with RJ-45 cable.
Alarm Input Connection
Sensor Input
Before connecting sensors, check driving voltage and output signal type of the sensor. Since output
signal types of the sensors are divided into Open Collector and Voltage Output type in general, the
cabling must be done properly after considering these typed.
Signal Description
IN COM+ Connect (+) cable of electric power source for Sensors to this port as
shown in the circuit above.
IN1, IN2Connect output of sensors for each port as shown in the circuit above.
If you want to use Alarm Input, the types of sensor must be selected in OSD menu. The sensor types are
Normal Open and Normal. If sensor type is not selected properly, the alarm can be activated reversely.
Normal Open Output Voltage is high state when sensor is activated
Normal Close Output Voltage is high state when sensor is not activated
Relay Output
I
NSTALLATION
2

ANTI
-VANDAL 10x SPEED DOME CAMERA 20/96
Check points before operation
Before power is applied, please check the cables carefully.
The camera ID of the controller must be identical to that of the target camera. The camera ID can be checked
by reading DIP switch of the camera.
If your controller supports multi-protocols, the protocol must be changed to match to that of the camera.
If you changed camera protocol by changing DIP switch, the change will be effective after you reboot the
camera.
Since the operation method can be different for each controller available, refer to the manual for your
controller if camera can not be controlled properly. The operation of this manual is based on the standard
Pelco® Controller.
Preset and Pattern Function Pre-Check
Check how to operate preset and pattern function with controller or DVR in advance to operate camera
function fully when using controller or DVR.
Refer to the following table when using standard Pelco® protocol controller.
< Go Preset > Input [Preset Number] and press [Preset] button shortly.
< Set Preset > Input [Preset Number] and press [Preset] button for more than 2 seconds.
< Run Pattern > Input [Pattern Number] and press [Pattern] button shortly.
< Set Pattern > Input [Pattern Number] and press [Pattern] button for more than 2 seconds.
If controller or DVR has no pattern button or function, use shortcut keys with preset numbers. For more
information, refer to “Reserved Preset”in this manual.
OPERATION
3
This manual suits for next models
1
Table of contents
Other Videcon Security Camera manuals