3.Internalwiringinstructions
OUTX(WhiteWire):Theoutputoftherelayisconnectedwiththe
electromagneticswitch,usedtocontrolthedoor.
PJ1(RedandBlackWires):Externalpowersupply,theuseof
9‐24VDC,payattentiontodistinguishbetweenpositiveand
negative(RedWire:Positive,BlackWire:Negative).
RST:Reset,jumperwireconnection,andthenboot,after10
seconds,disconnect,Restorefactorysettings(resetdoesnotclear
user’snumberinformation).
J4(YellowWire):Connecttodoorswitch.
4.Setupandoperation
ThisdeviceissetupandoperatedbySMS.Allofthefollowinglettersareuppercaseletters.Passwordfactory
defaultis1234,"+"isnotthemessagecontent,Suchasequipmenttimecommand:1234TEL13812345678#.Each
instructionwillreceivethecorrespondinginformationoractionofthefeedbackfromthedevice.Ifyoudonot
receivefeedback,indicatethatthedevicedidnotreceivetheinstruction,pleasecheckwhetherthecardis
insertedandthecardisvalid.
◆ Theequipmenttimecalibration
Password+TEL+equipmentnumber#
Forthefirsttimeorwhenyouwanttochangeyourphonecard.
◆ Modifythepassword
Currentpassword+P+newpassword
◆ Settheusernumber
Password+A+serialnumber#+userphonenumber# or
Password+A+serialnumber#+userphonenumber#+starttime#+endtime#
Serialnumber:001~200;
Starttime,Endtime:Inthisperiodoftime,itcanbecalledintocontroltherelay,TheFormat:1701020304
(indicate:January2,20173hours4minutes).Donotsetthetimetoindicatepermanentauthorization.
◆ Deleteusernumber
Password+A+serialnumber##