Vido.at AU-G65-SC18 User manual

G65
G70
USER'S MANUAL
v2.58
High Speed Dome
Camera Series

CONTENTS
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN
OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR
OTHER OPENINGS ON THE EQUIPMENT.
FCC COMPLIANCE STATEMENT
CE COMPLIANCE STATEMENT
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS‘S AUTHORITY TO OPERATE THE
EQUIPMENT.
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE
LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE
LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL
INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS
EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT
INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL
INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A
RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER
WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS
PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE
REQUIRED TO TAKE ADEQUATE MEASURES.
CAUTION: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER ( OR BACK). NO
USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO
QUALIFIED SERVICE
PERSONNEL
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature
accompanying this unit.
WARNING
CAUTION: BEFORE ATTEMPTING TO CONNECT OR OPERATE THIS PRODUCT, PLEASE
READ THE LABEL ON THE BOTTOM AND USER'S MANUAL CAREFULLY
1. Precaution...................................................... 1
2. Features......................................................... 2
3. Packing list..................................................... 3
4. Installation...................................................... 4
5. Operation........................................................ 10
6. OSD................................................................ 11
7. Adress and Protocol Setting.............................., 19
8. Specifications.................................................. 23
Technical specification are subjects to change without
prior notice. Manual may contain mistake or print error.
All trademarks mentioned belong to their respective owners.
ENGLISH

1.PRECAUTION
Refer all work related to the installaion of this product to qualified service
personnel or system installers.
Do not attemp to disassemble the appliance
Handle the appliance with Care
Do not use strong or abrasive detergents when cleaning the appliance body and
transparent cover.
Do not operate the apliance beyond its specified temperature, humidity or power
source ratings.
indoor models
Do not point the camera lens directly to sunlight or any strong light source.
Read this user's manual carefully before operating the appliance.
Do not install the camera in other orientation as designed.
Do not touch the Cover with bare hands or any object.
To prevent electric shock, do not remove screws or cover. There are no user-
serviceable parts inside. Contact qualified service personnel for maintenance
Do not strike or shake, as this may damage the appliance. It should be protected
against extreme pressure, vibration and humidity during transportation and storage.
Damages caused by improper transportation avoid the warranty.
Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove,
use a mild detergent and wipe gently.
Do not use the dome camera in an extreme environment where high temperature or
high humidity exists.
Use the within -10°C to +50°C(14°F to 122°F) and a humidity below
90%. The input power source is 24V AC, 50/60Hz and requires 1000mA.
Take immediate action when the indoor speed dome becomes wet. Turn off the power
and refer servicing to qulified service personnel. Moisture may damage the appliance
and cause eletric shock.
This will cause permanent damage to the camera and avoids the warranty.
Make sure that local electric safty standard are followed when using or installing the
appliance
And do not bend or squeez the sturctiure, as this may damage the mechanic sturcture
of the appliance and avoids the warranty.
These will scratch the serface and affect the image qulaity.
Use the within -20°C to +60°C(-4°F to 140°F) and a humidity below
90%. The input power source is 24V AC, 50/60Hz and requires 2500mA.
outdoor models
Do not expose the indoor model of dome camera to water or moisture, not try to
operate it in wet areas.
2.FEATURES
The G65 and G70 high speed dome camera series are designed for in- and outdoor video
surveillance application. The integrated, motorized pan-tilt mechanic allows user to point
the camera to any position( 360° horizontal and 180° vertical). Both series can be
equipped with digital zoom camera modules, which provide zooming functon from 18 to
36 times (optical) and advanced image features.
- 360° Pan and 180° Tilt range (90° with auto-image-flip)
- Support most well-known camera modules
- 128 preset points memory (80 can be used for auto tour function)
- 4 pattern tours
-1Scantour
- Basic setup directly from Keyboard.
- Advanced setup through OSD (On Screen Display) menu.
- up to 24 privacy masking zones ( despends on camera module)
- 7 alarm input & 2 output(4input&1outputpre-wired)
- Multi-Protocol through Rs485 or coaxial cable.
- Dirction Indicator on screen
- Aluminum Alloy structure with high intensity and heat-sinking
- High-precision step-motor for flicker-less image during movement.
-HighResolution with 520TVL and Wide-Dynamic*
- Auto-Focus
- Auto-Iris
- Auto- Brightness control,
- Auto-Balance
- IR cutter control, Day-Night mode switching.
- Auto Slow-Shutter
depends on camera module type.
Key features:
Camera Features:
*
Temperature monitoring and protection
Other features:
- Alarm notification will be displayed once the inner temperature exceeds the limit
- In low temperature area, the dome camera will only start after the operation
temperature is reached.
- Cooling fan activity is managed by the CPU ( extends the duration)
- Proportional pan for Focus / Speed on different zoom factor.
- Auto-resuming user-defined action, such as tour, pattern or scan after selectable idle
time.
- Power-up Action activates tour or pattern by default.
12
ENGLISH

3.PACKING LIST
Safety Instructions before starting
- Do not install and operate this appliance in a flammable and explosive environment.
- Make sure that the installation is done according to the local electricity safety regulation
of your country.
.
- Before installation and mentainence, make sure that the appliance is disconnected
from the power source.
- Do not use any power source other than 24V AC, in order to prevent damages to this
device. For details, please refer to the section "Precaution" in previous chapter for
more details.
- Handle the device during the installation carfully. Falls or extreme vibration may cause
irrepairable damages and avoid the warranty.
- Do not install or operate the appliance near any high-voltage devices or high-voltage
cable. The safety distance should remain at least 50 m.
- To archive best image quality, its recommanded to use underground cable shielded with
steel tube. Do not install the cable without any protection.
- In a thunderstorm area or region with high inductive voltage, such as high voltage
transformer stations, it is necessary to use additional lighning-proof equipments or
lightning rob for protection.
- For outdoor installation, lightning-proof and grounding of the device should be
considered. Please refer to the industrial saftey regulation and request of your country
.
- Grounding of the appliance should consider anti-interference and fulfill the saftey
requirements. Do not connect the ground with short-circuited or other high-voltage
electric network.
- The resistance of down conductor should not exceed 4 Ohm, and its thickness should
be at least 25mm²
- This appliance has the lightning-proof function which can prevent damages caused by
high-voltage pulse, such as lightning strike below 1500.
- This appliance meets the Ip66 standard for water and dust proof. Do not install the in-
door model for out-door application which is not designed with water protection. Make
sure that the installation is protected from long-time water-drop or spatter, which may
damage the appliance.
- Make sure that the enviroment of installation meets the requirement of the appliance,
such as holding the weight, enough spaces for bracket and power supply.
4.INSTALLATION
G65-S
AU-G65
AU-G70
USER'S MANUAL
www.vido-europe.com
High Speed dome
Camera Series
G65-S
Core Unit
1 Piece
Indoor Roof-Mount
base platte
1 piece
Instruction and
operation manual
1 piece
G65-W
G65
Core Unit
1 Piece
Out-Door housing
with sun.shield and
cover
1 piece
AU-G65
AU-G70
USER'S MANUAL
www.vido-europe.com
High Speed dome
Camera Series
Instruction and
operation manual
1 piece
Spare dome cover
1 piece
G70-W
G70
Core Unit
1 Piece
Out-Door housing
with sun.shield and
cover
1 piece
AU-G65
AU-G70
USER'S MANUAL
www.vido-europe.com
High Speed dome
Camera Series
Instruction and
operation manual
1 piece
Spare dome cover
1 piece
Some models may not be available in your country, please contact VIDO distributor for more details
Unpacking
The speed dome is packed with protection. please take
out the core unit carefully. In case of transportation
please use the original packing box.
WARNING: The transparent cover part is sensitive and should
be handled with care. Do not touch or rub the surface in any way
with the protection foil.Inproper cleaning method will cause
permanent scratches on the cover and cause unclear image or
focusing error of the camera. For Cleaning the cover, please
replace the original first with the spare cover, and wash it by
diving into warm water with non-corrosive cleaning solution.
34
ENGLISH

4.INSTALLATION
Connector description
The wiring cable of G65 and G70 provides connectors for power supply, video and I/O
interface
Power
Connector
RS 485
Connector
RJ-11
Video output
BNC
Alarm I/O
RED : AC 24V
BLACK : AC 24V
To power supply
YELLOW : RS485 -
GREEN :RS485+
To keyboard or DVR devices for
telemetric control
RED : Alarm in 1
PINK : Alarm in 2
YELLOW :
GREEN :
BLACK : COM
WHITE : Alarm output - N.O
BLUE : Alarm output - N.C
AQUA
Alarm in 3
Alarm in 4
:
I/O interface to additional alarm
Alarm output - N.C2
BROWN : Alarm output - N.O2
GRAY : Alarm in 7
PURPLE : Alarm in 6
ORANGE : Alarm in 5
Inner Conn : Signal +
Outer Conn : Ground
Video Output to monitor or DVR
Using optional accessories
The G65 and G70 speed dome cameras can be connected to various optional
accessories through the standard connector types, which simplifiy the cable handling
and avoids possible mistakes. All accessories are tested for max. compatibility and
best performance.
AU-WP20
Outdoor power adaptor box
AC 230V to AC 24V
AC 24 Power
supply
RS 485
Alarm I/O
AC 230V
Power input
AU-S20
Indoor power adaptor
AC 230V to AC 24V
AU-
S20
AC 230V
Power input
AC 24 Power supply
AU-KB3N
3-Axis keyboard
controller
RS 485
Telemetric control
camera setup
AU-JD2028
21”High Res.
security Monitor.
AU-DVRH-16/400
Professional Real-time
16 Channel DVR
Video signal
RS 485 cable
The telemetric control of the appliance uses Rs485 serial communication with half-
duplex transmission technology.
Depends on the cable typeand baud rate, the transmission distance could vary. The
following table shows max. distances based on cable with 0,56mm (24AWG) twisted
pair:
2400 bps
1100 m
700m
4oom
4800 bps
1700m
9600 bps
19200 bps
Baud Rate Max. Distance
Due the environmental interferences, such as
eletromagnetic and induction fields, or number of
connected appliance on the RS-485 bus, the
transmission range may be less, e.g with cable thinner
than than 24AWG.
4.INSTALLATION
56
ENGLISH
KB3N
Alarm I/O

4.INSTALLATION
4.INSTALLATION
Video Cable
coaxial cable with 75 impedance with copper conductor at center conductor, and
shielded with 95% copper. The following table shows different cable type and its
maximum length:
Ω
The values are for reference only.
Depends on the cable quality and
environmental condition, the
transmission distance might be less.
RG6/U
Cable standard
RG 11 /U
229m / 750 ft
Max. Distance (m /ft )
305m/ 1000 ft
457m / 1500 ft
RG 59 /U
If the cable length is more than 400 m, it is recommended to use optional
accessories, such as video amlifier(e.g AU-VD-1001) or twisted-pair video
converter (e.g. AU-TP02 or AU-TP08), for boost the video signal.
AU-VD1001
Video Amplifier
(optional)
AU-DVRN16/400
Real time DVR Center
(optional)
AU-JD2102
High Res Monitor
(optional)
G65 Series
G70 Series
Up to 750m, coaxial cable
Extend connection distance with
video amplifier
AU-TP08
TP receiver
(optional)
AU-DVRN16/400
Real time DVR Center
(optional)
AU-JD2102
High Res Monitor
(optional)
G65 Series
G70 Series
Up to 1200m, twisted pair or cat.5 cable
Extend connection distance with Twisted-Pair
video converter
AU-TP02 or
AU-TP08 transmitter
(optional)
G65 and G70 series domes provide integrated termination switch. It should be
turned on when the dome is installed as the last device. If the controller keyboard
is used such as AU-KB3A, you need also to turn on the termination on it. please
refer to the keyboard’s manual for details.
RS-485Termination
Devices using Rs485 control are usually connected in daisy-chain. which reqiuers
termination with 120 resistor on both ends. Following picture illustrates the
connection methods. please note that a daisy-chain connection type shall not
exceed 7 meters.
Ω
120
Ω
Resistor
Device 2 Device 3Device 1
120
Ω
Resistor
RS 485+
RS 485-
RS 485+
RS 485-
Termination
on
Termination
off
Termination
off
HowtoturnonterminationonG65andG70
The termination switch is located on the rear side of the connection board. For
switching on, you need to open the
Star-Connection
The star-form connection is mostly used. it enables the connection of different dome
cameras in longer distance. It is recommended to use RS-485 distributor (e.g AU-VC-
MC2088) to ensure the telemetric data transmission:
The advantage of star-connection is
that every channel can work
independently and take a cable
length up to 1000 meters( depends
on cable quality). In case more
dome camera are installed, the star-
connection can be extended with
additional RS-485 distributors.
Some products may not be available in your country, please contact our distributor for more details
123
Term. Off ( default)
Term. On
123
ON ON OFF
OFF ON ON
Jumper
Termination
Jumper
rear side
How to open the connector board
The connector board can be easily
opened by holding the metal clip and
pull.
Press the metal
clip in and pull
the board on this
direction.
Metal
Clip holder
Some products may not be available in your country, please contact our distributor for more details
78
ENGLISH
Termination on
AU-KB3N
KB3N
Termination on
AU-KB3N
AU-MC2088
RS-485
Distributor
RS-485 cable
up to 1000m
per channel
Termination
activated on
every end.
KB3N

5.OPERATING THE SPEED DOME
FIRMWARE V2.58
Protocol: VIDO B02
Dome Address: 001
Comm 9600,N,8,1
Initial Screen
After powering up, the camera will enter the
self-test mode and display the status screen(
as in the picture left).It contains information
about the model and current settings.
- V2.58:
- Protocol:
- Dome address:
- Comm 9600,N,8,1:
Current firmware version
control protocol which currently used
Address ID of speed dome. please refer to the section "Protocol
setup " for details.
current setting of the serial communication interface.
Baud rate. please refer to section "Baud-Rate setup" for details
No parity bit, 8 bit length, 1 stop bit. this setting can not be changed
9600:
N, 8, 1:
Operation Screen
The intial screen will stay remain on until any user action is being taken. If the power-
up action is set, the initial info wil vanish immediatly.
32.0CAM TITLE
ZONE-1
285 78 18X
Pan degree
Zoom factor
Tilt degree
Zone description
Temperature
4.INSTALLATION
Optional bracket accessories
The G65 and G70 Series can be equipped with various bracket accessories for indoor
and outdoor installation. please contact your distributor for further details.
Corner
Mount
Pole
Mount
Wall mount and
Power box
Ceilling
mount
Indoor Wall
mount
Outdoor
Power Box
Indoor ceilling
mount
Extended wall
mount
Swan-Neck
Mounting
bracket
Wall
mount
Installing the core unit to base board.
The G65 and G70 Series core unit and base board are packed seperatly, in order to be
protected through the transportation. After unpaking and during the installation, the
core unit should be installed as following:
Installing the core unit by
pushing into the
housing.please note the
position of connector. For
releasing, please press the
lever-lock to core and pull off
the unit. Lever-
Lock
Connector
Interface
Power
LED
Metal
Clip
WARNING:
Do not pull or hold the connector interface with force. It
is design only to connect the core unit and the base
board. Any presure on connector will cause damage and
avoids the warranty.
PTZ operation
For the surveillance operation, the dome can be controlled from a keyboard device
(e.g. AU-KB3N), Multiplexer or DVR through RS-485 Interface. Make sure that the
cable is connected and the settings (baud rate, Address ID and protocol) of both
keyboard and the dome are configured correctly. For more description about the PTZ
operation, please refer to the user’s manual of the keyboard.
Safety spring
Rubber ring
cable Heater connector
Once the base board is connected to power,
the power LED will light.
Heater connector
on outdoor
housing
Outdoor
housing cover
Screws
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
910
Indoor
embedded
mount
ENGLISH
The operation screen can display additional
information.
Temperature: current temperature inside the
speed dome( °C)
Cam title: User definable camera title
Zone: Current zone name
Pan deg.: Pan angle, 0-359°
Tilt deg.: Tilt angle, 0-90°
Zoom Factor: Zoom factor
Display of the information can be activate or
deactivate through the OSD menu. please refer to
the system setting for detais.

OSD
OSD Menu
How to start the OSD menu
The G65-70 Series are equipped with new OSD-Menu function. All operation functions and
camera related settings can be changed or modified here. In order to use the OSD function,
a telemetric controller device, such as Keyboard, DVR or other devices with similiar function
is necessarily required. please make sure that the device used is physically connected to the
dome properly, and all connection parameters are set correctly.
To start the OSD Menu, you need to press following key on the keyboard:
With AU-KB2A or
With AU-KB3N or
In case a DVR is used for the OSD, select “goto preset 95” or 2 X “goto preset 9”. Please
refer to the DVR’s operation manual for more details.
Note that in some certain situations, it is not possible to enter the OSD menu:
1. the dome is running tour
2. performing PTZ operation
3. dome is receiving command other than OSD-request from the keyboard.
please stop the operation and try again.
2X
2X
Shot 9 5 Enter
Main menu and navigation
Main Menu
SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
ALARM
EXIT
After entering the OSD Menu, the screen will show menu
items . Use the controller’ joystick to navigate through the
menu’s main and sub items by moving in the direction.
The angle mark on the beginning of every items indicates
the selection.
UP, DOWN: - Moving between current menu items
- Changing the value in subitems
RIGHT: - Enter the selected menu item
- Confirm the value change and return to
item selection
LEFT: Exit from sub menu
For more inforamtion, please refer to the illustration on
the next page for the OSD menu structure.
OSD-MAP
Symbols and indicator
Cursor.
Sub item is selected. use up or down to change value
This item has subitem(s)
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
call 9 5 Enter call 9Enter
Shot 9Enter
ENGLISH
MAIN MENU
SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
EXIT
→
→
→
→
→ALARMS
SYSTEM SETTING
EDIT DOME LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
BACK
EXIT
→
→
→
→
→
→PASSWORD SETUP
CLOCK SETTING
CAMERA SETTING
ZOOM SPEED HIGH
DIGITAL ZOOM ON
BLC MODE OFF
SLOW SHUTTER ON
WDR MODE
ADVANCE SETTING
LINE SYNC N/A
N/A
1→
BACK
EXIT
ADVANCE SETTING 2
→
FUNCTION SETTING
IR CUTTER FILTER AUTO
IR CUT ON TIME N/A
IR CUTOFF TIME N/A
MAX GAIN 28dB
BACK
EXIT
PRESETS
SCAN
SCAN NUMBER 01
SCAN SPEED 63
SET LEFT LIMIT
SET RIGHT LIMIT
CLEAR SCAN
RUN SCAN
EDIT SCAN LABEL
BACK
EXIT
→
PATTERNS
PATTERN NUMBER 1
PROGRAM PATTERN
RUN PATTERN
CLEAR PATTERN
EDIT PATTERN LABEL
BACK
EXI
→
T
EDIT TOUR
٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠
٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠
٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠
٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠
٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠
P0-S- P0-S- P0-S-
-00
-00
-00
-00
-00
TM TM TM
BACK
EXIT
ZONES
ZONES NUMBER 1
SET LEFT LIMIT
SET RIGHT LIMIT
CLEAR ZONE
EDIT ZONE LABEL
BACK
EXIT
→
DOME LABEL OFF
PRESET LABEL OFF
ZOOM LABEL O
ZONE LABEL OFF
DIRECTION LABEL O
TEMPERATURE LABEL OFF
BACK
EXIT
FF
FF
TIME LABEL OFF
DATE LABEL OFF
MOTION
AUTO FLIP ON
PROPORTION PAN ON
PARK TIME 005
PARK ACTION
POWER UP ACTION
FAN ENABLED 040
BACK
EXIT
NONE
NONE
TEMP C/F CENT
ADVANVE SETTING →
PASSWORD SETUP
INITIAL INFO
SPEED DOME V
PROTOCOL :
DOME ADDRESS: 001
COMM: 00 . N.8.1
BACK
EXIT
2.58
96
VIDO B02
PRESET NUMBER 001
SET PRESET
SHOW PRESET
CLEAR PRESET
EDIT PRESET LABEL
BACK
EXIT
→
LABEL: PRESET-01
BACK
EXIT
EDIT PRESET LABEL
LABEL: AUTO SCAN
BACK
EXIT
EDIT SCAN LABEL
LABEL: PATTERN-1
BACK
EXIT
EDIT PATTERN LABEL
LABEL: ZONE-1
BACK
EXIT
EDIT ZONE LABEL
LABEL:SPEED DOME
BACK
EXIT
1.00
EDIT DOME LABEL
DISPLAY SETUP
ADVANCE SETTING 1
PRESETS
SCAN
PATTERNS
TOUR
ZONES
TIME RUNNING
AUTO-TRACKING
→
→
→
→
→
BACK
→
EXIT
OLD PASSWORD : ******
NEW PASSWORD : ******
CONF PASSWORD : ******
ENABLE PASSWORD OFF
BACK
EXIT
CLEAR ALL ZONES
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL TOURS
CLEAR ALL WINDOWS
FACTORY DEFAULTS
RESTART
BACK
EXIT
TOUR
TOUR →
RUN TOUR
BACK
EXIT
NUMBER 1
EDIT TOUR
CLEAR TOUR
WINDOW NUMBER 01
EDIT WINDOW
ENABLE WINDOW ON
CLEAR WINDOW
BACK
EXIT
WINDOW BLANKING
ALARM NUMBER 001
ALARN ACTION NONE
ACTIVATE AUX NONE
ALARM PRIORITY
BACK
EXIT
ALARMS
RESUME OFF
RESET DELEY 030
ALARM CONTACT N/O
ALARM SETTING
ARM SETTING
BACK
EXIT
→
→
ADVANCE SETTING
EIS ENABLED N/A
ESET FREEZE FF
DEFOGGER 015C
PR N O
BACK
EXIT
CLEAR
CLOCK SETTING
TIME 00:00:00
DATE 01/01/01
DAY MON
BACK
EXIT
AE MODE AUTO
SHUTTER N/A
IRIS N/A
BRIGHT N/A
W MODE AUTO
R GAIN N/A
B GAIN N/A
BACK
EXIT
B
HI-RESOLUION N/A
ADVANCE SETTING 2
TIME RUNNING
DAY SUN
TIME CHANNEL 1
START TIME 00:00
RUNNING NONE
BACK
EXIT
AUTO-TRACKING
DAY SUN
STATE ON
START TIME N/A
END TIME N/A
SENSITIVE LOW
TRACKING-ZOOM OFF
SET LEFT LIMIT
SET RIGHT LIMIT
BACK
EXIT
→
→
DAY SUN
ARM STATE OFF
ARM TIME N/A
UNARM TIME N/A
BACK
EXIT
ARM SETTING
ALARMS SETTING

System Setting
In system setting menu, you can modify operation and
display setting, such as dome label, temperature and
display of various value on the operational screen.
EDIT DOME LABEL
LABEL
BACK
EXIT
:
ENTRANCE
INITIAL INFO
SPEED DOME V1.00
PROTOCOL:FACTORY
DOME ADDRESS:001
COMM:4800,N,8,1
BACK
EXIT
6.OSD - System Setting 6.OSD - Motion, Clear
Initial information:
Shows the information about current setting.
Dome Label:
1. use UP or DOWN to change the charactor.
2. use RIGHT to move to next char.
3. use RIGHT to move to last char and save.
4. use Left to first char and cancel.
Display setup
Dome label:
Preset label:
Zoom label:
Zone label:
Direction label:
Temperature label:
Actuvate the display for the on-screen info in
operaton mode.
the name of dome
shows the labe of every preset
shows zoom factor on screen
shows the zone name
shows the coordinates
shows the cur. temp in the speed dome
DISPLAY SETUP
DOME LABEL OFF
PRESET LABEL OFF
ZOOM LABEL ON
ZONE LABEL OFF
DIRECTION LABEL ON
LABEL OFF
BACK
EXIT
TEMPRATURE
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
13 14
ENGLISH
SYSTEM SETTING
EDIT DOME LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
PASSWORD SETUP
CLOCK SETTING
BACK
EXIT
MOTION Motion control
AUTO FLIP
PROPORTIONAL PAN:
PARK TIME:
: Auto. Image flip in tilt range from 90° to
180°
depends on the zoom factor,
the dome will adjust the pan and tilt speed
automatically for comfortable viewing.
defines the idle time prior to start a
custom defined action( park action).The range is
from 1 to 240 minutes. This function can be
deactivated by setting the minute to 0.
PARK ACTION:
POWER UP ACTION:
the action which will be started after
the idle time (park time). Selectable between Preset,
Scan, Pattern (Nr), Tour or None.
defines the action which will
be started after power up and self test. Selectable
between Auto,Preset 1, Scan, Pattern (Nr), Tour or
None. By selecting Auto, the dome will resume the
last action before power off.
AUTO FLIP ON
PROPORTION PAN ON
PARK TIME 005
PARK ACTION SCAN
POWER UP ACTION AUTO
BACK
EXIT
Clear
You can clear setting’s memory or reset the
camear to factory default. The follwing functions
are supported:
- Clear Zones
- Clear all presets
- Clear all patterns
-Clearalltours
-Clearallwindows
- Factory defaults
Warning:The clear action can not be
undone. once a item is cleared it is
impossible to retrieve the deleted setting.
Please make sure that the requested clear
action is desired.
CLEAR
CLEAR ALL ZONES
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL TOURS
CLEAR ALL WINDOWS
FACTORY DEFAULTS
RESTART
BACK
EXIT
O
NEW PASSWORD : ******
ENABLE PASSWORD OFF
BACK
EXIT
LD PASSWORD : ******
CONF PASSWORD : ******
PASSWORD SETUP
Password setup
You can change password to access the OSD menu.
Default Password is 000000.
TIME ´00:00:00
DATE 01/01/01
DAY MON
BACK
EXIT
CLOCK SETTING Clock setting
Some function like Auto-Tracking require the timer for
activation.
Time: HH:MM:SS
DATE: YY/MM/DD
DAY: MON-SUN

Camera setting
ZOOM SPEED:
DIGITAL ZOOM:
BLC MODE:
SLOW SHUTTER:
WDR:
In camera setting menu, you can setup camera module
related settings. please note that depends on module’s
capability, some function may not available. please contact
your local sales representative for detailed information.
defines the speed when performing zoom
function.
Activate or deactivate the digital zoom
function of the camera module.
Select the Back Light Compensation mode,
improves the image when an object has strong back light.
Activates the Slow Shutter function of the
camera, which provides a higher light sensibility in low-
environment.
Activates the Wide Dynamic Range function, which
improves the image contrast when an object has very strong
light on background. Only available with camera modules
with WDR.
OSD - Camera Setting OSD - Preset, Scan
CAMERA SETTING
ZOOM SPEED HIGH
DIGITAL ZOOM ON
BLC MODE OFF
SLOW SHUTTER ON
LINE SYNC N/A
WDR MODE N/A
ADVANCE SETTING 1
ADVANCE SETTING 2
BACK
EXIT
ADVANCE SETTING 2
AE MODE AUTO
SHUTTER N/A
IRIS N/A
BRIGHT N/A
WB MODE AUTO
RGAIN N/A
BGAIN N/A
HI-RESOLUTION OFF
BACK
EXIT
Advanced setting 2
AE MODE:
WB MODE:
ALC, PLC:
Under the advanced setting, you can make
improvements to image quality due to different
environmental conditions.
Auto Exposure mode. Depends on the light
condition in the surveillance area, you can set the AE in
different modes and adjust the parameters, such as
shutter speed, iris factor and brightness for the best
image quality.
White balance mode, a image improvement
based on DSP processing. you can also adjust the Red-
Gain or Blue-Gain to change the color tone.
Average and Peak Level Control,
additional setting to WB function. only avialble with
dedicated camera modules.
Function setting
In function setting menu, you can define and activate
different PTZ funcitons, such as preset points, auto
scan, tours and Pattern. Presets and tour functions
can also be set or activated directly from keyboard
device without OSD. Please refer to the keyboard’s
manual for operation details.
EDIT PRESET LABEL
LABEL
BACK
EXIT
:ROOM 1
PRESETS:
PRESET NUMBER:
SET PRESET:
SHOW PRESET:
CLEAR PRESET:
EDIT PRESET LABEL:
G65-70 Series supports up to
128 presets. The number can be selected from 0 to
128.
Defining the preset points directly in
OSD by entering this menu item and move the PTZ.
press IRIS-OPEN key on the keyboard to save. If the
preset is pointed within digital zoom, it will
automatically go back to max. optical zoom range in
order to provide the best image.
Moves to current preset point
Clear the current preset
For the current preset, you
can define a name which will be shon on the
operation screen once the preset is called. please
choose the preset number at first. The avaialbe
characters are: 0-9, A-Z, <,>,. and space.
PRESETS
PRESET NUMBER 001
SET PRESET
SHOW PRESET
CLEAR PRESET
EDIT PRESET LABEL
BACK
EXIT
SCAN
SCAN NUMBER:
SCAN SPEED:
SET LEFT LIMIT:
SET RIGHT LIMIT:
CLEAR SCAN:
RUN SCAN:
EDIT SCAN LABEL:
The SCAN function moves the PTZ between 2-
predefined points in constant speed.The
following parameters can be set:
cruising speed between the
points.
defines the left point.
defines the right point
Delete the scan setting
starting the scan function
set the name for the scan
G65-70 Series supports up to 4
scan.
SCAN
SCAN NUMBER 01
SCAN SPEED 63
SET LEFT LIMIT
SET RIGHT LIMIT
RUN SCAN
EDIT SCAN LABEL
BACK
EXIT
CLEAR SCAN
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
15
ENGLISH
ADVANCE SETTING 1
IR CUTTER FILTER AUTO
IR CUT ON TIME N/A
IR CUT OFF TIME N/A
MAX GAIN 28dB
BACK
EXIT
Advanced setting 1
IR CUT FILTER:
Max Gain:
Enables the removal of Infrared Cutter
Filter (IRC), also known as “DAY/NIGHT” mode. with the
removal of IRC, the camera turns into Black/White mode and
has higher sensibility to low-light or IR-Light in the night.
Selectable between On, Off, Auto or Time. Only available
on camera module with IRC function.
improve the image quality in the Night modus
FUNCTION SETTING
PRESETS
SCAN
PATTERNS
TOUR
ZONES
TIME RUNNING
AUTO-TRACKING
BACK
EXIT

6.OSD - Patterns, Tours 6.OSD - Zones and Privacy Mask
PATTERNS Pattern
Pattern records the user’s operation steps on
performing PTZ control and stores as a track.
The G65 and G70 Series can record up to 4
tracks with max. 180 sec. each.
PATTERN NUMBER:
PROGRAM PATTERN:
RUN PATTERN:
CLEAR PATTERN:
EDIT PATTERN LABEL :
Selects the pattern number,
from1to4
Starts recording the
pattern when selected. you can perfome PTZ
movement for recording and shall not exceed 180
sec. Press IRIS-OPEN to save the track.
Starts the current pattern
Delete curretn pattern.
Sets the name for
current pattern.
PATTERN NUMBER 1
PROGRAM PATTERN
RUN PATTERN
CLEAR PATTERN
EDIT PATTERN LABEL
BACK
EXIT
Tour
Tour is an auto-run through selected preset
points with definable pause time. A tour can
store up to 32 presets points.
TOUR DWELL:
TOUR PRESETS:
RUN TOUR:
pause time for every stop on
the preset points. selectable between 000-
255(s).
press IRIS-OPEN Key on the
keyboard device to enter the preset point
selection. Move the joystick with up and down
to select the preset points by number and save
the setting with IRIS-OPEN key. with IRIS-
CLOSE key you can move to the previous
selection.Ifaselectpointhasthevalue0,all
the following presets points will be ignored.
Starts the tour and exit the OSD
menu.
EDIT TOUR
TOUR DWELL 001
00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
RUN TOUR
BACK
EXIT
Zone
You can define the zones in the whole PT range up
to with individual label. When the
display setting “Zone Label” is activated, the
label will be displayed on the operation screen.
The definition of the zones should not be
overlapped.
upto8zones
ZONES NUMBER:
SET LEFT LIMIT:
SET RIGHT LIMIT:
CLEAR ZONE:
EDIT ZONE LABEL :
Current zone selection
Left limit of the current zone
Right limit of the current zone
Delet the current zone
change the laben of current
zone.
ZONES
ZONES NUMBER 1
SET LEFT LIMIT
SET RIGHT LIMIT
CLEAR ZONE
EDIT ZONE LABEL
BACK
EXIT
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
17 18
ENGLISH
TIME RUNNING
DAY SUN
TIME CHANNEL 1
START TIME 00:00
END TIME 00:00
RUNNING NONE
BACK
EXIT
Time Running
You can set up the timer to start a function like
preset, tour or pattern. Each day can be set 4
action.
AUTO TRACKING
DAY SUN
STATE ON
START TIME 00:00
END TIME 00:00
SENSITIVE LOW
TRACKING-ZOOM OFF
SET LEFT LIMIT
SET RIGHT LIMT
BACK
AUTO TRACKING
Auto-Tracking can seach people or object with
high speed and low light performance.
DAY: set current day
STATE: activateAUTO-TRACKINGonthisday
START TIME: set the time for activation
ENDTIME:setthetimeforstopthetracking
SENSITIVE: set the sensitivity for the detection
SET LIMIT: set the max. angle for the tracking.

6.OSD - Alarm Setting
Alarms
RESUME: Continue the function on the camera , if it
was setting before the alarms.
RESET DELAY: How long the camera stay in Alarm
position.
ALARM CONTACT: Setting between N/C (normal
Close) or N/O (normal Open).
ALARM NUMBER: curent Alarm number.
ALARM ACTION: Setting for PRESET, SCAN, TOUR,
PAT 1-4, or NONE, if the camere in Alarm position.
ACTIVATE AUX:
ALARM PRIORITY:
Setting Alarm Output, when Alarm is
activate. Select between AUX1, AUX2 (not connected)
or BOTH.
define the priority of the alarm input.
ARM SETTING: define the operation timer of the alarm
ENGLISH
7. Dome Address & Protocol
Sw1 Sw2
Protocol setting
In order to establish a connection for
telemetric control with keyboard device. you
need to setup the dome address and protocol.
The G65 and G70 series are capable with
multiple communication protocol. The setting
can be changed through the DIP-Switches on
the rear side of the connector boards as
Illustrated.
please use the following table for details setup.
current pattern.
Baud rate DIP 7 DIP8
2400 bps 0 0
4800 bps 1 0
9600 bps 0 1
19200 bps 1 1
SW 1:
represent the domes address in binary form.
please refer to the list on next page for reference.
SW 2:
Used for protocol settting and baud rate.
DIP1to6:Protocolsetting
DIP 7 and 8: Baud rate setting
Protocol / DIP 123456
VIDO B02 001100
DIAMOND 100100
HUNDA 101100
KALATEL 010100
LILIN 110100
MOLYNX 001000
PANASONIC 111000
PELCO (D/P) 100000
PHILIPS 000001
SAE 010000
SAMSUNG 000100
SANTACHI 011000
UNIVISION 010001
VCL 110000
VICON 101000
AD 001100
Some products may not be available in your country, please contact our distributor for more details
ALARM SETTING
ALARM NUMBER 001
ALARM ACTION TOUR
ACTIVATE AUX AUX1
ALARM PRIORITY LOW
BACK
EXIT
Note: VIDO B02 Protocol is fully
compatible with VIDO B01. For
previous version of Vido products
please set to B02
WINDOW BLANKING
WINDOW NUMBER 01
EDIT WINDOW
ENABLE WINDOW OFF
CLEAR WINDOW
BACK
EXIT
Privacy Mask ( Window Blanking)
Privacy Mask is used to protect the privacy area not to be
displayed once the camera is pointed on, such asu
levatory area or the operation desk of an ATM machine. It
might be required for video surveillance application
depends on the local law regulation. The G65 and G70
supports up to 24 private masks. ( depends on installed
camera module, please contact your local sales
representative for more information)
Hitachi camera modules
Sony Camera modules:
LG,CNB Camera modules:
: 8 masking area.
up to 24 masking area( except
the45seriesprovidesonly8)
no masking function.
WINDOW NUMBER:
EDIT WINDOW:
ENABLE WINDOW:
CLEAR WINDOW:
Mask number
Edit position of the mask by joystick of
the keyboard. presse IRIS-OPEN to save.
shows the mask on screen OFF
Delete the mask
ALARMS
Resume OFF
SEQUENCE 001
RESET DELEY 030
ALARM CONTACT N/O
ALARM SETTING
ARM SETTING
BACK
EXIT
ARM SETTING
DAY SUN
ARM STATE OFF
ARM TIME N/A
UNARM TIME N/A
BACK
EXIT
19

7. Address ID, 1 to 67
8 00010000 42 01010100
9 10010000 43 11010100
10 01010000 44 00110100
11 11010000 45 10110100
12 00110000 46 01110100
13 10110000 47 11110100
14 01110000 48 00001100
15 11110000 49 10001100
16 00001000 50 01001100
17 10001000 51 11001100
18 01001000 52 00101100
19 11001000 53 10101100
20 00101000 54 01101100
21 10101000 55 11101100
22 01101000 56 00011100
23 11101000 57 10011100
24 00011000 58 01011100
25 10011000 59 11011100
26 01011000 60 00111100
27 11011000 61 10111100
28 00111000 62 01111100
29 10111000 63 11111100
30 01111000 64 00000010
31 11111000 65 10000010
32 00000100 66 01000010
33 10000100 67 11000010
Switchnumber (Sw1) Switchnumber (Sw1)
Bit12345678 Bit12345678
1 10000000 35 11000100
2 01000000 36 00100100
3 11000000 37 10100100
4 00100000 38 01100100
5 10100000 39 11100100
6 01100000 40 00010100
7 11100000 41 10010100
ID ID
00000000 0100010034
Bit12345678 Bit12345678
00100010 01100110
10100010 11100110
01100010 00010110
11100010 10010110
00010010 01010110
10010010 11010110
01010010 00110110
11010010 10110110
00110010 01110110
10110010 11110110
01110010 00001110
11110010 10001110
00001010 01001110
10001010 11001110
01001010 00101110
11001010 10101110
00101010 01101110
10101010 11101110
01101010 00011110
11101010 10011110
00011010 01011110
10011010 11011110
01011010 00111110
11011010 10111110
00111010 01111110
10111010 11111110
01111010 00000001
11111010 10000001
00000110 01000001
10000110 11000001
01000110 00100001
11000110 10100001
00100110 01100001
10100110 11100001
ID ID
Switchnumber (Sw1)
69
70
71
72
74
103
75
76
77
78
79
80
82
83
73
84
85
86
87
88
89
90
91
93
94
95
96
97
98
99
100
101
92
81
68
104
105
106
107
110
108
111
112
113
114
115
116
117
118
119
121
109
122
123
124
125
126
127
128
129
130
131
133
120
134
135
132
Switchnumber (Sw1)
102
7.Address ID, 68 to 135

7. Address ID, 136 to 203
Bit12345678 Bit12345678
00010001 01010101
10010001 11010101
01010001 00110101
11010001 10110101
00110001 01110101
10110001 11110101
01110001 00001101
11110001 10001101
00001001 01001101
10001001 11001101
01001001 00101101
11001001 10101101
00101001 01101101
10101001 11101101
01101001 00011101
11101001 10011101
00011001 01011101
10011001 11011101
01011001 00111101
11011001 10111101
00111001 01111101
10111001 11111101
01111001 00000011
11111001 10000011
00000101 01000011
10000101 11000011
01000101 00100011
11000101 10100011
00100101 01100011
10100101 11100011
01100101 00010011
11100101 10010011
00010101 01010011
10010101 11010011
ID ID
Switchnumber (Sw1)
171
172
173
174
175
176
177
179
170
180
181
182
183
184
185
186
187
188
189
190
191
193
178
194
195
196
197
198
199
200
201
202
203
192
Switchnumber (Sw1)
136
137
138
139
140
141
142
143
145
146
147
148
149
150
151
152
153
154
155
156
157
159
144
160
161
162
163
164
165
166
167
168
169
158
Switchnumber (Sw1)
(Bit)1 2345678
00110011 01110111
10110011 11110111
01110011 00001111
11110011 10001111
00001011 01001111
10001011 11001111
01001011 00101111
11001011 10101111
00101011 01101111
10101011 11101111
01101011 00011111
11101011 10011111
00011011 01011111
10011011 11011111
01011011 00111111
11011011 10111111
00111011 01111111
10111011 11111111
01111011
11111011
00000111
10000111
01000111
11000111
00100111
10100111
01100111
11100111
00010111
10010111
01010111
11010111
00110111
10110111
ID ID
204
206
207
209
239
210
211
208
213
214
216
217
212
218
219
220
222
223
224
225
227
228
230
226
231
232
234
229
235
237
233
236
215
221
Switchnumber (Sw1)
(Bit)12345678
240
241
242
244
238
245
247
243
248
249
250
251
253
246
254
255
252
205
7. Address ID, 204 to 255

8. Specification G65 Series
Some products may not be available in your country, please contact our distributor for more details
25
Tilt Range
Communication
Preset Positions
Auto Pan
Tour / Sequence
Alarm inputs
Operating Temp.
Power
0-90°
RS-485, multiple-protocol, coax
128 Presets
Yes, between 2 presets
4 progr. Tours with max 32 presets/ 4 Pattern up to 180s
7 inputs / 2 output
Indoor: -10 5℃to 0℃
24V AC / 24 -60 VA
Tilt Speed
Pan Range
0.4° - 150° per Sec.
360°
Iris Control
Gain Control
Video Output
S/N Ratio
Pan Speed
Auto / Manua/ Auto Slow Shutter
Auto / Manual (-3 to 28 dB, 2 dB steps, 16steps)
VBS: 1.0Vp-p (Sync Negative), Y / C Output
0.4° - 300° per Sec.
Shutter Speed 1 to 1/10,000 Sec. 1/3 to 1/10,000 Sec.
Focus
White Balance
Auto / Manual
Auto / Manual (ATW, Indoor, Outdoor, One Push WB, Manual WB)
Wide Dynamic Function (SB18WD/ SB26WD / SB36WD models)
Night: 0.01Lx (1/3)
Night: 0.7Lx (1/50), 0.05Lx (1/3)
Viewing Angle
Image Sensor 1/4 inch Ex-View CCD
Model AU-G65-SC18 AU-G65-SB18 AU-G65-SB26 AU-G65-SB36
Day / Night Day / NightDay / Night
Signal Format
Scanning
PAL/NTSC
Progressive
H. Resolution 470 TVL, 440K Pixels (PAL)
48.0° (Wide end) 54.2° (Wide end)
2.2° (Tele end)
57.8° (Wide end)
1.7° (Tele end)2.8° (Tele end)
Zoom
Min. Illumination
18× Opt. / 12× Digital 26× Opt. / 12× Digital 36× Opt. / 12× Digital
0.7 Lux (1/50 sec., Color) Day: 0.7Lx (1/50), 0.1Lx (1/3) Day: 2.0Lx (1/50), 0.14Lx (1/3) Day: 1.4Lx (1/50), 0.1Lx (1/3)
Night: 0.01Lx (1/3)
-
More than 50 dB
470 TVL / 540 TVL
(High Resolution)
8. Specification G70 Series
Some products may not be available in your country, please contact our distributor for more details
ENGLISH
AU-G65-SB18WD
with WDR
AU-G65-SB26
AU-G65-SB26WD
with WDR
AU-G65-SB36WD
with WDR
Tilt Range
Communication
Preset Positions
Auto Pan
Tour / Sequence
Alarm inputs
Operating Temp.
Power
0 - 90°
RS-485, multiple-protocol, coax
128 Presets
Yes, between 2 presets
4 progr. Tours with max 32 presets/ 4 Pattern up to 180s
7 inputs / 2 output
Outdoor: -40°C to 60°C
24V AC / 24 -60 VA
Tilt Speed
Pan Range
0.4° - 150° per Sec.
360°
Iris Control
Gain Control
Video Output
S/N Ratio
Pan Speed
Auto / Manua/ Auto Slow Shutter
Auto / Manual (-3 to 28 dB, 2 dB steps, 16steps)
VBS: 1.0Vp-p (Sync Negative),Y/COutput
0.4° - 300° per Sec.
Shutter Speed 1 to 1/10,000 Sec. 1/3 to 1/10,000 Sec.
Focus
White Balance
Auto / Manual
Auto / Manual (ATW, Indoor, Outdoor, One Push WB, Manual WB)
Wide Dynamic Function (SB18WD/ SB26WD / SB36WD models)
Night: 0.01Lx (1/3)
Night: 0.7Lx (1/50), 0.05Lx (1/3)
Viewing Angle
Image Sensor 1/4 inch Ex-View CCD
Model AU-G70-WC18 AU-G70-WB18 AU-G70-WB26 AU-G70-WB36
Day / Night Day / NightDay / Night
Signal Format
Scanning
PAL / NTSC
Progressive
H. Resolution 470 TVL, 440K Pixels (PAL)
48.0° (Wide end) 54.2° (Wide end)
2.2° (Tele end)
57.8° (Wide end)
1.7° (Tele end)2.8° (Tele end)
Zoom
Min. Illumination
18× Opt. / 12× Digital 26× Opt. / 12× Digital 36× Opt. / 12× Digital
0.7 Lux (1/50 sec., Color) Day: 0.7Lx (1/50), 0.1Lx (1/3) Day: 2.0Lx (1/50), 0.14Lx (1/3) Day: 1.4Lx (1/50), 0.1Lx (1/3)
Night: 0.01Lx (1/3)
-
More than 50 dB
470 TVL / 540 TVL
(High Resolution)
AU-G70-WB18WD
with WDR
AU-G65-SB26
AU-G70-WB26WD
with WDR
AU-G70-WB36WD
with WDR

This manual suits for next models
12
Table of contents
Other Vido.at Security Camera manuals