3
1. Fill the chemical tank ①with 2 diesel and 30~50cm3 pesticide and then dilute
them.
2. Put the full of water in the coil-cooling water tank ②and fix the liquefied
butane gas ④onto the screen smoke gadget.
3. Check the coil for smoke screen ⑨which is available (coilclogging) by turning
the smoke screen & cooling control lever ⑧at the cooling position and then
operating the cooling water pump ③.
4. After opening the gas control lever ⑤, checking its gas ignition and pushing the
ignition switch ⑥for its ignition, turn the Smoke screen & cooling control lever
⑧at the smoke screen position and then clench and unclench the smoke
screen pump lever ⑦with hand continuously. After that, the smoke screen is
activated.
(The coil will be clogged if you does not operating the smoke screen pump lever
and you leave it in the condition of the ignition.)
5. After finishing the smoke screen work, turn the Smoke screen & cooling control
lever ⑧at the cooling position and close the gas control lever ⑤immediately.
When the heat remains on the coil for smoking screen ⑨, you should operate
the cooling water pump ③to clean the coil for smoking screen ⑨that
prevent the coil from being clogged and guarantee its long-term use.
Caution:
After use, remove the liquefied butane gas from the gadget.
After use, remove the chemical tank from the gadget in case of long-term keeping.
Maintain the interval as 8mm against the ignition insulator.
When fixing the butane gas onto the screen smoke gadget, fit the gas
holder into the gas fixation bracket projection and turn it right to fix it strongly.
Warning!
When the coil is clogged, you must stop working.
Overuse causes damage on any other parts.
Use diesel only. (Never use kerosene or gasoline).