Vlano 100 PRIM User manual

DE AXIAL FAN
operating manual
100 PRIM
www.vlano.de

DE
CONTENT
Scope of delivery................................................. .................................................. .................................................. .................................................. .................................. 6
Brief description ................................................. .................................................. .................................................. .................................................. ....................... 6
Operating rules ................................................. .................................................. .................................................. .................................................. ................... 6
Designation key ................................................. .................................................. .................................................. .................................................. ........... 7
Assembly................................................. .................................................. .................................................. .................................................. ............................................ 7
Variants of the fan ............................................... .................................................. .................................................. .................................................. ........... 8th
Operation setting of the fan ............................................... .................................................. .................................................. ...................................... 8th
Maintenance instructions ................................................. .................................................. .................................................. .................................................. ...................... 11
Storage and transport regulations .............................................. .................................................. .................................................. .............................. 11
Manufacturer's guarantee ................................................. .................................................. .................................................. .................................................. ........................ 12
2

DE
These operating instructions are the most important document for operation and are aimed at specialist and maintenance staff
as well as operating personnel. The operating instructions contain information on the intended use, technical data, mode of
operation and installation of the 100 PRIM device and all its modifications.
Skilled and maintenance personnel should have completed training in the area of ventilation and must carry
out the work in accordance with the applicable local work safety regulations, building codes and standards.
The information given in these operating instructions is believed to be correct at the time this document was
written. In order to implement current technical developments, the company reserves the right to make
changes to the design, technical properties and scope of delivery of the device at any time. No part of this
publication may be reproduced, transmitted, stored in an information search system, or translated into any
other language in any way without the prior written consent of the company.
READ THESE OPERATING INSTRUCTIONS BEFORE INSTALLING THE DEVICE
CAREFULLY THROUGH.
COMPLIANCE WITH THE OPERATING INSTRUCTIONS ENSURES SAFE OPERATION OF THE
DEVICE DURING THE ENTIRE LIFE OF USE.
KEEP THESE OPERATING INSTRUCTIONS AS LONG AS YOU USE THE DEVICE
OPERATE AS THIS CONTAINS ALL MAINTENANCE INSTRUCTIONS.
3

DE
MEET THE PRESENT OPERATING REQUIREMENTS,
FOR PROPER FUNCTION AND LONG SERVICE LIFE OF THE FAN
TO ENSURE.
The device must be disconnected from the power supply before all connection, adjustment, maintenance and repair
work.
Service and maintenance work must only be carried out by qualified personnel
who have a valid license for electrical work on electrical systems up to 1000V.
Read the operating instructions before starting any work on the device.
The single-phase network to which the device is connected must comply with the applicable
electrical standards.
The cabling system must have a circuit breaker.
The electrical connection is made via a circuit breaker QF, which is integrated in the
stationary line. The contact distance must be at least 3 mm at all poles.
Before installing the device, check it for visible defects on the impeller, housing and
grille. Furthermore, it must be ensured that there are no foreign bodies in the housing
that could damage the impeller blades.
During assembly, make sure that the housing is not deformed! Deformation of the
housing can cause the motor to stall and loud noises.
Improper use, unauthorized changes and reworking as well as modifications to the
device are prohibited.
Take precautions to ensure that smoke, carbon oxide gases and other flammable substances
cannot enter the room through open smoke vents or other fire protection devices. In order to
avoid a back pressure of air and at the same time a proper combustion of exhaust gases
4th

DE
and gases through the chimney, care must be taken to ensure that there is an adequate supply of air.
The conveying air must not contain any dust, vapors, solid foreign matter, sticky substances or fibers.
The device is not designed for use in a flammable or explosive environment that
contains, for example, alcohol fumes, gasoline or insecticides.
Do not close or cover the air inlet and outlet openings in order to ensure an optimal air
flow.
Please do not sit on the device or leave any objects on it.
This device may only be used by children from the age of 8 and persons with limited
physical, mental or sensory abilities or without sufficient experience and knowledge if
they have been supervised or have been instructed in the safe use of the device and
have understood the resulting dangers. Do not let children play with the device.
AFTER ITS SERVICE LIFE, THE DEVICE MUST BE DISPOSED OF SEPARATELY.
THE DEVICE MUST NOT BE DISPOSED OF AS UNSORTED URBAN WASTE.
5

DE
SCOPE OF DELIVERY
Fan: 1 pc.
Screws and dowels: 4 pieces Plastic
screwdrivers: 1 piece Operating
instructions: 1 piece
Packaging box: 1 pc.
SHORT DESCRIPTION
The product described in the operating instructions is an axial fan for the ventilation of small to medium-sized
living spaces that are heated in winter.
The fan is compatible with pipe systems with a diameter of 100 mm. The fan is equipped with a non-return flap
to prevent air backflow in standby mode.
OPERATING INSTRUCTIONS
The fan is designed for connection to a single-phase AC network with a voltage of 220-240 V / 50 (60) Hz or 12 V / 50 Hz
(depending on the model) and is intended for continuous operation without being disconnected from the mains. The direction
of airflow in the system is indicated by an arrow on the fan housing.
Degree of protection against ingress of foreign bodies and protection against water IP45.
The fan is designed for use in ambient temperatures from +1 ° C to +45 ° C. The
device belongs to the electrical systems of class II (220-240 V / 50 (60) Hz).
6th

DE
DESIGNATION KEY
100 PRIM DC X A.
Colour:
Additional options:
_: White
V: cord switch
T: overrun switch
TH: humidity sensor and overrun switch
TP: motion sensor and overrun switch
DC: DC motor
Nozzle diameter, mm
ASSEMBLY
The fan is designed for ceiling or wall mounting for ventilation in a ventilation shaft or in a ventilation pipe with
the appropriate diameter (Fig. 2).
The installation of the fan with a direct air outlet upwards is not permitted (Fig. 2).
Installation steps of the fan:
Step 1. Disconnect the device from the power supply and ensure that the power is switched off (Fig. 3).
Step 2. Route the power cable to the ventilation opening (Fig. 4).
Step 3. Remove the cover from the fan. Then remove the cover from the printed circuit board (Fig. 5).
Step 4. Mark and drill the mounting holes and mount the fan (Fig. 6-8).
Step 5. Connect the fan to the power supply in accordance with the connection diagram (Fig. 12).
Step 6. Put the protective cover (Fig. 9) and the design cover (Fig. 10) back on the fan housing.
Step 7. Reconnect the power supply to the fan (Fig. 11).
Designations of the terminals on the connection diagrams:
L: Phase (only for electrical network 220-240 V)
N: Zero (only for 220-240 V electrical network)
S: external switch
QF: Circuit breaker
LT (ST): Control chain of the timer
7th

DE
VARIANTS OF THE FAN
100 PRIM (V) T: the fan is equipped with an overrun switch. The fan starts operation when an external switch
(eg a light switch) is actuated and a supply voltage is input to the terminalLT.
After disconnecting the supply voltage, the fan continues to operate for the set run-on time, which is set via
the DIP switch.
VT Models are equipped with a cord switch.
100 PRIM TP: the fan is equipped with a motion sensor and an overrun switch. The fan works in one of the
four operating modes that are set using the DIP switch.
100 PRIM (V) TH: the fan is equipped with a humidity sensor and overrun switch. The fan works in one of the
four operating modes that are set using the DIP switch.VT Models are equipped with a cord switch.
OPERATIONAL SETTING OF THE FAN
THE BOARD OF THE TIMER IS POWERED! THE FAN BEFORE EVERYONE
DISCONNECT SETTING WORK FROM THE POWER SUPPLY!
The fan is set to operate by switching the DIP switch. To access the DIP switch, remove the cover and open the
rubber cover (Fig. 13). A plastic screwdriver for switching the DIP switch is included in the scope of delivery.
DO NOT USE METAL SCREWDRIVERS, KNIVES, OR
OTHER SHARP OBJECTS TO DAMAGE THE CONTROL BOARD.
8th

DE
100 PRIM (V) T
functionality speed
Operation via external
counter
Low speed
of the fan
High speed of the
Fan
Continuous operation of the fan
Overrun switch
The timer is switched off. 5 minutes delay 15 minutes delay 30 minutes delay
100 PRIM (V) TH, 100 PRIM (V) TP
functionality
When the sensor or
switch is triggered, the
fan runs at a lower speed
Speed.
When the sensor or
switch is triggered, the
fan runs at a high speed
The fan is running
permanently at low
speed. At
If the sensor or switch is
triggered, the fan runs
at high speed.
The fan is
switched off. When triggered
switch, the fan runs
at low speed. At
If the sensor is
triggered, the switched
on fan runs at high speed.
Speed.
9

DE
Overrun switch
The timer is switched off.
The delay for 5 minutes delay 15 minutes delay 30 minutes delay
100 PRIM (V) ТР is 30
Seconds.
Humidity set point
60% 70% 80% 90%
10

DE
MAINTENANCE INSTRUCTIONS
Maintenance work on the fan must be carried out after 6 months at the latest.
Maintenance steps:
• Disconnect the device from the power supply and ensure that the power supply is switched off (Fig. 14).
• Remove the covers and clean the fan with a soft cloth or brush (Fig. 15).
• Rinse the cover with tap water (Fig. 16).
• Dry the surface of the fan.
• Put the covers back on the fan.
• Connect the fan to the power supply (Fig. 17).
WARNING! The electrical components must be protected from splashing water!
STORAGE AND TRANSPORT REGULATIONS
• Store the device in the original packaging in a ventilated room at a temperature of +5 ° C to + 40 ° C and a
relative humidity of max. 70%.
• Vapors and foreign substances in the air, which can cause corrosion and damage connection seals, are not
permitted.
• Use lifting gear during cargo handling work to prevent possible damage.
• The transport requirements for this type of cargo must be met.
• The transport with vehicles of any kind must be carried out under constant protection from harmful mechanical and
weather-related influences. Only transport the device in the operating position.
• Carry out loading and unloading work carefully, protect against impacts.
• If the device has been transported at low temperatures, leave it to stand at operating temperature for at least 3-4
hours before switching it on.
11

DE
MANUFACTURER'S WARRANTY
The product complies with European norms and standards, the directives on low voltage and electromagnetic
compatibility. We hereby declare that the product complies with the relevant requirements of directive
2014/30 / EU on electromagnetic compatibility, low-voltage directive 2014/35 / EU and directive 93/68 / EEC on
CE marking.
This certificate is issued for the above after testing the product.
The manufacturer sets a guarantee period of 24 months from the date of sale through retailers, provided that
the consumer fulfills the regulations for transport, storage, assembly and operation.
In the event of malfunctions in the device due to errors caused by the factory that occur within the warranty period,
the consumer is entitled to free repair of the device defects by means of warranty repair by the manufacturer.
The warranty repair includes, in particular, work to remedy defects in the operation of the device in order to
ensure that the device is used as intended within the warranty period.
Defects are remedied by replacing or repairing the defective parts or units of the device.
The warranty service does not include:
• regular technical maintenance
• Assembly / disassembly of the device
• Set up the device
For warranty repairs, the consumer must present the device, the operating instructions with the date of purchase and
proof of payment as confirmation of the purchase.
The model of the device presented must match the model specified in the operating instructions. Contact the
seller of the device for warranty service.
The guarantee does not apply in the following cases:
• The consumer does not submit the fan completely, as stated in the operating instructions, including the components
of the device dismantled by the consumer.
• Incompatibility of the model or brand of the device with the information on the packaging and in the operating
instructions.
• Failure to timely technical maintenance of the device by the consumer.
• In the event of external damage to the housing and internal units (except external
12th

DE
Changes to the device that are necessary for assembly).
• Changes to the construction of the device or technical changes to the device.
• Replacement and use of units or parts that are not intended by the manufacturer.
• Inappropriate use of the device.
• Violation of the assembly instructions for the device by the consumer.
• Violation of the regulations for controlling the device by the consumer.
• Connection of the device to a power supply system with a voltage other than that specified in the operating instructions.
• Failure of the device as a result of voltage jumps in the power grid.
• Carrying out independent repairs to the device by unauthorized persons.
• Repairs to the device by persons who are not authorized by the manufacturer.
• The device's warranty period has expired.
• Violation of applicable regulations for the transport of the device by the consumer.
• Violation of the regulations on the storage of the device by the consumer.
• Unlawful acts by third parties in relation to the device.
• Failure of the device as a result of force majeure (fire, flood, earthquake, war, military action of any kind,
blockades).
• Missing seals, if such are provided for in the operating instructions.
• Failure to present the operating instructions with the specified date of purchase.
• Lack of proof of purchase with the date of purchase, which confirms the purchase.
MEET THE PRESENT OPERATING REQUIREMENTS IN ORDER TO PROPERLY
TO ENSURE FUNCTION AND A LONG SERVICE LIFE OF THE DEVICE.
THE WARRANTY CLAIMS CAN ONLY BE MADE IF THE DEVICE, A PROOF OF
PURCHASE AND THE OPERATING INSTRUCTIONS NOTING THE DATE OF PURCHASE
IS, PRESENT.
13

DE
108 158 136
81
ø99
1.
2.
14th

DE
LN A
QF
OUT
3rd 4th 5.
6th 7th 8th.
A
OUT
9. 10. 11.
15th

DE
QF S. LT
L.
N
1
2
3
L.
N
12th 13.
LN A
QF
OUT
14th 15th
A
OUT
16. 17th
16

DE
17th

DE
18th

DE
Certification mark Sold by
(Name and stamp of the dealer)
manufacturing date Purchase date
19th

Acceptance report
V.
T
100 PRIM DC
TP
TH
The fan is recognized as operational.
VLN162DE-03
Table of contents
Other Vlano Fan manuals
Popular Fan manuals by other brands

S&P
S&P TD-350/125 SILENT instruction manual

ZEN HOME
ZEN HOME J42003-XY-1L Installation instruction

Addvent
Addvent AVX 230 Series Installation instruction

Triangle Engineering
Triangle Engineering HEAT BUSTER TPC 4815 owner's manual

Vents
Vents MPA 300 E EC A30 user manual

Lorell
Lorell 44552 operating instructions

Hunter
Hunter 20517 Parts guide

Visual Comfort & Co.
Visual Comfort & Co. Maverick 3MAVR70AGPD manual

Lasko
Lasko 1850 Important instructions & operating manual

Delta Electronics
Delta Electronics FFB0612UHE Dimensions and installation information

Lasko
Lasko 1820 operating manual

Hinkley Lighting
Hinkley Lighting VENTUS instruction manual