~ DOMESTIC HEATING APPLIANCES
®
~
..
'---.J
.. ..
l-
Meteor
890
Users
Instructions
CE
British Gas Service Listed
G.C. No. 47 094 21
HAND THESE
INSTRUCTIONS
TO THE USER
BEFORE ATTEMPTING TO LIGHT APPLIANCE PLEASE MAKE SURE THAT IT IS CHARGED UP WITH
WATER WITH THE NEEDLE POINTING AT 1bar ON THE PRESSURE GAUGE (4)
Gas Safety (Installation and Use) Regulations 1994
Inyour own interests and that of safety,it is the law that all gas appliances are installed and serviced by a
competent person in accordance with the above regulation.
GAS LEAK OR FAULT
IF A FAULT OR GAS lEAK IS SUSPECTED, TURN OFF THE APPLIANCE AND CONTACT YOUR INSTAllATION
COMPANY OR lOCAL GAS REGION.
Your Vokera Meteor S90 is a central heating boiler,and
with the addition of an indirect hot water cylinder it can
supply stored hotwater.
-1
2
3
Boiler Location
Clearances
Minimum - above casing 25mm
Minimum - behind (rear exit flue) 60mm
Minimum - behind (side exit or vertical flue) 115mm
Minimum - In front 600mm
Minimum - At sides 12.5mm from casing
If fitted in a compartment,the purpose provided
ventilation openings must not be blocked, and should
be checked periodically to ensure this.The compart-
ment should not be used as a storage cupboard
(e.g. for food).
NEVER HANG CLOTHES ETC. OVER THE
APPLIANCE.
Ignition Reset Button
On/Off Switch
Thermostat Control Knob
Temperature/Pressure Gauge
WARNING:
THIS APPLIANCE MUST BE EARTHED
Connection should be made to a 230v - 50Hz supply.
The appliance must be protected by a 3amp fuse if a
13amp (BS 1363)plug or fused spur is used.
To connect a plug:
As the colour of the wires in the mains lead to this
appliance may not correspond with the coloured
markings identifying the terminals in your plug, pro-
ceed as follows:-
The wire which is coloured green-and-yellow must be
connected to the terminal in the plug which is marked
with the letter E or by the earth symbol
i=-
or col-
oured green or green-and-yellow.
The wire which is coloured blue must be connected to
the terminal which is marked with the letter N or
coloured black
The wire which is coloured brown must be connected
to the terminal which is marked with the letter l or
coloured red.
1.0 LIGHTING THE BOILER.3.0 SHUTTING DOWN THE SYSTEM
For short periods:
1.1 Switch on the electrical supply at the mains Turn the on/off switch (2) to
0
isolated point.For longer periods also:
1.2Ensure the gas supply to the appliance is turned Turn off gas cock and
on.Turn off main electricity supply to boiler.
1.3To gain access to the control facia,lower the However,if the building is vacated when there
upper panel by use of the key provided.is risk of freezing shut down the boiler as
NOTE:If additional keys are required they can described and drain the system:
be obtained by contacting your local spare parts
stockist.Open all heating radiator valves,open the drain
cock within the appliance as well as drain cocks
1.4Turn the on/off switch (2)to 1 usually provided at the lowest point of the
system.To ensure draining of radiators, open
1.5 Should the appliance have external controls i.e.radiator air cocks remembering to close them
room thermostat or timeclock,ensure that they when the operation is complete.
are turned on and are calling forheat.The
appliance will now go through an ignition Alternatively,install a frost stat and leave the
sequence and the burner will light.mains electricity and gas supply turned on.
1.6Should the appliance fail toignite and the N.B. Refilling a sealed system mustbe undertaken
ignition reset button (1)illuminate.Depress the by a competent person following approved
ignition reset button and the boilerwill go procedures.
through the ignition sequence again.If the cut
out operates again, the appliance must be 4.0 RELIGHTING THE BOILER
checked by a competent person,before relight- Relight by following steps 1.0to1.6 given
ing.previously,after ensuring that refilling
&
venting
of the sealed system has been carried out.
1.7 Adjust the Central heating temperature control
(3)to suitthe weatherconditions.5.0 CLEANING THE OUTER CASE
Use a clean damp cloth.Do not use abrasive
N.B (i) For the quickest heatup of the premises the cleaners.
highest setting is needed at first,turning down
later.6.0 SPARE PARTS AND SERVICING
Your Vokera Meteor must be serviced annually.
(ii) When Room Thermostats are used it may Please contact your local Vokera Service
be best to leave the boiler thermostatat a high Agent,your local Gas Region or a competent
setting and set the room thermostat as required. Installer.
2.0 SAFETY LIMITS 7.0 FLUE
In cold or humid weather watervapour may
2.1Systems pressure condense when leaving the flue terminal.The
The water pressure gauge(4)mustread be- effect of such steaming is normal.
tween 1 and 1.5bar when the system is cold.
Leaks or radiator venting will reduce this.Call in
your service installer if excessive topping up of
the system to restore pressure is necessary.A
built-in safety valve operates ifboiler pressure
exceeds 3bar whether hot or cold.If the safety
valve operates (water/steam discharges to
drain)switch off and call yourInstaller or
Service Engineer.
2.2 If the appliance watertemperature rises too
high,ahigh limit thermostat operates to extin-
guish the burner.This will resetautomatically
when the boiler temperature cools to within the
working limits.If the cut out operates again,the
appliance must be checked bya competent
person, before relighting.
2Meteor S90 User
.J...
.J
..L/
1.~
okera
G.R
Claudio (Vokera) Ltd
Head Office and Accounts: Clarisham House,Morson Road,Enfield,Middlesex EN3 4NQ Tel.0181-804 7202 Fax.0181-804 8163
Northern Region:Stubs Beck Lane,West 26 Business Pari<,Whitehall Road, Clec:kheaton,West Yori<shire BD19 4TT Tel. 01274865556 Fax. 01274 865557
ScoUish Region:ShunaStreet,Maryhill,GlasgowG209NWTel.0141-9454944 Fax.0141-9455136

Other VOKERA Boiler manuals

VOKERA Eclipse ESC Release note

VOKERA

VOKERA Eclipse ESC Release note

VOKERA Vision S User manual

VOKERA

VOKERA Vision S User manual

VOKERA Vision C User manual

VOKERA

VOKERA Vision C User manual

VOKERA Neutro Release note

VOKERA

VOKERA Neutro Release note

VOKERA unica he User manual

VOKERA

VOKERA unica he User manual

VOKERA Linea User manual

VOKERA

VOKERA Linea User manual

VOKERA Compact A User manual

VOKERA

VOKERA Compact A User manual

VOKERA Compact 29kW Reference guide

VOKERA

VOKERA Compact 29kW Reference guide

VOKERA MYNUTHE 35 HE User manual

VOKERA

VOKERA MYNUTHE 35 HE User manual

VOKERA Option User manual

VOKERA

VOKERA Option User manual

VOKERA Mynute 28SE User manual

VOKERA

VOKERA Mynute 28SE User manual

VOKERA Linea Max HE User manual

VOKERA

VOKERA Linea Max HE User manual

VOKERA Eclipse 216 ESS Release note

VOKERA

VOKERA Eclipse 216 ESS Release note

VOKERA Mynute 25 A User manual

VOKERA

VOKERA Mynute 25 A User manual

VOKERA UNICA 32 BHE User manual

VOKERA

VOKERA UNICA 32 BHE User manual

VOKERA MYNUTE 35HE Release note

VOKERA

VOKERA MYNUTE 35HE Release note

VOKERA Synergy 29 User manual

VOKERA

VOKERA Synergy 29 User manual

VOKERA CondexaPRO 50 M Release note

VOKERA

VOKERA CondexaPRO 50 M Release note

VOKERA Pinnacle User guide

VOKERA

VOKERA Pinnacle User guide

VOKERA Rain24 User guide

VOKERA

VOKERA Rain24 User guide

VOKERA Compact 24 SE Release note

VOKERA

VOKERA Compact 24 SE Release note

VOKERA Verve User manual

VOKERA

VOKERA Verve User manual

VOKERA Vibe 20 A G.C. N 41-094-84 User manual

VOKERA

VOKERA Vibe 20 A G.C. N 41-094-84 User manual

VOKERA Vision 25C User manual

VOKERA

VOKERA Vision 25C User manual

Popular Boiler manuals by other brands

New Yorker AP-U SERIES Installation, operation and service instructions

New Yorker

New Yorker AP-U SERIES Installation, operation and service instructions

M&G DuraVent DIS installation instructions

M&G

M&G DuraVent DIS installation instructions

Viadrus G 50 Series Manual for operation and installation

Viadrus

Viadrus G 50 Series Manual for operation and installation

Biasi Advance Plus 25C User manual and installation instructions

Biasi

Biasi Advance Plus 25C User manual and installation instructions

ACV Triangle Tube CHALLENGER SOLO Installation & maintenance manual

ACV

ACV Triangle Tube CHALLENGER SOLO Installation & maintenance manual

Potterton Performa SL HE Installation & service instructions

Potterton

Potterton Performa SL HE Installation & service instructions

Riello INSIEME EVOe 32 V LN Installation and maintenance manual

Riello

Riello INSIEME EVOe 32 V LN Installation and maintenance manual

Prestige Solo 175 User's information manual

Prestige

Prestige Solo 175 User's information manual

Alpha Alpha CB24 User instructions

Alpha

Alpha Alpha CB24 User instructions

Sime EDEA HM 40 Design, installation and servicing instructions

Sime

Sime EDEA HM 40 Design, installation and servicing instructions

IBC SL 35-199 operating instructions

IBC

IBC SL 35-199 operating instructions

Chaffoteaux & Maury Centora green Maintenance and service guide

Chaffoteaux & Maury

Chaffoteaux & Maury Centora green Maintenance and service guide

Union Steam GWA User's information manual

Union Steam

Union Steam GWA User's information manual

Beretta Exclusive 24 C.A.I. installer and user manual

Beretta

Beretta Exclusive 24 C.A.I. installer and user manual

Danfoss DWH 200 installation guide

Danfoss

Danfoss DWH 200 installation guide

STOKVIS ENERGY SYSTEMS Evolution Series Options & systems planner manual

STOKVIS ENERGY SYSTEMS

STOKVIS ENERGY SYSTEMS Evolution Series Options & systems planner manual

Baxi 100 He Installation and servicing instructions

Baxi

Baxi 100 He Installation and servicing instructions

Gabarron MATTIRA MAS18 Installation instructions and user guide

Gabarron

Gabarron MATTIRA MAS18 Installation instructions and user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.