Vuelogic Purelink XL NO-TOUCH Instruction Manual

EN
INSTALLATION GUIDE & PARTS LIST
PATENT PENDING
Please read all pages prior to installation!
XL NO-TOUCH | WALL MOUNT
WM-NT600 | WM-NT600W

Installation Guide
2
PARTS LIST
4
5
6
REF PART NAME QTY REF PART NAME QTY
XL No-Touch Mount
Interface Arms
VESA 1000mm Extension Arms
1 1
2
3
2
2
M8 x 10mm Screws
M8 Washers x 2mm
Controller Button
USB Male To Male
4 4
5
6
7
8
4
1
1
1
Universal Controller
Power Supply
Input: AC 100-240 V (50-60Hz)
Output: 12V-2A
13
8
2
7

www.purelink.de
3
INTERFACE KIT
REF PART NAME QTY REF PART NAME QTY
M6 x 16mm Screws
M6 x 25mm Screws
M6 x 40mm Screws
M8 x 16mm Screws
M8 x 25mm Screws
M8 x 40mm Screws
A 4
B 4
C 4
D
E
F
4
4
4
M8 x 5mm Spacers
M8 x 13mm Spacers
M6 Washers (for parts A-C)
M8 Washers (for parts D-F)
M8 x 25mm Spacers
G 4
H
J
K
4
4
4
I 4
ABC
DEF
GHI
JK

Installation Guide
4
INSTALLATION SAFETY INSTRUCTIONS
This mount is intended for use with at screens that do not exceed the maximum weight indicated of
135Kgs (300lbs.). Exceeding this weight limit will result in instability, causing possible injury.
Do not attempt to install this product until all instructions and warnings have been read and properly understood.
Please keep these instructions for future reference.
Please check carefully to make sure there are no missing or defective parts. Defective parts must never be used.
PureLink GmbH, its distributors and dealers are not liable or responsible for damage or injury caused by improper
installation, improper use or failure to observe these safety instructions. In such cases, all guarantees will expire.
General
PureLink GmbH recommends that only a professional AV installer or other suitably qualied persons, install this
product. Great care must always be taken during installation as AV equipment is fragile, heavy and easily damaged.
If you do not fully understand the instructions or are not sure how to install this product safely, then please consult
a professional for advice and/or to install this product for you. Failure to mount this product correctly may cause
serious injury, death or both during installation and at any time thereafter.
Do not mount any AV equipment that exceeds the specic weight limit of the product you are installing. This weight
limit will be clearly stated on each product and its packaging and will vary from product to product.
Product location
Please pay careful attention to where this product is located. Check load capacity of wall prior to installation as some
walls are not suitable for installation. Designed for indoor use, this mount is suitable for public or home installation.
If located in a public area, ensure the product is out of the immediate reach of people. If any AV equipment is to
be suspended over the likely path or location of people, then great care must be used, ensuring all equipment is
securely xed to a wooden stud, concrete block or other permanent structure.
Installing on drywall boards alone will not support the weight of most AV equipment.
When drilling holes in walls it is essential to avoid contact with electrical cables, water or gas pipes, contained within.
Use of a good quality live wire detector and hidden abscess locator is therefore recommended.
Only drill into structures when you are sure it is safe to do so.
Fixing hardware
It is highly recommended that all wall xings be used where supplied and that the purpose of all hardware is fully
understood.
In some cases, more AV equipment xing hardware will be supplied to accommodate dierent models of equipment
and set up congurations.
The installer must be satised that any supplied xing hardware is suitable for each specic installation. If any xing
screws or included hardware are deemed not sucient, for a safe installation, then please consult a professional or
your local hardware store.
Hazard limitation
When routing cables take advantage of any built-in cable management features that the product might provide and
ensure that all cables are properly routed and secure. Check to see that any moving aspect of the product can do so
unhindered by any cabling. Do not block the sensor beam area of the XL No-Touch Mount.

www.purelink.de
5
Some products have moving parts and the potential to cause injury through the crushing or trapping of ngers or
other body parts, exercise care and read all warnings.
Pay close attention to all moving parts, especially when assembling, installing and servicing. Immediately after
installation, double check that the work done is safe and secure. Double check all necessary xings are present and
suitably tightened.
It is recommended that periodic inspections (not greater than 6 months apart) of the product and its xing points are
made, to ensure safety is maintained. If in doubt, consult a professional AV installer or other suitably qualied person.
Periodic Inspection Record:
DATE INSPECTED BY LOCATION SIGNED
Installation tools required
CA PROP 65
California Prop 65 Information. Currently, we are not aware of any chemicals in this product that require warnings
under California Proposition 65. However, as the list of chemicals constantly increases, we will maintain a web page
on our internet site with any updates when they occur. For information on California Prop 65 please visit
www.p65warnings.ca.gov
Drill Drill bit
Level
Measuring tapePencil
Electric Wall Scanner

Installation Guide
6
WARNING
ES
PureLink GmbH recomienda que un instalador de audio y video profesional u otra persona debidamente cualicada
instalen este producto. PureLink GmbH, sus distribuidoresy concesionarios no se hacen cargo ni se responsabilizan
de ningún daño o lesión provocados por una instalación inapropiada. Este producto se debe montar en una estructu-
ra adecuada y se debe utilizar soportando solamentre hasta el peso máximo indicado.
FR
PureLink GmbH recommande de coner I’installation de ce produit à un installateur AV professionnel ou à une autre
personne dûment qualiée. PureLink GmbH, ses distributeurs et ses revendeurs ne sauraient être tenus resounsables
de tout dégât ou de toute blessure résultant d’ une installation incorrecte. Ce produit doit être monté sur un support
approprité et utilisé dans la limite du poids maximum indiqué.
DE
PureLink GmbH empehlt, dass dieses Produkt durch einen qualizierten AV-Techniker oder eine andere Person
mit geeigneter Qualikation installiert wird. PureLink GmbH, ihre Distributoren und Händler können nicht für durch
fehlerhafte Montage verursachte Beschädigung oder Verletzung haftbar bzw. verantwortlich gemacht werden. Dieses
Produkt muss auf eine geeignetem Untergrund montiert werden und darf nur bis zum angegebenen Höchstgewicht
verwendet werden.
IT
PureLink GmbH consiglia di adare I’installazione di questo prodotto a un installatore specializzato o ad
altra persona adeguatamente qualicata. PureLink GmbH i suoi distributori e rivenditori non accettano alcuna
responsabilità nei riguardi di eventuali danni o infortuni causati da un’errata installazione. Questo prodotto deve
essere ssato a una struttura idonea e utilizzato unicamente sino al peso massimo indicato.
NL
PureLink GmbH adviseert om dit product te laten installeren door een professionele AV-installateur of andere hier-
voor gekwaliceerde persoon. PureLink GmbH haar distributeurs en dealers zijn niet aansprakelijk of verantwoorde-
lijk voor schade of letsel die is veroorzaakt door onoordeelkundige installatie. Dit product moet worden gemonteerd
aan een geschikte constructie, waarbij het aangegeven maximum gewicht niet mag worden overschreden.
PT
A PureLink GmbH recomenda que a instalação deste produto seja efectuada por um instalador de AV instalador de
AV prossional ou outra pessoa devidamente habilitada. A PureLink GmbH e os seus distribuidores e concessionários
não são responsáveis por danos ou lesões causados por uma instalação incorrecta. Este produto tem de ser montado
numa estrutura adequada e utilizado somente até ao peso máximo indicado.
PL
Firma PureLink GmbH zaleca, aby ten produkt był instalowany przez profesjonalnych instalatorów AV lub inny odpo-
wiednio przeszkolony personel. Firma PureLink GmbH, jej dystrybutorzy i dealerzy nie ponoszą odpowiedzialności
za uszkodzenia lub obrażenia ciała powstałe w wyniku nieprawidowej instalacji. Niniejszy produkt musi być zamon-
towany na odpowiedniej powierzchni, a podczas u żytkowania nie wolno przekraczać podanego maksymalnego
obciążenia.
CS
Společnost PureLink GmbH doporučuje provést instalaci tohoto produktu instalátora AV či jinak způsobilé osoby.
Společnost PureLink GmbH, její distributoři a prodejci nenesou prostřednictvím odborného odpov ědnost za škody
nebo zranění způsobená nevhodnou instalací. Tento výrobek je nutno umístit do vhodné konstrukce a používat jen
po uvedenou maximákní výšku.
RU
Warranty period : 3 Years
This PureLink product, delivered new, in the original carton to the original consumer purchaser, is warranted by
PureLink against manufacturing defects in materials and workmanship for the warranty period above. This warranty
begins on the original date of purchase. To receive warranty service, the purchaser must contact PureLink for prob-
lem determination and service procedures. Warranty service can only be performed by a PureLink authorized service
centre. The original dated bill of sale must be presented upon request as proof of purchase to PureLink authorized
service centre.
PureLink GmbH
PureLink GmbH

www.purelink.de
7
II
Note: Walls are built from dierent materials and require dierent wall bolts for best
performance and safety. Please select suitable xings or consult an expert for guidance.
General recommendations
Start from the bottom corner (small) or central
screen (large) of the video wall configuration.
Height of screen determines center to center distance
for next vertical mount location.
Width of screen determines center to center distance
for next horizontal mount location.
Build Horizontallly first then add rows until all rows are
completed.
3 3 4
11
1
22
2
1
Align the one common border
before mounting the next screen
Align the two common borders
before mounting the next screen
I
III
Check the wall structure being mounted to. Use a level to ensure the wall is flat and note areas of concern. Use
washers, shims or spacers between the wall and the mount to create a flat surface for mounting. A flat mount will
make adjustments much easier and faster when aligning screens.
Note: The PureLink GmbH XL No-Touch Mount is ONLY suitable for installation perpendicular to the floor in portrait or
landscape orientation. It is NOT suitable for angled or overhead mounting. For angled mounting please see Soft-Touch
Mount on www.purelink.de
Installation guide (for single screens go to Page 8)
For video walls, we suggest starting from a corner. Begin at the bottom left corner and add screens row by row,
aligning them as you go. Before installation, make sure to center the depth and lateral micro-adjustments. This will
make aligning the screens quicker and easier. If you’re working with a larger video wall, it’s recommended to start with
the center screens.video walls it is advised to start with the center screens.
IV

Installation Guide
8
INSTALLATION INSTRUCTIONS
Step 1 Unpack and check all parts
Open top and bottom handwheels on Interface Arms (closed for shipment).
Check depth and lateral adjustment knobs are centered in adjustment range.
Open top and bottom
Handwheels
Control Box
Interface Arms Extension Arms
Keep area below
control-box clear
(light-beam)
Center
Center
Measure, mark and drill holes
• Use level to check alignment.
• Use an Electric Wall Scanner to locate electrical wires to drill holes in the wall safely
• Tighten all wall bolts (6 pcs recommened).
• Do not hang screen on mount (until step 7).
Step 2
Wall fixing holes
Level
Use at least 2 wall bolts (3 recommended) at
Top and 2 wall bolts bottom of mount. Heavier
screen should have 3 bolts at the top
Electric Wall Scanner

www.purelink.de
9
Step 3
Universal
Controller Universal Controller
Connect the power supply to the control box and electrical socket
Only use the power supply provided. If not possible, contact PureLink GmbH to ensure the appropriate
replacement is used. Note: The use of 3rd party power supplies will void warranty!
Note: Once the screens are installed, aligned and closed, to prevent accidental movement of
the Mount or electrical interference/damage, ensure that Mount-dedicated power strips or
power supply is turned o/unplugged, until next service appointment.
Connect the power supply
to the control box
Step 4
150 mm
6 ’’
Light-Beam
The PureLink XL No-Touch Mount, allows the screen to move OUT and IN, without the need to touch the screen.
Position the control wand approximately 150 mm/6” to the right of center of the mount (see below). The mount
will slowly start to move OUT.
How to use Universal Controller to operate the Mount

Installation Guide
10
Move Universal Controller with the Mounts
Movement
Once the Universal Controller is positioned below the light
beam, the Mount will start moving. To keep the Mount
moving, make sure you sync the Universal Controller with
this movement. If you remove the controller from the right
spot, the Mount will STOP.
To STOP the Mount, remove the Universal Con-
troller from the light beam
The Mount will only move when the Universal Controller is
in the light beam.
Once removed from light beam, the Mount will STOP
To CHANGE the Mounts DIRECTION, quickly
SWIPE the Universal Controller underneath the
light beam
You will hear a signal:
2 beeps: move IN
3 beeps: move OUT
After hearing the signal, position the Universal Controller
again below the light beam to move
the Mount in the chosen direction.
When fully closed or open, it will not beep as it can only
move one direction.

www.purelink.de
11
Position of the light beam
X = Depth of the screen
Y = 75mm
Z = X + Y + 10mm
Z* = Depth controller needs to be from front of screen to
operate the Mount.
* some users mark the controller to show this
distance for easier use
Step 5
For VESA 1000x600 Landscape For VESA 600x1000 Portrait
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
TV SCREEN BACK
Attach the Interface Arms to the screen (Landscape or Portrait)
The interface arms fit from VESA 300 x 300mm through 800 x 600mm.
For 900 or 1000 mm VESA size, use supplied extension arms.
X Y
Z

Installation Guide
12
Step 7 Make Adjustment (See below)
A : Height adjustment
B: Corner depth adjustment
C: Lateral macro adjust
loosened for any adjustments)
Step 6 Connect screen to Mount
At slight angle, hook arms onto top of frame, then flatten screen onto Mount base
until it clicks into position.
Height adjustment
Lateral Smart-
Lock
Lateral micro
adjustment
Tighten to secure (last step)
Corner depth
adjustment
A
C
BE
D
D: Lateral micro adjustment
E: Locking handwheels
(must be loosened for any adjustments)

www.purelink.de
13
CD
Lateral Smart-Lock
1) unlock lateral Smart-Lock,
2) slide screen into position,
3) slide Smart-Lock to interface arm,
4) lock Smart-Lock.
1) After Smart-Lock is in position,
the lateral micro adjustment can be used.
Lateral micro adjustment
Each time you add a screen to the video wall make needed adjustments.
*Note: Locking handwheels must be loosened before any adjustments can be made.
Once all adjustments are done, the locking handwheels can be tightened.
E
Locking handwheels

Installation Guide
14
B
Corner depth
adjustment
A
Height adjustment

www.purelink.de
15
RECESS FLAT SCREEN INSTALLATION
Step 1 Make a rectangular hole on the wall using the dimensions of the chosen screen by fol-
lowing the instructions below.
• Please ensure minimum gaps between the screen and four edges of the recessed box is 2mm and that
corners and four angles are 90 degrees.
• Must use Electric Wall Scanner to locate the position of electric wires before drilling into the wall.
The hole on the wall (LxHxD)
L = Ls + X mm
H = Hs + Y mm
D = Ds + 100 mm
X, Y: Gap each corner
The mount
The screen (Ls x Hs x Ds)
Ls = Length
Hs = Height
Ds = Depth
The dimension of rectangular holes on the wall need to be created based on the screen’s dimensions.
Note: Some screen manufacturers do not put the VESA holes at the center of the screen backside. Therefore,
you should locate the position of back wall plate and mark the drill holes with the following instruction.
Top of screen
Bottom of screen
Ls
Hs
Ds
H1
H3
H2
Y
X
Wall Hole
D
H
L
Center of wall hole
100
Mount space

Installation Guide
16
Step 2 Locate the mount’s back wall plate by using tape ruler and bubble level.
Important: The VESA holes position of a monitor is pre-de ned by the manufacturer.
• Must use Electric Wall Scanner to locate the position of electric wires before drilling into the wall.
2.1 If H1=H3, the position of the mount will be in the middle of the recessed box (H1, H3: See on pages 15).
• Calculate and mark the retangular box for the position of back wall plate by 3 dimensions as bellow A1, A2, B
(Size of back wall plate HxW=468x480 mm) => Use measuring tape to con rm 3 dimension A1, A2, B are right
• Put the mount on the wall hole and mark the drill holes
• Hang the screen and adjustment to t with the wall hole (see pages 11-14).
Level
Top
Bottom
L
H
468 mm
480 mm
Center of wall hole=Center of screen
Note:
• Use at least 2 wall bolts (3
recommended) at Top and 2 wall bolts
bottom of mount. Heavier screen
should have 3 bolts at the top
• Measure, mark and drill holes
• Use level to check alignment.
• Use an Electric Wall Scanner to locate the
electrical wire if you want to drill a hole in
the wall.
• Tighten all wall bolts (6 pcs recommened).
A1=(H-468)/2 mm
B=(L-480)/2 mm B=(L-480)/2 mm
A2=(H-468)/2 mm
Closed OpenedFront
Top
Note: The picture above show only back wall plate for easy understanding, in fact there will be
the whole mount

www.purelink.de
17
2.2 If H1<H3, the center of mount will be higher than the center of the recessed box.(H1, H3: See on pages 15).
• Calculate and mark the retangular box for the position of back wall plate by 3 dimensions as bellow A1, A2, B (Size
of back wall plate HxW=468x480 mm) => Use measuring tape to con rm 3 dimension A1, A2, B are right
• Put the mount on the wall hole and mark the drill holes
• Hang the screen and adjustment to fit with the wall hole (see pages 11-14).
Top
Bottom
L
H
468 mm
480 mm
Center of
wall hole
Note:
• Use at least 2 wall bolts (3
recommended) at Top and 2 wall bolts
bottom of mount. Heavier screen
should have 3 bolts at the top
• Measure, mark and drill holes
• Use level to check alignment.
• Use an Electric Wall Scanner to locate
the electrical wire if you want to drill a
hole in the wall.
• Tighten all wall bolts (6 pcs
recommened).
A1=(H-468)/2 - (H3-H1) mm
B=(L-480)/2 mm B=(L-480)/2 mm
A2=(H-468)/2
+ (H3-H1) mm
Closed Opened
Center of screen
H3-H1
Front
Top
Note: The picture above show only back wall plate for easy understanding, in fact there will be
the whole mount

Installation Guide
18
2.3 If H1<H3, the center of mount will be lower than the center of the recessed box.(H1, H3: See on pages 15).
• Calculate and mark the retangular box for the position of back wall plate by 3 dimensions as bellow A1, A2, B
(Size of back wall plate HxW=468x480 mm) => Use measuring tape to con rm 3 dimension A1, A2, B are right
• Put the mount on the wall hole and mark the drill holes
• Hang the screen and adjustment to t with the wall hole (see pages 11-14).
Top
Bottom
L
H
468 mm
480 mm
Center
of wall hole
Note:
• Use at least 2 wall bolts (3
recommended) at Top and 2 wall bolts
bottom of mount. Heavier screen should
have 3 bolts at the top
• Measure, mark and drill holes
• Use level to check alignment.
• Use an Electric Wall Scanner to locate the
electrical wire if you want to drill a hole in
the wall.
• Tighten all wall bolts (6 pcs recommened).
A1=(H-468)/2 + (H3-H1) mm
B=(L-480)/2 mm B=(L-480)/2 mm
A2=(H-468)/2-(H3-H1) mm
ClosedFront
Top
Opened
Center of sceen
H3-H1
Note: The picture above show only back wall plate for easy understanding, in fact there will be
the whole mount

www.purelink.de
19
CONNECTIVITY
Control box
There are several different ways to control the mount
1. Universal Controller
2. USB
3. Wifi
4. Ethernet
5. Bluetooth

Installation Guide
20
OUT/IN PORT
Secure the USB
cable in place by
tightening it to the
hole panel.
1. Universal Controller
To see how to control the mount using Universal Controller, go to pages 9-11.
2. USB
There are 2 ways to control the mount via USB Port (USB button and PC via USB port)
2.1 USB Button
• Plug USB connector into the right position (OUT/IN)
• Do cable management by using the hole panel
• Press the buttom to move the screen out/in
Important:
• Don’t put the cable into the X-arm movement at center.
• Secure the USB cable in place on both sides
Note: How to wire the USB cable ?
- Don’t use the 5V (Red) wire
WHITE
GREEN
GND (BLACK)
WHITE
GREEN
5V (RED), Don’t use red wire (Remove)
GND (BLACK)
IN OUT
This manual suits for next models
2
Table of contents
Other Vuelogic Rack & Stand manuals