VWR VisiCamB5 User manual

INSTRUCTION MANUAL
Version: 1.0
Issued: 07, 02, 2020
Model European Catalogue Number
VisiCamB5 630-2957
VisiCamP6 630-2958
OPTKC-P20CC 630-2959
OPTKC-PF 630-2960
VWR
USB cameras
1/2

2
Table of Contents
Legal Address of Manufacturer
Country of origin: ITALY
Europe
VWR International bvba
Researchpark Haasrode 2020
Geldenaaksebaan 464
B-3001 Leuven
+ 32 16 385011
http://be.vwr.com
1. Warning 3
2. Safety Information 3
3. Package Contents 3
4. Unpacking 4
5. Intended use 4
6. Symbols and conventions 4
7. Overview 4
7.1 VisiCamB5 4
7.2 VisiCamP6 / OPTKC-PF 5
7.3 OPTKC-P20CC 5
8. Camera Installation and Settings 6
8.1 Assembling on microscope 6
8.1.1 Connection to trinocular port using focusable “C” mount adapter 6
8.1.2 Connection to trinocular port using projection lens 6
8.1.3 Connection to binocular or monocular head 7
8.2 Parfocality adjustment 8
8.2.1 Using a biological microscope 8
8.2.2 Using a stereomicroscope with “C” mount adapter 8
8.2.3 Using a stereomicroscope with projection lens 9
8.3 Connecting camera to PC 9
8.3.1 Only for cooled versions 9
8.4 Use of drainage tube (cooled versions) 10
9. Use of camera 10
10. Micrometric Slide VWR005 11
11. Repair and maintenance 12
12. Technical service 12
13. Warranty 12
14. Compliance with local laws and regulations 12
Disposal 13

3
1. Warning
This device is a scientic precision instrument designed to last for many years with a minimum of maintenance.
It is built to high optical and mechanical standards and to withstand daily use.
We remind you that this manual contains important information on safety and maintenance, and that it must
therefore be made accessible to the instrument users.
We decline any responsibility deriving from incorrect instrument use uses that does not comply with this manual
2. Safety Information
Avoiding Electrical Shock
Before plugging in the power supply, make sure that the supplying voltage of your region matches with the opera-
tion voltage of the equipment and that the lamp switch is in o-position.
Users should observe all safety regulations of the region. The equipment has acquired the CE safety label. How-
ever, users do have full responsibility to use this equipment safely.
Please follow the guidelines below, and read this manual in its entirety to ensure safe operation of the unit.
3. Package Contents
VisiCamB5
DESCRIPTION QUANTITY
Camera 1
USB2.0 cable 1
0,5X projection lens 1
Reduction ring 30 mm 1
Reduction ring 30.5 mm 1
Micrometric slide 1
VisiCamP6 / OPTKC-PF
DESCRIPTION QUANTITY
Camera 1
USB3.0 cable 1
Micrometric slide 1
OPTKC-P20CC
DESCRIPTION QUANTITY
Camera 1
USB3.0 cable 1
Draining tube 1
Power supply 1
Schuko power cord 1
UK power cord 1
Swiss power cord 1
Micrometric slide 1

4
4. Unpacking
The camera is housed in a moulded Styrofoam container. Remove the tape from the edge of the container and
lift the top half of the container. Take some care to avoid that the optical items fall out and get damaged.
5. Intended use
For research use only. Not intended for any animal or human therapeutic or diagnostic use.
6. Symbols and conventions
The following chart is an illustrated glossary of the symbols that are used in this manual.
CAUTION
This symbol Indicates a potential risk and alerts you to proceed with caution
7. Overview
7.1 VisiCamB5
USB 2.0
CABLE SOCKET
“C” MOUNT

5
7.2 VisiCamP6 / OPTKC-PF
7.3 OPTKC-P20CC
USB 3.0 CABLE SOCKET
(BACK OF THE CAMERA)
“C” MOUNT
EXTERNAL POWER
SUPPLY SOCKET
USB2.0
CABLE SOCKET
USB3.0
CABLE SOCKET
OPERATION LED

6
8. Camera Installation and Settings
FFig. 1ig. 1
FFig. 2ig. 2
FFig. 3ig. 3
FFig. 4ig. 4
8.1 Assembling on microscope
8.1.1 Connection to trinocular port using focusable “C” mount adapter
1. Remove the dust cover from camera and from “C”
mount adapter.
2. Screw the “C” mount adapter to the camera’s
thread. (Fig. 1)
3. Loosen the clamping screw on the trinocular port
of the microscope, remove the dust cover and
install the camera ”C” mount unit previously as-
sembled. (Fig. 2)
4. Tighten the clamping screw rmly. (Fig. 3)
8.1.2 Connection to trinocular port using projection lens
1. Remove the dust cover from camera and from
projection lens.
2. Screw the projection lens to the camera’s thread.
(Fig. 4)

7
• Installing on biological microscopes
3. Insert the nal part of the projection lens into the
empty hole of the photo tube. (Fig. 5)
• Installing on stereomicroscopes
4. Insert the nal part of the projection lens into the
empty hole of the photo tube. (Fig. 6)
FFig. 5ig. 5
FFig. 6ig. 6
8.1.3 Connection to binocular or monocular head
• Any monocular or binocular microscope / ster-
eomicroscope.
1. Remove the dust cover from camera and from
projection lens.
2. Screw the projection lens to the camera’s thread.
(Fig. 7)
3. Remove one eyepiece from the observation head.
(Fig. 8)
FFig. 8ig. 8
FFig. 7ig. 7

8
4. Insert the nal part of the projection lens into the
empty eyepiece sleeve. (Fig. 9)
5. In case of eyepiece sleeve with diameter 30 or
30.5 mm use the adapter rings. (Fig. 10)
8.2 Parfocality adjustment
In order to have the same focus when observing the
specimen through the eyepieces and on the screen/
monitor, please check that the microscope is properly
installed and follow the instructions below.
8.2.1 Using a biological microscope
1. Use a low power objective and focus the speci-
men.
2. Switch to the highest dry objective available on
the microscope (40x or 60x) and focus the speci-
men again.
3. Turn on the live-view on the camera, without
changing the focus on the microscope.
4. While observing the image on the screen/monitor,
adjust the focus by turning the knurled knob on
the C-mount adapter. (Fig. 11)
FFig. 9ig. 9
FFig. 10ig. 10
8.2.2 Using a stereomicroscope with “C” mount adapter
1. Use a low power magnication and focus the
specimen.
2. Reach the highest magnication available us-
ing the zoom knob and then focus the specimen
again.
3. Turn on the live-view on the camera, without
changing the focus on the microscope.
4. While observing the image on the screen/monitor,
adjust the focus by turning the knurled knob on
the C-mount adapter. (Fig. 11)
FFig. 11ig. 11

9
8.2.3 Using a stereomicroscope with projection lens
1. Use a low power magnication and focus the
specimen.
2. Reach the highest magnication available us-
ing the zoom knob and then focus the specimen
again.
3. Turn on the live-view on the camera, without
changing the focus on the microscope.
4. While observing the image on the screen/monitor,
unscrew the xing knob ① of the trinocular port
(Fig. 12) and move up or down the movable part
of the adapter ② until the focus is achieved on
the camera. (Fig. 13)
5. Lock the xing knob ①. (Fig. 12)
The proper parfocality adjustment is obtained when
the same focus is reached while looking into the eye-
pieces and on the screen/monitor.
8.3 Connecting camera to PC
1. Connect one terminal of the USB cable to the
camera connector and the other terminal to a
USB port on the computer. (Fig. 14)
• NOTE: USB3.0 cameras can be connected to a
USB2.0 port. The camera will operate normally,
with some limitations due to improper power sup-
ply to the camera.
• The SW in any case will warn that the USB3.0
camera works in 2.0 mode indicating next to the
camera name “(USB2.0)”
8.3.1 Only for cooled versions
Connect the supplied power adapter to the connec-
tor ①to power the camera cooling system. (Fig. 15)
FFig. 12ig. 12
①
②
FFig. 13ig. 13
FFig. 14ig. 14
USB2.0 USB3.0
FFig. 15ig. 15
①

10
8.4 Use of drainage tube (cooled versions)
• NOTE: Use the drainage tube only when strict-
ly necessary.
Cooled cameras sometimes create condensation in-
side the camera body during normal use.
This condensation may interfere with the correct cre-
ation of the image on the sensor.
To remove any condensation, act as follows.
1. Disconnect all cables from the camera (power
supply and USB).
2. Using a at screwdriver, unscrew the screw ①on
the left side of the camera. (Fig. 16)
3. Immediately screw the drainage tube ②into the
empty hole. (Fig. 17)
• If the camera is connected to a USB cable or
power supply during this operation, there is
a risk that the electrostatic charge will attract
dirt and dust that will settle on the sensor.
• Periodically empty the drainage tube repeating in
reverse order the operations described above.
FFig. 16ig. 16
①
FFig. 17ig. 17
②
9. Use of camera
The camera is driven by the software PROVIEW.
You have to run the setup.exe le for the software installation.
At the end of the installation it is possible to start the software.
• NOTE: no driver installation is required for the cameras. The software setup procedure automatically
installs all the needed drivers for the correct operation of the camera.
The software’s User Manual is available in PDF format within the application itself and can be opened using the
“F1” function key.
You must have Acrobat Reader installed to view the manual.
The manual contains all the operating instructions for using the camera and for the various functions of the soft-
ware.

11
10. Micrometric Slide VWR005
Micrometric slide, 26x76mm, with 2 scales
(1mm/100div. for biological microscopes / 10mm/100div. for stereomicroscopes)
For biological microscopes calibration
1 DIV=0.01mm
For stereo microscopes calibration
1 DIV=0.1mm
0 1 2 3 4 5 6 7 8 9 10

12
11. Repair and maintenance
Microscopy environment
This microscope is recommended to be used in a clean, dry and shock free environment with a temperature of
0-40°C and a maximum relative humidity of 85 % (non condensing). Use a dehumidier if needed.
To think about when and after using the microscope
The microscope should always be kept vertically when moving it and be careful so that no moving parts, such as
the eyepieces, fall out. Never mishandle or impose unnecessary force on the microscope.
Never attempt to service the microscope yourself.
After use, turn o the light immediately, cover the microscope with the included dust-cover, and keep it in a dry
and clean place.
Electrical safety precautions
Before plugging in the power supply, make sure that the supplying voltage of your region matches with the opera-
tion voltage of the equipment and that the lamp switch is in o-position.
Users should observe all safety regulations of the region. The equipment has acquired the CE safety label. How-
ever, users do have full responsibility to use this equipment safely.
Cleaning the optics
If the optical parts need to be cleaned try rst to: use compressed air. If that is not sucient: use a soft lint-free
piece of cloth with water and a mild detergent. And as a nal option: use the piece of cloth moistened with a 3:7
mixture of ethanol and ether.
Note: ethanol and ether are highly ammable liquids. Do not use them near a heat source, near sparks
or near electric equipment. Use these chemicals in a well ventilated room.
Remember to never wipe the surface of any optical items with your hands. Fingerprints can damage the optics.
Do not disassemble objectives or eyepieces in attempt to clean them.
For the best results, use the VWR cleaning kit.
If you need to send the microscope to manufacturer for maintenance, please use the original packaging.
12. Technical service
Web Resources
Visit the VWR’s website at www.vwr.com for:
• Complete technical service contact information
• Access to VWR’s Online Catalogue, and information about accessories and related products
• Additional product information and special oers
Contact us For information or technical assistance contact your local VWR representative or visit www.vwr.
com.
13. Warranty
VWR International warrants that this product will be free from defects in material and workmanship for a period
of ve (5) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, replace, or
refund the purchase price of this product to the customer, provided it is returned during the warranty period. This
warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication, or from
ordinary wear and tear. If the required maintenance and inspection services are not performed according to the
manuals and any local regulations, such warranty turns invalid, except to the extent, the defect of the product is
not due to such non-performance.
Items being returned must be insured by the customer against possible damage or loss. This warranty shall be
limited to the aforementioned remedies. IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU
OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY.
14. Compliance with local laws and regulations
The customer is responsible for applying for and obtaining the necessary regulatory approvals or other authori-
zations necessary to run or use the Product in its local environment. VWR will not be held liable for any related
omission or for not obtaining the required approval or authorization, unless any refusal is due to a defect of the
product.

13
Disposal
This equipment is marked with the crossed out wheeled bin symbol to indicate that this equipment must not be
disposed of with unsorted waste.
Instead it is your responsibility to correctly dispose of your equipment the end of its life cycle by handling it over
to an authorized facility for separate collection and recycling. It is also your responsibility to decontaminate the
equipment in case of biological, chemical and/or radiological contamination, so as to protect from health hazards
the persons involved in the disposal and recycling of the equipment.
For more information about where you can drop o your waste equipment, please contact your local dealer from
whom you originally purchased this equipment.
By doing so, you will help to conserve natural and environmental resources and you will ensure that your equip-
ment is recycled in a manner that protects human health.
Thank you

14

15

16
Australia
VWR International, Pty Ltd.
Unit 1/31 Archimedes Place
Murarrie, Queensland 4172
Tel.: 1300 727 696
Fax: 1300 135 123
Austria
VWR International GmbH
Graumanngasse 7
1150 Vienna
Tel.: +43 1 97 002 0
Fax: +43 1 97 002 600
E-mail: [email protected].com
Belgium
VWR International bvba
Researchpark Haasrode 2020
Geldenaaksebaan 464
3001 Leuven
Tel.: 016 385 011
Fax: 016 385 385
E-mail: [email protected].com
China
VWR International China Co., Ltd
Rm.219, 2100 Dongming Road
Pudong New District
Shanghai 200123
Tel.: +86-21-5898 6888
Fax: +86-21-5855 8801
E-mail: info_china@vwr.com
Czech Republic
VWR International s. r. o.
Veetee Business Park
Pražská 442
CZ - 281 67 Stříbrná Skalice
Tel.: +420 321 570 321
Fax: +420 321 570 320
E-mail: [email protected].com
Denmark
VWR - Bie & Berntsen
Transformervej 8
2730 Herlev
Tel.: 43 86 87 88
Fax: 43 86 87 90
E-mail: [email protected].com
Finland
VWR International Oy
Valimotie 9
00380 Helsinki
Tel.: 09 80 45 51
Fax: 09 80 45 52 00
E-mail: info@ .vwr.com
France
VWR International S.A.S.
Le Périgares – Bâtiment B
201, rue Carnot
94126 Fontenay-sous-Bois cedex
Tel.: 0 825 02 30 30 (0,15 € TTC/min)
Fax: 0 825 02 30 35 (0,15 € TTC/min)
E-mail: info@fr.vwr.com
Germany
VWR International GmbH
Hilpertstraße 20a
D - 64295 Darmstadt
Freecall: 0800 702 00 07
Fax: 0180 570 22 22*
Email: [email protected].com
*0,14 €/Min. aus d. dt. Festnetz
Hungary
VWR International Kft.
Simon László u. 4.
4034 Debrecen
Tel.: (52) 521-130
Fax: (52) 470-069
E-mail: [email protected].com
India
VWR Lab Products Private Limited
135/12, Brigade Towers, 2nd Floor
Front wing, Brigade Road,
Bengaluru, India – 560 025
Tel.: +91-80-41117125/26 (Bengaluru)
Tel.: +91-2522-647911/922 (Mumbai)
Fax: +91-80-41117120
E-mail: vwr_india@vwr.com
Ireland / Northern Ireland
VWR International Ltd /
VWR International (Northern Ireland) Ltd
Orion Business Campus
Northwest Business Park
Ballycoolin
Dublin 15
Tel.: 01 88 22 222
Fax: 01 88 22 333
E-mail: [email protected].com
Italy
VWR International PBI S.r.l.
Via San Giusto 85
20153 Milano (MI)
Tel.: 02-3320311/02-487791
Fax: 800 152999/02-40090010
E-mail: [email protected].com
The Netherlands
VWR International B.V.
Postbus 8198
1005 AD Amsterdam
Tel.: 020 4808 400
Fax: 020 4808 480
E-mail: [email protected].com
New Zealand
Global Science - A VWR Company
241 Bush Road
Albany 0632, Auckland
Tel.: 0800 734 100
Fax: 0800 999 002
E-mail: [email protected]
Norway
VWR International AS
Haavard Martinsens vei 30
0978 Oslo
Tel.: 02290
Fax: 815 00 940
E-mail: [email protected].com
Poland
VWR International Sp. z o.o.
Limbowa 5
80-175 Gdansk
Tel.: 058 32 38 200 do 204
Fax. 058 32 38 205
E-mail: [email protected].com
Portugal
VWR International -
Material de Laboratório, Lda
Edifício Neopark
Av. Tomás Ribeiro, 43- 3 D
2790-221 Carnaxide
Tel.: 21 3600 770
Fax: 21 3600 798/9
E-mail: [email protected].com
Singapore
VWR Singapore Pte Ltd
18 Gul Drive
Singapore 629468
Tel.: +65 6505 0760
Fax: +65 6264 3780
E-mail: [email protected].com
Spain
VWR International Eurolab S.L.
C/ Tecnología 5-17
A-7 Llinars Park
08450 - Llinars del Vallès
Barcelona
Tel.: 902 222 897
Fax: 902 430 657
E-mail: [email protected].com
Sweden
VWR International AB
Fagerstagatan 18a
163 94 Stockholm
Tel.: 08 621 34 00
Fax: 08 621 34 66
E-mail: [email protected].com
Switzerland
VWR International GmbH
Lerzenstrasse 16/18
8953 Dietikon
Tel.: 044 745 13 13
Fax: 044 745 13 10
E-mail: [email protected].com
Turkey
Pro Lab Laboratuar Teknolojileri Ltd.Şti.
a VWR International Company
Orta Mah. Cemal Gürsel Caddesi
Ördekcioglu Işmerkezi No.32/1
34896 Pendik - Istanbul
Tel.: +90216 598 2900
Fax: +90216 598 2907
UK
VWR International Ltd
Customer Service Centre
Hunter Boulevard - Magna Park
Lutterworth
Leicestershire
LE17 4XN
Tel.: 0800 22 33 44
Fax: 01455 55 85 86
E-mail: [email protected].com
GO TO VWR.COM FOR THE
LATEST NEWS, SPECIAL OFFERS
AND DETAILS OF YOUR LOCAL
VWR DISTRIBUTOR
This manual suits for next models
7