GETTING STARTED
Table of Contents
fGetting Started Page 2
fWCS Preparation Page 3
fPlumbing and Mechanical Page 4
fWarmsource Specification Page 5
fWarmsource Preparation Page 7
fWarmsource Installation Page 8
fWarmsource Flex Specification Page 9
fWarmsource Flex Preparation Page 11
fWarmsource Flex Installation Page 12
fFilling and Purging Page 13
fConstruction Mode Page 14
fManifold Cabinet Page 15
fThermostats Page 16
fAir Conditioning Page 17
fTesting the System Page 18
Installation Tips
1The Warmboard Comfort System (WCS) requires
tubing loops to be installed according to our
documentation in order for the system to operate
correctly. DO NOT revise tubing loops or zones
without first consulting Warmboard Inc.
2WCS MUST be installed by a licensed general
contractor, heating professional or plumber.
Failure to use a properly licensed installer, failure to
use the required parts and components and/or any
deviation from these installation guidelines will
void any product warranty.
3WCS uses proprietary, plug-and-play controls
including thermostats, Manifold Controllers and
a Smart Reset Controller. These items CANNOT
be exchanged with alternative products.
4Electrical components require 110 volt wiring.
5All devices communicate via a pre-configured,
wireless network – there’s no need for additional
wiring or knowledge of networking equipment.
6Warmsource boilers require no programming or
commissioning, and water temperatures are
calibrated using our Indoor Reset algorithm.
7DO NOT adjust any boiler settings without
consulting Warmboard. Changes made through
the boiler’s LCD screen will impact system
performance and operation.
8When plumbing for the system is complete,
operate WCS in “Construction Mode” (pg. 14).
This feature allows installers to test the boiler
and flow rates, acclimate building products and
provide heat on cold job sites.
9The use of a combustion analyzer is required to
calibrate safe carbon monoxide readings. Failure
to do so could result in injury or death (pg. 14).
10 Disable Construction Mode before installing
actuators, Manifold Controller(s) and thermostats.
WARNING
Breathing Hazard – Carbon Monoxide Gas
Breathing carbon monoxide can cause brain damage
or death. Always read and understand instruction manual.
Do not operate heater if ood damaged
Install vent system in accordance with local
codes and manufacturers instructions
Do not place chemical vapor emitting
products near the unit
Per NFPA 720, carbon monoxide detectors
should be installed outside each sleeping area
Never operate the heater unless it is vented
to the outdoors
Analyze the entire vent system to make sure
condensate will not become trapped in a
section of vent pipe and therefore reduce
the open cross sectional area of the vent
Follow all instructions and complete the
Lochnivar Noble registration card.
Review this guide and the supplied working
drawings (including the floor plan dimensions)
DO NOT revise tubing loops or zones without
consulting Warmboard. Field changes will impact
operation of the system.