12 warmhaus.co.uk
2.5. TROUBLESHOOTING
Error
Code Description of the Error Malfunction Probable Cause Solution(s)
E 01 Interventon of exhaust
Thermostat
Boler does not work, E01 error
code flashng on the screen
> Flue Sensor faulty 1) Reset & Restart boler
2) Call for authorsed servce
E 02 Low water pressure n the
system/system parameter
wrongly setted
Boler does not work, E02 error
code flashng on the screen
> Water pressure n the boler
too low
1) Fll the boler 1,2-1,5 bar accordng to manual
2) Check f the system pressure 1,2 - 1,5 bar from the LCD Screen
3) Reset & Restart boler
4) If problem persst Call for authorsed servce
E 03 Hgh water pressure n the
system
Boler does not work, E03 error
code flashng on the screen
> Hgh Water pressure n the
boler ( > 2,8 bar )
1) Frst check the fllng tap of the boler and make sure t s
closed.
2) Durng boler operaton, the safety valve may contnue to dran
water so make sure that t s connected to a dran lne.
3) If your plumbng lne has a dran cock; frst turn the boler o
and let the pressure drop to 1-1.5 bar, then swtch t on agan.
4) If the pressure ncrease occurs agan, call an authorsed
servce.
E 05 Central heatng FLOW
temperature sensor faulty
Boler does not work, E05 error
code flashng on the screen
> Central heatng FLOW
temperature sensor faulty
1) Reset & Restart the boler
2) Call for authorsed servce f problem perssts
E 06 No gnton Boler does not work, E06
error code flashng on the
screen
> Gas supply falure 1) Reset & Restart the boler
2) Check boler central heatng valves are open f they are closed
open all
3) Check all radator valves are open f they are closed. Mnmum
3 meters of radator must be open
4) RESET boler and check f problem s resolved.
5) Call for authorsed servce
E 07 Safety thermostat nterventon Boler does not work, E07 error
code flashng on the screen
> Lack of water n the system
> Pump blockage
> Pump falure
> Pump harness
> Installaton blockage
1) RESET boler check f problem s resolved
2) Check boler central heatng valves are open f they are closed
open all
3) Check all radator valves are open f they are closed. Mnmum
3 meters of radator must be open
4) RESET boler and check f problem s resolved
5) Call for authorsed servce
E 08 Flame crcut falure False flame sgnal from
combuston or electrode
> Condensate Syphon blocked
> Electronc board
1) Call for authorsed servce
E 09 No water crculaton
n the system
Boler does not work, E09
error code flashng on the
screen
> Lack of water n the system
> Pump blockage
> Pump falure
> Pump harness
> Installaton blockage
1) RESET boler at frst check f problem s resolved.
2) Check boler central heatng valves are open f they are closed
open all
3) Check all radator valves are open f they are closed. Mnmum
3 meters of radator must be open
4) RESET boler and check f problem s resolved
5) Call for authorsed servce
E 11 Gas valve modulator
dsconnected
Boler does not work, E11 error
code flashng on the screen
> Gas valve harness 1) Call for authorsed servce
2) Check gas valve between board and gas valve
E 13 Exhaust temperature probe
over-temperature alarm
Boler does not work, E13 error
code flashng on the screen
> Over temperature flue gas
outlet
value > 105 C°
1) Call for authorsed servce
E 14 Exhaust ( FLUE )
temperature probe fault
Boler does not work, E14 error
code flashng on the screen
> Central heatng FLUE
temperature
sensor faulty
1) Reset & Restart boler
2) Call for authorsed servce
E 15 Fan falure (feedback/supply) Boler does not work, E15 error
code flashng on the screen
> Fan harness 1) Reset & Restart boler
2) Call for authorsed servce
E 16 Central heatng temperature
RETURN sensor faulty
Boler does not work, E16 error
code flashng on the screen
> Central heatng RETURN
temperature sensor faulty
1) Reset & Restart boler
2) Call for authorsed servce
E 17 Temperature derence
between FLOW and LIMIT NTC
(Double Heatng Probe) faulty
FLOW and LIMIT sensor
(DOUBLE NTC) malfuncton
> FLOW and LIMIT Sensor (
double NTC ) faulty
1) Reset & Restart boler
2) Call for authorsed servce
E 19 Water flow meter nput
readng
Lack of domestc heatng
water on request
Wrong parameters settled on
TsP menu
1) Call for authorsed servce at frst
2) Only authorsed servce must adjust TsP Parameter P01=0 wth
defalut value
E 20 CH vertemperature,
Temperature Central Heatng >
TSP 81 value °C
Boler does not work, E81 error
code flashng on the screen
> Lack of water on the system
> Pump blockage
> Pump falure
> Pump harness
> Installaton blockage
1) RESET boler at frst check f problem s resolved.
2) Check boler central heatng valves are open f they are closed
open all
3) Check all radator valves are open f they are closed. Mnmum
3 meters of radator must be open
4) RESET boler and check f problem s resolve
5) Call for authorsed servce