
Designation model alfea extensa duo + 5 6 8 10
Nominal heating performances (outdoor temperature/ initial temperature)
Heat output
+7 °C / +35 °C - Floor heating system kW 4,50 6,00 7,50 10,00
-7 °C / +35 °C - Floor heating system kW 4,10 4,60 5,70 7,40
+7 °C / +45 °C - Low temperature radiator kW 4,50 5,10 6,20 8,27
-7 °C / +45 °C - Low temperature radiator kW 4,10 4,45 5,05 7,40
+7 °C / +55 °C - Radiator kW 4,50 4,50 5,0 7,00
-7 °C / +55 °C - Radiator kW 3,70 3,85 5,20 7,00
Power absorbed
+7 °C / +35 °C - Floor heating system kW 1,00 1,41 1,84 2,49
-7 °C / +35 °C - Floor heating system kW 1,47 1,74 2,23 2,97
+7 °C / +45 °C - Low temperature radiator kW 1,31 1,50 1,87 2,53
-7 °C / +45 °C - Low temperature radiator kW 1,86 2,04 2,47 3,70
+7 °C / +55 °C - Radiator kW 1,79 1,79 1,94 2,86
-7 °C / +55 °C - Radiator kW 2,20 2,33 3,34 4,15
Coefcient of performance (COP) (+7 °C / + 35 °C) 4,52 4,26 4,08 4,02
Electrical characteristics
Supply voltage (50 HZ) V 230
Maximum current for appliance A11 12,5 17,5 18,5
Nominal current A4,5 6,3 8,1 10,9
Maximum current of the Heating electrical back-ups A13,05 / 26,1
Power of the Heating electrical back-ups (option) kW ajustable 3 or 6 kW
Real power absorbed by the fan W 49 49 49 100
Real power absorbed by the circulation pump W 24
Maximum power absorption by the outdoor unit W 2530 2875 4025 4255
Electrical back-up power DHW W 1500
Hydraulic circuit
Maximum operating pressure Heating bar 3
Maximum operating pressure Domestic hot water tank bar 10
Hydraulic system ow rate 4°C<Δt<8°C (nominal conditions) l/h 490 / 980 650 / 1300 810 / 1620 1080 / 2160
Various
Weight of outdoor unit kg 41 41 42 60
Weight of hydraulic unit (empty / full of water) kg 152 / 366
Water capacity of the hydraulic unit / of the domestic tank l 24 / 190
Noise level at 1 m 1 (hydraulic unit) dB 39
Sound power level according to EN 12102 2 (hydraulic unit) dB 46
Noise level at 1 m 1 (outdoor unit) dB 38 38 41 42
Sound power level according to EN 12102 2 (outdoor unit) dB 63 63 69 69
Heating system operating limits
Outdoor temperature mini / maxi °C -20 / +35
Initial max. heating water temperature Floor heating system °C 45
Initial max. heating water temperature Low temperature radiator °C 52
Refrigeration circuit
Diameter of "Gas" pipes inches 1/2 1/2 5/8 5/8
Diameter of "Liquid" pipes inches 1/4 1/4 1/4 3/8
Factory charge of refrigerant R410A 3g 1100 1100 1400 1800
Maximum operating pressure bar 41,5
Minimum / Maximum length of pipes 4m 5 / see "Additional charge", page 22
Maximum length of pipes 5 / Maximum level difference m 20 / 15
1.3 Specications
1 Sound pressure level in (x)m of the device, 1,5m of the ground,
the open eld.
2 The sound power level is a laboratory measure of the emitted
sound power but contrary to the noise level, it doesn't correspond to
the measure of the felt.
3 Refrigerant R410A (as per the standard EN 378.1).
4 Factory charge of refrigerant R410A.
5 Taking into account the possible additional load of refrigeration uid
R410A (see "Additional charge", page 22).
Installation and operating manual "1585 - EN" - 5 -
Air to Water Heat Pump (Split integrated DHW type)
Designation model Waterstage Comfort 5 6 8 10