1.3 6SHFL¿FDWLRQV
16RXQGSUHVVXUHOHYHOLQ[PRIWKHGHYLFHPRIWKHJURXQGWKHRSHQ¿HOG
2The sound power level is a laboratory measure of the emitted sound power but
FRQWUDU\WRWKHQRLVHOHYHOLWGRHVQWFRUUHVSRQGWRWKHPHDVXUHRIWKHIHOW
35HIULJHUDQW5$DVSHUWKHVWDQGDUG(1
4)DFWRU\FKDUJHRIUHIULJHUDQW5$
5Taking into account thepossible additionalload of refrigerantR410A(see page 21)
,QVWDOODWLRQDQGRSHUDWLQJPDQXDO(1
$LUWR:DWHU+HDW3XPS6SOLWLQWHJUDWHG'+:W\SH
'HVLJQDWLRQPRGHO:DWHUVWDJH+LJK3RZHU 11 Single phase 14 Single phase 11 3-phase 14 3-phase 16 3-phase
Nominal heating performances RXWGRRUWHPSHUDWXUHLQLWLDOWHPSHUDWXUH
Heat output
+7 °C / +35 °C - Floor heating system kW 10,80 13,50 10,80 13,50 15,17
-7 °C / +35 °C - Floor heating system kW 10,80 12,00 10,80 13,00 13,50
+7 °C / +45 °C - Low temperature radiator kW 9,23 11,54 10,10 12,60 13,00
-7 °C / +45 °C - Low temperature radiator kW 9,16 11,45 10,02 12,50 13,00
+7 °C / +55 °C - Radiator kW 7,74 9,67 9,48 11,80 12,96
-7 °C / +55 °C - Radiator kW 7,51 9,25 9,20 10,60 11,90
3RZHUDEVRUEHG
&&)ORRUKHDWLQJV\VWHP N: 2,54 3,23 2,51 3,20 3,70
&&)ORRUKHDWLQJV\VWHP N: 4,32 5,08 4,28 5,18 5,40
&&/RZWHPSHUDWXUHUDGLDWRU N: 2,84 3,72 3,01 3,81 4,00
&&/RZWHPSHUDWXUHUDGLDWRU N: 4,58 5,92 4,63 6,00 6,37
&&5DGLDWRU N: 3,13 4,03 3,60 4,61 5,14
&&5DGLDWRU N: 4,56 5,65 5,08 6,04 6,88
&RHI¿FLHQWRISHUIRUPDQFH&23&& 4,25 4,18 4,30 4,22 4,10
Electrical characteristics
Supply voltage (50 HZ) V 230 400
Maximum current for appliance A 22 25 8,5 9,5 10,5
Nominal current A 11,4 14,2 3,7 4,8 5,5
Maximum current of the electrical back-ups (heating) A 13,05/26,1 13
Power of the electrical back-ups (heating) kW ajustable3 or6kW(Singlephase) 9 kW (3-phase)
Real power absorbed by the fan W 2x100 2x104
Real power absorbed by the circulation pump W 70
Maximum power absorption by the outdoor unit W 5060 5750 5865 6555 7245
Electrical back-up power DHW W 1500
Hydraulic circuit
Maximum operating pressure Heating bar 3
Maximum operating pressure Domestic hot water tank bar 10
+\GUDXOLFV\VWHPÀRZUDWH&ǻW&QRPLQDOFRQGLWLRQVPLQPD[ l/h 1170 / 2340 1460 / 2920 1170 / 2340 1460 / 2920 1650 / 3290
Various
Weight of outdoor unit kg 92 99
Weight of hydraulic unit (empty / full of water) kg 152/ 366
Water capacity of the hydraulic unit/ the domestic tank l 24 / 190
Noise level at 1 m 1(hydraulic unit) dB 39
Sound power level according to EN 12102 2(hydraulic unit) dB 46
Noise level at 5 m 1(outdoor unit) dB 42 43 39 41 42
Sound power level according to EN 12102 2(outdoor unit) dB 69 70 66 68 69
Heating system operating limits
Outdoor temperature mini/maxi °C -25 / +35
,QLWLDOPD[KHDWLQJZDWHUWHPSHUDWXUH)ORRUKHDWLQJV\VWHP °C 45
,QLWLDOPD[KHDWLQJZDWHUWHPSHUDWXUH/RZWHPSHUDWXUHUDGLDWRU °C 60
Refrigeration circuit
Diameter of gas pipes inches 5/8
Diameter of liquid pipes inches 3/8
Factory charge of refrigerant R410A3g 2500
Maximum operating pressure bar 41,5
Minimum length of pipes m 5
Maximum length of pipes 4m15
Maximum length of pipes 5/ Maximum level difference 5m 20 / 15