manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wayne
  6. •
  7. Water Pump
  8. •
  9. Wayne 390601-001 User manual

Wayne 390601-001 User manual

Limited Warranty
For one year from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for
the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination
by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see
your dealer. Be prepared to provide the model number when exercising this warranty. All transportation charges
on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse,
neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written
instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF
PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSE-
QUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or
limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited
warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall
Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not
limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated
equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or
claims of buyer’s customers for such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim,
you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne
(800-237-0987) for return authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________
INSTALLATION DATE_____________
ATTACH YOUR RECEIPT HERE
Operating Instructions
4
www.waynepumps.com
Electronic Sump
Pump Control and
Alarm
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
© 2007 Wayne Water Systems
Description
The FloodAlert control uses patented
electronic surface transfer (EST) to
detect the presence of water. Sensing
is not affected by oil, soaps, turbulence
or the waters resistance and is
intrinsically safe.
When water touches the tip of
FloodAlert’s sensing wire, a relay closes
turning on your pump. Patent pending
Zcross technology closes the relay
contact at zero volts and opens it at
zero current. This stops relay arcing,
extending relay life, stopping power-
line flicker, and making pump startups
smoother.
A settable “Run Timer” allows you to
change the pumping depth without
opening the sump pump pit. This
timer allows any quantity of water to
be pumped out of the sump and can
even pump it completely dry without
running the pump too long.
If the water level does not fall below
the tip of the wire while the pump is
running an alarm sounds indicating
high water pump failure or a clogged
discharge line. Two lights alternately
flash, warning you of a problem before
your basement floods. A standard 9-
volt battery operates the alarm during
a loss of power at the wall outlet.
The battery maintains the sensor and
alarm for two days without power.
Circuitry maintains the battery voltage
extending its shelf life to 7-years.
Use FloodAlert to convert your manual
pump to automatic or to replace a
defective float switch. FloodAlert
requires a grounded pump plug
or, alternatively, a grounded
connection to the sump. It will not
apply 120-volts to the pump motor
without proper grounding.
Operating Instructions AU5ES
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe
the following symbols.
Warning
indicates
a potentially hazardous situation
which, if not avoided, COULD result in
death or serious injury.
Caution
indicates
a potentially minor or moderate injury.
390601-001 6/07
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make
sure to tighten fittings, bolts, etc.,
before putting unit into service.
Do
not
operate unit if damaged during
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
Figure 1
For parts, product & service information
visit www.waynepumps.com
Operation
Before performing any wiring to sump
pump disconnect power to pump.
1) Plug FloodAlert into a 120-volt
grounded wall outlet.
2) Insert the battery jumper (See
Figure 2).
3) Plug grounded pump into Flood-
Alert outlet.
4) Run the sensor wire to the sump
and fasten using wire ties. Its
tip should be at the level where
you want the pump to begin
operating.
SETTING THE RUN TIMER
The run timer sets the pumping depth
and how much water you prefer to
pump out of the pit. It does not start
timing until the water level drops
below the sensor wire. The moment
the water drops below the sensing
wire the run timer starts limiting
the pumps run time. Initially set the
time to 5-seconds. Test the operation
by filling the sump pit with water
until the sensor wire is below water.
The timer should be set so that the
pump turns off before the water level
reaches the pump’s inlet. If the water
level reaches the pump’s inlet, it will no
longer pump water. If a pump has an
inlet on the bottom side of the pump
and the water level is low enough to
allow air into the pump, an air-lock
condition may occur. Air-lock happens
when air is trapped in the pump and
can not escape. Air-lock condition can
be avoided if the water level stays
above the pump’s inlet. Adjust set-time
to remove desired amount of water
and to avoid an air-lock condition.
BATTERY
The jumper on the cover connects the
battery to the circuitry. If the unit loses
power the battery runs the alarm and
sensor. It should be replaced every year
or when a power loss occurs for over
two days.
To replace battery:
Purchase a 9-volt alkaline battery.
Unplug the pump from the unit and
unplug the unit from the wall outlet.
Remove the battery jumper. Remove
the 4-screws holding the cover. Remove
the cover from the base by using a
rocking motion to free the receptacle
from its slide on tabs. Unsnap the
old battery and snap in the new one.
Replace the cover making sure to press
hard on the receptacle to slide it fully
onto its 3-tabs. Replace the 4-screws
holding the cover. Plug the unit into
the wall outlet and the pump into the
unit. Replace the battery jumper.
Do not
plug
unit in with the cover removed. High
voltages are present.
WATER SENSING
EST measures the surface area of
liquid contacting two metals. Since the
sump is grounded for safety reasons,
something metal in the sump must be
grounded. This might be the pump
case, the sump itself, or on a plastic
pump, it’s motor shaft. The sensing
wire is the other metal. EST senses the
square inches of contact between the
two metals and their distance. The
purpose is to ignore thin water films
that might coat the surface of a wire
or pipe and only detect the main body
of water. It does not detect resistance
and touching the sensing wire to
ground does not activate it.
OIL FILMS
EST is able to break apart oil films that
might coat its sensing probe. Oil films
float on the surface of water adhering
to the surface of metals preventing
them from making electrical contact
with the water. EST’s tiny fast moving
electronic pulses move non-conductive
liquids away from the probe, busting
them apart if they manage to coat it.
Operating Instructions
Figure 2
2
www.waynepumps.com
Dial sets the amount of
time the pump needs to
drain water from sump
Battery
Jumper
Plug sump pump
into outlet
Power Indicator
Light
Gives indication
that water is in
contact with sensor
Indicates pump
is running
When water is in contact
with sensor for 15 seconds
the alarm will sound and
the “Water Detected” and
“Pump Relay On” LEDs will
flash alternately
Model AU5ES
WATER LEVEL
Water seeks its own level but
compacted soil causes it to deviate to
the path of least resistance. As a result
ground water will not rise at a uniform
level across your entire basement.
A sump pump pit must not only be
deep enough, but more importantly
maintain a low enough water level to
insure that the path of least resistance
remains underground and not across
the top of your basement floor. An
empty sump draws more groundwater
from surrounding areas than a full one.
Experience shows this to be roughly a
4:1 ratio; a 1-foot below grade peak
water level draws from only a 4-foot
radius while a 3-foot below grade peak
water level extends this out to 12-feet.
A common error is setting the water
level as high as possible to minimize
pump cycling and later noticing that
water surfaces some distance away.
Zcross technology in FloodAlert allows
you to set the water level as low as
practical without worrying about high
cycle operation.
RATINGS
Voltage . . . . . . . . . . . . . . . . . . 100-130 VAC
Max. Current . . . . . . . . . . . . . 15-Amps Peak Run Current
Locked Rotor . . . . . . . . . . . . . 40-Amps
Starting Current . . . . . . . . . . . 40-Amps
Battery . . . . . . . . . . . . . . . . . . 9-Volt Alkaline
Alarm . . . . . . . . . . . . . . . . . . . 80db @ 1m Alternating
Run Timer . . . . . . . . . . . . . . . . 2-60 Seconds
Patent . . . . . . . . . . . . . . . . . . . 6,820,483 others pending
Notes
Figure 3
3
www.waynepumps.com

This manual suits for next models

1

Other Wayne Water Pump manuals

Wayne WTX50 Guide

Wayne

Wayne WTX50 Guide

Wayne RUP160 Service manual

Wayne

Wayne RUP160 Service manual

Wayne PC4 User manual

Wayne

Wayne PC4 User manual

Wayne 351301-001 Service manual

Wayne

Wayne 351301-001 Service manual

Wayne JSU50 User manual

Wayne

Wayne JSU50 User manual

Wayne WLS Series Instructions for use

Wayne

Wayne WLS Series Instructions for use

Wayne 320802-001 Manual

Wayne

Wayne 320802-001 Manual

Wayne RUP160 Service manual

Wayne

Wayne RUP160 Service manual

Wayne 331400-001 User manual

Wayne

Wayne 331400-001 User manual

Wayne CDU980E User manual

Wayne

Wayne CDU980E User manual

Wayne 330102-001 Service manual

Wayne

Wayne 330102-001 Service manual

Wayne PC1 Series Instructions for use

Wayne

Wayne PC1 Series Instructions for use

Wayne T50S10-2 Service manual

Wayne

Wayne T50S10-2 Service manual

Wayne EEAUP250 Service manual

Wayne

Wayne EEAUP250 Service manual

Wayne GPH400 Manual

Wayne

Wayne GPH400 Manual

Wayne CDU800SS User manual

Wayne

Wayne CDU800SS User manual

Wayne 330002-001 Service manual

Wayne

Wayne 330002-001 Service manual

Wayne PC1 Series Service manual

Wayne

Wayne PC1 Series Service manual

Wayne 330600-001 Service manual

Wayne

Wayne 330600-001 Service manual

Wayne 360516-001 Service manual

Wayne

Wayne 360516-001 Service manual

Wayne CDUCAP995 Guide

Wayne

Wayne CDUCAP995 Guide

Wayne WPCP250 Service manual

Wayne

Wayne WPCP250 Service manual

Wayne WLS75 Service manual

Wayne

Wayne WLS75 Service manual

Wayne WaterBug WWB Programming manual

Wayne

Wayne WaterBug WWB Programming manual

Popular Water Pump manuals by other brands

SKF H Series User and maintenance instructions

SKF

SKF H Series User and maintenance instructions

Larzep HEP0180 INSTRUCTIONS & MAINTENANCE SHEET

Larzep

Larzep HEP0180 INSTRUCTIONS & MAINTENANCE SHEET

ITT Goulds Pumps XHD Installation, operation and maintenance manual

ITT

ITT Goulds Pumps XHD Installation, operation and maintenance manual

Graco PRESIDENT 965-124 Instructions-parts list

Graco

Graco PRESIDENT 965-124 Instructions-parts list

Graco HYDRA-SPRAY President A Series Instructions-parts list

Graco

Graco HYDRA-SPRAY President A Series Instructions-parts list

HIDROBEX XKS250P User and maintenance manual

HIDROBEX

HIDROBEX XKS250P User and maintenance manual

STA-RITE 400S Series owner's manual

STA-RITE

STA-RITE 400S Series owner's manual

Liberty Pumps XLGV02 Series installation manual

Liberty Pumps

Liberty Pumps XLGV02 Series installation manual

SKF LAGG 18M Instructions for use

SKF

SKF LAGG 18M Instructions for use

Ingersoll-Rand 1" DIAPHRAGM PUMP PW10A-X-X Operator's manual

Ingersoll-Rand

Ingersoll-Rand 1" DIAPHRAGM PUMP PW10A-X-X Operator's manual

IWAKI APN-05-W instruction manual

IWAKI

IWAKI APN-05-W instruction manual

Graco Series B Instructions-parts list

Graco

Graco Series B Instructions-parts list

Etatron BH3-V Operating	instructions and maintenance

Etatron

Etatron BH3-V Operating instructions and maintenance

Witt hrp 5040 Installation and operating instructions

Witt

Witt hrp 5040 Installation and operating instructions

Eckerle EE 1650 installation instructions

Eckerle

Eckerle EE 1650 installation instructions

Edwards EXT70 Series instruction manual

Edwards

Edwards EXT70 Series instruction manual

Oase AquaMax Eco Premium 4000 Operating	 instruction

Oase

Oase AquaMax Eco Premium 4000 Operating instruction

Pentair AERMOTOR SPCM Series Installation and operation

Pentair

Pentair AERMOTOR SPCM Series Installation and operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.