Section 28M-K2Q-BK0-20C
030-101562 Rev. B
R
0505ICRB 3
2.4 Making Ground and Power Connections
2.4.1 Ground. Ground connections are made to the ground lug
located in the top right-hand corner of the kit plate. This will provide
a common ground for the mounting. All grounding practices apply
that would apply for mounting a single 28MA204AK assembly. For
applications requiring chassis ground to be connected to circuit
ground, an optional green wire strap is provided for installation be-
tween the GND lug and the GND position of the 28MA204AK TB1
power terminal block.
- CAUTION -
Never apply power until all installer connections are made.
2.4.2 Power. Power connections, if required, are made to the top
of the 28MA204AK mounting. Refer to the enclosed 28MA204AK
mounting practice for appropriate power connections to the mount-
ing.
2.5 Making Facility-Side Wiring Connections
Facility-side wiring connections are made to the top half of the 66-
type terminal block. Refer to Figure 3 and Table 1.
2.6 Making Customer-Side Wiring Connections
Customer connections are typically made to the 66-type block, but
also can be made to the 8-pin RJ48 jacks on the mounting.
S66-Block. If extending the RJ48 jack beyond the mounting, use
the bottom half of the 66-block, as shown in Figure 3, and refer
to Table 2 for correct circuit, wire, and terminal designations.
The block is factory pre-wired to four RJ48 pigtails, which are
provided and shipped factory-inserted into the four RJ48 jacks
at the bottom of the mounting. The 66 block provides both
RJ48C (for HDSL/NIU applications) and RJ48S (for DDS/
DST) connections. Always insure the jack switches at the
bottom of the mounting are set to the correct position per the
connections to the 66 block for RJ48C or RJ48S applications.
SRJ48 Jacks. Customer connections also can be made to the
RJ48 jacks located at the bottom of the mounting, as shown in
Figure 3. This is done by removing the RJ48 pigtails (provided
with the kit and pre-wired to the 66-block) and inserting custom-
er-supplied, separate, RJ48 cable plugs into the jacks. The
mounting also contains a jack switch for each jack, to set the jack
type to either RJ48C (for HDSL/NIU applications) or RJ48S
(for DDS/DST applications). The switches are factory preset to
the C" position. Insure the jack switches (at the bottom of the
mounting) are set to the proper position for the application. See
the mounting practice for details.
2.7 Installing the Plug-in Modules
Consult the module practice when installing modules. Before instal-
ling any module, set any option switches to the desired positions.
Align the module with the mounting card guides above and below
the unit and fully-insert into the slot connector.
CAUTION - STATIC-SENSITIVE
This product and the plug-in product installed inside the assembly
may contain static-sensitive components! Follow proper electrostatic
discharge procedures to maintain personal and equipment safety.
3. TESTING & TROUBLESHOOTING
The equipment should not be field repaired. If trouble occurs, check
that the CO power fuse is not blown and verify all installer connec-
tions, module connections, option switch settings, and that modules
have a positive connection with the shelf connectors. If trouble per-
sists, replace the suspect unit with another, optioned identically, and
retest. If the replacement operates correctly, the original may be
faulty and can be returned to Westell for repair or replacement
(Paragraph 5.2). These procedures are not designed to effect repairs
or modifications. Tests/repairs beyond those outlined herein or re-
placing a faulty unit are not recommended and may void a warranty.
CIRCUIT COLOR 4 SLOT MOUNTING 66 BLOCK
white/blue T 3
1blue R 4
white/orange T1 5
orange R1 6
white/green T 9
2green R10
white/brown T1 11
brown R1 12
white/blue T15
3blue R16
white/orange T1 17
orange R1 18
white/green T21
4green R22
white/brown T1 23
brown R1 24
Table 1. Network-Side Wiring Chart
4 SLOT MOUNTING
CIRCUIT COLOR RJ48
PINOUT RJ48C
HDSL/NIU
RJ48S
DDS/DST
66
BLOCK
white/blue 5CT unused 27
blue 4CR unused 28
1white/orange 2CT1 DTT 29
orange 1CR1 DTR 30
white/green 8unused DRT 31
green 7unused DRR 32
white/blue 5CT unused 33
blue 4CR unused 34
2white/orange 2CT1 DTT 35
orange 1CR1 DTR 36
white/green 8unused DRT 37
green 7unused DRR 38
white/blue 5CT unused 39
blue 4CR unused 40
3white/orange 2CT1 DTT 41
orange 1CR1 DTR 42
white/green 8unused DRT 43
green 7unused DRR 44
white/blue 5CT unused 45
blue 4CR unused 46
4white/orange 2CT1 DTT 47
orange 1CR1 DTR 48
white/green 8unused DRT 49
green 7unused DRR 50
Table 2. Customer-Side Wiring Chart
4. CUSTOMER & TECHNICAL SERVICES
If technical or customer assistance is required, contact Westell via
one of the following options:
Voice: (630) 898-2500
Voice: (800) 323-6883
Visit the Westell internet site at http://www.Westell.com.
5. WARRANTY & REPAIRS
5.1 Warranty. Westell warrants this product to be defect-free
at shipment time and to be fully functional for the time period speci-