WESTERSTRAND QWTIME III WDP-AMP User manual

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
1 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
User Manual
Impulse Amplifier WDP-AMP

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
2 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
List of contents
TECHNICAL SPECIFICATIONS...............................................................................................................................3
GENERAL DESCRIPTION........................................................................................................................................4
INSTALLATION ........................................................................................................................................................5
C
ALCULATION OF CABLE AREA IN TIME SYSTEMS
.................................................................................................................6
S
YNCHRONISATION INPUT
.....................................................................................................................................................7
General ............................................................................................................................................................................7
Remark .............................................................................................................................................................................7
1. PROGRAMMING................................................................................................................................................... 8
G
ENERAL
..............................................................................................................................................................................8
R
UNNING MODE
....................................................................................................................................................................8
S
TART UP
..............................................................................................................................................................................9
S
ET TIME WHEN IN OPERATION
............................................................................................................................................10
Summer to winter ( Day light saving ) ...........................................................................................................................10
S
LAVE
C
LOCK
.....................................................................................................................................................................11
A
LARMS
..............................................................................................................................................................................12
Example 1, display alarms .............................................................................................................................................13
Example 2, erase (clear) alarms ....................................................................................................................................14
S
PEC
.-F
UNCTIONS
...............................................................................................................................................................15
Status..............................................................................................................................................................................16
Keylock...........................................................................................................................................................................18
Language .......................................................................................................................................................................20
Country ..........................................................................................................................................................................21
Setup...............................................................................................................................................................................22
FAULT TRACING....................................................................................................................................................28

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
3 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Technical specifications
Crystal Frequency: 4,915200 MHz.
Accuracy: 0,1 sec./24 hours (at +20°C).
Microprocessor: HD6412394.
Max. load impulse output: Minute 1A, second 0,5A. (The output is equipped with short circuit protection
which resets automatically.)
Impulse duration: Minute 2 sec. selectable 0.1-9.9 sec.
Seconds 0.5 sec. selectable 0.1-1 sec.
Impulse memory: 72 hours (impulse memory with rapid impulsing after power failure).
(in sync. mode)
Connection voltage: 230 V 50 Hz -5% +10%
Power consumption: 30 VA.
Ambient temperature: Between 0°C and +40°C.
Relative humidity: Max. 85% non-condensing.
Case: IP 65, light grey plastic (Polystyrol) with transparent protection cover.
CE-Approval, EMC Emission acc. to EN61000-6-3, Immunity acc. to. EN61000-6-2.
Art. numbers: 123314-00 (230V AC)

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
4 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
General description
The WDP-AMP is an electronic quartz Impulse Amplifier for operating and control of analogue and digital
Slave Clocks. The impulse amplifier is intended for amplification of polar reversing impulses or hard wired
DCF Time Code, TC. and it can work in sync. or slave mode.
The unit is equipped with electronic fuse and transient protection. The electronic fuse is tripped in case of
overload on the impulse output. After resetting the alarm, the connected clocks are set to the correct time by
rapid impulses.
In case of power failure the built in Real Time Clock keeps the internal time updated.
Connected Slave Clocks are automatically corrected by rapid impulsing when power returns.
Summer/winter time correction (daylight saving) is pre-programmed and, if the amplifier is used in sync. mode,
the correction is done fully automatic.
Indication for alarm
Indication for mains voltage
Indication for synchronisation
Indication for outgoing minute impulse
Connection space

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
5 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Installation
The Impulse Amplifier is intended for wall mounting.
1. Screw in the upper fixing screw halfway and hang up the unit.
2. Screw in the two lower screws, accessible under the connection space cover.
3. Connect the slave clock lines.
4. Connect the supply voltage.
123314-00

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
6 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Calculation of cable area in time systems
General
To make a time system with impulse operated analogue and digital slave clocks perform satisfactory, the cable
from the Impulse Amplifier to the Slave Clocks need to be dimensioned correctly.
A 10% voltage drop is allowed in the cable.
The length and area of the cable and also the current (load) on the cable affect the voltage drop.
Formula
A = l x I x k
A = Area [mm
2
]
l = cable length [m]
I = current [A]
k = 0,015 [constant]
Power consumption
Impulse Slave Clocks
Analogue clocks minute ≤400 mm: 7,5 mA
Analogue clocks minute ≤900 mm: 15 mA
Analogue clocks minute + sweep seconds hand ≤400 mm: 25 mA
Digital Clocks: 4 mA
Time-Code (TC) Slave Clocks
Analogue clocks minute ≤400 mm: 14 mA
Analogue clocks minute ≤900 mm: 20 mA
Analogue clocks minute + sweep seconds hand ≤400 mm, indoor: 12 mA
Analogue clocks minute + sweep seconds hand ≤400 mm, outdoor: 20 mA
Analogue clocks minute + sweep seconds hand ≤900 mm: 27 mA
Example
A time system consists of 40 pcs. analogue clocks with diameter 300 mm.
The power consumption will then be 40 x 7,5 = 300 mA = 0,3A.
Cable length is 100 metres.
A = 100 x 0,3 x 0,015 = 0,45 mm
2
Choose a cable with an area of at least 0,45 mm
2
.

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
7 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Synchronisation input
General
The Impulse Amplifier is equipped with a synchronisation input intended for connection to an external
synchronisation source. The synchronisation source can be a Master Clock transmitting polar reversing impulses
or hard wired DCF Time Code, TC.
The amplifier can work in either synchronisation (sync) or slave mode.
Glossary
Sync. mode: The Amplifier will continue to send out pulses even if the synchronisation source is defect.
Slave mode: The Amplifier will stop sending out pulses if the synchronisation source is defect.
The Impulse Amplifier is factory prepared for sync. mode.
Remark
When using sync. mode it is essential that the time and date is correctly entered when the Impulse Amplifier is
started for the first time.
Entered time must not differ more than +/- 30 seconds compared to the time of the Master Clock.
The date information is used by the amplifier to do the summer/winter change.

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
8 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
MON 14 MAR 2011
10:11:00 LTw
1. Programming
General
Using 6 buttons and a 2-row 16-character display carries out all programming.
Programming is self-instructive and to simplify the dialogue Yes/No questions are used.
Running mode
When the Impulse Amplifier is in operation it shows date
and time in the display.
This is called running mode in this documentation.
LTs = Local Time summer.
LTw = Local Time winter.
1- Select function ↑
↑↑
↑↓
↓↓
↓
2- Enter programming mode YES
3- Move sideways ←
←←
←→
→→
→
4- Change/scroll ↑
↑↑
↑↓
↓↓
↓
5- Accept YES
6- Cancel / Leave prog. mode ←
←←
←
SET TIME
MON 14 MAR 2011
10:11:00 LTw
ALARMS
SPEC.-FUNCTIONS
SLAVE CLOCK

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
9 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Start up
When the Impulse Amplifier is connected for the first time correct/requested
language has to be entered. Press NO until requested
language occurs in the display e.g. English. Accept with YES.
Press NO until correct country code occurs.
For Finland, select FIN. Accept with YES.
Set, by using the arrows, the right time format i.e. year, month, day and hour
but a few minutes in advance.
Wait for the right time and synchronise using YES.
Now the question: SLAVE CLOCK 12.00?
If the Slave Clocks show 12.00, answer YES, if not set the time shown by
the slave clocks. Accept using YES.
Accept using YES.
The Impulse Amplifier is now in running mode.
NOTE! If a slave clock runs out by a minute, its cabling must be pole changed and
the slave clock to be corrected manually.
NOTE! If the time of the slave clocks is ahead of correct/present time the Impulse Amplifier
Programmer will wait until correct time corresponds with the slave clocks.
STARTING
SET TIME
110314 09:07
MON 14 MAR 2011
09:07:00 LTw
LANGUAGE
ENGLISH?
COUNTRY
FIN ?
SLAVE CLOCK
= 12:00 OFF
SLAVE CLOCK
= 12:00 ON?

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
10 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Set time when in operation
Select function using ↓.
Enter the programming mode with YES.
Set, by using the arrows, the right time.
Format; year, month, day and hour but a few minutes in advance.
Wait for the right time and synchronise using YES.
Leave programming mode by pressing ←several times.
The Impulse Amplifier is now back in running mode.
Summer to winter ( Day light saving )
Resetting between summer and wintertime is fully automatic and does not need programming.
MON 14 MAR 2011
09:07:00 LTw
SET TIME
110314 10:13
SET TIME
SET TIME
MON 14 MAR 2011
10:13:00 LTw

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
11 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Slave Clock
This function is used to enter the time that the slave clocks are showing.
This is useful if, by some reason, the Impulse Amplifier and the slave clocks should show different times.
When the slave clock time has been entered, the Impulse Amplifier will automatically adjust the slave clocks to
correct time.
Please note that before using this function make sure that all connected slave clocks are showing the same time.
If any of the slave clocks are showing a divergent time this clock must be manually adjusted to the same time as
the other clocks.
The impulses to the slave clocks are temporarily stopped when entering this function.
Select function using ↓.
Enter the programming mode with YES.
SLAVE CLOCK = 09.07? (Example)
If the slave clocks shows 09.07 answer YES,
if not, set the time shown by the slave clocks.
YES.
YES.
Leave programming mode by pressing ←several times.
The Impulse Amplifier is now back in running mode.
MON 14 MAR 2011
09:07:00 LTw
SLAVE CLOCK
= 09:07 OFF
SLAVE CLOCK
SLAVE CLOCK
MON 14 MAR 2011
09:07:00 LTw
SLAVE CLOCK
= 09:07 OFF
SLAVE CLOCK
= 09:07 ON?

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
12 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Alarms
The Impulse Amplifier is equipped with several supervision facilities to detect functional disturbances.
When a functional disturbance is detected the following will happen:
•Red alarm LED is lit.
•Alarm relay* is activated.
•An alarm message is displayed in function ALARM.
The function ALARM is used to display and erase (clear) alarm messages.
Type of alarm Indication Reason for alarm
Action
NO RADIO Red alarm LED lit. The synchronisation
signal is lost.
Check the incoming
synchronisation signal.
If OK, clear the alarm.
UF LOW Red alarm LED lit. Impulse voltage below
alarm limit.
Check the load on the impulse
output. If OK, clear the alarm.
SHORT CIRCUIT Red alarm LED lit. Short circuit on
impulse output
Remove the short circuit.
If OK, clear the alarm.
CURRENT LOW Red alarm LED lit. Impulse current below
alarm limit.
Check the load on the impulse
output. If OK, check that the alarm
limit is correctly configured.
If OK, clear the alarm.
CURRENT HIGH Red alarm LED lit. Impulse current above
alarm limit.
Check the load on the impulse
output. If OK, check that the alarm
limit is correctly configured.
If OK, clear the alarm.
POWER DOWN Red alarm LED lit.
Works only if the Impulse
Amplifier is equipped
with batteries for running
reserve.
By some reason the
power to the Impulse
Amplifier has been
switched off.
Check the mains.
If OK, clear the alarm.

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
13 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
To show the alarms
To erase the alarms
Example 1, display alarms
Select function using ↑↓ .
Accept with YES.
Press NO until the wished function is shown.
Accept with YES.
The alarm is displayed.
Press ↑↓ to see next alarm.
Return to running mode press ←.
←.
←.
MON 14 MAR 2011
09:07:00 LTw
ALARMS
09MAR 15:52
SHORT CIRCUIT
MON 14 MAR 2011
09:07:00 LTw
ALARMS- DISPLAY
ALARMS- DISPLAY
ALARMS- ERASE
ALARMS- DISPLAY
ALARMS

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
14 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Example 2, erase (clear) alarms
Select function using ↑↓ .
Accept with YES.
Press NO until the wished function is shown.
Accept with YES.
The alarm is displayed.
Press YES to erase the alarm.
Accept with YES.
Return to running mode press ←.
←.
MON 14 MAR 2011
09:07:00 LTw
ALARMS
09MAR 15:52
SHORT CIRCUIT
MON 14 MAR 2011
09:07:00 LTw
ALARMS- ERASE
ALARMS- ERASE
ALARMS
ERASE?

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
15 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Spec.-Functions
The special functions contain functions used during setup and configuration of the Impulse Amplifier.
If the default settings are used no configuration is needed.
Select function using ↓.
Accept with YES.
Press NO until wished function is shown.
Accept with YES.
Show status information of the different output/ input in
the Impulse Amplifier.
Keylock and password function.
Language selection.
Country selection.
Selection of position for astronomical function.
Setup / configuration of the different impulse system, type of
synchronisation etc.
Display format in running mode.
Present software version.
Return to running mode press ←.
MON 14 MAR 2011
09:07:00 LTw
SPEC.-FUNCTIONS
STATUS
MON 14 MAR 2011
09:07:00 LTw
SPEC.-FUNCTIONS
SOFTWARE VERSION
DISPLAY FORMAT
SPEC.-FUNCTIONS
STATUS
KEYLOCK
LANGUAGE
COUNTRY
POSITION
SETUP
STATUS

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
16 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Status
With this function each input/output status can be checked.
Example:
Check the status of the synchronisation input.
Select function using ↓.
Accept with YES.
Press NO until wished function is shown.
Accept with YES.
Press NO until wished input/output is shown.
Accept with YES.
The Impulse Amplifier has accepted 60% of the synchronisation pulses.
Last synchronisation was 13/3 19:59.
Return to running mode press ←.
←
←
MON 14 MAR 2011
09:07:00 LTw
SPEC.-FUNCTIONS
SPEC.-FUNCTIONS
STATUS
STATUS
SYNC.SOURCE
MON 14 MAR 2011
09:07:00 LTw
1/1 MIN SYNC 99%
13MAR 19:59:--
STATUS
SYNC.SOURCE
SPEC.-FUNCTIONS
STATUS
SPEC.-FUNCTIONS

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
17 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Status sync. source
Status impulse output
IL=0.5
12:00 UF=26 V
U=
--
V
Impulse current
Impulse voltageSlave Clock time
1/! MIN SYNC 99%
01 MAY 12:00:--
% of accepted messages
Last synchronisation was 1MAY12:00
Type of synchronisation

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
18 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Keylock
With this function it is possible to lock the keyboard. When activated the keylock will lock all buttons in the
Impulse Amplifier.
There are two levels of keyboard protection.
1. Low level protection
Keylock ON : Keyboard locked, press ←YES to open.
2. High level protection
Keylock with Password : Keyboard locked, enter password to open.
Remark: “PASSWORD –-“ means that no password is used
Example 1:
Activate keylock without password
Select function using ↓.
Accept with YES.
Press NO until wished function is shown.
Accept with YES.
Change to keylock ON.
Accept with YES.
Accept with YES.
Return to running mode press ←.
MON 14 MAR 2011
09:07:00 LTw
SPEC.-FUNCTIONS
SPEC.-FUNCTIONS
KEYLOCK
KEYLOCK
OFF
PASSWORD --
KEYLOCK
ON
PASSWORD --
KEYLOCK ON
PASSWORD --
SPEC.-FUNCTIONS
KEYLOCK
MON 14 MAR 2011
09:07:00 LTw

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
19 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Example 2:
Activate keylock with password
Select function using ↓.
Accept with YES.
Press NO until wished function is shown.
Accept with YES.
Change to keylock ON.
Accept with YES.
Enter, by using the arrows, a 2-digit password.
Accept with YES.
Return to running mode press ←.
MON 14 MAR 2011
09:07:00 LTw
SPEC.-FUNCTIONS
SPEC.-FUNCTIONS
KEYLOCK
KEYLOCK
OFF
PASSWORD --
KEYLOCK
ON
PASSWORD --
KEYLOCK ON
PASSWORD 99
SPEC.-FUNCTIONS
KEYLOCK
MON 14 MAR 2011
09:07:00 LTw

Document:
1904en01.doc
QWTIME III IMPULSE AMPLIFIER
Author:
PM
D te:
2011-02-03
User Manual
P ge:
20 o f 28
WESTERSTRAND URFABRIK AB
P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstr nd.se
Language
With this function the language be selected.
Example:
Select function using ↓.
Accept with YES.
Press NO until wished function is shown.
Accept with YES.
Select, by using the arrows, the wished language.
Accept with YES.
Return to running mode press ←.
MON 14 MAR 2011
09:07:00 LTw
SPEC.-FUNCTIONS
SPEC.-FUNCTIONS
LANGUAGE
LANGUAGE
ENGLISH?
MON 14 MAR 2011
09:07:00 LTw
SPEC.-FUNCTIONS
LANGUAGE
Table of contents
Other WESTERSTRAND Amplifier manuals
Popular Amplifier manuals by other brands

Pioneer
Pioneer VSA-E03 Service manual

ATI Technologies
ATI Technologies AT1202 owner's guide

Smart-M
Smart-M StretcherPro-HD installation manual

Harman
Harman JBL CSA 1300Z Operation manual

VocoPro
VocoPro DA-3900K operating instructions

Krell Industries
Krell Industries Phone Preamplifier Specification sheet