2271-100 HUMIDISTAT
The humidistat is designed for either return air duct or wall mounting.
Packaged in a duct mount configuration, (For this type mounting begin
installation at the section labeled return air duct installation on
page 2.) for conversion to a wall mount configuration simply pull off the
knob and remove the mounting screws and rotate the control 180° and
reattach the mounting base, (For this type mounting begin installation
at the section labeled wall mount installation on page 3.).
k
!DANGER
*Do not cut or drill into any air-conditioning or electri-
cal accessories during installation.
*Fatal electrocution is possible if you contact a live
wire.
*Electrical power can cause electrical shock.
*Disconnect all electrical power supplied to the
equipment before beginning installation.
*Blindness can occur if freon contacts your eyes.
k
!CAUTION
*Do not install on any electrical system over 30 VAC.
k
!CAUTION
*All electrical wiring should comply with codes and
ordinances.
Recommended Settings
At Outside Temperatures Recommended Setting
-20°F -30°C 15% (Low)
-10°F -25°C 20% (Low)
0°F -20°C 25% (Med)
+10°F -10°C 30% (Med)
+20°F -5°C 35% (High)
Over 20°F Over 0°C 40% (High)
k
!WARNING:
Adjusting the
humidity control
higher than the rec-
ommended setting
may cause conden-
sation resulting in
possible damage to
the home.
WIRING INSTRUCTIONS
k
!CAUTION:
*Use the wiring diagram shown for single-speed blower operation
only.
*When wiring multi-speed blower systems use an A50 relay or a fan
sail switch to prevent premature component failure.
*Consult the instructions included with the humidifier and any
additional controls for instructions on wiring.
*Fatal electrocution is possible if you contact a live wire.
*Electrical power can cause electrical shock.
*Disconnect all electrical power supplied to the equipment before
beginning installation.
*All electrical wiring must comply with codes and ordinances.
k
!Caution: When wiring a
Model HFT2900FP or a
Steam Humidifier Consult
the Units wiring diagram.
These Units Don’t require
an additional transformer.
OPERATIONS CHECK
1Turn the heating system thermostat up and wait until the system
blower activates.
2Turn the humidistat clockwise to the on position; visually check
humidifier for operation.
3Turn the humidistat counterclockwise to 10% or lower; visually
check to see that humidifier shuts off.
Note: The set point where the humidistat turns on and off may not
represent the actual indoor relative humidity, due to storage and
transport environments. Allow at least 24 hours for humidity control
to adjust to the installation.
4Turn the humidistat to the recommended setting for operation (see
the recommended settings chart on page 1).
5Turn the system thermostat back to normal operation.
k
!WARNING: Adjusting the humidity control higher than the
recommended setting may cause condensation resulting in possible
damage to the home.
HBP Rev. 10/02 PN/000-0756-312
Figure 3: Wiring Diagram