Each Sirocco Park luminaire is shipped in one
single package. Before commencing
installation, check the contents of the carton
to ensure that all the components are present
and in good condition.
1) Main body
2) IP66 plug set
3) Gland kit
INSTALLATION SEQUENCE
In order to fit this luminaire, the correct sequence of
assembly must be observed. During installation make sure
the power supply is completely isolated from the mains.
Refer to general information overleaf before installation.
1. Carefully unpack the luminaire and locate the plug
kit and gland kit.
2. Prepare the body for installation in the correct
orientation –on a vertical post or horizontal bracket.
Remove and re-fit the mounting socket if necessary.
(fig 1) If additional electrical feeds are required for
Dali control, fit the supplied gland into the body
mounting socket at this stage. (fig 2)
3. Fit the IP66 plug supplied to the incoming supply
flex. (fig 3) Supply flex must be round and Ø9-
12mm.
4. Plug the supply into the flying lead attached to the
luminaire. Ensure that the connectors are locked
together by rotating the locking ring.
5. If Dali feeds are to be used, they must be passed
through the gland into the body. The luminaire can
be opened via 4 off 4mm hex screws from above.
Make Dali connections directly to the labelled
terminal blocks. Close the luminaire ensuring that
the IP seal is free from obstructions.
6. Fit the luminaire onto the mounting post/bracket and
tighten the securing grub-screws to 8Nm. (fig 4)
NB. If a photocell is fitted, the luminaire will not switch on
in daylight. Cover the sensor to simulate darkness to
verify operation.
The Sirocco Park and Sirocco Flood are Exterior Street lighting
luminaires available in a choice of light distributions and power
levels. See www.Whitecroft light.com for full specifications of the
entire range.
Nom. mounting column/bracket diameter: Ø60mm
Max mounting column/bracket diameter: Ø63mm
Body finish: Anthracite
Factory-fitted Photocell switching: On 70 lux/Off 105 lux.