Whitehall E-27-S Operation and maintenance manual

E-27-S S-90-S
6900-194-000
INSTRUCTIONS FOR
OPERATION AND CARE OF
(Stationary Whirlpool)
Member of
Revised: February 2016

! !
PLEASE READ THIS ENTIRE
BOOKLET BEFORE OPERATING
YOUR NEW WHIRLPOOL
Failure to follow these instructions could result in damage
to your new whirlpool and/or bodily injury
4
34
3
ŸWHIRLPOOLS intended for professional use only.
Ÿ220v WHIRLPOOLS for export only.
ŸDO NOT operate appliance without properly filling with water. Under no conditions should the appliance be operated
without water. Fill appliance with water to the prescribed level before plugging into an electrical receptacle. Operating the
appliance without water may result in damage to the motor.
ŸIMPROPER USE of the whirlpool can cause injury. Use the whirlpool only for the purpose described in this manual.
ŸTHE TURBINE is top-heavy. Improper handling can cause injury or damage. Handle the turbine with care.
ŸATTACHING IMPROPER items to the whirlpool can cause injury to persons and damage to equipment. Use only Whitehall
approved items on the whirlpools.
ŸINCORRECT PARTS and service can cause injury to persons and damage equipment. Use only Whitehall parts and
Whitehall approved service on whirlpools.
a
European Union CE Mark
The presence of the CE Mark on Whitehall equipment means that it has been designed, tested and certified as complying
with all applicable European Union regulations and recommendations.
Waste Electrical and Electronic Equipment (WEEE)
This symbol on the product or on its packaging indicates that this product must not be disposed of with regular waste.
Instead, it is the user’s responsibility to dispose of waste equipment according to the local laws. Separate collection and
recyc ling of the waste equipment at the time of disposal will help conserve natural resources and ensure it is recycled in a
manner that protects human health and the environment. For information about where the user can drop off the waste
equipment for recycling, please contact your local waste collection authority. See Page 30 for instructions on how to
disassemble the equipment for recycling purposes.
General Warning or Caution
The Exclamation Symbol appears in Warning and Caution statements. This symbol designates where personal injury or
damage to the equipment is possible.
Electric Shock
The Electric Shock Symbol is used to indicate a hazard arising from dangerous voltage. Any mishandling could result in
irreparable damage to the equipment and/or personal injury or death.
WARNING
To avoid electric shock, connect the instrument to properly earth-grounded, GFCI protected, 3-prong
receptacles only. Failure to observe this precaution can result in severe injury.

1
Table of Contents
Warning ................................................................................................................................................Page a
Table of Contents .................................................................................................................................Page 1
General Knowledge..............................................................................................................................Page 2
Operating Skills & Training ..........................................................................................................Page 2
Patient Evaluation .......................................................................................................................Page 2
Inspecting Whirlpool ....................................................................................................................Page 2
Using The Whirlpool .............................................................................................................................Page 3
Installation & Operation ...................................................................................................................Pages 4-8
Fixture Installation Location Guide..............................................................................................Page 4
Stationary Style Hydrotherapy Whirlpool Dimensions.................................................................Page 5
Combined Drain / Overflow .........................................................................................................Page 6
Separate Drain / Overflow...........................................................................................................Page 7
Slant Back ...................................................................................................................................Page 8
Repair Parts .................................................................................................................................Pages 9-27
Stationary Motor/Turbine Assembly.............................................................................................Page 9
Stationary "E" Series .................................................................................................................Page 10
Stationary "H" Series .................................................................................................................Page 11
Stationary "L" Series..................................................................................................................Page 12
Stationary "P" Series .................................................................................................................Page 13
Stationary "S" Series .................................................................................................................Page 14
Motor Raising & Lowering Assembly (Small).............................................................................Page 15
Motor Raising & Lowering Assembly ........................................................................................Page 16
Motor Raising & Lowering Assembly (Slant Back) ....................................................................Page 17
Drain / Overflow Assembly - H/S Series ....................................................................................Page 18
Drain / Overflow Assembly - "E" Series .....................................................................................Page 19
Drain / Overflow Assembly - (Lo-Boy) .......................................................................................Page 20
Drain / Overflow Assembly - Podiatry Series.............................................................................Page 21
Drain / Overflow Assembly - Slant Back ....................................................................................Page 22
Separate Drain / Overflow Assembly - P-10, P/E-15/22 ............................................................Page 23
Separate Drain / Overflow Assembly - E-22-SP, E-27/45..........................................................Page 24
Separate Drain / Overflow Assembly - H-60/70/90, S-85/90 .....................................................Page 25
Butterfly Drain Valve ..................................................................................................................Page 26
Thermometers ...........................................................................................................................Page 27
Cleaning & Disinfecting ....................................................................................................................Pages 28
Care & Cleaning ...............................................................................................................................Pages 29
Maintenance & Troubleshooting .......................................................................................................Pages 30
Motor Information .............................................................................................................................Pages 31

General Knowledge
2
TRAINING
Operator trainees need to:
Ÿbe trained in aquatic-therapy protocols.
Ÿbe familiar with the types of patients who should or
should not receive this type of physical therapy (see
Patient Evaluation, below).
Ÿread and understand this manual (and the manual for
the turbine, if used).
Ÿbe trained on the use of the whirlpool (and turbine, if
used).
Ÿpractice with the whirlpool (and turbine, if used) before
use with patient.
OPERATOR SKILLS AND TRAINING
Skills:
Operators using the whirlpool need:
Ÿa working knowledge of aquatic physical-therapy
procedures.
Ÿthe ability to assist the patient.
PATIENT EVALUATION
Require Each Patient To Be Evaluated
or patients with
certain other medical, mental or physical conditions should
not receive treatment with the whirlpool.
The trained operator must evaluate and verify that each
patient is suitable for hydrotherapy treatment before
permitting the patient to begin hydrotherapy. If in doubt,
consult a medical professional before providing
hydrotherapy treatment.
Patients who are electrically-susceptible (patients with
exposed, non-waterproof electric leads, monitors, etc.),
patients carrying infectious disease,
WARNING
!
INSPECTING THE WHIRLPOOL
Have your facility's equipment maintenance personnel
inspect the whirlpool regularly. Follow the checklist at right
and operate the whirlpool through all its functions as
described in this manual.
Inspection Checklist
Are all components present?
Is the whirlpool free of excessive wear?
Does the turbine mount securely in place?
Is a properly-grounded and voltage-matched
hospital grade receptacle available for the turbine?
Is the outlet or turbine cord equipped with a
functioning GFI (or RCD)?
Can the turbine be raised, lowered and locked at the
desired height?
Does the drain valve open and close properly?
Is the thermometer present and is it legible?
Do the installed accessories operate without
interfering with whirlpool use or turbine operation?
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Important
BLOODBORNE DISEASE NOTICE: To reduce the
risk of exposure to bloodborne diseases such as HIV-1
and hepatitis when using the whirlpool, read and
follow the disinfecting and cleaning instructions in this
manual thoroughly.
Certain medical conditions are incompatible with
hydrotherapy. The trained operator is responsible for
determining each user’s suitability for hydrotherapy
before beginning treatment.
WARNING
!
WARNING
!
Untrained operators can cause injury or be injured.
Permit only trained personnel should operate the
whirlpool.
WARNING
!
This Whitehall product has been carefully packaged at the
factory to minimize the possibility of damage during
shipping.
— Inspect the packaging for external signs of damage.
— Inspect the contents for damage.
If there is visible damage to the instrument upon receipt,
inform the shipping company and Whitehall immediately.
WARNING
!
Do not attempt to operate this equipment if there is
evidence of shipping damage or you suspect the unit
is damaged. Damaged equipment may present
additional hazards to you. Contact Whitehall technical
support for advice before attempting to plug in and
operate damaged equipment.
WARNING
!

Using The Whirlpool
3
USING THE WHIRLPOOL
Before Placing the Whirlpool In Service:
Operators using the whirlpool need:
ŸPersonnel who will work with the whirlpool need to read
this manual.
ŸHave a plumbing professional install the whirlpool as
instructed in page 4. A rough-in
drawing is available to assist the installer. Contact
Whitehall Customer Service, bottom of page, for
additional installation not covered in this manual.
ŸConfirm that the whirlpool operates properly. See
Inspecting the Whirlpool , page 2.
Installing the Whirlpool,
General Guidelines for Use:
ŸMedical advice is beyond the parameters of this
manual.
ŸThe whirlpool is for professional use only. A minimum of
one trained operator is required.
ŸThe trained operator must evaluate and verify that the
patient is suitable for hydrotherapy treatment before
beginning hydrotherapy with whirlpool. See Patient
Evaluation, page 2.
ŸFollow your state and local hydrotherapy procedures
and, if the patient has one, the physician's order for
treatment (see Patient Evaluation, page 2).
ŸStay with patient at all times.
ŸIt is the operators responsibility to ensure safe practices
for the patient and themselves.
ŸIf a turbine is used:
Plug the turbine cord only into a receptacle that is
voltage-matched, properly grounded and polarized.
Verify that the receptacle has GFI protection or order a
GFCI plug for the turbine cord.
Keep patient hair, gown strings and other loose items
away from the impeller housing to avoid entanglement
and injury.
Keep the area around the turbine clear. The turbine
requires a minimum of 24" (610mm) of clearance.
ŸAvoid prolonged contact with the motor cover, as elevated
temperatures can cause discomfort.
ŸAmbient temperatures during use should not exceed
95°F (35°C).
WARNING
!
Certain medical conditions are incompatible with
hydrotherapy. The trained operator is responsible for
determining each user's suitability for hydrotherapy
before beginning treatment.
Improper operation can cause injury. Operate the
whirlpool only as described in this manual.
An unattended patient can be injured. Stay with
patient at all times.
Loose items such as gown straps or gauze can be
pulled into the turbine impeller and cause injury. Keep
loose items away from the turbine impeller housing.
Important
Communicate with patient at all times. If a turbine is
used, tell the patient before starting or stopping the
turbine and before changing the water or aeration
level.

Fixture Installation Location Guide
4
9
'L'-CLIPS FOR FLOOR MOUNTING
8
7
6
5
4
3
2
1
FURNISHED BY WHITEHALL
2" COMBINATION DRAIN AND OVERFLOW ASSEMBLY
OPTIONAL -MXWH (HA-WASHOUT ASSEMBLY)
2" DRAIN
HOT & COLD WATER INLET
OVER RIM INLET
2" x 5" TAIL PIECE FURNISHED WITH UNIT
THERMOSTATIC MIXING VALVES ARE OPTIONAL
AT WALL PROVIDE ONE 3 POLE RECEPTACLE HOSPITAL
ELECTRICAL REQUIREMENTS: 8 AMPS, 115 VOLTS.
GRADE WITH GROUND FAULT INTERRUPT FOR TURBINE
12"
(305)
REC. MIN.
12"
(305)
REC. MIN.
B
521
4"
(1327)
521
4"
(1327)
B
43
4"
(120)
A
1
ASSEMBLY
2
3
4
5
6
7
8
9
DIMENSION DESCRIPTION
MXT2 (MV2) 3/4" NPT
DISTANCE FOR:
A
VALVE = 9-1/2"
MXT1 (MV1) 1/2" NPT
VALVE = 8-1/2"
VALVE = 13-3/4"
MXT1 (MV1) 1/2" NPT
VALVE = 13-1/2"
B
DISTANCE FOR:
MXT2 (MV2) 3/4" NPT
D
OH
CW
L
CD
W
L = LENGTH (ID)
W = WIDTH (ID)
D = DEPTH (ID)
OH = OVERALL HEIGHT
CW = CENTER OF TANK TO WALL
CD = CENTER OF DRAIN TO WALL
REFER TO PAGE 5 FOR DIMENSIONS
11"
(279)

Stationary Style Hydrotherapy Whirlpool Dimensions
5
Refer to Page 4 for Layout Information.
P-10-S 22/559 13/330 12/305 18/457 23/584 26.5/673 1/2" IPS
P-15-S 25/635 13/330 15/381 21/533 25.5/648 26.5/673 1/2" or 3/4" IPS
P-22-S 28/711 15/381 18/457 24/610 26/660 26.5/673 1/2" or 3/4" IPS
E-15-S 25/635 13/330 15/381 21/533 25.5/648 26.5/673 1/2" or 3/4" IPS
E-22-S 28/711 15/381 18/457 24/610 26/660 26.5/673 1/2" or 3/4" IPS
E-22-SP 28/711 15/381 18/457 34/864 20/508 26.5/673 1/2" or 3/4" IPS
E-27-S 28/711 15/381 21/533 27/686 26/660 26.5/673 1/2" or 3/4" IPS
E-36-S 28/711 15/381 25/635 32/813 26/660 26.5/673 1/2" or 3/4" IPS
E-45-S 32/813 15/381 25/635 31/787 28/711 26.5/673 1/2" or 3/4" IPS
H-60-S 36/914 20/508 28/711 34/864 30/762 29/737 1/2" or 3/4" IPS
H-75-S 42/1067 20/508 28/711 34/864 33/838 29/737 1/2" or 3/4" IPS
H-90-S 48/1219 20/508 28/711 34/864 36/914 29/737 1/2" or 3/4" IPS
H-105-S 48/1219 24/610 28/711 34/864 26/660 31/787 1/2" or 3/4" IPS
L-75-S 52/1321 24/610 18/457 24/610 38/965 31/787 1/2" or 3/4" IPS
L-90-S 60/1524 24/610 18/457 24/610 42/1067 31/787 1/2" or 3/4" IPS
L-105-S 66/1676 24/610 18/457 24/610 45/1143 31/787 1/2" or 3/4" IPS
S-85-S 48/1219 20/508 25/635 31/787 36/914 29/737 1/2" or 3/4" IPS
S-85-SL 48/1219 20/508 25/635 35/889 17/432 N/A 1/2" or 3/4" IPS
S-90-S 46/1168 24/610 25/635 31/787 35/889 31/787 1/2" or 3/4" IPS
S-90-SL 46/1168 24/610 25/635 35/889 17/432 N/A 1/2" or 3/4" IPS
S-110-S 56/1422 24/610 25/635 31/787 40/1016 31/787 1/2" or 3/4" IPS
S-110-SL 56/1422 24/610 25/635 35/889 17/432 N/A 1/2" or 3/4" IPS
PIPE SIZE FOR
VALVE
Whitehall
Model Number
L DIM
Inches/MM
W DIM
Inches/MM
D DIM
Inches/MM
OH DIM
INCHES/M
CW DIM
INCHES/M
CD DIM
INCHES/M

WARNING
Turbine assembly is provided with a 3-way plug. The
third prong functions as a built-in ground and must be
plugged into a matching grounded receptacle to
properly ground the product.
WARNING
NOTE: THESE INSTALLATION
INSTRUCTIONS ARE USED FOR
ALL WHITEHALL OR DAKON
STATIONARY ALL MODELS.
COMPLETELY LUBRICATE THE PLUNGER ASSEMBLY.
E-
CLOCKWISE, THEN FULLY COUNTERCLOCKWISE TO
HANDLE 5 . INTERNAL BUSHING MAY NEED ADJUSTMENT.
7
B-
A-
LEVEL OF AGITATION AND PRESSURE.
E-
UNTIL THE PUMP 12 IS AT THE DESIRED LOCATION. TIGHTEN
PUSHING DOWN ON TOP OF THE MOTOR SUPPORT CASTING 14
D-
C-
CLOCKWISE, THIS PROVIDES MAX PRESSURE AND AGITATION.
B-
WATER LEVEL SHOULD BE A MAXIMUM OF 4" BELOW THE RIM
A-
INTO LOWER BRACKET 9 , TIGHTEN SCREW 10 .
D-
ASSEMBLY 4 AND TIGHTENING HANDLE 5 .
MOTOR SUPPORT ROD 6 INTO RAISING AND LOWERING
LOWERING ASSEMBLY 4 BY LOOSENING HANDLE 5 , SLIDING
C-
A-
(SEE DETAIL A) NOTE: FOR INFORMATION ON OPTIONAL
THERMOSTATIC MIXING VALVE CONTACT FACTORY.
B-
2
10
3
4
5
6
9
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
LIFT COMBINATION DRAIN & OVERFLOW ASSEMBLY HANDLE 15 .
TURN OFF SWITCH 13 .
ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED
ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY
TURN ON THE SWITCH 13 .
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
FILL TUB AS DESIRED USING THERMOSTATIC MIXING VALVE.
INSTALL THERMOMETER 7 THRU UPPER BRACKET 8 AND
INSTALL MOTOR/TURBINE ASSEMBLY 3 INTO RAISING AND
ROUGH-IN FOR 2" OD DRAIN LINE 1 AND WATER INLET VALVE.
LOCATE TANK AND SECURE WITH "L" BRACKETS 2 , WITH
8
F-
REFERENCE DRAWINGS
ASSEMBLIES
RAISING/LOWERING/SM
MOTOR/TURBINE 9
15
PAGE NUMBER
19
18
DRAIN OVERFLOW E
DRAIN OVERFLOW H/S
5"
21
4"
3
4"1"
PROVIDE ELECTRICAL SERVICE AND PROPERLY INSTALLED,
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) FOR MOTOR
SPECIFIED. MOTOR SPECIFICATIONS AVAILABLE ARE EITHER
120V AC / 60 HZ ON 15A CIRCUIT OR 240 V AC / 50 HZ ON 10A
AND A MINIMUM OF 6" ABOVE BOTTOM PUMP 12 .
ASSEMBLY PROCEDURE:
OPERATION PROCEDURE:
DRAINING PROCEDURE:
INSTALLER PROVIDED FLOOR ANCHORS AND ANCHORING
HARDWARE. MAKE WASTE CONNECTIONS 1 .
1
1
11
12
13
14
15
DETAIL "A"
(TOP VIEW)
C
L
RAISING/LOWERING 16
DRAIN OVERFLOW - L
21DRAIN OVERFLOW - P
20
THERMOMETER 27
6
Installation Instructions

Installation Instructions; -SDO Separate Drain Overflow
WARNING
Turbine assembly is provided with a 3-way plug. The
third prong functions as a built-in ground and must be
plugged into a matching grounded receptacle to
properly ground the product.
WARNING
NOTE: THESE INSTALLATION
INSTRUCTIONS ARE USED FOR
ALL WHITEHALL OR DAKON
ALL STATIONARY -SDO MODELS.
COMPLETELY LUBRICATE THE PLUNGER ASSEMBLY.
E-
CLOCKWISE, THEN FULLY COUNTERCLOCKWISE TO
HANDLE 5 . INTERNAL BUSHING MAY NEED ADJUSTMENT.
7
B-
A-
LEVEL OF AGITATION AND PRESSURE.
E-
UNTIL THE PUMP 12 IS AT THE DESIRED LOCATION. TIGHTEN
PUSHING DOWN ON TOP OF THE MOTOR SUPPORT CASTING 14
D-
C-
CLOCKWISE, THIS PROVIDES MAX PRESSURE AND AGITATION.
B-
WATER LEVEL SHOULD BE A MAXIMUM OF 4" BELOW THE RIM
A-
INTO LOWER BRACKET 9 , TIGHTEN SCREW 10 .
D-
ASSEMBLY 4 AND TIGHTENING HANDLE 5 .
MOTOR SUPPORT ROD 6 INTO RAISING AND LOWERING
LOWERING ASSEMBLY 4 BY LOOSENING HANDLE 5 , SLIDING
C-
A-
(SEE DETAIL A) NOTE: FOR INFORMATION ON OPTIONAL
THERMOSTATIC MIXING VALVE CONTACT FACTORY.
B-
2
10
3
4
5
6
9
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
TURN HANDLE 15 CLOCKWISE TO OPEN DRAIN VALVE 16 .
TURN OFF SWITCH 13 .
ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED
ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY
TURN ON THE SWITCH 13 .
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
FILL TUB AS DESIRED USING THERMOSTATIC MIXING VALVE.
INSTALL THERMOMETER 7 THRU UPPER BRACKET 8 AND
INSTALL MOTOR/TURBINE ASSEMBLY 3 INTO RAISING AND
ROUGH-IN FOR 2" OD DRAIN LINE 1 AND WATER INLET VALVE.
LOCATE TANK AND SECURE WITH "L" BRACKETS 2 , WITH
8
F-
REFERENCE DRAWINGS
ASSEMBLIES
RAISING/LOWERING/SM
MOTOR/TURBINE 9
15
PAGE NUMBER
24
25
DRAIN OVERFLOW E
DRAIN OVERFLOW H/S
PROVIDE ELECTRICAL SERVICE AND PROPERLY INSTALLED,
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) FOR MOTOR
SPECIFIED. MOTOR SPECIFICATIONS AVAILABLE ARE EITHER
120V AC / 60 HZ ON 15A CIRCUIT OR 240 V AC / 50 HZ ON 10A
AND A MINIMUM OF 6" ABOVE BOTTOM PUMP 12 .
ASSEMBLY PROCEDURE:
OPERATION PROCEDURE:
DRAINING PROCEDURE:
INSTALLER PROVIDED FLOOR ANCHORS AND ANCHORING
HARDWARE. MAKE WASTE CONNECTIONS 1 .
1
1
11
12
13
14
15
DETAIL "A"
(TOP VIEW)
C
L
RAISING/LOWERING 16
23DRAIN OVERFLOW - P
THERMOMETER 27
31
2"
1"
3
4"
77
8"
16
Installation Instructions; -SDO Separate Drain Overflow
7

WARNING
Turbine assembly is provided with a 3-way plug. The
third prong functions as a built-in ground and must be
plugged into a matching grounded receptacle to
properly ground the product.
WARNING
COMPLETELY LUBRICATE THE PLUNGER ASSEMBLY.
E-
CLOCKWISE, THEN FULLY COUNTERCLOCKWISE TO
HANDLE 5 . INTERNAL BUSHING MAY NEED ADJUSTMENT.
B-
A-
LEVEL OF AGITATION AND PRESSURE.
E-
UNTIL THE PUMP 12 IS AT THE DESIRED LOCATION. TIGHTEN
PUSHING DOWN ON TOP OF THE MOTOR SUPPORT CASTING 14
D-
C-
CLOCKWISE, THIS PROVIDES MAX PRESSURE AND AGITATION.
B-
WATER LEVEL SHOULD BE A MAXIMUM OF 4" BELOW THE RIM
A-
INTO LOWER BRACKET 9 , TIGHTEN SCREW 10 .
D-
ASSEMBLY 4 AND TIGHTENING HANDLE 5 .
MOTOR SUPPORT ROD 6 INTO RAISING AND LOWERING
LOWERING ASSEMBLY 4 BY LOOSENING HANDLE 5 , SLIDING
C-
A-
(SEE DETAIL A) NOTE: FOR INFORMATION ON OPTIONAL
THERMOSTATIC MIXING VALVE CONTACT FACTORY.
B-
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
LIFT COMBINATION DRAIN & OVERFLOW ASSEMBLY HANDLE 15 .
TURN OFF SWITCH 13 .
ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED
ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY
TURN ON THE SWITCH 13 .
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
FILL TUB AS DESIRED USING THERMOSTATIC MIXING VALVE.
INSTALL THERMOMETER 7 THRU UPPER BRACKET 8 AND
INSTALL MOTOR/TURBINE ASSEMBLY 3 INTO RAISING AND
ROUGH-IN FOR 2" OD DRAIN LINE 1 AND WATER INLET VALVE.
LOCATE TANK AND SECURE WITH "L" BRACKETS 2 , WITH
F-
REFERENCE DRAWINGS
ASSEMBLIES
RAISING/LOWERING
MOTOR/TURBINE 9
17
PAGE NUMBER
27
DRAIN OVERFLOW
PROVIDE ELECTRICAL SERVICE AND PROPERLY INSTALLED,
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) FOR MOTOR
SPECIFIED. MOTOR SPECIFICATIONS AVAILABLE ARE EITHER
120V AC / 60 HZ ON 15A CIRCUIT OR 240 V AC / 50 HZ ON 10A
AND A MINIMUM OF 6" ABOVE BOTTOM PUMP 12 .
ASSEMBLY PROCEDURE:
OPERATION PROCEDURE:
DRAINING PROCEDURE:
INSTALLER PROVIDED FLOOR ANCHORS AND ANCHORING
HARDWARE. MAKE WASTE CONNECTIONS 1 .
22
THERMOMETER
67
8"
17"
TYP.
11
4"
TYP.
121
8"
13
11
12
6
14
3
15
5
4
1
2
7
8
10
9
DETAIL "A"
(TOP VIEW)
Installation Instructions; Slant Back
8

NOTE: SEE ADDITIONAL DRAWINGS FOR
COMPLETE ASSEMBLY NUMBERS AND
DETAIL OF ITEMS NOT LISTED.
STATIONARY ''E'' SERIES
STATIONARY ''SB'' SERIES
STATIONARY ''L'' SERIES
STATIONARY ''P'' SERIES
STATIONARY ''S'' SERIES
E-15-S
E-22-S
E-22-SP
E-27-S DF-2821
DF-2516
DF-2818
H-90-S
H-75-S
H-60-S
E-45-S
DF-3628
DF-3225
L-75-S
H-105-S DF-4828
L-90-S DF-6018
P-10-S
L-105-S DF-6618
P-15-M-SDP DD-2516
S-85-M-SDP
P-22-M-SDP DD-2818
S-90-M-SDP
S-110-S DFT-5625
E-36-S DF-2825
DDT-4825
2
28
1
3
29
7
8
9
13
14 15
16
18
19
21
22
23
24
25
26
20
10
11
17A - 17H
6
27
5
4
12
L-90-SL
L-105-SL
WHITEHALL MODEL
NUMBERS
THESE REPAIR PARTS ARE USED FOR THE
FOLLOWING MODEL NUMBERS ONLY:
DAKON
MODEL NUMBERS
WHITEHALL MODEL
NUMBERS
DAKON
MODEL NUMBERS
S-110-M-SDP DDT-5625
S-85-S
S-90-S
DFT-4825
P-15-S DF-2516
P-22-S DF-2818
L-75-M-SDP
L-90-M-SDP DD-6018
L-105-M-SDP DD-6618
H-90-M-SDP
H-75-M-SDP
H-60-M-SDP DD-3628
H-105-M-SDP DD-4828
E-15-M-SDP
E-22-M-SDP
E-27-M-SDP DD-2821
DD-2516
DD-2818
E-45-M-SDP
E-36-M-SDP DD-2825
1 6502-307-000 #8-32 x 1/2" PHIL FLAT HD SELF TAPPING
2 6504-501-199 17" PUMP GASKET
3 6525-518-000 TURBINE IMPELLER - PLASTIC
4 0341-101-000 COTTER PIN
5 6502-401-000 1/4"-20 x 5/16" HEX SOCKET SET SCREW
6 6502-042-000 1/4"-20 x 5/8" PHIL PAN HEAD SCREW
7 6502-300-000 #8-32 x 3/8" PHIL FLAT HEAD SELF TAPPING
8 6525-514-199 SHAFT BEARING
9 6502-410-000 1/4"-20 x 1/4" DOG SET SCREW
10 6502-352-000 3/8"-16 x 3" HEX CAP SCREW
11 6502-402-000 5/16"-16 x 1/4" HEX SOCKET SET SCREW
12 6502-020-001 CONDENSER ASSEMBLY
13 6525-600-000 PLASTIC MOTOR COVER
14 6505-025-000 DPST TOGGLE SWITCH
15 6505-035-000 WATERPROOF TOGGLE SWITCH CAP
16 6502-452-000 3/8"-16 x 3/4" HEX SOCKET CAP SCREW
17A 6505-030-000 10 FEET, 115VAC, 60Hz POWER CORD
18 6525-513-199
19 6525-584-199 HANDLE
20 6531-112-199 TENSION ADJUSTER
21 6531-111-199 FRICTION LOCK ROD
22 6531-113-000 SPRING
23 6525-570-199 AIR RING BRACKET
24 6502-620-000 1-3/8" RETAINING RING
25 6504-022-000 O-RING
26 6502-413-000 1/4"-20 x 5/16" DOG SETR SCREW
27 6525-509-001 PUMP BODY / COVER ASSEMBLY
28 6525-509-299 PUMP COVER
29 6525-510-299 PUMP BODY
ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
Page 10
Page 10
Page 12
Page 13
Page 14
17B 6505-034-001 DOMESTIC POWER CORD 220VAC, 60Hz
17C 6505-044-001 RUSSIAN POWER CORD, 250VAC, 50Hz
17D 6505-074-001 INDIA/S. AFRICA POWER CORD, 230VAC, 50Hz
17E 6505-043-001 EUROPEAN POWER CORD, 250 VAC, 50Hz
17F 6505-073-001 UK POWER CORD, 230VAC, 50Hz
17G 6505-070-001 ISRAEL POWER CORD, 250VAC, 50Hz
17H 6505-071-001 AUSTRALIAN POWER CORD, 250VAC 50Hz
SHAFT COUPLING
SB-100-S
STATIONARY ''H'' SERIES Page 11
Stationary Motor/Turbine Assembly
9

ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
4A 4B
1A 1M
THRU
2C 2D
2B2A
7A 7B
7D7C
6D
6B6A
6C
5C
5A 5B
5D
3D
3B3A
3C
*NOTE: SEE ADDITIONAL DRAWING FOR DETAIL
OF ITEMS NOT SHOWN.
STATIONARY MOTOR/TURBINE - PAGE 9
*
E-15-S
E-22-S
E-22-SP
WHITEHALL MODEL
NUMBERS
THESE REPAIR PARTS ARE USED
FOR THE FOLLOWING MODEL
NUMBERS ONLY:
E-27-S
DAKON
MODEL NUMBERS
DF-2821
DF-2516
DF-2818
E-45-S
E-36-S DF-2825
DF-3225
E-15-M-SDP
E-22-M-SDP
DD-2516
DD-2818
E-45-M-SDP
E-27-M-SDP DD-2821
1A 6525-105-001 TURBINE ASSY - E-15, 115VAC, 60Hz
1B 6525-106-001 TURBINE ASSY - E-15, 230VAC, 60Hz
1C 6525-107-001 TURBINE ASSY - E-15, 230VAC, 50Hz
1D 6525-108-001 TURBINE ASSY - E-22, 115VAC, 60Hz
1E 6525-109-001 TURBINE ASSY - E-22, 230VAC, 60Hz
1F 6525-110-001 TURBINE ASSY - E-22, 230VAC, 50Hz
1G 6525-161-001 TURBINE ASSY - E-27, 115VAC, 60Hz
1H 6525-162-001 TURBINE ASSY - E-27, 230VAC, 60Hz
1J 6525-163-001 TURBINE ASSY - E-27, 230VAC, 50Hz
1K 6525-165-001 TURBINE ASSY - E-45, 115VAC, 60Hz
1L 6525-166-001 TURBINE ASSY - E-45, 230VAC, 60Hz
1M 6525-167-001 TURBINE ASSY - E-45, 230VAC, 50Hz
2A 6525-525-001 PLUNGER ASSY - 12" - E-15-S
2B 6525-528-001 PLUNGER ASSY - 15-1/4" - E-22-S
2C 6525-531-001 PLUNGER ASSY - 16-1/2" - E-27-S
2D 6525-535-001 PLUNGER ASSY - 20" - E-45-S
3A
6525-201-001 MOTOR ASSY - 115VAC, 60Hz - E-15/223B
6525-210-001 MOTOR ASSY - 230VAC, 60Hz - E-15/22/27/45-S3C
6525-220-001 MOTOR ASSY - 230VAC, 50Hz - E-15/22/27/45-S3D
6525-200-001 MOTOR ASSY - 115VAC, 60Hz - E-27/45-S
6525-500-199 3/4" MOTOR BASE CASTING - E-15/22-S4A
6525-500-299 1" MOTOR BASE CASTING - E-27/45-S4B
6509-560-199 3/4" DIA. x 13" ROD - E-155A
6509-565-199 3/4" DIA. x 16" ROD - E-225B
6509-160-199 1" DIA. x 21-1/4" ROD - E-275C
6509-165-199 1" DIA. x 23-1/2" ROD - E-455D
6509-510-199 IMPELLER SHAFT - 16-1/8" - E-156A
6509-515-199 IMPELLER SHAFT - 19-1/8" - E-226B
6509-520-199 IMPELLER SHAFT - 22-1/8" - E-276C
6509-525-199 IMPELLER SHAFT - 26-3/8" - E-456D
6509-110-199 IMPELLER TUBE - 15-1/4" - E-157A
6509-115-199 IMPELLER TUBE - 18-1/4" - E-227B
6509-120-199 IMPELLER TUBE - 21-1/4" - E-277C
6509-125-199 IMPELLER TUBE - 25-1/2" - E-457D
SB-100-S
Stationary “E” Series Parts Diagram
10

ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
2
3C
5
6
7
4
1C1B1A
3B3A
*NOTE: SEE ADDITIONAL DRAWING FOR
DETAIL OF ITEMS NOT SHOWN.
STATIONARY MOTOR/TURBINE - PAGE 9
*
H-60-S
H-75-S
H-90-S
WHITEHALL MODEL
NUMBERS
THESE REPAIR PARTS ARE USED
FOR THE FOLLOWING MODEL
NUMBERS ONLY:
H-105-S
DAKON
MODEL NUMBERS
DF-4828
DF-3628
H-60-M-SDP
H-75-M-SDP
H-90-M-SDP
H-105-M-SDP DD-4828
DD-3628
1A 6525-168-001 TURBINE ASSY - H-60/75/90/105 - 115VAC, 60Hz
1B 6525-169-001 TURBINE ASSY - H-60/75/90/105 - 230VAC, 60Hz
1C 6525-170-001 TURBINE ASSY - H-60/75/90/105 - 230VAC, 50Hz
2 6525-538-001 PLUNGER ASSY - 23-1/4" - H-60/75/90/105-S
3A 6525-200-001 MOTOR ASSY - 115VAC, 60Hz
3B 6525-210-001 MOTOR ASSY - 230VAC, 60Hz
3C 6525-220-001 MOTOR ASSY - 230VAC, 50Hz
4 6525-500-299 1" MOTOR BASE CASTING -S
5 6509-170-199 1" DIA. x 25-1/2" TUBING R & L DEVICES
6 6509-530-199 IMPELLER SHAFT - 29-3/8"
7 6509-130-199 IMPELLER TUBE - 28-1/2"
11
Stationary “H” Series Parts Diagram

ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
2
3C
5
6
7
4
1C1B1A
3B3A
*NOTE: SEE ADDITIONAL DRAWING FOR
DETAIL OF ITEMS NOT SHOWN.
STATIONARY MOTOR/TURBINE - PAGE 9
*
L-75-S
L-90-S
L-105-S
WHITEHALL MODEL
NUMBERS
THESE REPAIR PARTS ARE USED
FOR THE FOLLOWING MODEL
NUMBERS ONLY:
DAKON
MODEL NUMBERS
DF-6018
DF-6618
L-75-M-SDP
L-90-M-SDP
L-105-M-SDP
DD-6018
DD-6618
1A 6525-158-001 TURBINE ASSY - L-75/90/105 - 115VAC, 60Hz
1B 6525-159-001 TURBINE ASSY - L-75/90/105 - 230VAC, 60Hz
1C 6525-160-001 TURBINE ASSY - L-75/90/105 - 230VAC, 50Hz
2 6525-528-001 PLUNGER ASSY - 15-1/4'
3A 6525-200-001 MOTOR ASSY - 115VAC, 60Hz
3B 6525-210-001 MOTOR ASSY - 230VAC, 60Hz
3C 6525-220-001 MOTOR ASSY - 230VAC, 50Hz
4 6525-500-299 MOTOR BASE CASTING R & L -S
5 6525-155-199 1" DIA. x 16-1/2" ROD
6 6509-515-199 IMPELLER SHAFT - 19-1/8"
7 6509-115-199 IMPELLER TUBE - 18-1/4"
Stationary “L” Series Parts Diagram
12

ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
4
2A 2B 2C
6C6B6A
7A 7B 7C
5A 5B 5C
3C3B3A
*1A THRU 1J
NOTE: SEE ADDITIONAL DRAWING FOR
DETAIL OF ITEMS NOT SHOWN.
STATIONARY MOTOR/TURBINE - PAGE 9
*
P-10-S
P-15-M-SDP
P-22-M-SDP
WHITEHALL MODEL
NUMBERS
THESE REPAIR PARTS ARE USED
FOR THE FOLLOWING MODEL
NUMBERS ONLY:
DAKON
MODEL NUMBERS
DF-2516
DF-2818
P-15-S
P-22-S
DD-2516
DD-2818
P-10-M-SDP
1A 6528-102-001 TURBINE ASSY - P-10 - 115VAC, 60Hz
1B 6528-103-001 TURBINE ASSY - P-10 - 230VAC, 60Hz
1C 6528-104-001 TURBINE ASSY - P-10 - 230VAC, 50Hz
1D 6528-105-001 TURBINE ASSY - P-15 - 115VAC, 60Hz
1E 6528-106-001 TURBINE ASSY - P-15 - 230VAC, 60Hz
1F 6528-107-001 TURBINE ASSY - P-15 - 230VAC, 50Hz
1G 6528-108-001 TURBINE ASSY - P-22 - 115VAC, 60Hz
1H 6528-109-001 TURBINE ASSY - P-22 - 230VAC, 60Hz
1J 6528-110-001 TURBINE ASSY - P-22 - 230VAC, 50Hz
2A 6528-522-001 PLUNGER ASSY - 9-1/2" - P-10
2B 6528-525-001 PLUNGER ASSY - 12" - P-15
2C 6528-528-001 PLUNGER ASSY - 15-1/4" - P-22
3A 6528-201-001 MOTOR ASSY - 115VAC, 60Hz - P-11/15/22
3B 6528-210-001 MOTOR ASSY - 230VAC, 60Hz - P-11/15/22
3C 6528-220-001 MOTOR ASSY - 230VAC, 50Hz - P-11/15/22
4 6528-500-199 3/4" MOTOR BASE CASTING -S
5A 6509-555-199 3/4" DIA. x 11-1/2" ROD - P-10
5B 6509-560-199 3/4" DIA. x 13" ROD - P-15
5C 6509-565-199 3/4" DIA. x 16" ROD - P-22
6A 6509-505-199 IMPELLER SHAFT - 13-7/8" - P-10
6B 6509-510-199 IMPELLER SHAFT - 16-1/8" - P-15
6C 6509-515-199 IMPELLER SHAFT - 19-1/8" - P-22
7A 6509-105-199 IMPELLER TUBE - 13" - P-10
7B 6509-110-199 IMPELLER TUBE - 15-1/4" - P-15
7C 6509-115-199 IMPELLER TUBE - 18-1/4" - P-22
Stationary “P” Series Parts Diagram
13

2
3C
5
6
7
4
1C1B1A
3B3A
ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
NOTE: SEE ADDITIONAL DRAWING FOR
DETAIL OF ITEMS NOT SHOWN.
STATIONARY MOTOR/TURBINE - PAGE 9
*
*
S-85-S
S-90-S
S-110-S
WHITEHALL MODEL
NUMBERS
THESE REPAIR PARTS ARE USED
FOR THE FOLLOWING MODEL
NUMBERS ONLY:
DAKON
MODEL NUMBERS
DFT-4825
DFT-5625
S-85-M-SDP
S-90-M-SDP
S-110-M-SDP
1A 6525-165-001 TURBINE ASSY S-85/90/110 - 115VAC, 60Hz
1B 6525-166-001 TURBINE ASSY S-85/90/110 - 230VAC, 60Hz
1C 6525-167-001 TURBINE ASSY S-85/90/110 - 230VAC, 50Hz
2 6525-535-001 PLUNGER ASSEMBLY 20"
3A 6525-200-001 MOTOR ASSEMBLY - 115VAC, 60Hz
3B 6525-210-001 MOTOR ASSEMBLY - 230VAC, 60Hz
3C 6525-220-001 MOTOR ASSEMBLY - 230VAC, 50Hz
4 6525-500-299 1" DIA. MOTOR BASE CASTING
5 6509-165-199 1" DIA. x 23-1/2" ROD
6 6509-525-199 IMPELLER SHAFT - 26-3/8"
7 6509-125-199 IMPELLER TUBE - 25-1/2"
Stationary “S” Series Parts Diagram
14

7
8
9 4
5
6
10
11
12 3B
2B
14
6
8
13
R & L ASSY P/E-22-S
R & L ASSY P/E-15-S
R & L ASSY P-10-S
1D
1B
1A
3A
2A
2C
3C
ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
E-15-S
E-22-S
E-22-SP
WHITEHALL
MODEL
NUMBERS
THESE REPAIR PARTS ARE USED
FOR THE FOLLOWING MODEL
NUMBERS ONLY:
P-10-S
DAKON
MODEL
NUMBERS
DF-2516
P-22-S
P-15-S DF-2516
DF-2818
E-22-MU
DF-2818
R & L ASSY P/E-22-MU/SP
1C
2D
3D
1A 6530-015-001 3/4" DIM. R & L ASSEMBLY - P-10-S
1B 6530-025-001 3/4" DIM. R & L ASSEMBLY - P/E-15-S
1C 6530-030-001 3/4" DIM. R & L ASSEMBLY - P/E-22-MU/SP
1D 6530-045-001 3/4" DIM. R & L ASSEMBLY - P/E-22-S
2A 6509-205-199 1-1/8" DIA. x 12-1/8" TUBE - P-10-S
2B 6509-215-199 1-1/8" DIA. x 18" TUBE - P/E-15-S
2C 6509-215-199 1-1/8" DIA. x 18" TUBE - P/E-22-MU/SP
2D 6509-225-199 1-1/8" DIA. x 20" TUBE - P/E-22-S
3A 6503-005-000 7/8" DIA. x 13" SPRING - P-10-S
3B 6503-015-000 7/8" DIA. x 9" SPRING - P/E-15-S
3C 6503-015-000 7/8" DIA. x 9" SPRING - P/E-22-MU/SP
3D 6503-030-000 7/8" DIA. x 23" SPRING - P/E-22-S
4 6530-110-199 END CAP
5 6502-411-000 1/4"-20 x 5/16" ALLEN HEAD SET SCREW
6 6502-200-000 1/4"-20 x 5/8" PHILLIPS TRUSS HEAD MACH SCRW
7 6530-100-199 UPPER BRACKET
8 0337-050-000 1/4" STAINLESS STEEL LOCKWASHER
9 6502-520-000 1/4"-20 HIGH CROWN ACORN NUT
10 6530-111-199 HANDLE
11 6530-112-199 BUSHING
12 6530-114-199 STUD
13 0302-005-000 1/4"-20 HEX NUT
14 6530-101-199 LOWER BRACKET
Motor Raising & Lowering Assembly (Small)
15

7
8 4
5
6
9
10
11
13
6
12 2E
3E
2F
3F
3D
2D
3A
3C
3B
2A
2C
2B
ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
1C
1B
1A R & L ASSY E-27-S
R & L ASSY E-45-/S-85/90/110-S
R & L ASSY H-60/75/90/105-S 1E
1F1D R & L ASSY L-75/90/105-S
E-27-S
E-36-S
WHITEHALL
MODEL NUMBERS
THESE REPAIR PARTS ARE USED
FOR THE FOLLOWING MODEL
NUMBERS ONLY:
H-60-S
DAKON
MODEL NUMBERS
DF-3628
DF-2821
H-90-S
H-75-S
H-105-S
L-75-M
L-75-S
L-90-M
DF-4828
DST-5625
L-105-M
L-90-S DF-6018
L-105-S
S-85-S
S-85-SL
S-90-S
DF-6618
DFT-4825
S-110-S
S-90-SL
DFT-5625
S-110-SL
DF-2825
L-75-M-SDP
L-75-SL
L-90-M-DS
L-90-M-SDP
L-90-SL
L-105-M-DS
L-105-M-SDP
L-105-SL
S-90-M
S-110-M-SDP DDT-5625
S-110-M
S-90-M-SDP
DDT-4825S-85-M-SDP
S-85-M
E-45-S DF-3225
1A 6530-220-001 1" DIA. R & L ASSY - E-27-S
1B 6530-235-001 1" DIA. R & L ASSY - E-45/S-85/90/110-S
1C 6530-245-001 1" DIA. R & L ASSY - H-60/75/90/105-S
1D 6530-215-001 1" DIA. R & L ASSY - L-75/90/105-S
1E 6530-210-001 1" DIA. R & L ASSY - L-75/90/105-M/SL
1F 6530-225-001 1" DIA. R & L ASSY - E-45-SL/S-85/90/110-M/SL
2A 6509-265-199 1-3/8" DIA. x 23-1/2" TUBE - E-27-S
2B 6509-275-199 1-3/8" DIA. x 27-1/4" TUBE - E-45/S-85/90/110-S
2C 6509-280-199 1-3/8" DIA. x 30-1/2" TUBE - H-60/75/90/105-S
2D 6509-260-199 1-3/8" DIA. x 21-1/4" TUBE - L-75/90/105-S
2E 6509-255-199 1-3/8" DIA. x 18-1/2" TUBE - L-75/90/105-M/S
2F 6509-270-199 1-3/8" DIA. x 18-1/2" TUBE - S-85/90/110-M/SL
3A 6503-265-000 1-1/8" x 23-1/2" SPRING - E-27-S
3B 6503-070-000 1-1/8" x 30-1/2" SPRING - E-45/S-85/90/110-S
3C 6503-075-000 1-1/8" x 34" SPRING - H-60/75/90/105-S
3D 6503-060-000 1-3/8" x 23-1/2" SPRING - L-75/90/105-S
3E 6503-055-000 1-18" x 19" SPRING - L-75/90/105-M/S
3F 6503-065-000 1-18" x 27" SPRING - S-58/90/110-M/SL
4 6530-310-199 END CAP
5 6502-411-000 SET SCREW
6 6502-200-000 1/4"-20 x 5/8" TRUSS HEAD PHILLIPS MS
7 6530-300-199 UPPER BRACKET
8 6502-520-000 1/4"-20 HIGH CROWN ACORN NUT
9 6530-111-199 HANDLE
10 6530-112-199 BUSHING
11 6530-114-199 STUD
12 0302-005-000 1/4"-20 HEX NUT
13 6530-301-199 LOWER BRACKET
Motor Raising & Lowering Assembly
16

ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
SCALED x 1-1/2
1
6
5
4
3
8
7
2
11
910
7
12
1 6530-260-001 R & L ASSEMBLY
2 6502-401-000 1/4"-20 x 5/16 SET SCREW
3 6530-411-199 LOCKING HUB
4 6530-114-199 3/8"-16 UNC STUD
5 6530-112-199 BUSHING
6 6530-111-199 LOCKING HANDLE
7 0116-104-000 1/4"-20 x 1/2" PHILLIPS ROUND HEAD SCREW
8 6530-310-199 END CAP
9 6530-520-000 1/4"-20 STAINLESS STEEL ACORN NUT
10 6530-301-199 LOWER BRACKET
11 6509-265-199 1-3/8" DIA. x 23-1/2" R & L TUBE
12 6503-065-000 1-1/8" DIA. x 27" SPRING
Motor Raising & Lowering Assembly (Slant Back)
17

3
6
7
8
5
1A 1B 1C 1D 1E 1F
9
10 16
13
15
23
2526
24
17
1820 19
14
22
21
30
27
31
12
14
11
2B2A 4 5
ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION
28 29
2A
1A 6531-010-001 DRAIN & OVERFLOW - H-60-S
1B 6531-012-001 DRAIN & OVERFLOW - H-75-S
1C 6531-011-001 DRAIN & OVERFLOW - H-90/105-S
1D 6531-015-001 DRAIN & OVERFLOW - S-85-S
1E 6531-014-001 DRAIN & OVERFLOW - S-90-S
1F 6531-016-001 DRAIN & OVERFLOW - S-110-S
2A 6509-346-199 2" O.D. x 17-3/4" DRAIN TUBE - H-60-S
2B 6509-360-199 2" O.D. x 20-3/8" DRAIN TUBE - H-75-S
3 6509-370-199 2" O.D. x 23-5/8" DRN TUBE - H-90/105-S/-85-S
4 6509-365-199 2" O.D. x 22-3/8" DRAIN TUBE - S-90-S
5 6509-385-199 2" O.D. x 27-1/2" DRAIN TUBE - S-110-S/HI-BOY
6 6508-000-199 DRAIN ELBOW
7 6504-500-000 DRAIN GASKET
8 6508-050-199 STRAINER
9 6508-010-199 DRAIN TEE
10 6509-375-199 2" O.D. x 24" DRAIN TUBE - SPORTS
11 6531-056-001 33-1/4" OVERFLOW ASSEMBLY - HI-BOY
12 6531-055-001 29-5/8" OVERFLOW ASSEMBLY
13 6531-102-199 HANDLE
14 6502-450-000 #8-32 x 3/8" PHILLIPS PAN HEAD SCREW
15 6531-110-001 FRICTION LOCK ASSEMBLY
16 6531-100-001 OVERFLOW BRACE
17 0337-050-000 1/4" STN STL HELICAL LOCKWASHER
18 6502-103-000 #8-32 x 1/4" PHILLIPS PAN HEAD SCREW
19 6502-200-000 1/4"-20 x 5/8" PHILLIPS TRUSS HEAD SCREW
20 6502-520-000 1/4"-20 ACORN NUT
21 6509-405-199 2" O.D. x 5" DRAIN TUBE
22 6531-104-000 ESCUTCHEON
23 6531-110-199 FRICTION LOCK HOUSING
24 6531-111-199 FRICTION LOCK ROD
25 6531-113-000 SPRING
26 6531-112-199 TENSION ADAPTER
27 6531-101-199 COLLAR (UP-STOP)
28 6509-085-199 33-1/4" OVERFLOW TUBE
29 6509-080-199 29-5/8' OVERFLOW TUBE
30 6504-221-000 O-RING
31 6531-103-199 O-RING COUPLING
Drain / Overflow Assembly - H/S Series
18
This manual suits for next models
1
Table of contents
Other Whitehall Hot Tub manuals
Popular Hot Tub manuals by other brands

CalderaSpas
CalderaSpas CalderaSpas Utopia Series owner's manual

anko
anko SS-601A user manual

CalderaSpas
CalderaSpas CANTABRIA owner's manual

Dimension One Spas
Dimension One Spas HYDRO SPORT Installation and owner's guide

Bestway
Bestway Lay-Z-Spa Maldives HydroJet Pro manual

Dimension One Spas
Dimension One Spas Nautilus Specifications