Worldwide WD4XETH2 User manual

User Manual
WD4XETH2
WD4X Single Port Ethernet Communication Card
Copyright 2023 WorldWide Electric Corporation | The Globe icon is a registered trademark of WorldWide Electric Corporation | Printed April 2023
(800) 808-2131
worldwideelectric.com
Motor
Controls

WD4X Ethernet Module Manual
i
Thank you for using our WD4X Ethernet option module
Safety PRECAUTIONS
Always follow safety instructions to prevent accidents and potential hazards
from occurring.
Safety precautions are classified into “WARNING” and “CAUTION” and their
meanings are as follows:
WARNING Improper operation may result in serious personal
injury or death.
CAUTION Improper operation may result in slight to medium
personal injury or property damage
The indicated illustrations on the product and in the manual have the following
meanings.
Danger may be present. Read the message and follow the instructions
carefully.
Particular attention should be paid because danger of an electric shock may
be present.
Keep operating instructions handy for quick reference.
Read the operating instructions carefully to fully understand the functions of
the WD4X series and to use itproperly.
CAUTION
Be cautious, when handling the CMOS components of the communication
module.
Static may lead to malfunctioning of the product.
Turn off the inverter power, when changing the communication cable.
Otherwise, you may damage the module or a communication error may occur.
Make sure to insert the Communication module connector to the inverter
precisely.
Otherwise, you may damage the module or a communication error may occur.
Check the parameter unit before setting up the parameter.
Otherwise, a communication error may occur.

WD4X Ethernet Module Manual
ii
1. Introduction................................................................................................1
1.1
What is Ethernet? ............................................................................... 1
1.2
Components...................................................................................... 1
2. Ethernet Communication Module Features...............................................2
2.1
Common Features.............................................................................. 2
2.2
Layout of Ethernet Communication Module............................................ 2
2.3
Installation ........................................................................................ 3
2.4
Terminal Block of Ethernet communication Specifications ....................... 5
2.5
Network Cable Specification ................................................................ 6
2.6
Protocol Selection.............................................................................. 7
3. LED information.........................................................................................8
3.1
LED display feature ............................................................................ 8
3.2
The status of Ethernet Line LED
(Ethernet/IP and Modbus/TCP are same)
................ 8
3.3
The status of Modbus/TCP LED & Troubleshooting................................. 9
3.4
The status of Ethernet/IP LED & Troubleshooting ................................. 10
4. Keypad Parameter of Ethernet Communication......................................11
4.1
FBus S/W Ver (CM-06) ..................................................................... 13
4.2
FBus Led (CM-09) ........................................................................... 13
4.3
IP Address, Subnet Mask, Gateway (CM-10~21) Setting....................... 15
4.4
Ethernet Speed (CM-22)................................................................... 15
4.5
CIP Input Instance(CM-29)................................................................ 16
4.6
CIP Output Instance(CM-49) ............................................................. 17
4.7
Para Status (CM-30~38) .................................................................. 18
4.8
Para Control (CM-50~58) ................................................................. 18
4.9
Comm Update (CM-94) .................................................................... 18
5. Modbus/TCP............................................................................................19
5.1
Modbus/TCP Frame Structure ............................................................ 19
5.2
Function Code Description ................................................................ 19
5.3
Read Holding Register ...................................................................... 20
5.4
Read Input Register.......................................................................... 21
5.5
Write Single Register ........................................................................ 22
5.6
Write Multiple Register ...................................................................... 23
5.7
Except Frame .................................................................................. 24
5.8
Exception Frame Structure ................................................................ 24
5.9
Exception Code Type ....................................................................... 24
6. Ethernet/IP...............................................................................................25
6.1
Basic protocol configuration.............................................................. 25
6.2
Implicit Message .............................................................................. 26
6.3
Explicit Message .............................................................................. 34
6.4
Supported Object............................................................................. 35
7. Lost Command........................................................................................46
7.1
Inverter Keypad Parameter ................................................................ 46

WD4X Ethernet Module Manual
1
1. Introduction
1.1
What is Ethernet?
Ethernet communication module board connects the WD4X
inverter to the Ethernet network. It supports two kinds of
protocol, Modbus/TCP and Ethernet/IP.
Controlling and monitoring of inverter can be done by PLC
sequence program or any Master Module. Since Ethernet which
constitutes Internet has been used and IPv4 has been supported,
wherever Internet can be done, controlling and monitoring are
possible. But, Ethernet network of the factory has to be
connected to Internet through gateway.
Installation time can be reduced and maintenance becomes
easier just simple wiring.
1.2
Components
This product is consisting of these kinds of parts.
- Ethernet Communication Module board (WD4XETH2): 1 ea
- Ethernet Module manual: 1 ea
- Brass Bar(M3xL23): 1 ea
- Brass Bar(M3xL17.3): 1 ea
- Fixed Screw(M3xL8): 2 ea

WD4X Ethernet Module Manual
2
2. Ethernet Communication Module Features
2.1
Common Features
Transmission Speed
10Mbps, 100Mbps
Transmission Method
Baseband
Max. Extensible Distance
between Nodes
100m (Node-Hub)
Max. Node Number
Hub connection
Auto-Negotiation
Supported
Max. Frame Size
1,500 bytes
Communication Zone Access
Method
CSMA/CD
Frame Error Checking Method
CRC32
Recommended TCP Socket
2 Sockets
2.2
Layout of Ethernet Communication Module
Ethernet Connector
Protocol Select S/W

WD4X Ethernet Module Manual
3
2.3
Installation
Warning) Connect a communication network after the power supply
is off. If Ethernet communication module is removed or installed, the
power supply should be switched off. Otherwise, the WD4X inverter
will be damaged entirely. Take off Ethernet communication module
from the product after the power supply is totally discharged.
Step 1:
Loosen all cover screws and remove cover.
Step 2:
Remove the keypad connector.
Step 3:
Remove the keypad adapter PCB.
It may be helpful to use a screwdriver
to clear the plastic tabs.

WD4X Ethernet Module Manual
4
Step 4:
Once the keypad PCB adapter is removed,
install the two standoffs which are included
in the Ethernet card kit.
Step 5:
Install the Ethernet card.
Step 6:
Install the two screws to secure the Ethernet
card to the standoffs. Snap the keypad adapter
PCB into place on top of the Ethernet card.
Step 7:
Reconnect keypad connector cable.
Connect network cable. Reinstall front cover.

WD4X Ethernet Module Manual
5
2.4
Terminal Block of Ethernet communication Specifications
※Make sure that cables connected to Pin1 and 2 are twisted together.
※Make sure that cables connected to Pin3 and 6 are twisted together
Pin No.
Signal
Description
Cable color
1 TX+ Transmitting data Plus White / Yellow
2 TX- Transmitting data Minus Yellow
3 RX+ Receiving data Plus White / Green
4 NONE Not used Blue
5 NONE Not used White / Blue
6 RX- Receiving data Minus Green
7 NONE Not used White / Brown
8 NONE Not used Brown
8
1

WD4X Ethernet Module Manual
6
2.5
Network Cable Specification
Category 5 is used. Transmission speed of category 5 is
100MHz and available up to 100Mbps.
Classification Detail Used
UTP (U.UTP)
Unshielded
twisted pair
cable
Maximum 200MHz,
Voice + Information (Data)+Low video signal
FTP (S.UTP) Foil screened
twisted pair
cable
Maximum 100MHz
Electromagnetic interruption (EMI) or
electric stability considered,
Voice+ Information (Data) +
Low Video signal
STP (S.STP)
Shielded
twisted pair
cable
Maximum 500MHz,
Voice +Information(Data)+Video signal,
Replacement for 75Ω coaxial cable

WD4X Ethernet Module Manual
7
2.6
Protocol Selection
For using the WD4X Ethernet option module, there are 2 kinds
of protocols, Modbus TCP and Ethernet IP. You can select one
of the protocols by selecting the No.1 switch. The switch is
placed next to the Ethernet connector for Ethernet cable. No. 2,
3 and 4 of switch are not available.
Switch State Protocol
OFF (Switch at the upper position) Modbus TCP
ON (Switch at the lower position Ethernet IP
If the option module is operating, protocol will not be changed
even if switch selection is changed. Protocol is determined by the
state of switch when the option module is turned on or the
inverter is initialized by ‘Yes’ execution of COM-94 Comm Update.
<The bottom side of Ethernet Communication Module >
1 2 3 4
Protocol select S/W (No.1 switch)
Ethernet connector

WD4X Ethernet Module Manual
8
3. LED information
3.1
LED display feature
Four LEDs are located on WD4X Ethernet Communication
Module. Each LED indicates different functions and displays the
status of Ethernet Protocol for a client.
3.2
The status of Ethernet Line LED
(Ethernet/IP and Modbus/TCP are same)
LED
Color
Status
Function
SPEED Green
ON
It indicates the communication speed is 100Mbps.
OFF
It indicates the communication speed is 10Mbps.
LINK Green
ON
It indicates the communication module is ready to
communicate.
OFF
In case that wiring communication cable has a
fault, Link LED is turned Off. Check if wiring is
correct.
NS/CPU
MS/ERR
SPEED
LINK

WD4X Ethernet Module Manual
9
3.3
The status of Modbus/TCP LED & Troubleshooting
LED
Color
Status
Function and Troubleshooting
CPU Green
Flash
It means the CPU of Modbus/TCP is
operating normally when the power is well
supplied to the communication module.
OFF
Failure in power supply to the
communication module. Re-install the
module.
ERRORRed
OFF
It means the communication module is
normal without error.
ON
It means IP address sets to 0.0.0.0 or
255.255.255.255. Please do not use the
address IPAddress because it can be only
used for the specific case.
CPU
and
Flash
1. It means the communication is
interrupted. Turn off the power and then
reinstall the module.
2. The data from inverter is not updated to
Ethernet Module. Execute Comm. Update or
re-generate the power again.
Flashing
slower
than
CPU
IP address is conflicted in a network. Check
if IP address is appropriate.

WD4X Ethernet Module Manual
10
3.4
The status of Ethernet/IP LED & Troubleshooting
LED
Color
Status
Function and Troubleshooting
NS
Green
ON
It means the status is I/O communicating
when Class 1 connection is well connected.
OFF
It means Client and TCP are not connected.
Flash
It means UCMM communication is available by
the registration after Client and TCP are
connected.
Red
ON
Displayed if an IP address is clashed with the
same IP address in a network. Please check
whether IP address is right or not.
OFF
It means Communication module is normal
Flash
It means Class 1 connection is disconnected
abnormally. Check if the Network cable and
connection state are correct.
MS
Green ON
It means communication module board is
normal.
OFF
It means communication module has a problem.
Red
ON
It means IP address sets to 0.0.0.0 or
255.255.255.255. Please do not use the address
IPAddress because it can be only used for the
specific case.
OFF
It means Communication module is normal.
Flash
1. It means the communication is interrupted.
Turn off the power and then reinstall the module
.
2. The data from inverter is not updated to
Ethernet Module. Do Comm. Update or re-
generate the power again.
Notice
1) When the module is initialized by the selection of Ethernet/IP, LED
turns on and off in order as below.
(MS LED(GREEN) -> NS LED(RED) -> MS LED(RED) -> NS LED(GREEN)
-> NS LED(RED)-> NS LED(OFF)->MS LED(GREEN))
2) When IP address is crashed, please reset IP and execute Comm. Update.
3) Do not use Comm Update (CM-94 1) when the inverter is working
or in cyclic communication.

WD4X Ethernet Module Manual
11
4. Keypad Parameter of Ethernet Communication
Inverter parameters of Modbus/TCP and Ethernet/IP are listed as
shown below. (Protocol ‘M’ is used for Modbus/TCP and Protocol
‘E’ is used for Ethernet/IP)
Code
Number
The Name of
Parameter
Initial
Value
Range Definition
Protocol
CM-06 FBus S/W Ver - - It indicates the version of
Ethernet communication
module. M/E
CM-09 FBus Led Shows the ON/OFF data of
the LED on the Ethernet
communication module.
M/E
CM-10 Opt Parameter1 0 0 ~ 255
Set up the IPAddress. M/E
CM-11
Opt Parameter2
0
0 ~ 255
CM-12 Opt Parameter3 0 0 ~ 255
CM-13
Opt Parameter4
0
0 ~ 255
CM-14 Opt Parameter5 0 0 ~ 255
Set up the Subnet Mask. M/E
CM-15
Opt Parameter6
0
0 ~ 255
CM-16 Opt Parameter7 0 0 ~ 255
CM-17
Opt Parameter8
0
0 ~ 255
CM-18 Opt Parameter9 0 0 ~ 255 Set up the Gateway
Address. M/E
CM-19
Opt Parameter10
0
0 ~ 255
CM-20 Opt Parameter11 0 0 ~ 255
CM-21
Opt Parameter12
0
0 ~ 255
CM-22 Opt Parameter13 0 0~2
Set up the Ethernet
communication rate.
M/E
CM-29
In Instance
1
0~11
CIP Input Instance
E
CM-30 ParaStatus Num 3 0~8 Automatically set up
according to the CIP Input
Instance. E
CM-31 Para Status-1 0x000A
0x0000
~0xFFFF
Set up the inverter data
address which will be read
by the client.
E
CM-32 Para Status-2 0x000D
0x0000
~0xFFFF
E

WD4X Ethernet Module Manual
12
Code
Number
The Name of
Parameter
Initial
Value
Range Definition
Protocol
CM-33 Para Status-3 0x000F
0x0000
~0xFFFF
E
CM-34 Para Status-4 0x0000
0x0000
~0xFFFF
E
CM-35 Para Status-5 0x0000
0x0000
~0xFFFF
E
CM-36 Para Status-6 0x0000
0x0000
~0xFFFF
E
CM-37 Para Status-7 0x0000
0x0000
~0xFFFF
E
CM-38 Para Status-8 0x0000
0x0000
~0xFFFF
E
CM-49
Out Instance
1
0~11
CIP Output Instance
E
CM-50 Para Ctrl Num 2 0~8
Automatically set up
according to the CIP
Output Instance.
E
CM-51 Para Control-1 0x0005
0x0000
~0xFFFF
Client set up the reference
Inverter Data Address.
E
CM-52 Para Control-2 0x0006
0x0000
~0xFFFF
E
CM-53 Para Control-3 0x0000
0x0000
~0xFFFF
E
CM-54 Para Control-4 0x0000
0x0000
~0xFFFF
E
CM-55 Para Control-5 0x0000
0x0000
~0xFFFF
E
CM-56 Para Control-6 0x0000
0x0000
~0xFFFF
E
CM-57 Para Control-7 0x0000
0x0000
~0xFFFF
E
CM-58 Para Control-8 0x0000
0x0000
~0xFFFF
E
CM-94 Comm Update 0 0:NO
1:YES
Update communication
relating to keypad
parameters.
M/E

WD4X Ethernet Module Manual
13
4.1
FBus S/W Ver (CM-06)
CM-06 automatically indicates the version of the communication
module presently installed in the WD4X.
4.2
FBus Led (CM-09)
①Modbus/TCP
ON/OFF state of 4LEDs in WD4X Ethernet
communication module is displayed at keypad parameter CM-05.
If you check CM-09 FBus LED with Keypad, 4 bits can be seen
according to the order of LED of CM-05 (Left ->Right) CPU,
ERR, SPEED and LINK LED.
When LED is ON, the bit becomes 1 and when OFF, it becomes
0.
(Ex. CM-09 LED)
LINK LED
SPEED LED
ERR LED
CPU LED
OFF
ON
OFF
ON
(ON)
(OFF)
LINK SPEED
ERR CPU

WD4X Ethernet Module Manual
14
②Ethernet/IP
It represents the ON/OFF status of the 2 LEDs on the right side
among the 4 LEDs on the keypad parameter CM-09. 4bits can be
displayed in CM-09 FBus Led by using keypad. The data lists of
CM-09 are shown as below. When LED turns on, each bit
becomes 1, and vice versa. Ethernet communication module has
MS LED and NS LED only, but 4 LEDs are shown from CM-09
(FBus LED) using keypad.
It displays the information of NS LED Red, NS LED Green, MS
LED Red and MS LED Green in the order of CM-09 LEDs
(Right Left).
If CM-09 is displayed as below, it indicates that NS LED is
currently Green and MS LED is Green.
(Ex. CM-09 LED)
MS
LED(Red)
MS
LED(Green)
NS
LED(Red)
NS
LED(Green)
OFF
ON
OFF
ON
MS LED NS LED
Red Green Red Green
(ON)
(OFF)

WD4X Ethernet Module Manual
15
4.3
IP Address, Subnet Mask, Gateway (CM-10~21) Setting
The IP ver. supported by Ethernet Module is v4.
All the addresses and maskes are expressed with
(decimal).(decimal).(decimal).(decimal) and each decimal
number is within 0~255.
In Ethernet communication Module, decimal numbers can be
entered in Opt Parameter directly. Each Opt Parameters has the
value 0 through 255, which is implemented with each field of
addresses divided with ‘.’.
Ex) To set up IP Address 196.168.10.131, enter the Opt
Parameter as shown in the table below.
Code Number
The name of
Parameter
CM-10 Opt Para-1 196
CM-11 Opt Para-2 168
CM-12
Opt Para-3
10
CM-13 Opt Para-4 131
4.4
Ethernet Speed (CM-22)
Ethernet speed can be set up within the range of 0~2
Automatic speed setting function automatically sets up the
highest speed in the network.
Set Value
Speed
0
Set the speed automatically
1
100Mbps
2
10Mbps
Input Value

WD4X Ethernet Module Manual
16
4.5
CIP Input Instance(CM-29)
This parameter is displayed when the protocol setting is the
Ethernet/IP. It sets up the data format of the inverter status sent
from the inverter to the Client (Originator) during the I/O
communication module of the CIP (Common Industrial Protocol).
Refer to the Assembly Object of the Ethernet/IP.
Set Value
Input Instance
Value
Data Size
The number of
Parameter
0
70
4
X
1
71
4
X
2
110
4
X
3
111
4
X
4
141
2
1
5
142
4
2
6
143
6
3
7
144
8
4
8
145
10
5
9
146
12
6
10
147
14
7
11
148
16
8

WD4X Ethernet Module Manual
17
4.6
CIP Output Instance(CM-49)
This parameter is displayed only when protocol sets to
Ethernet/IP. It sets up the data format of the inverter command
sent from the Client (Originator) to control the inverter during the
I/O communication module of the CIP (Common Industrial
Protocol). Refer to the Assembly Object of the Ethernet/IP.
Set Value
Output Instance
Value
Data Size
The number of
Parameter
0
20
4
X
1
21
4
X
2
100
4
X
3
101
4
X
4
121
2
1
5
122
4
2
6
123
6
3
7
124
8
4
8
125
10
5
9
126
12
6
10
127
14
7
11
128
16
8
Table of contents
Popular Network Card manuals by other brands

Renesas
Renesas User System Interface Board HS1650ECN61H user manual

NEC
NEC switch user manual

Net to Net Technologies
Net to Net Technologies UIM-E3 installation instructions

ZyXEL Communications
ZyXEL Communications G-170S quick start guide

AMX
AMX netlinx NXC-IRS4 installation guide

Asus
Asus WL-107 quick start guide