manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wyrestorm
  6. •
  7. Security Camera
  8. •
  9. Wyrestorm CAM-210-PTZ User manual

Wyrestorm CAM-210-PTZ User manual

Popular Security Camera manuals by other brands

ADEMCO RapidDome Owners Operating & Installation Guide

ADEMCO

ADEMCO RapidDome Owners Operating & Installation Guide

EverFocus EBA2880 user manual

EverFocus

EverFocus EBA2880 user manual

Honeywell OptiCAM-IR Installation and setup guide

Honeywell

Honeywell OptiCAM-IR Installation and setup guide

Uniq UC-600 user manual

Uniq

Uniq UC-600 user manual

OPTICOM NVD-120-S datasheet

OPTICOM

OPTICOM NVD-120-S datasheet

Steren CCTV-221 instruction manual

Steren

Steren CCTV-221 instruction manual

Arm Electronics C420BCDNVFIR Features

Arm Electronics

Arm Electronics C420BCDNVFIR Features

Eneo PLD-2036PTZ installation guide

Eneo

Eneo PLD-2036PTZ installation guide

Axis AXIS M20 Series installation guide

Axis

Axis AXIS M20 Series installation guide

Panasonic KX-HCM230 operating instructions

Panasonic

Panasonic KX-HCM230 operating instructions

COP-USA CC15NV-SL Specifications

COP-USA

COP-USA CC15NV-SL Specifications

Active Silicon HARRIER H.264 quick start guide

Active Silicon

Active Silicon HARRIER H.264 quick start guide

Motorola Avigilon 1.3C-H5SL-BO1-IR installation guide

Motorola

Motorola Avigilon 1.3C-H5SL-BO1-IR installation guide

INSTEON 2864-232 user manual

INSTEON

INSTEON 2864-232 user manual

Wisenet XNB-6002 quick start guide

Wisenet

Wisenet XNB-6002 quick start guide

Axis M5525-E user manual

Axis

Axis M5525-E user manual

Vitek VTC-IR62NZ922 user guide

Vitek

Vitek VTC-IR62NZ922 user guide

Panasonic WV-SF342 Specifications

Panasonic

Panasonic WV-SF342 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Quickstart Guide
Copyright © 2023 WyreStorm ProAV Corporation | wyrestorm.com
CAM-210-PTZ Quickstart Guide | 230209
UK: +44 (0) 1793 676 683 | ROW: 844.280.WYRE (9973)
[email protected]
1 of 2
WyreStorm recommends reading through this document in its entirety to become familiar with the product’s features prior to starting the
installation process.
IMPORTANT! Installation Requirements
• Visit the product page to download the latest rmware, document version, additional documentation, and conguration tools.
• Read through the Wiring and Connections section for important wiring guidelines before creating or choosing premade cables.
1080p60 PTZ Camera with USB 3.0,
HDMI Out, Auto Framing
CAM-210-PTZ
In the Box
1x CAM-210-PTZ Camera
1x 12V DC 1A PSU (US/UK/EU/AU)
1x IR Remote
1x Wall Mount
1x 2m 8 pin Mini Din RS-232 Cable
1x 1.5m USB 3.0 Type B Host Cable
1x QuickStart Guide
Basic Wiring Diagram
KEY
USB 3.0
HDMI
Ethernet
Personal Computer
Wireless Router
Display Device
Wiring and Connections
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher. Read through this section in it’s
entirety before running or terminating the wires to ensure proper operation and to avoid damaging equipment.
IMPORTANT! Wiring Guidelines
• The use of patch panels, wall plates, cable extenders, kinks in cables, and
electrical or environmental interference will have an adverse effect on
signal transmission which may limit performance. Steps should be taken
to minimize or remove these factors completely during installation for best
results.
• WyreStorm recommends the use of shielded category cable to minimize
signal noise and interference.
• WyreStorm recommends using pre-terminated cables due to the
complexity of these connector types. Using pre-terminated cables will
ensure that these connections are accurate and will not interfere with the
performance of the product.
WyreStorm CAM-210-PTZ
Software Device Setup
Connecting To Zoom
To connect the WyreStorm CAM-210-PTZ to your Zoom software, rst navigate to your settings pane which can be found by clicking the gear icon in the top
right hand corner, then click on the Video tab. Here you can change the camera device by using the dropdown menus. Select WyreStorm CAM-210-PTZ under
the applicable options.
WyreStorm CAM-210-PTZ
Connecting To Microsoft Teams
To connect the WyreStorm CAM-210-PTZ to your Microsoft Teams software, rst navigate to your settings pane which can be found by clicking on your display
image in the top right hand corner, then click on the devices tab. Here you can change the camera device by using the dropdown menus. Select WyreStorm
CAM-210-PTZ under the applicable options.
Copyright © 2023 WyreStorm ProAV Corporation | wyrestorm.com
CAM-210-PTZ Quickstart Guide | 230209
UK: +44 (0) 1793 676 683 | ROW: 844.280.WYRE (9973)
[email protected]
2 of 2
Troubleshooting
No or Poor Quality Picture (snow or noisy image)
• Verify that WyreStorm CAM-210-PTZ has been selected in your software’s device
settings
• Check Web UI settings for Video resolution and Frame rate to ensure
compatibility with your software
• Verify that the device is not in standby
• Verify that power is being supplied to the device
• Verify that all connections are not loose and are functioning properly
• Verify that the RJ-45 cable is properly terminated following EIA568B standard
Troubleshooting Tips:
• WyreStorm recommends using a cable tester or connecting the cable to other
devices to verify functionality.
Default IP Address 192.168.11.43 Default HTTP Port 80 VISCA Control Port 5678
Setup and Conguration
Accessing the Web UI
This camera is set to a default static IP Address (192.168.11.43). In order to communicate with it initially the PC must be set to a 192.168.11.xxx address with a
subnet of 255.255.0.0. This can be changed back once a static IP is set within a different range.
1. Connect the camera to the same network as a PC.
2. Open a web browser and enter the IP Address of the camera.
Username: admin | Password: admin
Using Control Software
The CAM-210-PTZ can be controlled via the PTZ Camera Control software included in the WyreStorm Management
Suite. Connection can be made via LAN or RS-232 to test or troubleshoot camera functions.